You are on page 1of 1

Thermal design summary...

Heat exchanger Superheater

Hot fluid Cold fluid


______________________________________________________________________
Fluid type Flue gas Superheated steam
Shell/tube Shell side Tube side
Flow Mixed Unmixed
Flow regime Laminar Turbulent
Mass flow 28078.080 14286.000 kg/hour
Velocity 2.606 0.720 m/s
Inlet temperature 804.891 283.034 °C
Outlet temperature 678.036 404.085 °C
Rated temperature 398.900 °C
Heat transfer coefficient 61.660 156.638 W/m² K
Reynolds number 990.617 38789.137

Mass flow 61901.570 31495.238 lb/hour


Velocity 512.894 141.726 fpm
Inlet temperature 1480.804 541.461 °F
Outlet temperature 711.836 759.354 °F
Rated temperature 750.020 °F

Heat exchanger data...


Required duty 1545.376 kW 5273.039 MBH
Theoretical duty 1584.034 kW 5404.946 MBH
Heat transfer coefficient- new 41.808 W/m².K 7.363
BTH/ft²/F
HTC- fouled 38.783 W/m².K 6.830
BTH/ft²/F
Gas side fouling 1.7611 m²K/kW 9.9995
°Fft²/MBH
Tube side fouling 0.0880 m²K/kW 4.9969E-1
°Fft²/MBH
Atmospheric pressure 96.320 kPa 13.971 psi
Heat transfer area (tube OD) 107.828 m² 1160.644 ft²
Temperature difference 378.856 °C 713.940 °F
______________________________________________________________________
Notes...
Normal Pressure 101.325 kPa 14.696 psi
Normal Temperature 0 °C 32 °F
Normal Temperature 273.15 K 491.68 R
AMCA (fans) standard for air...
Pressure 101.325 kPa 14.696 psi
Pressure 759.969 mm Hg 29.921 in Hg
Density 1.202 kg/m³ 7.500E-2 lb/ft³
Temperature 21.112 °F 70.000 °C