*** DESIGN OF GRAVITY MAINS ***

Name of Work :- PROVIDING IRRIGATION FACILITY UNDER HP SHIVA PROJECT FOR CHAUNTRA,GOPALPUR AND DHARAMPUR BLOCKS, DISTRICT MANDI(HIMACHAL PRADESH)- PACKAGE-07
Name of Scheme:- LIS Churu Balh, Block Dharampur
GMS tube as per IS:1239 - 2004 (Part-I): MSERW Pipe IS/ISO:3183-2007 :
Mill Tolerance 12.5 % Mill Tolerance 12.5 %
Joint Efficiency, JE = 0.85 Joint Efficiency, JE = 0.85
Value of C 100 Value of C 140
Corrosion Allowance 1.65 mm Corrosion Allowance 1.5 mm
Yield Stress 320 Mpa Grade of pipe = L 210 or A
Allowable Fibre Stress 106.67 Mpa Yld. Stress 210 Mpa
(S = 1/3 x 320) Allowable Fibre Stress Factor 60 %
Allowable Fibre Stress (S) 126 Mpa

Sr. Name Of Line RD Length Water Design Prop. Dia Outer Dia Losses Velocity Total Hydraulic Level Ground level Terminal Static Class of Pipe Calculated Provided Flange Flange Remarks
No. From To requirement in requirement of Pipe of Pipe per in m/s losses in Upper End Lower End in Mts Head Head Wall thickness Pipe wall Table Table
LPS in LPD 1000m Mts as per Barlow Thickness in Required Provided
eqn in mm mm

MDT Churu Balh to MT 1


1 0 92 92 2.54 219790 65 76.6 22.01 0.81 2.03 745.284 743.254 737.345 5.91 7.94 GI Pipe (Medium) 1.69 3.60 5 5
Churu Balh
MDT Churu Balh to MT 2
2 0 446 446 2.54 219790 65 76.6 22.01 0.81 9.82 745.284 735.464 704.556 30.91 40.73 GI Pipe (Medium) 1.84 3.60 5 5
Churu Balh
NOTE:- Wherever the Velocity is below 0.6m/s, provide Scour-T at suitable locations.