You are on page 1of 11

Page 1 of 11

Diagnostic Report
Created by OBDwiz - OCTech, LLC www.obdsoftware.net

Date: 3/2/2024 1:38:52 PM

VIN: VF1HR3NB8LC347744
Manufacturer: Renault
Model:
Year: 2020

Monitor Status Report

Name Continuous Available Complete


Misfire Yes Yes Yes
Fuel System Yes Yes Yes
Components Yes Yes Yes
Catalyst No Yes Yes
Heated Catalyst No No No
Evap System No No No
Secondary Air System No No No
AC Refrigerant No No No
Oxygen Sensor No Yes Yes
Oxygen Sensor Heater No Yes Yes
EGR System No Yes Yes

MIL Off
Number of Confirmed Codes: 0
Readiness Standard: WI - 2001 and newer

This vehicle is ready for emissions testing.

Trouble Code Report

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 2 of 11

There are no pending, stored, or permanent diagnostic trouble codes (DTCs).

Mode $01 - Powertrain Diagnostic Data

PID Description Value Units


SAE 0x03 Fuel system 1 status 2
SAE 0x03 Fuel system 2 status 0
SAE 0x04 Calculated load value 21.96 %
SAE 0x05 Engine coolant temperature 165.2 °F
SAE 0x06 Short term fuel % trim - Bank 1 -1.56 %
SAE 0x07 Long term fuel % trim - Bank 1 -0.78 %
SAE 0x0C Engine RPM 687.5 RPM
SAE
Vehicle speed 0 MPH
0x0D
SAE 0x0E Ignition timing advance for #1 cylinder 10 deg
SAE 0x0F Intake air temperature 107.6 °F
SAE 0x10 Mass air flow rate 0.36 lb/min
SAE 0x11 Absolute throttle position 4.31 %
SAE 0x13 Location of oxygen sensors 3
SAE 0x15 O2 voltage (Bank 1, Sensor 2) 0.28 V
SAE 0x15 Short term fuel trim (Bank 1, Sensor 2) 99.219 %
OBD requirements to which vehicle or engine is
SAE 0x1C 6
certified
SAE 0x1F Time since engine start 309 sec
SAE 0x21 Distance traveled while MIL is activated 0 miles
SAE 0x24 O2 sensor lambda (Bank 1, Sensor 1) 0.996
SAE 0x24 O2 sensor voltage wide range (Bank 1, Sensor 1) 2.235 V
SAE 0x2E Commanded evaporative purge 0 %
SAE 0x30 Number of warm-ups since DTCs cleared 255
SAE 0x31 Distance traveled since DTCs cleared 35037.88 miles
SAE 0x3C Catalyst temperature (Bank 1 Sensor 1) 154.4 °F
SAE 0x42 Control module voltage 13.12 V
SAE 0x43 Absolute load value 15.69 %
SAE 0x44 Fuel/Air commanded equivalence ratio 1

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 3 of 11

SAE 0x45 Relative throttle position 2.35 %


SAE 0x47 Absolute throttle position B 4.31 %
SAE 0x49 Accelerator pedal position D 0 %
SAE
Accelerator pedal position E 0 %
0x4A
SAE 0x4C Commanded throttle actuator control 4.31 %
SAE
Engine run time run while MIL is activated 0 min
0x4D
SAE 0x4E Engine run time since DTCs cleared 65535 min
SAE 0x51 Fuel type 1
Aux 0x00 Input voltage read by the scan tool 0 V

Mode $02 - Freeze Frame

A freeze frame was found but the vehicle has no stored trouble codes. This indicates that
the freeze frame could contain out-of-date and inaccurate information.

PID Description Value Units


Freeze frame
0x02 P0579
DTC
MIL Off, # Trouble Codes 0, Misfire: Available =
False, Complete = False Fuel System: Available =
False, Complete = False Components: Available =
Number of False, Complete = False Catalyst: Available = False,
trouble codes, Complete = False Heated Catalyst: Available = False,
MIL indicator Complete = False Evap System: Available = False,
0x01
on/off, and Complete = False Secondary Air System: Available =
available False, Complete = False AC Refrigerant: Available =
onboard tests False, Complete = False Oxygen Sensor: Available =
False, Complete = False Oxygen Sensor Heater:
Available = False, Complete = False EGR System:
Available = False, Complete = False
Fuel system 1
0x03 2
status
Fuel system 2
0x03 0
status
Calculated load
0x04 45.1 %
value
Engine coolant
0x05 181.4 °F
temperature

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 4 of 11

Short term fuel


0x06 0 %
% trim - Bank 1
Long term fuel
0x07 3.12 %
% trim - Bank 1
0x0C Engine RPM 1400 RPM
0x0D Vehicle speed 27.34 MPH
Ignition timing
0x0E advance for #1 30 deg
cylinder
Intake air
0x0F 64.4 °F
temperature
Mass air flow
0x10 1.71 lb/min
rate
Absolute throttle
0x11 14.12 %
position
O2 voltage
0x15 (Bank 1, Sensor 0.11 V
2)
Short term fuel
0x15 trim (Bank 1, 99.219 %
Sensor 2)
Time since
0x1F 867 sec
engine start
Distance
0x21 traveled while 0 miles
MIL is activated
O2 sensor
0x24 lambda (Bank 1, 0.979
Sensor 1)
O2 sensor
voltage wide
0x24 2.185 V
range (Bank 1,
Sensor 1)
Commanded
0x2E evaporative 77.65 %
purge
Number of
0x30 warm-ups since 255
DTCs cleared
Distance
0x31 traveled since 28744.63 miles
DTCs cleared
Catalyst

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 5 of 11

temperature
0x3C (Bank 1 Sensor 615.2 °F
1)
Misfire: Available = False, Complete = False Fuel
System: Available = False, Complete = False
Components: Available = False, Complete = False
Catalyst: Available = False, Complete = False Heated
Catalyst: Available = False, Complete = False Evap
Monitor status
System: Available = False, Complete = False
0x41 this driving
Secondary Air System: Available = False, Complete =
cycle
False AC Refrigerant: Available = False, Complete =
False Oxygen Sensor: Available = False, Complete =
False Oxygen Sensor Heater: Available = False,
Complete = False EGR System: Available = False,
Complete = False
Control module
0x42 13.36 V
voltage
Absolute load
0x43 37.65 %
value
Fuel/Air
commanded
0x44 0.98
equivalence
ratio
Relative throttle
0x45 10.2 %
position
Absolute throttle
0x47 14.12 %
position B
Accelerator
0x49 19.61 %
pedal position D
Accelerator
0x4A 19.22 %
pedal position E
Commanded
0x4C throttle actuator 14.12 %
control
Engine run time
0x4D run while MIL is 0 min
activated
Engine run time
0x4E since DTCs 65535 min
cleared
0x51 Fuel type 1

Mode $05 - Oxygen Sensors

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 6 of 11

Sensor Available
Bank 1 - Sensor 1 Yes
Bank 1 - Sensor 2 Yes
Bank 1 - Sensor 3 No
Bank 1 - Sensor 4 No
Bank 2 - Sensor 1 No
Bank 2 - Sensor 2 No
Bank 2 - Sensor 3 No
Bank 2 - Sensor 4 No

Mode $06 - On-Board Monitoring

Component Description Value Minimum Maximum Units Result


$01 - Exhaust
TID $83 -
Gas Sensor
Manufacturer 2.185 0.4 65.535 V Pass
Monitor Bank 1
Defined
– Sensor 1
$01 - Exhaust
TID $84 -
Gas Sensor
Manufacturer 2.185 0 4.399 V Pass
Monitor Bank 1
Defined
– Sensor 1
$01 - Exhaust
TID $85 -
Gas Sensor
Manufacturer 2.045 0 2.149 V Pass
Monitor Bank 1
Defined
– Sensor 1
$01 - Exhaust
TID $86 -
Gas Sensor
Manufacturer 3.54 2.25 65.535 V Pass
Monitor Bank 1
Defined
– Sensor 1
$01 - Exhaust
TID $8D -
Gas Sensor
Manufacturer 0.166 0.04 65.535 Pass
Monitor Bank 1
Defined
– Sensor 1
$01 - Exhaust
TID $8E -
Gas Sensor
Manufacturer 0.166 0.04 65.535 Pass
Monitor Bank 1
Defined
– Sensor 1
$01 - Exhaust
Gas Sensor TID $8F -

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 7 of 11

Monitor Bank 1 Manufacturer


-0.13 -32.768 -0.04 Pass
– Sensor 1 Defined
$01 - Exhaust
TID $90 -
Gas Sensor
Manufacturer -0.13 -32.768 -0.04 Pass
Monitor Bank 1
Defined
– Sensor 1
$02 - Exhaust TID $07 - Minimum
Gas Sensor sensor voltage for
0.13 0 0.17 V Pass
Monitor Bank 1 test cycle
– Sensor 2 (calculated)
$02 - Exhaust TID $08 - Maximum
Gas Sensor sensor voltage for
0.73 0.73 2.55 V Pass
Monitor Bank 1 test cycle
– Sensor 2 (calculated)
$02 - Exhaust
TID $80 -
Gas Sensor
Manufacturer 0.81 0 1.19 V Pass
Monitor Bank 1
Defined
– Sensor 2
$02 - Exhaust
TID $81 -
Gas Sensor
Manufacturer 0.75 0.12 2.55 V Pass
Monitor Bank 1
Defined
– Sensor 2
TID $80 -
$21 - Catalyst
Manufacturer 41 16 255 Pass
Monitor Bank 1
Defined
TID $82 -
$21 - Catalyst
Manufacturer 0 0 0 Pass
Monitor Bank 1
Defined
TID $80 -
$35 - VVT
Manufacturer 0.5 -13 13 deg Pass
Monitor Bank 1
Defined
TID $81 -
$35 - VVT
Manufacturer 0.5 -13 13 deg Pass
Monitor Bank 1
Defined
TID $82 -
$35 - VVT
Manufacturer 0.5 -64 63.5 deg Pass
Monitor Bank 1
Defined
TID $83 -
$35 - VVT
Manufacturer 0.5 -64 63.5 deg Pass
Monitor Bank 1
Defined
TID $86 -
$35 - VVT
Manufacturer -1 -13 13 deg Pass
Monitor Bank 1
Defined
$41 - Exhaust
Gas Sensor TID $81 -

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 8 of 11

Heater Monitor Manufacturer


Bank 1 – Sensor Defined 2.135 0.24 4.779 V Pass
1
$42 - Exhaust
Gas Sensor TID $80 -
Heater Monitor Manufacturer 1.88 0.12 4.71 V Pass
Bank 1 – Sensor Defined
2
$81 - Fuel TID $80 -
System Monitor Manufacturer 105.33 75.01 137.99 % Pass
Bank 1 Defined
$81 - Fuel TID $81 -
System Monitor Manufacturer 0 0 9 counts Pass
Bank 1 Defined
$A1 - Misfire TID $80 -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $81 -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $82 -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $83 -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $88 -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $89 -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $8A -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $8B -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $8C -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $91 -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 9 of 11

$A1 - Misfire TID $92 -


Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
$A1 - Misfire TID $93 -
Monitor Manufacturer 0 0 65534 counts Pass
General Data Defined
TID $0B - EWMA
(Exponential
$A2 - Misfire Weighted Moving
0 0 65535 counts Pass
Cylinder 1 Data Average) misfire
counts for last ten
(10) driving cycles
TID $0C - Misfire
counts for
$A2 - Misfire last/current driving
0 0 65535 counts Pass
Cylinder 1 Data cycles (calculated,
rounded to an integer
value)
TID $0B - EWMA
(Exponential
$A3 - Misfire Weighted Moving
0 0 65535 counts Pass
Cylinder 2 Data Average) misfire
counts for last ten
(10) driving cycles
TID $0C - Misfire
counts for
$A3 - Misfire last/current driving
0 0 65535 counts Pass
Cylinder 2 Data cycles (calculated,
rounded to an integer
value)
TID $0B - EWMA
(Exponential
$A4 - Misfire Weighted Moving
0 0 65535 counts Pass
Cylinder 3 Data Average) misfire
counts for last ten
(10) driving cycles
TID $0C - Misfire
counts for
$A4 - Misfire last/current driving
0 0 65535 counts Pass
Cylinder 3 Data cycles (calculated,
rounded to an integer
value)
TID $0B - EWMA
$A5 - Misfire (Exponential
Weighted Moving 0 0 65535 counts Pass
Cylinder 4 Data
Average) misfire
counts for last ten

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 10 of 11

(10) driving cycles


TID $0C - Misfire
counts for
$A5 - Misfire last/current driving
0 0 65535 counts Pass
Cylinder 4 Data cycles (calculated,
rounded to an integer
value)

Mode $09 - Vehicle Information

General Information

Description Value
Vehicle Identification Number VF1HR3NB8LC347744
Calibration ID - $7E0 HMLGT6221R0294S
Calibration ID - $7E1 HMLGT5370R
Calibration ID - $7E1 310321028R
Calibration Verification Number - $7E0 1BA8CEBF
Calibration Verification Number - $7E1 00002F57

In-Performance Tracking

Counter Description Value


0x00 OBD Monitoring Conditions Encountered Counts 1669
0x01 Ignition Cycle Counter 9351
0x02 Catalyst Monitor Completion Counts Bank 1 1962
0x03 Catalyst Monitor Conditions Encountered Counts Bank 1 1669
0x06 O2 Sensor Monitor Completion Counts Bank 1 2236
0x07 O2 Sensor Monitor Conditions Encountered Counts Bank 1 1669
0x0A EGR and/or VVT Monitor Completion Condition Counts 1286
0x0B EGR and/or VVT Monitor Conditions Encountered Counts 1669
0x10 Secondary O2 Sensor Monitor Completion Counts Bank 1 3962
Secondary O2 Sensor Monitor Conditions Encountered Counts Bank
0x11 1669
1

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024
Page 11 of 11

file:///C:/Users/Gaby/AppData/Local/Temp/%7B3FEC3A54-CBAB-499d-B7AC-1E50A... 04/03/2024

You might also like