You are on page 1of 2

CHANGING AN IV CONTAINER PROCEDURES:

TUBING AND DRESSING


CORRECT SOLUTION CONTAINER
- INITIAL INSERTION OF A
- READ LABEL OF THE NEW
CATHETER WIT TRANSPARENT
CONTINER
DRESSING OR SERIL GAUZE
- VERIFY CORRECT SOLUTION
- LABELED: TIME AND DATE
- CORRECT CLIENT
PURPOSE: - CORRECT ADDITIVES
- CORRECT DOSE
- MAINTAIN REQUIRED FLUID
FLOW SET UP:
- STERILITY OF IV SYSTEM
- TIME
- DECREASE INCIDENCE OF
- PRIME THE TUBE
PLEBITIS AND INFECTION
- LABEL THE TUBE
- MAINTAIN PATENCY OF IV
TUBING STRIP TAPES:
- PREVENT INFECTION AT THE
IV SITE AND INTRODUCTION - BUTTERFLY NEEDLE: 2-3
OF MICROORGANISMS INTO 1.25CM(1/2IN) TAPES
THE BLOOD STREAM - CATHETER: 3 STRIPS 1.25CM
- HANG THE TAPES AT THE
ASSESSMENT: EDGE OF THE TABLE:
READINESS (ENSURE TABLE IS
- PRESENCE OF FLUID
CLEAN FOR AVOID
INFILTRATION
CONTAMINATING THE TAPE)
- BLEEDING
- PHLEBITIS OPEN ALL EQUIPMENTS:
- IV SITE
- ALLERGY TO TAPE OR IODINE - DRESSING
- INFUSION RATE AND AMOUNT - SWABS
ABSORBED - ADHESIVE BANGAE
- BLOCKAGE IN IV SYSTEM - OINTMENT
- APPEARANCE OF DRESSING PLACE TOWEL UNDER THE
o INTEGRITY EXTREMITY:
o MOISTURE
- PREVENT SOILING OF BED
o NEED FOR CHANGE
LINEN
- TIME AND DATE PREVIOUS
DRESSING CHANGE REMOVE TAPE ONE LAYER AT A
TIME:
PLANNING:
- PREVENT DISLODGEMENT
- REVIEW CARE PROVIDER’S
ORDER FOR CHANGES IN REMOVE ADHESIVE IN THE
FLUID AD. DIRECTION OF THE CLIENT’S HAIR:
- MINIMIZE DISCOMFORT
ASSESS IV SITE: (AVOID FURTHER LABEL THE DRESSING AND SECURE
TRAUMA) IV TUBING:
- PRESENCE OF INFILTRATION - DATE AND TIME
- INFLAMMATION - SECURE IV TUBING WITH
ADDITIONAL TAPE (AS
CLAMP THE TUBE: (PREVENT
REQUIRED)
BLOOD FROM COMING OUT OF THE
NEEDLE) DOCUMENT:
- WITH NON-DOMINANT HAND - SOLUTION CONTAINER
- APPLY PRESSURE TO THE VEIN - TUBING
ABOVE THE END OF THE - DRESSING
CATHETER - FLUID INTAKE
- NUMBER OF CONTAINER
HOLD THE HUB:
- ASSESSMENT
- THUMB AND INDEX FINGER OF
EVALUATION:
NON-DOMINANT HAND
- STATUS OF IV SITE
LOOSEN THE TUBING:
- PATENCY OF IV SYSTEM
- DOMINANT HAND - ACCURACY OF FLOW
- USING TWISTING PULLING
CONSIDERATIONS:
MOTION
- ASSEBLE MATERIALS PRIOR
USING CHLORHEXIDINE SWABS:
THE PROCEDURE
(PREVENT CONTAMINATION OF IV
- WASH HANDS BEFORE AND
SITE FROM BACTERIA)
AFTER
- CLEAN THE SITE - EXPLAINE THE PROCEDURE
- BEGINNING AT THE CATHETER - VEIN ARE DIFFICULT TO
AND CLEANING OUTWARD 2- ACCESS:
INCHES DIAMETER o WARM SOAKS – TO
INCREASE BLOOD FLOW
RETAIN THE NEEDLE OR
- NON/LATEX GLOVES ARE
CATHETER:
WORN FOR INSERTION OF THE
- BUTTERFLY NEEDLE CATHETER AND CHANGING
o TAPE TO THE WINGS THE DRESSING
o CRISS CROSS - SITE OR DRESSING SHOULD BE
o CHEVRON METHOD MARKED WITH LABELS
- CATHETER o DATE
o APPLY TAPE USING U o TIME
METHOD o INITIALS OF THE INDV.
PERFORMING THE
PROCEDURE.

You might also like