Professional Documents
Culture Documents
Cross-Checked
Department Name Date Visa
Owner :
Id N°: TLG/00/B/Z0306.0029/DC/---
REVISION DESCRIPTION
The information contained herein is GE proprietary information and has been disclosed in confidence to the designated
party for specified purposes only. Any use, disclosure or reproduction contrary thereto is a violation of GE’s right. ©GE
2015. All rights reserved.
Rev : A
THANG LONG 2 x 300MW
METAL TEMPERATURE LOCATION Page : 3/6
Id N°: TLG/00/B/Z0306.0029/DC/---
TABLE OF CONTENT
1 PURPOSE ________________________________________________________________________________ 4
The information contained herein is GE proprietary information and has been disclosed in confidence to the designated
party for specified purposes only. Any use, disclosure or reproduction contrary thereto is a violation of GE’s right. ©GE
2015. All rights reserved.
Rev : A
THANG LONG 2 x 300MW
METAL TEMPERATURE LOCATION Page : 4/6
Id N°: TLG/00/B/Z0306.0029/DC/---
1 PURPOSE
The purpose of this process note is to define the metal temperature locations for the CFB Boiler 2 x 300
MWe of Thang Long in Viet Nam. As for Baima, metal temperature probes are installed on:
furnace right wall and roof
boiler rear pass rear wall, window tubes and roof
boiler rear pass hanger tubes
Boiler LEFT
axis
41600mm
Furnace 200mm
+/-200
axis
36730mm
Outlet
window
Window top level
+/-200mm
+/-200
Outlet window
FRONT REAR
EL +35700mm
-0/+500mm Legend
on fin
on tube
1200mm 1200mm
+/-200
RIGHT +/-200
The information contained herein is GE proprietary information and has been disclosed in confidence to the designated
party for specified purposes only. Any use, disclosure or reproduction contrary thereto is a violation of GE’s right. ©GE
2015. All rights reserved.
Rev : A
THANG LONG 2 x 300MW
METAL TEMPERATURE LOCATION Page : 5/6
Id N°: TLG/00/B/Z0306.0029/DC/---
FRONT
Boiler
axis
52849mm
50674mm
Backpass axis
+/-200mm
RIGHT LEFT
1200mm 1200mm
+/-200 +/-200
Legend
REAR
on fin
on tube
The information contained herein is GE proprietary information and has been disclosed in confidence to the designated
party for specified purposes only. Any use, disclosure or reproduction contrary thereto is a violation of GE’s right. ©GE
2015. All rights reserved.
Rev : A
THANG LONG 2 x 300MW
METAL TEMPERATURE LOCATION Page : 6/6
Id N°: TLG/00/B/Z0306.0029/DC/---
FRONT
Hanger tubes
1500mm+/-200
1200mm
+/-200
1500mm+/-200
Backpass axis
1200mm 1200mm
+/-200 +/-200
RIGHT LEFT
1200mm
+/-200
Backpass Backpass
axis REAR axis
Protection
Flue gas sheet
flow to rear
pass
The information contained herein is GE proprietary information and has been disclosed in confidence to the designated
party for specified purposes only. Any use, disclosure or reproduction contrary thereto is a violation of GE’s right. ©GE
2015. All rights reserved.