Professional Documents
Culture Documents
General Information
Filename: Nix''''1-8-3.trc
Test date: 1/8/2007 Customer:
Test time: 8:39:25 PM Company:
Cable ID: Fiber ID: Fiber9
Job ID:
Comments:
Locations
Location A Location B
Location
Operator
Model FTB-730-23B-EA
Serial number 569649
Calibration date 1/31/2011 (UTC)
Results
Span length: 25.9912 km Average loss: 0.663 dB/km Injection level: 22.6 dB
Span loss: 17.230 dB Average splice loss: 0.596 dB
Span ORL: --- Maximum splice loss: 1.605 dB
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.363 dB/km A-B average loss: 0.161 dB/km
a 7.9998 16.126 A-B LSA loss: 2.905 dB 4-point Event Loss: 2.940 dB
A 15.9995 9.319 A-B ORL: 35.55 dB Maximum reflectance: -58.4 dB
B 24.0005 8.033
b 32.0003 0.000
Macrobend
Position (km) Delta Loss (dB)
Pass/Fail Thresholds
1550 nm
Splice loss (dB) 0.300
Connector loss (dB) 0.750
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.400
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00
Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000