You are on page 1of 5

Task 2024

G12 ~ Engineering Graphics and Design

Tasks: Course drawings

ENGINEERING GRAPHICS AND DESIGN


GRADE 12 TASK DESCRIPTION
GRADE 12
ENGINEERING GRAPHICS AND DESIGN
TASKS FOR THE YEAR

INSTRUCTIONS Task Description Total Workbook Study guide


Term 1
1. All the work of each chapter must be completed first, before the formal task is done.
2. The drawings must ONLY be drawn on the drawing sheets in the Impaq-printed A3 Task 1.1 1st Mechanical assembly 20 p. 10 – 11 p. 2-2 – 2-29
workbook and not with CAD or any workbook other than Impaq’s. The publisher has
Task 1.2 Mechanical analytical 10 p. 7 p. 2-2 – 2-29
developed the workbook specifically for Impaq's clients. (RENEWED EVERY YEAR)
3. NO part of the Impaq printed A3 workbook may be reproduced or transmitted in any p. 3-2 – 3-9 &
Task 1.3 Civil detailed section 20 p. 40 – 41
form or by any means without permission in writing from the publisher. This includes p. 3-13 – 3-25
electronic or mechanical, including photocopying, recording, or any information storage p. 3-2 – 3-9 &
Task 1.4 Civil floor plan with elevation(s) 20 p. 40 – 41 Continues
and retrieval system. All rights reserved © JP p. 3-13 – 3-25
4. Under no circumstances may the memorandum be seen, used or copied from. Task 1.5 Civil site plan analytical 10 p. 30 p. 3-10 – 3-12
5. Take note:
Task 1.6 Two-point perspective 10 p. 52 p. 4-2 – 4-9
• Impaq-printed A3 workbook (ONLY provided by Impaq)
• Loosen the drawing sheets and draw the sketches on it. Term 2
• NO extra formal task drawing sheets are provided by Impaq. Task 3.1 Isometric drawing 10 p. 63 p. 5-2 – 5-14
• The page numbers of each formal task as well as the corresponding study
guide pages for reference, are indicated in the table on the right. Task 3.2 Solid geometry 10 p. 65 p. 6-2 – 6-15
p. 7-2 – 7-27 &
Due date Refer to platform for due dates. Task 3.3 Interpenetration & development 10 p. 82
p. 8-2 – 8-8
Method of assessment Memorandum
Task 3.4 2nd Mechanical assembly 20 p. 20 – 21 p. 2-2 – 2-29
Contact Contact the subject specialist at 087 405 2233 or send an email to
info@impaq.co.za Term 3
Important • Impaq-printed A3 workbook • Final formal
Task 5.1 Loci (Cam) 10 p. 106 p. 10-2 – 10-18
documentation and • HSECC, Engineering Graphics and drawing
proof Design Textbook for Grade 12 CAPS; Task 5.2 1st Loci (Mechanism) 10 p. 124 p. 11-2 – 11-3
Johan Engelbrecht. (Study guide) Task 5.3 2nd Loci (Mechanism) 10 p. 125 p. 11-2 – 11-3
Requirements • Standard drawing equipment for EGD is required
to complete the task. Task 5.4 Loci (Helix) 10 p. 115 p. 9-2 – 9-9
• A non-programmable calculator may be used. Task 5.5 3rd Mechanical assembly 20 p. 22 – 23 p. 2-2 – 2-29
• The study guide may be used for reference.
Additional guidelines • Read the instructions and assignment thoroughly. An additional assessment only Impaq-printed A3 workbook, which contains only the formal task
• All construction must be shown on the drawings, as well as all drawing sheets, can be ordered at own cost, if necessary, at 087 405 2233
calculations where applicable. or send an e-mail to info@impaq.co.za
• Drawings must be neat and accurate.
• Include the necessary information on the drawings and drawing
sheets.
• This is individual work.

Page 1 of 1 © Impaq
DOOR & WINDOW SCHEDULE QUESTION: CIVIL DRAWING
ELECTRICAL ROOF NOTES:
TO FIT SYMBOLS ROOF PITCH 15° WITH 200 x 20 mm FASCIA
BOARD ON ALL SIDES Given:
* The incomplete west elevation of new public toilets, showing the
ROOF COVER 15 mm FIBRE CEMENT SHEET ON
75 x 50 mm PURLINS @ 900 mm c/c
walls, the roof and notes
FASCIA BOARD
WINDOW OPENING * The incomplete floor plan showing the walls, position of the doors

3005
W 115 x 38 mm ROOF TRUSS ON 115 x 38 mm WALL and windows, fixtures and electrical layout

2500
1700
STEP PLATES * Roof notes and schematic diagram of a roof truss
1900

GROUND LINE
* The incomplete foundation/footing, slab and wall detail of the three

200
PLASTER CEILING BOARD ON 38 x 38 mm
FEATURES: BRANDERING STRIPS @ 700 mm c/c walls to be used in the contruction of the new public toilets
D DOOR * A door and window schedule
100 x 100 mm GUTTER ON ALL SIDES
INCOMPLETE WEST ELEVATION W1 WINDOW * A table of roof componets
W2 WINDOW 900
G c/c * A table of wooden window frame profile
n x 40W 900
DOOR FRAME AND DOOR FOR TOILETS c/c * A table of fixtures
RWDP FIXTURES: 900
c/c
1000 500
WC TOILET * A table of electrical symbols
6 WB WASH-BASIN
D WC W2 * A table of rainwater items
U URINAL
SCHEMATIC DIAGRAM * The incomplete floor plan of the new public toilets, drawn to
OPEN OUT A OF A ROOF TRUSS
4 ELECTRICAL FITTINGS: scale 1 : 50 on page 41
900

HINGED 3 D WC 1. LIGHT SWITCH THREE-POLE


1 WB
OPEN IN 2. LIGHT SWITCH DOUBLE-POLE
A 3. FLUORESCENT LIGHT 3 x 40W Instructions:
4. CEILING LIGHT Answer this question on page 41.
D WC W2 5. WALL MOUNTED LIGHT Use the given incomplete floor plan, draw, in first-angle orthographic
5
WINDOW (W1) WINDOW (W2) 6. SWITCHED SOCKET OUTLET
RAINWATER B projection and to scale 1 : 50, the following views of the new public
ITEMS
D WC NOTE: toilets:
NOTES: THE ARROW SHOWS THE LIGHT 1. THE COMPLETE FLOOR PLAN
150 x 20 FIBRE CEMENT SILL UNDER ALL 2 WB
100 3 A CONNECTION TO THE SWITCH.
WINDOWS U U Add the following features to the drawing:
100

4
W2
* ALL the doors and windows
ROOF COMPONENTS GUTTER
* ALL fixtures as indicated by abbreviations
6
200 350
* The electrical layout as indicated by numbers
W1
ROOF CAP RWDP * ALL hatching detail.
ROOF LINE
18° G 2. THE WEST ELEVATION
115 x 38 WALL PLATE INCOMPLETE FLOOR PLAN Show the following features on the drawing:
Ø76 * The outside walls and window detail
75 x 50 PURLINS * The roof detail including the fascia board, gutter, rainwater
2600

222
110 down pipe and gully
WINDOW FRAME PROFILE * The finished floor level
3. Draw, to scale 1 : 20, a DETAILED SECTION on cutting plane
20 20 110 A-A of the area in the ellipse shown on the floor plan on page 41.
Show the following features on the drawing:
RWDP * The complete foundation and external wall detail
* The complete footing and wall A detail
40

30

* The roof detail


150
400
20
10

* The window detail with a double lintel

2500

2500
400
50 * ALL features to the east of the cutting plane A-A
1900

GULLEY (G) * ALL hatching detail. ONLY the substructure hatching may be
drawn in freehand.
FIXTURES
500 Label the following:
30° 30° 30° 30°
* The west elevation
300

100
* The room designation and floor finish (tiles)
500

GROUND * Using correct abbreviations, label the following features in the

550
200 200
900

900

850

LINE

300 250
400 400
correct views: ground level, finished floor level and damp proof-
400

course.
FLOOR LEVEL
700
NOTE:
250

WALL A
400

460

INCOMPLETE FOOTING, SLAB AND ALL drawings must comply with the guidelines and graphic
700

WALL B
WALL DETAIL OF THE INTERNAL
INCOMPLETE FOOTING, SLAB AND
INCOMPLETE FOUNDATION, SLAB symbols contained in the SANS 10143.
400 600 WALLS BETWEEN THE TOILET AND EXTERNAL WALL DETAIL
INTERNAL WALL DETAIL
CUBICLES AND THE URINALS
URINAL (U) WASH-BASIN (WB) TOILET (WC)

COPYRIGHT © JP
KOPIEREG © JP
NAME: CIVIL DRAWING
GRADE 12:
ENGINEERING GRAPHICS & DESIGN DATE:
DEUR- & VENSTERSKEDULE VRAAG: SIVIELE TEKENING
ELEKTRIESE DAKNOTAS:
OM TE PAS SIMBOLE DAKHELLING 15° MET 200 x 20 mm FASSIEPLANK
AAN ALLE KANTE Gegee:
* Die onvolledige wesaansig van nuwe publieke toilette, wat die
DAKBEDEKKING 15 mm VESELSEMENTPLAAT OP
75 x 50 mm KAPLATTE @ 900 mm s/s
mure, die dak en notas toon
FASSIEPLANK
VENSTEROPENING * Die onvolledige vloerplan wat die mure, posisie van die deure en

3005
W 115 x 38 mm DAKKAP OP 115 x 38 mm MUURPLATE vensters, toebehore en elektriese uitleg toon

2500
1700
TRAP * Daknotas en 'n skematiese diagram van 'n dakkap
1900

GRONDLYN GIDSPLAFONBORD OP 38 x 38 mm PLAFONLATTE


* Die onvolledige fondasie-/voet-, vloerblad- en muurbesonderhede

200
@ 700 mm s/s
KENMERKE: van die drie mure wat in die konstruksie van die nuwe publieke
D DEUR 100 x 100 mm GEUT OP ALLE KANTE toilette gebruik moet word.
ONVOLLEDIGE WESAANSIG V1 VENSTER * 'n Deur- en vensterskedule
V2 VENSTER 900
R s/s * 'n Tabel van dakkomponente
n x 40W 900
DEURRAAM EN DEUR VIR TOILETTE s/s * 'n Tabel van die houtraamvensterprofiel
RWAP TOEBEHORE: 900
s/s
1000 500
SK TOILET * 'n Tabel van toebehore
6 WB WASBAK
D SK V2 * 'n Tabel van elektriese simbole
U URINAAL
SKEMATIESE DIAGRAM * 'n Tabel van reënwateritems
OPEN UIT A VAN 'N DAKKAP
4 ELEKTRIESE TOEBEHORE: * Die onvolledige vloerplan van die nuwe publieke toilette, geteken
900

SKARNIER 3 D SK 1. LIGSKAKELAAR - DRIEPOOL volgens skaal 1 : 50, op bladsy 41


1 WB
OPEN IN 2. LIGSKAKELAAR - TWEEPOOL
A 3. FLUORESSEERLIG 3 x 40 W
4. PLAFONLIG Instruksie:
D SK V2 5. MUURGEMONTEERDE LIG Beantwoord die vraag op bladsy 41.
5
VENSTER (V1) VENSTER (V2) 6. SKAKELAARKRAGPUNT
REËNWATER- B Gebruik die gegewe onvolledige vloerplan en teken, volgens
ITEMS
D SK LET WEL: skaal 1 : 50 en in eerstehoekse ortografiese projeksie, die volgende
LET WEL: DIE PYL TOON DIE LIGVERBINDING aansigte van die nuwe publieke toilette:
150 x 20 VESELSEMENTVENSTERBANK 2 WB
100 3 A MET DIE SKAKELAAR AAN.
ONDER ALLE VENSTERS U U 1. DIE VOLLEDIGE VLOERPLAN
100

4
V2
Voeg die volgende kenmerke by die tekening:
DAKKOMPONENTE GEUT
* ALLE deure en vensters
6
200 350
* ALLE toebehore soos deur die afkortings aangedui
V1
DAKNOK RWAP * ALLE elektriese toebehore soos deur die nommers aangedui
DAKLYN
18° R * ALLE arseringsbesonderhede.
115 x 38 MUURPLAAT ONVOLLEDIGE VLOERPLAN 2. DIE WESAANSIG
Ø76 Toon die volgende kenmerke op die tekening:
75 x 50 KAPLATTE * Die buitemure en vensterbesonderhede
2600

222
110 * Die dakbesonderhede, wat die fassieplank, geute, reënwater-
VENSTERRAAMPROFIEL afvoerpyp en rioolput insluit
* Die onvoltooide vloervlak
20 20 110
3. Teken, volgens skaal 1 : 20, 'n GEDETAILLEERDE SNIT
RWAP volgens snyvlak A-A van die area in die ellips wat op die vloer-
plan op bladsy 41 getoon word.
40

30

Toon die volgende kenmerke op die tekening:


150
400
20
10

* Die volledige fondasie- en buitemuurbesonderhede

2500

2500
400
50 * Die volledige voet- en muur A-besonderhede
1900

RIOOLPUT (R) * Die dakbesonderhede


* Die vensterbesonderhede met 'n dubbele latei
TOEBEHORE * ALLE kenmerk aan die oostekant van snyvlak A-A
500 * ALLE arseringsbesonderhede. SLEGS die substruktuurarsering
30° 30° 30° 30°
mag in vryhand geteken word.
300

100
500

Benoem die volgende:

550
200 200
900

900

850

GRONDLYN

300 250
400 400
* Die wesaansig
400

* Die kameraanduidings en vloerafwerking (teëls)


VLOERVLAK
* Gebruik die korrekte afkortings en benoem die volgende kenmerke
700
op die korrekte aansig: grondvlak, voltooide vloervlak en vogweer-
250
400

460

MUUR A laag.
700

ONVOLLEDIGE VOET-, VLOERBLAD- MUUR B ONVOLLEDIGE FONDASIE-,


EN MUURBESONDERHEDE VAN DIE ONVOLLEDIGE VOET-, VLOERBLAD- VLOERBLAD- EN BUITEMUUR-
400 600 BINNEMURE TUSSEN DIE EN BINNEMUURBESONDERHEDE BESONDERHEDE LET WEL:
TOILETHOKKIES EN DIE URINAAL ALLE tekene moet aan die riglyne en grafiese simbole vervat in
URINAAL (U) WASBAK (WB) TOILET (SK)
die SANS 10143.

COPYRIGHT © JP
KOPIEREG © JP
NAAM: SIVIELE TEKENING
GRAAD 12:
INGENIEURSGRAFIKA & ONTWERP DATUM:
G

RWDP

A A

RWDP
ROOF LINE
G PLAN DETAILED SECTION Use marking rubric p 46 of the CAPS
SCALE 1 :50 SCALE 1 : 20 for multi-view civil working drawings.

COPYRIGHT © JP
KOPIEREG © JP
NAME: CIVIL DRAWING
GRADE 12:
ENGINEERING GRAPHICS & DESIGN DATE:
R

RWAP

A A

RWAP
DAKLYN
R PLAN GEDETAILLEERDE SNIT Gebruik merkrubriek bl 44 van die KABV
SKAAL 1 :50 SKAAL 1 : 20 vir multi-aansig siviele werkstekeninge.

COPYRIGHT © JP
KOPIEREG © JP
NAAM: SIVIELE TEKENING
GRAAD 12:
INGENIEURSGRAFIKA & ONTWERP DATUM:

You might also like