You are on page 1of 6

OTDR Report (1310 nm (9 µm)) Fail

General Information
File name: Final DWDM Huawei Tol-ATL V3 pto 16 CTC_1310.sor
Test date: 09/01/2024 Customer:
Test time: 09:35:45 p. m. Company:
Cable ID: Fiber ID: Fiber19
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model FTBx-740C-CW18-EA
Serial number 1440024
Calibration date 12/03/2021 (UTC)

Results
Span length: 85.4318 km Average loss: 0.385 dB/km Injection level: 36.3 dB
Span loss: 32.879 dB Average splice loss: 0.140 dB
Span ORL: 32.65 dB Maximum splice loss: 0.372 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.347 dB/km A-B average loss: 0.357 dB/km
a 16.0038 29.679 A-B LSA loss: 5.548 dB 4-point Event Loss: -0.587 dB
A 31.9973 23.530 A-B ORL: 31.97 dB Maximum reflectance: -62.2 dB
B 48.0011 17.822
b 63.9998 11.825

Signature: _______________________________ Date: 1/9/2024 Page 1 of 6


OTDR Report (1310 nm (9 µm)) Fail
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- --- 0.000
Section 1.0622 0.333 0.313 0.333
Reflective 2 1.0622 0.821 -43.6 1.154
Section 4.4324 1.448 0.327 2.602
Non-Reflective 3 5.4946 0.115 2.717
Section 4.0086 1.395 0.348 4.112
Non-Reflective 4 9.5032 0.236 4.349
Section 0.9702 0.328 0.338 4.677
Positive 5 10.4734 -0.095 4.582
Section 3.9882 1.342 0.337 5.924
Non-Reflective 6 14.4616 0.180 6.104
Section 4.8512 1.670 0.344 7.774
Non-Reflective 7 19.3128 0.100 7.874
Section 3.2835 1.166 0.355 9.041
Non-Reflective 8 22.5963 0.112 9.153
Section 0.7302 0.268 0.368 9.421
Non-Reflective 9 23.3265 0.191 9.613
Section 10.8922 4.034 0.370 13.647
Non-Reflective 10 34.2187 0.065 13.712
Section 12.1228 4.067 0.335 17.779
Non-Reflective 11 46.3415 0.170 17.949
Section 5.1576 1.733 0.336 19.682
Non-Reflective 12 51.4991 0.168 19.849
Section 2.1754 0.565 0.260 20.414
Non-Reflective 13 53.6744 0.248 20.662
Section 3.4265 1.218 0.355 21.880
Non-Reflective 14 57.1009 0.073 21.953
Section 2.3694 0.770 0.325 22.724
Non-Reflective 15 59.4703 0.079 22.802
Section 5.3618 1.952 0.364 24.754
Non-Reflective 16 64.8321 0.079 24.834
Section 6.2401 2.177 0.349 27.011
Non-Reflective 17 71.0723 0.372 27.382
Section 14.3595 5.496 0.383 32.879
End of Analysis 18 85.4318 --- 32.879

Macrobend
No macrobend detected.

Signature: _______________________________ Date: 1/9/2024 Page 2 of 6


OTDR Report (1310 nm (9 µm)) Fail
Pass/Fail Thresholds
1310 nm (9 µm)
Splice loss (dB) 0.150
Connector loss (dB) 0.500
Splitter loss (dB) 4.500
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.400
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00

Test Parameters
A→B
Wavelength (nm) 1310 nm (9 µm)
Range (km) 120.0000
Pulse (μs) 2.5
Duration (s) 90

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.467700 1310 nm - 1550 nm 0.500
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 15.000

Signature: _______________________________ Date: 1/9/2024 Page 3 of 6


OTDR Report (1550 nm (9 µm)) Fail
General Information
File name: Final DWDM Huawei Tol-ATL V3 pto 16 CTC_1550.sor
Test date: 09/01/2024 Customer:
Test time: 09:37:17 p. m. Company:
Cable ID: Fiber ID: Fiber19
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model FTBx-740C-CW18-EA
Serial number 1440024
Calibration date 12/03/2021 (UTC)

Results
Span length: 95.6296 km Average loss: 0.242 dB/km Injection level: 36.0 dB
Span loss: 23.131 dB Average splice loss: 0.140 dB
Span ORL: 32.72 dB Maximum splice loss: 0.391 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.209 dB/km A-B average loss: 0.223 dB/km
a 16.0038 31.493 A-B LSA loss: 3.339 dB 4-point Event Loss: -0.646 dB
A 31.9973 27.165 A-B ORL: 33.02 dB Maximum reflectance: -59.6 dB
B 48.0011 23.597
b 63.9998 20.025

Signature: _______________________________ Date: 1/9/2024 Page 4 of 6


OTDR Report (1550 nm (9 µm)) Fail
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- -52.0 0.000
Section 1.0566 0.185 0.176 0.185
Reflective 2 1.0566 0.867 -39.8 1.053
Section 4.4867 0.911 0.203 1.964
Non-Reflective 3 5.5433 0.081 2.045
Section 3.9610 0.773 0.195 2.818
Non-Reflective 4 9.5043 0.229 3.047
Section 4.9563 0.982 0.198 4.029
Non-Reflective 5 14.4606 0.159 4.188
Section 4.0273 0.827 0.205 5.015
Non-Reflective 6 18.4879 0.176 5.190
Section 0.8830 0.184 0.209 5.375
Non-Reflective 7 19.3709 0.113 5.488
Section 1.4445 0.255 0.177 5.743
Non-Reflective 8 20.8154 0.081 5.824
Section 1.6997 0.317 0.186 6.141
Non-Reflective 9 22.5152 0.120 6.261
Section 0.7708 0.198 0.257 6.459
Non-Reflective 10 23.2859 0.319 6.778
Section 7.0950 1.621 0.228 8.398
Non-Reflective 11 30.3810 0.077 8.476
Section 3.0626 0.681 0.222 9.157
Non-Reflective 12 33.4436 0.128 9.285
Section 0.6993 0.133 0.191 9.418
Non-Reflective 13 34.1428 0.086 9.504
Section 12.1891 2.347 0.193 11.851
Non-Reflective 14 46.3320 0.187 12.038
Section 5.1554 1.038 0.201 13.076
Non-Reflective 15 51.4873 0.169 13.244
Section 1.3680 0.289 0.211 13.534
Positive 16 52.8553 -0.138 13.395
Section 0.8575 0.176 0.206 13.572
Non-Reflective 17 53.7128 0.174 13.746
Section 5.6556 1.213 0.214 14.959
Non-Reflective 18 59.3684 0.057 15.016
Section 2.7155 0.488 0.180 15.504
Non-Reflective 19 62.0839 0.103 15.607
Section 2.7053 0.500 0.185 16.107
Non-Reflective 20 64.7892 0.137 16.244
Section 3.9456 0.729 0.185 16.973
Non-Reflective 21 68.7349 0.096 17.069
Section 2.3174 0.444 0.192 17.513
Non-Reflective 22 71.0522 0.252 17.765
Section 9.7697 1.730 0.177 19.494
Non-Reflective 23 80.8219 0.110 19.604
Section 4.0630 0.738 0.182 20.342

Signature: _______________________________ Date: 1/9/2024 Page 5 of 6


OTDR Report (1550 nm (9 µm)) Fail
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
Non-Reflective 24 84.8850 0.108 20.450
Section 5.0737 1.000 0.197 21.450
Reflective 25 89.9587 -2.373 -42.8 19.076
Section 4.8491 3.108 0.641 22.184
Non-Reflective 26 94.8078 0.391 22.575
Section 0.8218 0.556 0.677 23.131
Reflective 27 95.6296 --- -31.8 23.131

Macrobend
No macrobend detected.
Pass/Fail Thresholds
1550 nm (9 µm)
Splice loss (dB) 0.150
Connector loss (dB) 0.500
Splitter loss (dB) 4.500
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.400
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00

Test Parameters
A→B
Wavelength (nm) 1550 nm (9 µm)
Range (km) 120.0000
Pulse (μs) 2.5
Duration (s) 90

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325 1310 nm - 1550 nm 0.500
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 15.000

Signature: _______________________________ Date: 1/9/2024 Page 6 of 6