You are on page 1of 3

OTDR Report Fail

General Information
Filename: Nix''''1-8-3.trc
Test date: 1/8/2007 Customer:
Test time: 8:39:25 PM Company:
Cable ID: Fiber ID: Fiber9
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model FTB-730-23B-EA
Serial number 569649
Calibration date 1/31/2011 (UTC)

Results
Span length: 25.9912 km Average loss: 0.663 dB/km Injection level: 22.6 dB
Span loss: 17.230 dB Average splice loss: 0.596 dB
Span ORL: --- Maximum splice loss: 1.605 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.363 dB/km A-B average loss: 0.161 dB/km
a 7.9998 16.126 A-B LSA loss: 2.905 dB 4-point Event Loss: 2.940 dB
A 15.9995 9.319 A-B ORL: 35.55 dB Maximum reflectance: -58.4 dB
B 24.0005 8.033
b 32.0003 0.000

Signature: _______________________________ Date: 1/8/2007 Page 1 of 3


OTDR Report Fail
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- >-30.9 0.000
Section 1.2391 0.620 0.500 0.620
Non-Reflective 2 1.2391 1.605 2.224
Section 2.7027 1.250 0.463 3.474
Non-Reflective 3 3.9418 0.314 3.789
Section 1.0324 0.516 0.500 4.305
Non-Reflective 4 4.9742 1.197 5.502
Section 1.0311 0.452 0.438 5.953
Positive 5 6.0052 -0.219 5.734
Section 1.1293 0.285 0.252 6.019
Non-Reflective 6 7.1346 0.380 6.399
Section 2.2548 0.453 0.201 6.852
Non-Reflective 7 9.3894 0.269 7.121
Section 0.4032 0.135 0.335 7.256
Non-Reflective 8 9.7927 0.432 7.688
Section 0.3969 0.091 0.229 7.779
Non-Reflective 9 10.1895 0.389 8.168
Section 0.3701 0.039 0.106 8.207
Non-Reflective 10 10.5596 0.615 8.822
Section 1.2429 0.202 0.163 9.024
Non-Reflective 11 11.8025 1.522 10.546
Section 0.4275 0.071 0.165 10.617
Non-Reflective 12 12.2300 0.447 11.064
Section 3.2170 1.280 0.398 12.344
Non-Reflective 13 15.4470 0.491 12.834
Section 0.4747 0.047 0.100 12.881
Non-Reflective 14 15.9217 0.312 13.194
Section 10.0696 4.036 0.401 17.230
Reflective 15 25.9912 --- -25.8 17.230

Macrobend
Position (km) Delta Loss (dB)

Pass/Fail Thresholds
1550 nm
Splice loss (dB) 0.300
Connector loss (dB) 0.750
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.400
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00

Signature: _______________________________ Date: 1/8/2007 Page 2 of 3


OTDR Report Fail
Test Parameters
A→B
Wavelength (nm) 1550 (9 μm)
Range (km) 40.0000
Pulse (ns) 500
Duration (s) 30

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 1/8/2007 Page 3 of 3