CORRECT SOLUTION CONTAINER - INITIAL INSERTION OF A - READ LABEL OF THE NEW CATHETER WIT TRANSPARENT CONTINER DRESSING OR SERIL GAUZE - VERIFY CORRECT SOLUTION - LABELED: TIME AND DATE - CORRECT CLIENT PURPOSE: - CORRECT ADDITIVES - CORRECT DOSE - MAINTAIN REQUIRED FLUID FLOW SET UP: - STERILITY OF IV SYSTEM - TIME - DECREASE INCIDENCE OF - PRIME THE TUBE PLEBITIS AND INFECTION - LABEL THE TUBE - MAINTAIN PATENCY OF IV TUBING STRIP TAPES: - PREVENT INFECTION AT THE IV SITE AND INTRODUCTION - BUTTERFLY NEEDLE: 2-3 OF MICROORGANISMS INTO 1.25CM(1/2IN) TAPES THE BLOOD STREAM - CATHETER: 3 STRIPS 1.25CM - HANG THE TAPES AT THE ASSESSMENT: EDGE OF THE TABLE: READINESS (ENSURE TABLE IS - PRESENCE OF FLUID CLEAN FOR AVOID INFILTRATION CONTAMINATING THE TAPE) - BLEEDING - PHLEBITIS OPEN ALL EQUIPMENTS: - IV SITE - ALLERGY TO TAPE OR IODINE - DRESSING - INFUSION RATE AND AMOUNT - SWABS ABSORBED - ADHESIVE BANGAE - BLOCKAGE IN IV SYSTEM - OINTMENT - APPEARANCE OF DRESSING PLACE TOWEL UNDER THE o INTEGRITY EXTREMITY: o MOISTURE - PREVENT SOILING OF BED o NEED FOR CHANGE LINEN - TIME AND DATE PREVIOUS DRESSING CHANGE REMOVE TAPE ONE LAYER AT A TIME: PLANNING: - PREVENT DISLODGEMENT - REVIEW CARE PROVIDER’S ORDER FOR CHANGES IN REMOVE ADHESIVE IN THE FLUID AD. DIRECTION OF THE CLIENT’S HAIR: - MINIMIZE DISCOMFORT ASSESS IV SITE: (AVOID FURTHER LABEL THE DRESSING AND SECURE TRAUMA) IV TUBING: - PRESENCE OF INFILTRATION - DATE AND TIME - INFLAMMATION - SECURE IV TUBING WITH ADDITIONAL TAPE (AS CLAMP THE TUBE: (PREVENT REQUIRED) BLOOD FROM COMING OUT OF THE NEEDLE) DOCUMENT: - WITH NON-DOMINANT HAND - SOLUTION CONTAINER - APPLY PRESSURE TO THE VEIN - TUBING ABOVE THE END OF THE - DRESSING CATHETER - FLUID INTAKE - NUMBER OF CONTAINER HOLD THE HUB: - ASSESSMENT - THUMB AND INDEX FINGER OF EVALUATION: NON-DOMINANT HAND - STATUS OF IV SITE LOOSEN THE TUBING: - PATENCY OF IV SYSTEM - DOMINANT HAND - ACCURACY OF FLOW - USING TWISTING PULLING CONSIDERATIONS: MOTION - ASSEBLE MATERIALS PRIOR USING CHLORHEXIDINE SWABS: THE PROCEDURE (PREVENT CONTAMINATION OF IV - WASH HANDS BEFORE AND SITE FROM BACTERIA) AFTER - CLEAN THE SITE - EXPLAINE THE PROCEDURE - BEGINNING AT THE CATHETER - VEIN ARE DIFFICULT TO AND CLEANING OUTWARD 2- ACCESS: INCHES DIAMETER o WARM SOAKS – TO INCREASE BLOOD FLOW RETAIN THE NEEDLE OR - NON/LATEX GLOVES ARE CATHETER: WORN FOR INSERTION OF THE - BUTTERFLY NEEDLE CATHETER AND CHANGING o TAPE TO THE WINGS THE DRESSING o CRISS CROSS - SITE OR DRESSING SHOULD BE o CHEVRON METHOD MARKED WITH LABELS - CATHETER o DATE o APPLY TAPE USING U o TIME METHOD o INITIALS OF THE INDV. PERFORMING THE PROCEDURE.