Job Name/Location: Tag #:

Date: For: File Resubmit


PO No.: Approval Other
Architect: GC:
Engr: Mech:
Rep:
(Company) (Project Manager)

ARUM320LTE5 Multi (a) ARUM120LTE5


V™ 5 Dual Frame 380V (b) ARUM200LTE5
32.0 HP Outdoor Unit for Heat Pump and Heat Recovery
Performance: Operating Range:
Cooling Mode:
Cooling (˚C DB)** -10 – 48
Nominal Capacity (Btu/h) 305,700 Heating (˚C WB) ‐25 – 18
Power Input¹ (kW) 20.35 Synchronous
Cooling Based (˚C DB) -10 – 27
Heating Mode: Heating Based (˚C WB) -10 – 16
Nominal Capacity (Btu/h) 351,000
Unit Data:
Power Input¹ (kW) 20.20
Refrigerant Type R410A
Nominal Capacity is outside the scope of AHRI Standard 1230 and based on the following conditions:
Indoor: 80°F DB / 67°F WB Indoor: 70°F DB Refrigerant Control EEV
Outdoor 95°F DB Outdoor 47°F DB / 43°F WB
: : Max Number of Indoor Units³ 52
Electrical: (a) ARUM120LTE5 (b) ARUM200LTE5 Sound Pressure⁴ dB(A) 63.8
Power Supply (V/Hz/Ø) 380/60/3 380/60/3 Net Unit Weight (a) + (b) (kg) 215+300
MFA (A) 32 50 Shipping Weight (a) + (b) (lbs) 225+310
MCA (A) 25.5 44.5
Communication Cable⁵ (No x AWG) 2 x 18
Rated Amps (A) 12.4 20.9
Heat Exchanger Coating Black Coated Fin™
Compressor A (A) 9.9 9.2
Compressor B (A) ‐ 9.2 Compressor:
Fan (A) 2.5 2.5 Type HSS DC Scroll
Quantity 3
Piping: (a) ARUM120LTE5 (b) ARUM200LTE5
Oil/Type PVE/FVC68D
Refrigerant Charge (kg) 9.5 16
Liquid Line² (in, OD) 1/2
Fan:
5/8
Type Propeller
Vapor Line High² (in, OD) 1- 1/8 1‐1/8
Quantity 3
Heat Recovery Only
Motor/Drive Brushless Digitally Controlled/Direct
Vapor Line Low² (in, OD) 3/4 7/8
Air Flow Rate (CFM) 19,777
Standard Features: Notes:
•Advanced Smart Load Control •Fault Detec on and Diagnosis 1.For main pipe segment size, refer to the LATS Mul V tree diagram.
2.The combina on ra o must be between 50‐130%.
•Intelligent Heating •Active Refrigerant Control 3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745 for the
•HiPOR (high pressure oil return) •Variable Path Heat Exchanger combination of outdoor units.
4.All communication cable to be minimum 18 American wire gage (AWG), 2‐conductor,
•Smart Oil Control •Subcooling and Vapor Injection stranded, shielded or unshielded wire and must comply with applicable local and national
•Night Quiet Opera on Control code. If shielded, the wire must be grounded to the chassis at the outdoor unit only.
5.Nominal data is rated 0 above sea level, with 25 of refrigerant line per indoor unit and
•Liquid Cooled Inverter Controller a 0 ft level difference between outdoor and indoor units. All capacities are net with a
Required Accessories: combination ratio between 95‐105%.
6.Power wiring cable size must comply with the applicable local and na onal code. Cables
ARCNB21 (frame connector Y‐branch) terminate at each frame.
7.The voltage tolerance is 342‐415V.
8.The order of each of these units on the submittal (i.e., A+B) do not represent the installation
Optional Accessories: order. Highest capacity unit is used as the Master, followed by the next smaller size as Slave
1 and so on.
Air Guide ‐ ZAGDKA52A (2 required)
Hail Guard Kit ‐ ZHGDKA52A (2 Required)
Low Ambient Baffle Kit ‐ ZLABKA52A (2), Control Kit ‐ PRVC2 (1 per system)

**(‐9.9°F achieved only when all IDU's are operating in cooling mode.
Does not impact synchronous operating range.)
LG Electronics Perú S.A. www.lg.com.pe / www.lgaircon.com
© LG Electronics PERÚ S.A., Av. República de Colombia 791 Piso 12 San Isidro / Lima - Perú SB_MultiV_5_ODU_ARUM320LTE5_06_17 Page 1 of 3
Job Name/Location:
Tag #:
ARUM320LTE5 (a) ARUM120LTE5
Multi V™ 5 Dual Frame 380V (b) ARUM200LTE5 Date:
32.0 HP Outdoor Unit for Heat Pump and Heat Recovery PO No.:

1240
GGGGn™ˆ› G—–•›

LG Electronics Perú S.A. www.lg.com.pe / www.lgaircon.com


© LG Electronics PERÚ S.A., Av. República de Colombia 791 Piso 12 San Isidro / Lima - Perú SB_MultiV_5_ODU_ARUM320LTE5_06_17 Page 2 of 3