Specification
Model Name Unit ATUW30GPLT1 ABUW30GM1T1 AVUW30GM1T1
Power Supply V , Ø , Hz 220 - 240,1,50 220 - 240,1,50 220 - 240,1,50
Cooling Rated A 10.5 10.5 10.5
Running Current
Heating Rated A 10.1 11.1 10.1
Power Factor Rated - 0.99 0.99 0.99
Power Supply Cable (included Earth) No. × mm² 3C × 2.5 3C × 2.5 3C × 2.5
Casing Color - Warm Gray Warm Gray Warm Gray
Net W×H×D mm 950 x 834 x 330 950 x 834 x 330 950 x 834 x 330
Dimensions
Shipping W×H×D mm 1 065 x 918 x 461 1 065 x 918 x 461 1 065 x 918 x 461
Net kg 60.8 60.8 60.8
Weight
Shipping kg 67.9 67.9 67.9
Type - Twin Rotary Twin Rotary Twin Rotary
Model Model × No. GJT325MAA x 1 GJT325MAA x 1 GJT325MAA x 1
Compressor
Motor type - BLDC BLDC BLDC
Motor Output W × No. 2 137 × 1 2 137 × 1 2 137 × 1
Type - R410A R410A R410A
GWP (Global Warming Potential) - - - -
Precharged Amount g 2 200 2 200 2 200
Refrigerant t-CO₂eq. - - - -
Control - Electronic Expansion Valve
Chargeless-Pipe Length m 7.5 7.5 7.5
Additional Charging Volume g/m 40 40 40
Type - FVC68D FVC68D FVC68D
Refrigerant Oil
Charged volume cc × No. 950 × 1 950 × 1 950 × 1
Heat Exchanger (Row × Column × FPI) × No. - (2 × 38 × 14) × 1 (2 × 38 × 14) × 1 (2 × 38 × 14) × 1
Type - Axial Axial Axial
Fan
Air Flow Rate Rated m³/min × No. 60 × 1 60 × 1 60 × 1
Type BLDC BLDC BLDC
Fan Motor
Output W × No. 124 × 1 124 × 1 124 × 1
Cooling Rated dB(A) 51 51 51
Sound Pressure Level
Heating Rated dB(A) 53 53 53
Cooling Rated dB(A) - - -
Sound Power Level
Heating Rated dB(A) - - -
Liquid Outer Dia. mm (inch) Ø 9.52(3/8) Ø 9.52(3/8) Ø 9.52(3/8)
Piping Connections
Gas Outer Dia. mm (inch) Ø 15.88 (5/8) Ø 15.88 (5/8) Ø 15.88 (5/8)
Rated m 5 5 5
Piping Length
Max. m 50 50 50
Maximum Height Difference (ODU ~ IDU) Max. m 30 30 30

Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) WB
Outdoor 35°C(95°F) DB / 24°C(75.2°F) WB
- Heating Temperature : Indoor 20°C(68°F) DB / 15°C(59°F) WB
Outdoor 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Piping Length : Interconnected Pipe Length = 5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national code.
3. Due to our policy of innovation some specifications may be changed without notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during operation.

-2- Copyright © 2022 LG Electronics Inc.