You are on page 1of 7

ACO StormBrixx®

Online Project Configuration

Project Details Customer Details


Description : ACO VN_Sample Contact : Dat Nguyen
Date : 12-07-2023 Email : dat.nguyen@aco.com
City : Ho Chi Minh
State : Ho Chi Minh
Zip Code : 700000
Country : Vietnam

Tank Configuration
Tank Function Detention/Retention
3.6 m
Product Heavy Duty (HD) 7.2 m

Number of Layers 2.0

Total Net Volume (m³) 30.0 m³

Total Gross Volume (m³) 31.6 m³ 1.2 m

Length of Tank (m) 7.2 m

Width of Tank (m) 3.6 m

Depth of Tank (m) 1.2 m

Cavity & Excavation Details


Length of Cavity (m) 8.4 m

Width of Cavity (m) 4.8 m


4.82 m

Depth of Cavity (m) 1.9 m

Volume of Material to be 75.9 m³


Excavated (m³)

*Membrane Quantity 89.9 m²


(m²)
8.42 m
Cover Dimension (m) 0.5 m

**Backfill Material (m³) 44.3 m³


1.87 m
* Calculation includes a 15% overlap
** Pavement not accounted for * Diagram shows cavity size rounded to nearest foot

134-140 Old Bathurst Road Tel : +612 (4747) 4000


© ACO Pty Ltd P.O. Box 470, Emu Plains NSW 2750 sales@acoaus.com.au
Project Configuration Inlets, Outlets, and Access

Inlets
Qty Grid Note
The grids below do not represent accurate dimensions
Inlets 1 or proportions they just give a general guide to both
inlet / outlet and access placement on your StormBrixx
scheme.
Remote Access Unit 1

Side Panels 0

Horizontal Pipe
0
Connector

Outlets
Qty

Outlets 1

Remote Access Unit 1

Side Panels 0

Inlet/Outlet Grid Key


Horizontal Pipe
0 Inlet/Outlet using
Connector Inlet/Outlet Pipe
Remote Access Unit

Access Grid Key

Remote Access Unit with Remote Access Plate with


maintenance access maintenance access
Access
Qty

Access Points 2

Remote Access Unit 2

Remote Access Plate 0

134-140 Old Bathurst Road Tel : +612 (4747) 4000


© ACO Pty Ltd P.O. Box 470, Emu Plains NSW 2750 sales@acoaus.com.au
Bill of Materials
Weight
Price Extended Price Each Extended
Pt No. Description Qty Each ($) ($) (lbs) Weight (lbs)

314061 HD Half-Module 144 22.40 3,225.6

314062 HD Side Panel 72 3.79 272.9

Stormbrixx Universal
140213 72 1.79 128.9
top cover

314023 HD Layer Connectors 108 0.03 3.2

HD Remote Access
27034 8 70.50 564.0
Unit

314038 Extension Shaft 4 4.84 19.4

Remote Access Cover


314043 2 86.46 172.9
- Ductile Iron

Vertical Inspection
27018 1 5.52 5.5
Point Connector

Inspection Point
314044 1 34.54 34.5
Cover - Ductile Iron

Horizontal Pipe
93146 1 3.29 3.3
Connector 6" SCH 40

Horizontal Pipe
93147 1 4.31 4.3
Connector 8" SCH 40

Totals Price Weight 4,434.5

Notes:
1) These prices are the manufacturer's suggested retail price (MSRP). Please contact your local dealer or ACO Customer
Service for more information.

2) You should have received an email with your output results from: no-reply@acosbconfigurator.com If you do not
receive the confirmation within a few minutes, please check your spam folder.

134-140 Old Bathurst Road Tel : +612 (4747) 4000


© ACO Pty Ltd P.O. Box 470, Emu Plains NSW 2750 sales@acoaus.com.au
ACO StormBrixx® HD February 2021

Stormwater Detention/Infiltration/Retention System


HD Half-Module
part no. 314061

24.00" (609 mm)


13.50" (343 mm)
12.00" (304 mm)

ACO Spe c if ic ation Infor ma ti o n


4.38" (111 mm) 4.30" (109 mm)

47.44" (1205 mm) 23.62" (600 mm)

(320 mm)
12.60"

12.60" 11.02"
(320 mm) (280 mm)

HD Side Panel 1.57" HD Top Cover


part no. 314062 (40 mm) part no. 314022
Ø 4.49" (114 mm)

12.60" (320 mm)


23.62" (600 mm)

23.62" (600 mm) 21.57" (548 mm) 1.69" (43 mm)


3.31"
(84 mm)

HD Half-Layer Side Panel


part no. 314095 1.26"
(32 mm)
11.67" (297 mm)

23.31" (592 mm)


3.75"
(95 mm)

West Tel: (888) 490-9552 1 www.acostormbrixx.us


134-140 Old Bathurst Road Tel : +612 (4747) 4000
©East
ACOTel:
Pty(800)
Ltd 543-4764 P.O. Box 470, Emu Plains NSW 2750
info@acousa.com
sales@acoaus.com.au
ACO StormBrixx® HD January 2021

Stormwater Detention/Infiltration/Retention System

Half-Layer Top Cover Plate


part no. 314094 3.70" (94 mm)

23.66" (601 mm)

ACO Spe c if ic ation Infor ma ti o n


1.50" (38 mm)

11.02" 12.60" 1.57" (40 mm)


(280 mm) (320 mm)
47.28" (1201 mm)

Horizontal Pipe Connector


part no. see chart
Part A B C H W L
No. in (mm) in (mm) in (mm) in (mm) in (mm) in (mm)
W L
2.00 6.25 8.25 6.70 8.00
93139 SDR 35 - 4"
B (51) (158) (209) (170) (203)

2.00 7.47 8.29 6.70 8.00


93145 SCH 40 - 4"
(51) (189) (210) (170) (203)
H C
A 2.00 8.95 9.93 10.22 8.00
93140 SDR 35 - 6"
(51) (227) (252) (259) (203)

2.00 9.11 9.93 10.22 8.00


93146 SCH 40 - 6"
(51) (231) (252) (259) (203)

2.00 10.46 11.39 11.64 8.00


93141 SDR 35 - 8"
(51) (265) (289) (295) (203)

2.00 10.57 11.39 11.64 8.00


93147 SCH 40 - 8"
(51) (268) (289) (295) (203)

2.00 13.48 14.30 16.66 8.00


93142 SDR 35 - 12"
(51) (342) (363) (423) (203)

2.00 18.61 19.25 19.25 8.00


93144 SCH 35 - 15"
(51) (471) (489) (489) (203)

Remote Access Cover (Vented) Remote Access Cover (Non-Vented) Inspection Point Cover
part no. 314053 part no. 314043 part no. 314044 Ø 7.67” (195 mm)

Ø 8.85” (225 mm)


2.95” (75 mm)

18.19" (462 mm)


Ø 12.00” (305 mm)
17.40" (442 mm)
(110 mm)
4.33"

20.79" (528 mm)

West Tel: (888) 490-9552 2 www.acostormbrixx.us


134-140 Old Bathurst Road Tel : +612 (4747) 4000
©East
ACOTel:
Pty(800)
Ltd 543-4764 P.O. Box 470, Emu Plains NSW 2750
info@acousa.com
sales@acoaus.com.au
ACO StormBrixx® HD January 2021

Stormwater Detention/Infiltration/Retention System

Remote Access Plate 4.72"


part no. 314075 (120 mm)

14.76" (375 mm)

25.59" (650 mm)

23.54" (598 mm)


(286 mm)
11.26"

ACO Spe c if ic ation Infor ma ti o n


25.59" (650 mm) 0.79"
(20 mm)

HD Remote Access Unit HD Remote Access Unit with Adapter Plate


part no. 27034 part no. 138140

23.39" (594 mm)


13.98" (355 mm)
23.39" (594 mm)

Ø 18.11" (460 mm)


16.93" (430 mm)

1.97" (50 mm) 23.39" (594 mm)

Extension Shaft Extension Shaft with Pipe Socket Vertical Inspection Point Connector
part no. 314038 part no. 314039 part no. 27018
17.20" (437 mm)

17.20" (437 mm)

23.62" (600 mm)

Ø 8.85"
2.08"(53 mm)
(225 mm)
13.77" (350 mm)

10.23"
(160 mm)
Ø 6.29"

(260 mm)
(200 mm)
7.87"
(6 mm)
0.23"

Ø 13.77"
(350 mm)

West Tel: (888) 490-9552 3 www.acostormbrixx.us


134-140 Old Bathurst Road Tel : +612 (4747) 4000
©East
ACOTel:
Pty(800)
Ltd 543-4764 P.O. Box 470, Emu Plains NSW 2750
info@acousa.com
sales@acoaus.com.au
ACO StormBrixx® HD January 2021

Stormwater Detention/Infiltration/Retention System

ACO StormBrixx HD Part Length Width Depth Weight Specifications


Parts Table No. in (mm) in (mm) in (mm) lbs (kg)
General
The StormBrixx stormwater Detention*/
HD Half-Module 314061 47.44 (1205) 23.70 (602) 13.50 (343) 22.40 (10.20)
Infiltration*/Retention* system shall be ACO
Stormbrixx HD as supplied by ACO, Inc.
HD Side Panel 314062 23.62 (600) 23.62 (600) 2.17 (55) 3.79 (1.72)

ACO Spe c if ic ation Infor ma ti o n


ACO StormBrixx HD meets AASHTO H-25 and
HD Top Cover 314022 21.57 (548) 21.57 (548) 1.70 (43) 1.79 (0.81) HS-25 loading conditions.

HD Half-Layer Side Panel 314095 23.31 (592) 11.67 (297) 1.26 (32) 1.98 (0.90) Materials
The half-module shall be manufactured from
Half-Layer Top Cover Plate 314094 47.25 (1200) 23.63 (600) 3.70 (94) 7.70 (3.50) polypropylene and have minimum properties
as follows:
HD Layer Connector 314023 3.94 (100) 1.58 (40) 1.82 (46) 0.03 (0.02) Tensile impact strength:
152 ft-lb/in2 (319 kj/m2)
Remote Access Plate 314075 25.59 (650) 25.59 (650) 4.72 (120) 10.78 (4.90) Tensile strength, ultimate:
3,480 psi (23,994 kpa)
Water absorption: 0.01%
HD Remote Access Unit 27034 23.39 (594) 23.39 (594) 24.02 (610) 70.50 (31.98)
Frost proof, salt proof and fuels and oils
HD Remote Access Unit with Adapter resistant
138140 24.41 (620) 23.39 (594) 24.02 (610) 71.00 (32.21)
Plate
The stormwater tank shall provide an average
Remote Access Cover- Ductile Iron 95% open area1, holding up to 14.731 ft3 (0.42
314043 - Ø 20.79 (528) 4.34 (110) 86.46 (39.30)
(Load Class D400) m3) per module (2 half-modules assembled)
and offer full access to all areas and levels for
Remote Access Vented Cover maintenance.
314053 - Ø 20.79 (528) 4.34 (110) 83.60 (38.00)
Ductile Iron (Load Class D400)
Inspection Point Cover - Ductile Iron Geomembranes/Geotextiles
314044 - Ø 8.85 (225) 2.95 (75) 34.54 (15.70) The StormBrixx stormwater system shall be
(Load Class D400)
wrapped in appropriate permeable geotextile
Extension Shaft 314038 - Ø 17.21 (437) 13.78 (350) 4.84 (2.60) or impermeable geomembrane* (supplied
by others) as indicated by project design
engineer.
Extension Shaft with Pipe Socket 314039 - Ø 17.21(437) 13.78 (350) 6.16 (2.80)
Accessories
Vertical Inspection Point Connector 27018 - Ø 8.85* (225) 7.87 (200) 5.52 (2.50)
The StormBrixx stormwater system shall be
used in conjunction with remote access unit
Horizontal Pipe Connectors
or plate**/extension shaft**/inspection point
SDR 35 - 4" 93139 4.00* (102) 1.9 (0.87) connector**.
SCH 40 - 4" 93145 4.00* (102) 1.9 (0.87)
SDR 35 - 6" 93140 6.00* (152) 3.2 (1.49) Installation
The StormBrixx stormwater system shall
SCH 40 - 6" 93146 8.00 (203) 6.00* (152) - 3.20 (1.49) be installed in strict accordance with the
SDR 35 - 8" 93141 8.00* (203) 5.52 (2.50) manufacturer’s installation instructions and
SCH 40 - 8" 93147 8.00* (203) 5.52 (2.50) recommendations.
SDR 35 - 12" 93142 12.00* (305) 5.52 (2.50) *Choose one
SDR 35 - 15" 93144 15.00* (381) 5.52 (2.50) **Choose none, one or more
1
Configuration and use of side/top panels will
*Internal width
marginally impact these figures

ACO, Inc.

West Sales Office Northeast Sales Office Southeast Sales Office info@acousa.com
825 W. Beechcraft Street 9470 Pinecone Drive 4211 Pleasant Road www.acousa.com
Casa Grande, AZ 85122 Mentor, OH 44060 Fort Mill, SC 29708
Tel: (520) 421-9988 Tel: (440) 639-7230 Toll-Free: (800) 543-4764
Toll-Free: (888) 490-9552 Toll-Free: (800) 543-4764 Fax: (803) 802-1063
Fax: (520) 421-9899 Fax: (440) 639-7235

© February 2021 ACO, Inc.


All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the
use of ACO products are made without guarantee since the conditions of use are beyond the control of the company. It is the
customer's responsibility to ensure that each product is fit for its intended purpose and that the actual conditions of use are suit- ACO. creating
able. ACO, Inc. reserves the right to change products and specifications without notice. the future of drainage

West Tel: (888) 490-9552 4 www.acostormbrixx.us


134-140 Old Bathurst Road Tel : +612 (4747) 4000
©East
ACOTel:
Pty(800)
Ltd 543-4764 P.O. Box 470, Emu Plains NSW 2750
info@acousa.com
sales@acoaus.com.au
Powered by TCPDF (www.tcpdf.org)

You might also like