OTDR Report (1310 nm (9 µm))

General Information
File name: BI C012 F13 CORE85.trc
Test date: 2/11/2020 Customer:
Test time: 1:56:35 PM Company:
Cable ID: Fiber ID: 20
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model MAX-720C-SM1-EA
Serial number 1138696
Calibration date 7/10/2018 (UTC)

Results
Span length: 12.3411 km Average loss: 0.943 dB/km Injection level: 23.1 dB
Span loss: 11.632 dB Average splice loss: 0.084 dB
Span ORL: 32.25 dB Maximum splice loss: 0.273 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.326 dB/km A-B average loss: 0.330 dB/km
a 0.6000 22.939 A-B LSA loss: 0.196 dB 4-point Event Loss: -0.069 dB
A 1.2000 22.735 A-B ORL: 41.97 dB Maximum reflectance: -83.2 dB
B 1.8000 22.537
b 2.4001 22.247

Signature: _______________________________ Date: 2/11/2020 Page 1 of 3


OTDR Report (1310 nm (9 µm))

Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- -62.3 0.000
Section 2.0783 0.702 0.338 0.702
Non-Reflective 2 2.0783 0.094 0.795
Section 0.6760 0.219 0.323 1.014
Non-Reflective 3 2.7543 0.052 1.066
Section 1.8977 0.662 0.349 1.728
Positive 4 4.6520 -0.062 1.666
Section 1.7286 0.566 0.327 2.232
Non-Reflective 5 6.3806 0.273 2.505
Section 0.6753 0.229 0.339 2.734
Non-Reflective 6 7.0559 0.147 2.881
Section 1.0819 0.354 0.327 3.235
Positive 7 8.1378 -0.036 3.199
Section 1.2460 0.394 0.316 3.592
Non-Reflective 8 9.3838 0.154 3.747
Section 1.0111 0.339 0.335 4.085
Non-Reflective 9 10.3949 0.051 4.136
Section 0.8630 0.308 0.357 4.444
Reflective 10 11.2579 4.288 -56.6 8.732
Section 0.8809 0.322 0.365 9.054
Merged Events 11 12.1388 1.966 -29.7 11.020
Section 0.2023 0.612 3.025 11.632
Reflective 12 12.3411 --- -28.3 11.632
Section 0.1277 --- --- ---
Reflective 12.4688 --- -16.9 ---

Macrobend
Position (km) Delta Loss (dB)

Pass/Fail Thresholds
1310 nm (9 µm)

Test Parameters
A→B
Wavelength (nm) 1310 nm (9 µm)
Range (km) 15.0000
Pulse (ns) 50
Duration (s) 5

Signature: _______________________________ Date: 2/11/2020 Page 2 of 3


OTDR Report (1310 nm (9 µm))

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.467700
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 2/11/2020 Page 3 of 3


OTDR Report (1310 nm (9 µm))
General Information
File name: BI C012 F13 CORE83.trc
Test date: 2/11/2020 Customer:
Test time: 1:53:41 PM Company:
Cable ID: Fiber ID: 20
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model MAX-720C-SM1-EA
Serial number 1138696
Calibration date 7/10/2018 (UTC)

Results
Span length: 12.9463 km Average loss: 0.930 dB/km Injection level: 23.1 dB
Span loss: 12.042 dB Average splice loss: 0.379 dB
Span ORL: 32.31 dB Maximum splice loss: 3.642 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.334 dB/km A-B average loss: 0.368 dB/km
a 0.6000 23.061 A-B LSA loss: 0.200 dB 4-point Event Loss: -0.132 dB
A 1.2000 22.852 A-B ORL: 41.99 dB Maximum reflectance: -82.7 dB
B 1.8000 22.631
b 2.4001 22.274

Signature: _______________________________ Date: 2/11/2020 Page 1 of 3


OTDR Report (1310 nm (9 µm))

Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- -62.2 0.000
Section 0.2304 0.079 0.343 0.079
Positive 2 0.2304 -0.110 -0.030
Section 1.8454 0.640 0.347 0.609
Non-Reflective 3 2.0758 0.164 0.774
Section 0.6728 0.219 0.326 0.993
Non-Reflective 4 2.7486 0.132 1.125
Section 0.9670 0.322 0.333 1.448
Non-Reflective 5 3.7156 0.204 1.652
Section 0.9434 0.298 0.316 1.950
Positive 6 4.6590 -0.075 1.875
Section 1.7266 0.578 0.335 2.454
Non-Reflective 7 6.3857 0.075 2.529
Section 0.6683 0.219 0.328 2.748
Non-Reflective 8 7.0540 0.043 2.791
Section 1.0870 0.363 0.334 3.154
Non-Reflective 9 8.1410 0.137 3.290
Section 1.5779 0.502 0.318 3.793
Non-Reflective 10 9.7189 0.083 3.875
Section 0.6753 0.225 0.333 4.100
Non-Reflective 11 10.3943 0.064 4.164
Section 0.8598 0.300 0.349 4.464
Non-Reflective 12 11.2541 3.642 8.106
Section 0.8975 0.311 0.346 8.417
Non-Reflective 13 12.1516 0.186 8.602
Section 0.5132 0.181 0.353 8.783
Reflective 14 12.6648 0.535 -34.2 9.319
Section 0.0874 0.239 2.732 9.558
Reflective 15 12.7522 0.038 -33.7 9.596
Section 0.1072 0.115 1.075 9.711
Merged Events 16 12.8594 2.048 -33.4 11.759
Section 0.0868 0.283 3.259 12.042
Reflective 17 12.9463 --- -24.2 12.042

Macrobend
Position (km) Delta Loss (dB)

Pass/Fail Thresholds
1310 nm (9 µm)

Signature: _______________________________ Date: 2/11/2020 Page 2 of 3


OTDR Report (1310 nm (9 µm))

Test Parameters
A→B
Wavelength (nm) 1310 nm (9 µm)
Range (km) 15.0000
Pulse (ns) 50
Duration (s) 5

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.467700
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 2/11/2020 Page 3 of 3


OTDR Report (1310 nm (9 µm))
General Information
File name: BI C012 F13 CORE84.trc
Test date: 2/11/2020 Customer:
Test time: 1:55:45 PM Company:
Cable ID: Fiber ID: 20
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model MAX-720C-SM1-EA
Serial number 1138696
Calibration date 7/10/2018 (UTC)

Results
Span length: 12.7694 km Average loss: 1.184 dB/km Injection level: 22.4 dB
Span loss: 15.125 dB Average splice loss: 0.090 dB
Span ORL: 32.20 dB Maximum splice loss: 0.191 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.315 dB/km A-B average loss: 0.322 dB/km
a 0.6000 22.262 A-B LSA loss: 0.189 dB 4-point Event Loss: -0.151 dB
A 1.2000 22.082 A-B ORL: 42.00 dB Maximum reflectance: -79.8 dB
B 1.8000 21.889
b 2.4001 21.518

Signature: _______________________________ Date: 2/11/2020 Page 1 of 3


OTDR Report (1310 nm (9 µm))

Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- -59.4 0.000
Section 0.2202 0.069 0.315 0.069
Positive 2 0.2202 -0.078 -0.008
Section 1.8569 0.629 0.339 0.621
Non-Reflective 3 2.0771 0.148 0.769
Section 1.6417 0.586 0.357 1.355
Non-Reflective 4 3.7188 0.080 1.435
Section 2.6662 0.876 0.328 2.311
Non-Reflective 5 6.3850 0.191 2.502
Section 0.6747 0.226 0.334 2.727
Non-Reflective 6 7.0597 0.133 2.860
Section 1.0839 0.361 0.333 3.221
Positive 7 8.1436 -0.028 3.193
Section 1.5811 0.496 0.314 3.689
Non-Reflective 8 9.7247 0.132 3.822
Section 0.6715 0.220 0.328 4.042
Non-Reflective 9 10.3962 0.143 4.184
Section 0.8579 0.277 0.323 4.461
Reflective 10 11.2541 3.695 -57.5 8.156
Section 1.0762 0.491 0.456 8.647
Reflective 11 12.3303 0.562 -32.8 9.208
Section 0.0945 0.165 1.749 9.374
Reflective 12 12.4248 1.050 -33.6 10.424
Section 0.0549 0.000 0.000 10.424
Reflective 13 12.4797 1.244 -31.6 11.668
Section 0.0843 0.888 10.534 12.555
Reflective 14 12.5639 0.225 -29.5 12.780
Section 0.1028 1.224 11.913 14.004
Reflective 15 12.6667 0.168 -27.1 14.172
Section 0.1028 0.953 9.269 15.125
Reflective 16 12.7694 --- -27.1 15.125
Section 0.1423 --- --- ---
Merged Events 12.9118 --- -22.1 ---

Macrobend
Position (km) Delta Loss (dB)

Pass/Fail Thresholds
1310 nm (9 µm)

Signature: _______________________________ Date: 2/11/2020 Page 2 of 3


OTDR Report (1310 nm (9 µm))

Test Parameters
A→B
Wavelength (nm) 1310 nm (9 µm)
Range (km) 15.0000
Pulse (ns) 50
Duration (s) 5

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.467700
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 2/11/2020 Page 3 of 3