Professional Documents
Culture Documents
General Information
File name: Fiber2_1550.trc
Test date: 6/7/2019 Customer:
Test time: 10:45:58 AM Company:
Cable ID: Fiber ID: Fiber2
Job ID:
Comments:
Locations
Location A Location B
Location
Operator
Model FTB-735C-SM1-EI
Serial number 1227566
Calibration date 3/30/2019 (UTC)
Results
Span length: 79.2523 km Average loss: 0.260 dB/km Injection level: 29.2 dB
Span loss: 20.569 dB Average splice loss: 0.197 dB
Span ORL: 30.46 dB Maximum splice loss: 0.523 dB
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.307 dB/km A-B average loss: 0.292 dB/km
a 15.9995 25.357 A-B LSA loss: 4.909 dB 4-point Event Loss: 0.450 dB
A 31.9990 21.452 A-B ORL: 33.49 dB Maximum reflectance: -62.6 dB
B 48.0011 16.783
b 64.0006 12.757
Macrobend
No macrobend detected.
Test Parameters
A→B
Wavelength (nm) 1550 nm (9 µm)
Range (km) 80.0000
Pulse (ns) 500
Duration (s) 5
Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325 1310 nm - 1550 nm 0.500
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000
Locations
Location A Location B
Location
Operator
Model FTB-735C-SM1-EI
Serial number 1227566
Calibration date 3/30/2019 (UTC)
Results
Span length: 57.1341 km Average loss: 0.417 dB/km Injection level: 31.4 dB
Span loss: 23.848 dB Average splice loss: 0.196 dB
Span ORL: 31.30 dB Maximum splice loss: 0.496 dB
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.473 dB/km A-B average loss: 0.453 dB/km
a 15.9995 25.019 A-B LSA loss: 7.563 dB 4-point Event Loss: 0.229 dB
A 31.9990 19.334 A-B ORL: 32.76 dB Maximum reflectance: -63.4 dB
B 48.0011 12.077
b 64.0006 0.000
Macrobend
No macrobend detected.
Pass/Fail Thresholds
1310 nm (9 µm)
Splice loss (dB) 0.300
Connector loss (dB) 0.750
Splitter loss (dB) 4.500
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.400
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00
Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.467700 1310 nm - 1550 nm 0.500
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000