Lutron Non-Plenum QS Cable Accessories

369597g 1 02.09.2022

GRX-CBL-346S Cable

Non-Plenum rated cable for use with the following


Lutron systems: 18 AWG (0.75 mm2)

– GRAFIK Eye 3000 18 AWG (0.75 mm2)


– GRAFIK Eye 4000
– GRAFIK Eye QS
22 AWG (0.25 mm2)
– LCP128
– Softswitch128 22 AWG (0.25 mm2)
– Quantum
– Athena
TWP
– HomeWorks
– Energi Savr Node 24 AWG (0.2 mm2) Drain
– Sivoia QS, Sivoia QS Wireless, and
Contract Roller QS 0.21 in (5.3 mm)

Specifications
• Model number:
GRX-CBL-346S-500 – 500 ft (150 m) spool
• Listed as type CL3R or CMR cULus.
• Five stranded conductors:
Common – 18 AWG (0.75 mm2)
Power – 18 AWG (0.75 mm2)
MUX Data – 22 AWG (0.25 mm2)
}
_ Data – 22 AWG (0.25 mm2) Twisted wire pair
12 AWG (4.0 mm2)

Drain Wire – 24 AWG (0.2 mm2)* 12 AWG (4.0 mm2)


• Total outer jacket diameter: 0.21 in (5.3 mm).
• 300 V rated.
• PVC sheath, 75 °C rated.
• UL Listed.
18 AWG (0.75 mm2)
• Rated FT4.
• cULus or CSA Listed.
• CPR Classification: ECA 22 AWG (0.25 mm2)
• Capacitance of 22 AWG (0.25 mm2) twisted
wire pair: 22 AWG (0.25 mm2)
– Conductor to shield: 48 pf/ft max
– Conductor to conductor: 25 pf/ft max TWP
Note: Control link wiring distance maximums and other limitations for GRX-CBL-346S cable are the same as those for GRX-PCBL-346S
(plenum rated) cable and QS-CBL-LSZH (low-smoke zero-halogen rated) cable. Please refer to the24 AWG (0.2
Product mm2) Drain
Specification Submittal
Sheets or Product Installation Guides at www.lutron.com for details.
* Drain wire is not stranded. 0.325 in (8.25 mm)

® S P E C I F I C AT I O N S U B M I T TA L Page 1
Job Name: Model Numbers:

Job Number:
Lutron Non-Plenum QS Cable Accessories
369597g 2 02.09.2022

GRX-CBL-46L Cable

Non-Plenum rated cable for use with the following


12 AWG (4.0 mm2)
Lutron systems:
– GRAFIK Eye 3000 12 AWG (4.0 mm2)
– GRAFIK Eye 4000
– GRAFIK Eye QS
– LCP128
– Softswitch128 18 AWG (0.75 mm2)
– Quantum
– Athena
– HomeWorks 22 AWG (0.25 mm2)
– Energi Savr Node
22 AWG (0.25 mm2)
– Sivoia QS, Sivoia QS Wireless, and
Contract Roller QS
TWP
Specifications 24 AWG (0.2 mm2) Drain
• Model numbers:
GRX-CBL-46L-250 – 250 ft (75 m) spool 0.325 in (8.25 mm)
GRX-CBL-46L-500 – 500 ft (150 m) spool
• Listed as type CL3R or CMG cULus.
• Six stranded conductors:
Common – 12 AWG (4.0 mm2)
Power – 12 AWG (4.0 mm2)
MUX Data – 22 AWG (0.25 mm2)
}
_ Data – 22 AWG (0.25 mm2) Twisted wire pair
Sense Line – 18 AWG (0.75 mm2)
Drain Wire – 24 AWG (0.2 mm2)*
• Total outer jacket diameter: 0.325 in (8.25 mm).
• 300 V rated.
• PVC sheath, 75 °C rated.
• UL Listed.
• Rated FT4.
• cULus or CSA Listed.
• CPR Classification: ECA
• Capacitance of 22 AWG (0.25 mm2) twisted
wire pair:
– Conductor to shield: 48 pf/ft max
– Conductor to conductor: 25 pf/ft max
Note: Control link wiring distance maximums and other limitations for GRX-CBL-46L cable are the same as those for GRX-PCBL-46L (plenum
rated) cable. Please refer to the Product Specification Submittal Sheets or Product Installation Guides at www.lutron.com for details.
* Drain wire is not stranded.

® S P E C I F I C AT I O N S U B M I T TA L Page 2
Job Name: Model Numbers:

Job Number:
Lutron Non-Plenum QS Cable Accessories
369597g 3 02.09.2022

QSH-CBL-L-500 Cable

Non-Plenum rated cable for use with the following 12 AWG (4.0 mm2)
Lutron systems:
– GRAFIK Eye 3000
– GRAFIK Eye 4000 12 AWG (4.0 mm2)
– GRAFIK Eye QS
– LCP128
– Softswitch128
– Quantum
– Athena
22 AWG (0.25 mm2)
– HomeWorks
– Energi Savr Node 22 AWG (0.25 mm2)
– Sivoia QS, Sivoia QS Wireless, and
Contract Roller QS TWP

Specifications 24 AWG (0.2 mm2) Drain

• Model number:
0.31 in (7.9 mm)
QSH-CBL-L-500 – 500 ft (150 m) spool
• Listed as type CL3R.
• Five stranded conductors:
Common – 12 AWG (4.0 mm2)
Power – 12 AWG (4.0 mm2)
MUX Data – 22 AWG (0.25 mm2)
_ Data – 22 AWG (0.25 mm2)
}
Twisted wire pair

Drain Wire – 24 AWG (0.2 mm2)*


• Total outer jacket diameter: 0.31 in (7.9 mm).
• 300 V rated.
• PVC sheath, 90 °C rated.
• UL Listed.
• Rated FT6.
• CPR Classification: ECA
• Capacitance of 22 AWG (0.25 mm2) twisted
wire pair:
– Conductor to shield: 37 pf/ft max
– Conductor to conductor: 21.5 pf/ft max
Note: Please refer to the Product Specification Submittal Sheets or Product Installation Guides at www.lutron.com for control link wiring
distance maximums and other limitations.
* Drain wire is not stranded.

® S P E C I F I C AT I O N S U B M I T TA L Page 3
Job Name: Model Numbers:

Job Number:
Lutron Non-Plenum QS Cable Accessories
369597g 4 02.09.2022

QSH-CBL-M-500 Cable

Non-Plenum rated cable for use with the following


Lutron systems: . mm2)
16 AWG (1.0

– GRAFIK Eye 3000 16 AWG (1.0 mm2)


– GRAFIK Eye 4000
– GRAFIK Eye QS
22 AWG (0.25 mm2)
– LCP128
– Softswitch128 22 AWG (0.25 mm2)
– Quantum
– Athena
TWP
– HomeWorks
– Energi Savr Node 22 AWG (0.25 mm2) Drain
– Sivoia QS, Sivoia QS Wireless, and
Contract Roller QS 0.26 in (6.6 mm)

Specifications
• Model number:
QSH-CBL-M-500 – 500 ft (150 m) spool
• Listed as type CL3R or CMR cULus.
• Five stranded conductors:
Common – 16 AWG (1.0 mm2)
Power – 16 AWG (1.0 mm2)
MUX Data – 22 AWG (0.25 mm2)
_ Data – 22 AWG (0.25 mm2) Twisted wire pair}
12 AWG (4.0 mm2)
Drain Wire – 22 AWG (0.25 mm2)*
• Total outer jacket diameter: 0.26 in (6.6 mm).
• 300 V rated.
12 AWG (4.0 mm2)
• PVC sheath, 90 °C rated.
• Rated FT6.
• cULus Listed.
• CPR Classification: ECA
• Capacitance of 22 AWG (0.25 mm2) twisted
wire pair: 22 AWG (0.25 mm2)
– Conductor to shield: 37 pf/ft max
22 AWG (0.25 mm2)
– Conductor to conductor: 23.9 pf/ft max
Note: Please refer to the Product Specification Submittal Sheets or Product Installation Guides at www.lutron.com for control link wiring
distance maximums and other limitations. TWP
* Drain wire is not stranded. 24 AWG (0.2 mm2) Drain

0.31 in (7.9 mm)

Lutron, the Lutron logo, GRAFIK Eye, GRAFIK 6000, Softswitch128, HomeWorks, Energi Savr Node, GRAFIK 5000, GRAFIK 7000, HomeWorks Interactive, LCP128, Athena, and
Quantum are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries.

® S P E C I F I C AT I O N S U B M I T TA L Page 4
Job Name: Model Numbers:

Job Number: