You are on page 1of 6

This document is the property of Larsen & Toubro Limited, ECC Division - EDRC and must not be passed

on to any third person or firm not authorised by us, nor be copied/made use of in full or

22.09.05 0 For Approval NRD KBR NRKR


DATE REV. NO. DESCRIPTION Designed Checked Approved
part by such person or firm without our prior permission writing

REVISIONS

LARSEN & TOUBRO LIMITED


ECC Division - EDRC

CLIENT :

Government of Andhra Pradesh


Irrigation & C.A.D (P.W) Department

PROJECT : ALISAGAR LIFT IRRIGATION SCHEME, NIZAMABAD, AP

LARSEN & TOUBRO LIMITED


SUPPLIER / CONTRACTOR:
ECC Division - EDRC

JOB No. O5037-S-HS


TOTAL NO. OF PAGES TITLE :
NAME SIGN DATE
DSGN NRD NRD 20.09.05 ALISAGAR LIFT IRRIGATION SCHEME
STAGE - III -PUMP HOUSE - DESIGN OF SUPERSTRUCTURE
CHKD KBR KBR 22.09.05
(PART 1 OF 3)
APPD NRKR NRKR 22.09.05
CODE REV.
DOC. No. O 5 0 3 7 - S - H S - H D - D C - 0 0 4 5
IS 0

RELEASED FOR PRELIMINARY TENDER INFORMATION P APPROVAL CONSTRUCTION


LARSEN & TOUBRO LIMITED
ECC Division - EDRC

PROJECT: DOCUMENT NO. DATE

TITLE: DESIGNED CHECKED SHEET


Design of Isolated footing NMC

Datas and Assumptions

Size of column = 300 mm x 300 mm

Axial Load on Footing F = 711.00 kN

Moment from the column(in X) Mx = 25.50 kN.m

Moment from the column(in Z) Mz = 15.20 kN.m

Factor of Safety = 1.5

Safe bearing Capacity of Soil at 1.50m from FGL = 150 kN/m2

Characteristic Strength of Concrete = 20 N/mm2

Characteristic Strength of Steel = 415 N/mm2

Clear cover to concrete d' = 50 mm

Diameter of bar = 12 mm

Calculation of Size of footing

Assuming Self weight of footing = 10%(load on footing) = 71.100 KN

Total load on footing = 71.1+711 = 782.100 KN

Area of footing = 782.1 / 150 = 5.214 mm2

Size of footing = SQRT(5.214) = 2.283 mm

Provide a footing of size 2.50m x 2.50m

Check for sresses

Pressure on footing = (P/A + Mx/Z + Mz/Z)

= 782.1 / 2.5x2.5 + 25.5x6 / 2.5x2.5^2 + 15.2x6 / 2.5^2 x2.5

P1 = 140.7648 kN/m2 > SBC, Hence Safe

P2 = 129.0912 kN/m2

P3 = 121.1808 kN/m2

P4 = 109.5072 kN/m2 Safe

Calculation of Gross SBC

Axial Load from Column, including column self weight = 711.00 kN


LARSEN & TOUBRO LIMITED
ECC Division - EDRC

PROJECT: DOCUMENT NO. DATE

TITLE: DESIGNED CHECKED SHEET


Design of Isolated footing NMC

Self weight of footing = 46.88 kN

Self weight of soil fill = 118.80 kN

Total vertical Load on the footing Pg = 876.68 kN

Stresses on footing = (Pg/A + Mx/Z + Mz/Z)

P1 = 155.897 kN/m2

P2 = 144.223 kN/m2

P3 = 136.313 kN/m2

P4 = 124.639 kN/m2

Gross SBC (Net SBC + g D) = 150+ 18 x (1.5 - 0.3) = 171.600 kN/m2

Check for one way shear

For one way shear , the critical section is at a distance 'd' from the face of the column

Initially Assuming D = 500 mm

Effective Depth d = 444 mm

Distance of Critical section from the edge of footing = 656 mm

Critical shear area 2.50m x 0.66m

1100

Z
2.50m

d
2.50
X

109.507
LARSEN & TOUBRO LIMITED
ECC Division - EDRC

PROJECT: DOCUMENT NO. DATE

TITLE: DESIGNED CHECKED SHEET


Design of Isolated footing NMC
140.765
LARSEN & TOUBRO LIMITED
ECC Division - EDRC

PROJECT: DOCUMENT NO. DATE

TITLE: DESIGNED CHECKED SHEET


Design of Isolated footing NMC

Pressure at Critical Section 2.50 31.258


=
1.844 x

x = 23.056 KN/m2

Pressure at critical section = 132.563 KN/m2

Vu1 = 132.56x2.5x1100x10^-3 = 364.55 kN

Shear Stress = 364.55 x1000 /444x2.5x1000 = 0.328 N/mm2

Assuming
IS456:2000
-Table 19 Design shear strength tc for pt = 0.25 and M20 Concrete = 0.36 N/mm2

Safe in Oneway Shear

Check for Two way Shear

The critical section is located at a distance d/2 from the face of the column all around

Punching Shear area = 1321344 Sq.mm

Vertical Load from Column = 782.10 kN

Punching Shear Sterss = 0.592 N/mm2

Limiting shear stress = Ksx0.25(fck)0.5

Ks = 0.5 + bc = 0.5 +(Shorter dim of column / Longer Dim of column) < 1 = 1.500 >1

Hence Ks = 1.00

Hence limiting Shear stress tc,lim 1x0.25xSQRT(20) = 1.118 Mpa

tp < tc,lim Hence safe against punching shear

Check for effective depth

Mu = 0.138fckbd2

d,req = 74mm

Anyway provide minimum thickness D = 500mm

d = 444mm
LARSEN & TOUBRO LIMITED
ECC Division - EDRC

PROJECT: DOCUMENT NO. DATE

TITLE: DESIGNED CHECKED SHEET


Design of Isolated footing NMC

Calculation of reinforcement

At bottom, Mu/bd2 = 0.052

Pt = 0.120

Ast = 1332 Sq.mm

Provide 12 mm dia bars at 200 mm c/c at bottom both ways

Min Pt = 0.12

Min Ast = 1332 Sq.mm

Provide 12 mm dia bars at 200 mm c/c at top both ways