You are on page 1of 9

Gas Flow Rate

GAS FLOW RATE Mol.Wt 22.00


MASS FLOW MOL FLOW GAS VOLUME FLOW
lb/hr kg/hr kmol/hr Nm3/hr Sm3/hr SCMD SCFD MMSCFD MMSCMD
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
2916.891 1323.102 60.141 1348.000 1424.836 34196.064 1207599.804 1.208 0.034
285417.343 129465.307 5884.787 131901.608 139420.000 3346080.000 118163469.120 118.163 3.346
12794.853 5803.745 263.807 5912.961 6250.000 150000.000 5297100.000 5.297 0.150
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
3888.866 1763.990 80.181 1797.185 1899.624 45590.984 1610000.000 1.610 0.046
383845.587 174112.358 7914.198 177388.836 187500.000 4500000.000 158913000.000 158.913 4.500

Page 1
Gas Actual Vol
P kPa 8375
n kmol 6226.852
Z 0.7784
R J/mol.K 8.31447 (standard)
T K 323.29
V m3 1555.655
mol = Mass/Mol.wt

Gas Actual Vol


kg/hr 100
kg/m3 1000
m3/hr 0.1
Liquid Flow Rate

LIQUID FLOW RATE


density,kg/m3 1000
kg/hr 1925000
m3/hr 1925
BLPD 290589.2576

Page 3
Viscosity

Kinematic viscosity to Dynamic Viscosity


cSt 8.968
Kinematic Viscosity
m2/s 8.968E-06
Kg/m3 2.134
Density
kg/m.s 1.9137712E-05
Dynamic Viscosity g/cm.s 0.00019137712
cP 0.019137712

Page 4
Mixture Density

HC flow rate m3/h 235


Water flowrate m3/h 1.2

HC Density kg/m3 915


Water Density kg/m3 996

Mixture density kg/m3 915.4115


Mixture Sp.Gr 0.915412

Total flow rate m3/h 236.2


Design Conditions for Equipment and Piping (NORSOK)
Design Temp = Op. Temp + 30 C

Design Pr
upto 35 bar = Op. Pr + 3.5 bar
above 35 bar = Op. Pr + 10% of Op. Pr.

Upto 35 bar
Op. Pr. bar 32
Design Pr. bar 35.500

above 35 bar
Op. Pr. bar 91.68
Design Pr. bar 100.848

Op. Temp C 204


Design Temp C 234
Set Point Schedule
Pressure Temperatue Flow
Design pressure 48 Design Temp 120 Normal flow 2720
Operating pressure 41 Operating Temp 41 FAH 3128
PAHH 43.2 TAHH 108 FAL 2176
PAH 38.4 TAH 84
PAL 36.9 TAL 36.9
PALL 32.8 TALL 28.7 Flow
Normal flow 2720
FAH 3128
Notes: HH, H is always greater than operating conditions FAL 2448
LL, L is always less than operating conditions FALL 1904

PDI
Diff. press 1
H 1.15
L 0.8
Power Watt kWatt
Btu/hr 559854 164077.0 164.077
kcal/hr 141175 164076.7 164.077
kJ/hr 589999.4 163888.2 163.888
Heat Capacity