DC cable testing up to 40kV-50mA . 80kV System is Display 21 inch Touch-sensitive.

also available on request. Easy user friendly interface.

Cable Burning 40kV /200 mA High safety level

Surge Voltage 4, 8, 16 & 32kV Multistep self fault protection.

Surge Energy up to 2000Joules. Flexible auxiliary equipment integration.

Surge ranges/timer/Hipot voltage/ Burn voltage & current Cable Drums - 30mtr (other lengths are also

setting controlled by Touch Screen as well as serial mouse. available on request)

Pre-location mode TDR, ICM, SIM & Decay. Help menu available in system

Pre-location range up to 120km. Customisation available as per requirement


Features
Perfect functions, suitable for pin-pointing all kinds of cable
faults and detect cable path.
Synchronous sensing of acoustic and magnetic signals of the
fault with high ability to anti-interference.
Waveforms displayed on large LCD
With the assistance of the earphone, direct and easy to
identify the fault.
High Performance electronic suppression of external noise
and interference
Automatic contactless turn off of the Headset, as the hand
approaches the handle
Indication of the direction to the fault compass
Low batt indication.
Indication of the acoustic signal detection
Fault distances measurement
Measure of magnetic field and sound coincidence with
acoustic selection and calibration of the measuring range.
Indication of cable position in respect to the sensor.
Cursor to identify the time of delay between the acoustic
Automatic switch between different work modes
SLE 200-Z
Surge Wave Receiver

Surge Wave Receiver SLE200-Z is a highly sensitive equipment to Applications


exactly locate the fault point in a short time. It can be used on low, The SLE 200-Z Surge Wave Receiver is an easy operation
medium, and high voltage power networks effectively. device used to pinpoint the fault point. It integrated the
The success of locating the exact fault point on the underground function of acoustic magnetic synchronization method, the
cable depends on the search carried out on the lay of the cable. This step voltage method, the magnetic field strength method to
calls for an indication to guide the operator to walk precisely on the make the pinpointing accuracy.
cable route.

Working Principle
Function
Surges of high voltage are passing into the faulty cable
The surge wave receiver is a sensitive amplifier circuit: It has two
through a suitable surge tester; a magnetic field is developed
separate channels magnetic and acoustic. The acoustic channel is a
around the cable. When the ground microphone is kept
wideband pass filter and the magnetic is a high frequency active filter.
perpendicular to the ground surface of the underground
The main function of the receiver is to amplify the signal which is cable, the magnetic channel will start to indicate the presence
received from the ground microphone and displayed on LCD display. of a magnetic signal and show on LCD bar graph and
To adjust the level of amplification separate level control for magnetic depending on the soil and fault condition, the noise and
vibrations are received by it from a certain distance and the
and volume control for acoustic channels is provided on the front
acoustic channel starts showing its presence.
panel.
When reached at the fault point the acoustic bar-graph
display is at its maximum level, hence achieving the pin-
pointing of cable fault in the shortest possible time.
Technical Details SLE 200-Z

Specifications
Acoustic Magnetic Synchronous Pin-pointing Acoustic channel

Bandwidth All- pass 80Hz - 1500Hz

Low- pass 80Hz - 400Hz

High- pass 200Hz - 1500Hz

Band- pass 150Hz - 600Hz

Signal Gain > 100db

Accuracy 0.1m

Step Voltage Function (Optional) Magnification time >80db

Gain Adjustment Manual

Indication of direction to
Yes
the fault Compass

Indication of Acoustic Signal Detection Yes

Powe Supply Battery Built-in Li-ion battery 7.4V- 3400mAh

Working Time 9 hours approx

Charger Input AC220V + 10%, 50Hz | Output 8.4V, DC 1A

Quick Charging Below 4 hours

Display Method 320 x 240 dot LCD Screen

IP Protection Sensor - IP 54, Receiver - IP 65

Dimensions 210mm x 95mm x 115mm

Weight 0.6 Kg

Standard Accessories
Ground Sensor

Headphone

Carrying Stick - Connect to Sensor

Connecting Cables

Carrying Case

Instruction Manual

Note : Picture is for illustration purposes only.


Features
Route tracing of buried underground any metallic cables up
to 15 km max length.
LCD Bar-graph on Audio frequency receiver unit for
precise indication of cable route tracing.
Route tracing of underground loaded live cables with
passive frequency and inductive coupling.
Depth measurement of buried cables up to 5 m with
triangulation method.
Peak and null reception methods for route tracing of cables.
Pin-pointing of contact nature faults.

CRT 10D
Cable Route Tracer

Cable Route Tracer CRT 10D is an essential item in the kit for fault
location of underground power and telecom cable network. It is a Applications
powerful audio frequency system that can be effectively used for
It is used for route tracing of any underground metallic cable in
various unique functions such as route tracing of any metallic cable,
power transmission, distribution and signal cable networks or
depth measurement, live loaded cable tracing and ground survey of
cable fault location service provider.
underground utilities.

The system is capable to trace route of underground cable maximum


10km, and find out the depth up to 5 meter, This method is found to
give more accurate results in presence of other metallic utilities in
close proximity.
Working Principle
The Audio Frequency Generator injects an Audio frequency
The system can be used to trace route of loaded live cable with the signal into the cable which generates an electromagnetic field
help of receiver unit and search coil in passive mode. It is also use to around it.
carry out ground survey and metallic pipe route tracing in inductive
mode effectively. This field is concentric to the cable & is present over the entire
length. The presence of this field is detected by a highly
selective and sensitive receiver with a search coil.

Function
The audio frequency signal passes through the cable conductor an
electromagnetic field of sending frequency is developed around on
the conductor. When the search coil axis is passing in the developed
field, it will sense the field and give it to the receiver unit.

The receiver amplifies that signal and indicates in terms of maximum


signal strength and sound in the buzzer on the cable. When the search
coil is going away from the field the signal indication and sound will
reduce.
Technical Details CRT 10D

Working Mode Surge & DC Test


Audio Frequency Generator AFG 10
Output Power 1, 2, 5 and 10 Watts selectable

Output Frequency 480Hz, 1450Hz & 9820Hz selectable

Impedance Matching From 0.5 to 1000 Ohms selectable

Indication Analog meter indication to indicate of transmitted power and matching ON Indication

Power Supply 230V AC +10%, 50 Hz Single phase or external 12 Volt DC of Internal rechargeable accumulator

Operating Time Internal accumulator 1.5 Hrs on 10 Watts Mains and Ext. DC Power supply no time limit.

Storage Temp. -50C - 600C

Working Temp. 00C - 550C

Dimensions 270 mm (L) x 248 mm(H) x 175 mm (D)

Weight 5.45 Kg Approx

Audio Frequency Receiver AFRD 10

Receiving Frequency Receiving three kinds of sinusoidal AC signals of different frequencies, namely low frequency, intermediate

frequency, high frequency, 50HZ/60Hz.

Receiving Mode Crest method (horizontal coil), trough method (vertical coil), external device method (A-frame, coupling clamp).

Signal interface Three interfaces of digital size, grating length, and voice prompt simultaneously indicate the strength of the signal

Display interface Large-screen, graphic display, with backlight

Gain Control Manual adjustment, dynamic range 000-100db.

Detection length When directly connected to the cable, the maximum length 10 km.

When coupling cables, one coupling can measure 3Km, and multiple couplings are infinite. When the cable

is inducted, it can measure 300m in one induction and infinitely in many times.

Depth Measurement Direct reading detection depth, range 000-250cm. 80% method for measuring depth, range 000-250cm (induction)

Current Measurement Direct reading current

Detection Accuracy 5% of buried depth

Power Source Standard No. 5 1.2V rechargeable battery 6, charge and discharge 500 time

Stand by Time more than 12hours, power prompt.

Over heating & Over Current Automatic Protection.

Working Temperature 00C - 500C

Dimensions 690 x 110 x 230 mm

Weight 1.8 kg approx

Standard Accessories
Transmitter Tongs CTS120 Connecting Cords

Transmitter Coil TC8 Operating Manual

Note : Picture is for illustration purposes only.


Features
Non destructive, simple, and easy system to used and
understand the operation.
Identification of wanted cable from the bunch of cables in power
network.
Suitable for single and multi core armored or unarmored power
cables.
High Impulse current to offer reliable good result of identification.
Cyclical pulse repetition for precise cable identification.
Modulation control for better result.
Operation on mains / internal battery supply.
Manual selectable sensitivity control receiver from minimum
to maximum.
Rugged construction and easy to carry on site.
Hand held, small, flexible receiver with Digital display 128x64.
High pulse DC current up to 60 Amp.
Availability of special tongs as per customer's requirement.
Complete system is offered in a robust molded carrying case.

CI 60S-D
Digital Cable Identification System

A Digital Cable Identification System is an essential item in the kit for Applications
fault location of underground power cable networks. It consists of an Cable Identification System can be effectively used to identify
Identification Transmitter, Digital Identification Receiver, and any power cable low, medium, high or extra high voltage single
Identification Tongs. The system is used for the identification of or multi core cable of any grade, size and insulation in any
wanted cables from the bunch of cables in a power cable network. power distribution networks companies.

Precisely identifying a particular cable from a bunch is a common


problem faced by technicians and cable jointers in everyday practice. Working Principle
The wrong identification of a power cable can result in catastrophic or
The saw toothed impulses sent on the wanted cable to the far
fatal results if the cable is cut. This requires the most reliable system
end are given return path to the sending end through the
having no chance for wrong identification.
sheaths armors of all the cables. Current flow direction is
This incorporates all the safety features and gives 100% safe full monitored on all the cables.
identification of the wanted cable, leaving no chance for an accident.
Direction of current flow in the wanted cable is in one direction
whereas it is indifferent in all other cables. Thus the direction
of the current flow identifies the wanted cable.
Function
The Cable Identification System consists of Cable identification
transmitter, Digital Cable identification receiver and Cable
identification Directional Tongs. The saw toothed impulses from the
transmitter are fed into the cable which is to be identified.
Identification directional Tongs applied on the cable receive them as
DC impulse and are feed to the identification receiver unit.

Direction of current of these impulses identifies the wanted cable, on


wanted cable the digital graphical display deflect on right direction
and on other unwanted cable its deflect on wrong direction.
Technical Details CI 60S-D

Specifications
Cable Identification Transmitter PG 60S
Power Supply 230V Ac +10%, 50 Hz, Single phase or from built in-Accumulator with internal charging supply

Impulse Voltage 36 V

Impulse Current 60 Amp

Impulse Sequence I 2.5s

Impulse Sequence II 2.5 and 1 s alternating

Indication Analog moving coil meter for output current, Charging Indication,

Power on indication, Low battery Indication

Operating Time 6 Hrs. Continuous

Working Temp. 0 Deg C~55 Deg C

Storage Temp. -5 Deg C ~ 60 Deg C

Dimensions 242mm(L) x 134mm(W) x 245mm(D) mm

Weight 5.3 kg Approx.

Cable Identification Receiver PR 6D


Sensitivity 6 stages manually selectable from minimum to maximum.

Display Digital graphical display 128 x 64 with back-lit sensing.

Indication Digital Arrow with Right Wrong indication

Power Supply 9V battery (Recommended Duracell)

Working Temp. 00C - 550C

Storage Temp. -50C - 600C

Dimensions 235mm(L) x 130mm(W) x 68mm(D)

Weight 0.5 kg Approx.

Cable Identification Tongs CT120 (Optional CT 150)

Internal Diameter 120 mm

Dimensions 268mm(L) x 160mm(W) x 35mm(D)

Weight 1.08 kg

Standard Accessories
Mains supply cord

Output connecting cables

Earthing cable

Note : Picture is for illustration purposes only.


Features
Test Voltage: 0 to 30kV , 50kV and 80kV
Test Frequency: 0.01 Hz to 0.1 Hz
Displaying information of output current voltage and
waveform with high accuracy.
Measuring Accuracy: + 3 %
Overvoltage protection: if the set limit is exceeded the device
will automatically shut down in less than 20 ms.
Overvoltage protection: if the current setpoint is exceeded
on low voltage side, the device will automatically shut down
in less than 20ms.
Protective resistor in the design of the high voltage output
of the voltage amplifier, which eliminates the need for an
external protective resistor.

MTVLF
Very Low Frequency HV Generator

The MTVLF Series combines modern advanced digital variable


Applications
frequency technology and microcomputer control together, Telemetrics represents a complete line of the most advance
therefore, it can realize the fully automatic voltage boost, stepdown, AC/DC High-Voltage Test Systems with voltage and power
measurement and protection as well as the manual intervention in ratings to meet your testingg requirements. Our systems
the process of automatic voltage boost. The full electronicdesign function in compliance with recognized national and
ensures the small size and light weight. The big LCD screen ensures internation industry testing standards. MTVLF Series units
the clear and visual display and can display the output wave form. available from Telemetrics are designed for safety and ease
The printer outputs test reports. of operation, and readily adapt to development
maintenance of production testing.
Technical Details MTVLF

Testing MTVLF - 30 MTVLF - 50 MTVLF - 80

Rated Voltage (Peak) 30 kV 50 kV 80 kV

Rated Current (Peak) 20 mA 30 mA 30 mA

Measurement Accuracy +3%

Load Carrying Capacity 0.1 Hz < 1.1 μF 0.1 Hz < 1.1 μF 0.1 Hz < 0.5 μF

0.05 Hz < 2.2 μF 0.05 Hz < 2.2 μF 0.05 Hz < 1 μF

0.02 Hz < 5.5 μF 0.02 Hz < 5.5 μF 0.02 Hz < 2.5 μF

General
Power Supply 220 V + 5%

Power Frequency 50 Hz

Stability of Frequency Less than 0.5%

Power Fuse Tube 5A 15 A 20 A

Dimensions 410mm x 340mm x 220 mm

Controller 350mm x 310mm x 410 mm 410mm x 230mm x 520 mm 350mm x 310mm x 410 mm

Bosster 410mm x 230mm x 520 mm

Weight

Controller 4 Kg

Bosster 25 Kg 50 Kg 75 Kg

Operational Environment

Test Current Injection -100C to 500C

Relative Humidity up to 85% RH

Notes : 1. The Instrument is accompanied with Test & Calibration sheet. 2. Test Facilities can be provided at the factory with the available test set-ups only. 3. The company's policy includes
continuous improvement of its product. We, therefore, reserve the right of any deviation from illustration or specifications without notice. 4. Stated accuracies are valid from 10% of the
0 0
range to 95% of the range. 5. Accuracy specified for temperature range of 25 C + 5 C & 55% RH + 10%.
Contact Details
THE MOTWANE MANUFACTURING CO. PVT. LTD.

Regd. Office & Factory :


Gyan Baug Nashik Road, Nashik, 422101 Maharashtra, India Scan the QR code to visit
Motwane’s new website
Pune Unit :
Unit No. 07 & 08, Electronic Sadan No. 2, MIDC, Bhosari, Pune - 411 026

www.motwane.com

Nashik Head Office : 91-0253 -2463752 / 53


Pune office : 91-20-27122936, 27123176

https://www.linkedin.com/company/motwanemanufacturing

You might also like