1 GT2-70-M-E
Precautions on Regulations and Standards Q Sensor head parts
Q CE Marking O Sensor head
O EMC Directive (2004/108/EC) GT2-P12K/P12 GT2-P12KL/P12L GT2-P12KF/P12F GT2-PA12K/PA12
• Applicable standard EMI: EN61326-1, Class A
EMS: EN61326-1
• This product is designed for use in industrial environments.
Remarks: This specification does not give any guarantee that the end-product with this product
incorporated complies with the essential requirements of EMC Directive. The manufacturer of the end- Sensor head x 1 Sensor head x 1 Sensor head x 1 Sensor head x 1
Precautions on handling x 1 Precautions on handling x 1 Precautions on handling x 1 Precautions on handling x 1
product is solely responsible for the compliance on the end-product itself according to EMC Directive. Nut x 1
Q UL Certificate Key spanner x 1
UL File No. E120439 (Category: NRNT2/NRNT8) GT2-S1 GT2-S5 GT2-PA12KL/PA12L
• Use the power supply with Class 2 output defined in NFPA70
(NEC: National Electrical Code).
• GT2 series are evaluated as open type devices. These products Sensor head x 1 Sensor head x 1 Sensor head x 1
can not be a part of an enclosure. Precautions on handling x 1 Precautions on handling x 1 Precautions on handling x 1
GT2-H12KF/H12F GT2-H12KLF/H12LF
Package Contents Sensor head x 1 Sensor head x 1
Precautions on handling x 1 Precautions on handling x 1
The product package of each model should include the following items. Nut x 1 Nut x 1
Check that all items are included before use. Key spanner x 1 Key spanner x 1
HI
GO
P-H
B-H
P-P
CALC
HI
GO
P-H
B-H
P-P
CALC
GT2-H32 GT2-H32L GT2-A32
LO LO
SET SET
1 1
2 2
3 3
TIM TIM
SET HI SET
HI PV
PV
LO PRES LO PRES
ET
ET MO
MO DE
DE SER
SER IES
IES
1
2
3
TIM
Amplifier x 1 1
2
3
TIM
HI
Amplifier x 1
any parts are found to be defective or broken, please contact your
HI RV
RV LO PRESET
LO PRESET
Instruction manual x 1
GT2-70-M-E 2
Mounting the Amplifier and Wiring O Panel mount type (Main unit)
This section describes how to mount the panel mount type:
Q Mounting the amplifier GT2-75N/75P (Main unit).
O DIN rail mount type (Main unit) 1 Create a panel opening for mounting referring to the dimensions below.
This section describes how to mount the DIN rail mount type: 45
the DIN rail. While inserting the main unit in X=24 x (Number of amplifiers -1)+21
X
the direction of Arrow (1), push the body
down in the direction of Arrow (2). (2) (1)
69.5 min.
2 To detach the amplifier, while pushing the main unit in the direction
+0.4
21 -0
of Arrow (1), pull the body up in the direction of Arrow (3).
When using a fixture (Optional item: OP-76877), mount as shown below.
45 Panel cut dimension
2 Insert the main unit, back end first, into the opening of the panel.
Fixture: OP-76877 3 Insert the panel mounting bracket in the direction shown below into the main
O DIN rail mount type (Expansion unit) unit from the back, then fit the front protective cover to the main unit face.
This section describes how to mount the DIN rail mount type Front protective cover
(Expansion unit: GT2-72N/72P/72CN/72CP). Amplifier
Panel
The expansion unit can only be used in addition to the main unit.
Up to 14 expansion units can be added to one main unit. Panel mounting bracket
Expansion unit
1 Create panel openings for mounting according to the number of
expansion units to be mounted (the expansion unit to be added).
Refer to above, "Panel mount type (Main unit)", for details about
Connector
panel cut dimensions.
4 Mount the end units (OP-26751: a set of two pieces) sold 2 Mount the amplifier (the expansion unit to be added) to the panel.
separately on both sides of the amplifiers (the main unit and
the expansion unit), then fix the end units with screws on the Refer to above "Panel mount type (Main unit)", for details about how
upper part of each end unit (2 points x 2 units). to mount.
The mounting method of the end unit is the same as that of the amplifier. 3 Connect the amplifiers (the main unit and the expansion unit) with an
expansion cable.
End unit
Expansion
End unit cable Expansion cable
3 GT2-70-M-E
Q Wiring of amplifier Connecting and Mounting the Sensor Head
NOTICE Insulate unused I/O wires individually.
Q Names of parts of the sensor head
O How to connect the power cable to the DIN-mount quick disconnect type ● GT2-P12K(L)/P12(L) ● GT2-P12KF/P12F ● GT2-PA12K/PA12
Quick disconnect type amplifiers must be connected with the power
Air supply hole
cable (I/O cable) GT2-CA2M/CA10M (sold separately). Relay connector Relay connector
The accessory power cable (I/O cable) must be connected to the Spindle Spindle
amplifier of the panel mount type. Dust seal
Contact Contact
GT2-70-M-E 4
• When connecting the connector, be sure to insert it Q Mounting the sensor head
straight, and tighten it securely. (Recommended O Mounting directly to the jig
tightening torque: 0.4 to 0.5 N•m*) Before mounting the sensor head directory to the jig, create a hole in the jig. Attach the sensor
If the connection is not tight enough, the connector head using the optional head mounting bracket sold separately. A mounting bracket is provided
may be loosened by vibration or other causes, with the GT2-P12KF/P12F/H12K(L)F/H12(L)F as standard. Attach it with the supplied nut.
leading to a connection failure. O GT2-P12K(L)/P12(L)/PA12K(L)/PA12(L)/ O GT2-H32(L)/H50/A32/A50
Mounting
NOTICE (* After tightening it firmly by hand, use pliers or other illustration S1/S5/H12K(L)/H12(L)/A12K(L)/A12(L) Optional head mounting
tools to rotate it about 30° for further tightening.) bracket D (OP-84327)
• When the head is attached to a moving part, and the Optional head mounting
cable will be repeatedly bent, ensure that the cable bracket A (OP-76874)
between the sensor head and relay connector does
not bend. Instead, bend the sensor head cable
Tightening sleeve Nut
connecting the relay connector and the amplifier. Tightening sleeve Nut
connector of the sensor head. Optional head mounting When mounting the GT2-
Arrow bracket C (OP-84396) H32L facing upward, be
sure to use the mounting
holes on the side of the
NOTICE sensor head. If the
2 Secure the connector with this Tightening sleeve Nut sensor head is mounted
device's cable screw. using head mounting
bracket D, the spindle
Key wrench
may not fully extend.
1 Cut the jig to create a sensor head mounting hole referring to the
• When connecting the connector, be sure to insert it illustration below.
straight, and tighten it securely. (Recommended O GT2-P12K(L)/P12(L)/PA12K(L)/PA12(L)/ O GT2-H32(L)/H50/A32/A50
tightening torque: 0.4 to 0.5 N·m*)
If the connection is not tight enough, the connector S1/S5/H12K(L)/H12(L)/A1K2(L)/A12(L)
0.5 to 1.0*2
may be loosened by vibration or other causes, ±1°
0.5 to 1.0*2
±1°
NOTICE 45° 45°
leading to a connection failure. A A
(* After tightening it firmly by hand, use pliers or other Tightening Nut Tightening
Nut
tools to rotate it about 30o for further tightening.)
sleeve mounting sleeve
1 insertion insertion mounting
*
27 ) side side
• The M8 L-shaped connector (GT2-CHL*M) cannot be
+0.0 05 side .1 6
+00.00 side
8 ( +0.0 4+
φ1 0G φ1 5.5 to 11.3*2
used with the GT2-H32(L)/H50/A32/A50. φ0.025 A
5.5 to 11.3*2
φ0.025 A (Unit: mm)
(Unit: mm)
To disconnect the sensor head connection cable, reverse the steps above. *1 For head mounting bracket C *2 Processing accuracy : ±0.05
φ10 +0.1
+0.005
Click
2 Insert the tightening sleeve into the hole (from the Chamfered side),
Unlocked
and loosely tighten with the nut.
Sensor head
Tightening sleeve
To disconnect the sensor head connection cable,
Chamfered side
NOTICE press and hold the lock lever on the side of the
connecter and disconnect the cable. Chamfered side
2 Put the lock cover on the connector, and lock the lock cover. Nut
Lock cover
Nut
Locked
In the illustration on the left above, if the nut is fully tightened when
NOTICE
the sensor head is not yet inserted, the fixture will become deformed.
3 Insert the sensor head in the tightening sleeve. While securing the tightening
sleeve with the included key wrench, tighten the nut with a separate wrench.
O Panel mount type
1 Remove the lock cover of the connector of the sensor head
Wrench
connection cable, and insert the sensor head connection cable into
the connector on the back of the amplifier until it clicks.
Lock cover
Key wrench
Tightening the nut while fixing the sensor head may lead to damage.
• The tightening torque for mounting bracket A (OP-76874), mounting
Orient the connector so that the lock lever is at the left side.
bracket C (OP-84396), and the nuts supplied with the GT2-H12K(L)F/
To disconnect the sensor head connection cable, H12(L)F/P12KF/P12F is between 5 and 7 N•m (the recommended
NOTICE press and hold the lock lever on the side of the tightening torque is 5 N•m) for all products other than the GT2-S5
NOTICE
connecter and disconnect the cable. and is between 4 and 5 N•m (the recommended tightening torque is 4
N•m) for the GT2-S5. Apply tightening torque between 15 and 18 N•m
(20 to 23 N•m when using the GT2-A32/A50) to head mounting
2 Put the lock cover on the connector, and lock the lock cover. bracket D (OP-84327). Use the wrench that matches the nut width.
Lock cover
• Care must be taken not to damage the dust boot when tightening.
O Using mounting bracket F
Locked
1 Refer to the illustration below and cut the jig to create a sensor head mounting hole.
• GT2-P12K(L)/P12(L)/PA12K(L)/PA12(L)/S1/S5
8.5
M4
x0
.7
5 GT2-70-M-E
2 Loosen the screw on the side of mounting bracket F using the O Mounting to the mounting holes
supplied hexagonal wrench. The mounting holes on the side of the GT2-H32(L)/H50/A32/A50
unit can be used to install to the side of a table or other surface.
Mounting illustration
M4 screws (Mounting hole dimensions)
23 ± 0.15 mm
M4 tap
3 Align mounting bracket F with the hole made in step 1 and secure it
using the supplied hexagonal wrench.
• Roughness of the mounting surface may cause the
sensor to tilt, and sufficient accuracy may not be
obtained. When performing a high-accuracy
NOTICE
measurement, use a jig to mount the sensor head.
"Mounting directly to the jig" (page 5)
• Apply tightening torque between 1.2 and 1.5 N•m.
1 Insert the tightening sleeve into the mounting bracket from the side
with a depression, and loosely tighten with the nut.
Tightening sleeve • For best results, cut the end of the tube at a right angle,
and ensure that the outer perimeter is not damaged,
and that it still maintains a circular cross section.
Mounting bracket NOTICE • If the tube is not properly inserted, air leakage may result.
• After attaching, pull on the tube to make sure it is secure.
• Use a urethane tube. Make sure it also has a bending
radius of at least 50 mm.
Nut Notice the correct angle of the tightening sleeve. • Detaching the air tube
To detach the air tube, pull the air tube in the direction of the arrow,
as indicated in the figure below.
• If the sleeve is inserted from the wrong side, the Relay connector
Air tube
sensor head cannot be secured.
• Strongly tightening the nut without the sensor head
NOTICE inserted may deform the tightening nut.
• Head mounting bracket B cannot be used in
combination with head mounting bracket C (OP-
84396) or head mounting bracket D (OP-84327).
2 Insert the sensor head into the tightening sleeve, and tighten
the nut with a wrench. NOTICE Before detaching the tube, be sure to stop any air flow.
3 Secure the sensor head with M4 screws. • For best results, cut the end of the tube at a right
Mount the sensor head with the model label on top. For GT2-P12K (L)/ angle, ensure that the outer perimeter is not damaged,
P12 (L)/PA12K /PA12, mount so that the head indicator is on top. and that it still maintains a circular cross section.
M4 screws • If the tube is not properly inserted, air leakage may
result (see figure below).
NOTICE
GT2-70-M-E 6
• Detaching the air tube Q How to mount the lift lever
To detach the air tube, (1) press down on the release ring, (2) pull out the tube.
Mount the lift lever (OP-84397) between the spindle and the contact.
Secure the spindle with the lift lever and attach/detach the contact.
(2)
(1)
Release ring
• Before detaching the tube, be sure to stop any air flow. Amplifier display
NOTICE • Press down on the release ring evenly from both sides, and pull the tube out. Uneven
pressure may result in damage to the tube or damage to the operation of the air cylinder. Q Names of parts of the amplifier
O For GT2-A12K/A12/A32/A50 when an IP67 enclosure rating is required Digital LED display Special output indicator
Status indicator Arrow buttons
To maintain an IP67 enclosure rating, the following must be satisfied: GT2-71
• Firmly connect tubing with 2.5 mm inner diameter to the exhaust
port until it bottoms out. Detection level
Ensure that the tube end is free of dirt or water. indicator
• To further decrease spindle movement speed, use a coil-shaped 5. HIGH setting value display
tube (OP-87986) or similar to increase the distance between the air *1 This display appears only while the calculation function is used
NOTICE
supply hole and the speed controller. and an expansion unit is connected.
• The speed controller will not operate if installed in the reverse direction. *2 • This display appears only when [5out] is selected for [16.
Special output setting] in the basic setting mode.
Contact • This display does not appear on GT2-71MCN/71MCP.
1. P.V. value display ([P.V. = Present Value] Criterion value display)
This section describes how to replace the contact, and how to mount the lift lever. Displays a value to be used for output judgment.
• Detach the sensor head from the device or fixture (metal plating, 2. Calculated value display
etc.) before replacing the contact. Displays a calculated value such as a maximum or minimum value
• When applying pliers to the contact, be sure not to rotate the main of several detection points created when adding an expansion
part and cover the contact with a cloth. unit(s) (Displayed only when an expansion unit(s) is added).
• Never apply tightening torque over 0.2 N•m when attaching a contact. 3. R.V. value display ([R.V. = Raw Value] Raw value display)
NOTICE • Fix the roller contact (OP-77680) or the offset contact (OP-77683) Displays an actual detection value of the detection target.
with the fixing nut in the same direction as in actual use. 4. HH setting value display while using 5-output function
• Applying an adhesive, a thread locking agent, is recommended to Displays/Sets the setting value to set above the HIGH setting value.
prevent the nut from getting loose. 5. HIGH setting value display
• Position the roller contact carefully in the proper direction. Care Displays/Sets an upper limit value of the range of the detection target.
must be taken not to apply misdirected force to the shaft. 6. LOW setting value display
Displays/Sets a lower limit value of the range of the detection target.
Q How to replace the contact 7. LL setting value display while using 5-output function
Displays/Sets the setting value to set below the LOW setting value.
While securing the spindle with the accessory key wrench, detach the 8. Preset value setup display
contact with pliers. Then attach a new contact. Displays/Sets an arbitrary value to be added to or subtracted from
You cannot use the key wrench with the GT2-S1/S5, so use your the display value.
hands to secure the head.
Spindle
Zero-Point Correction
When you use this equipment for the first time or after the sensor head
Pliers is changed, be sure to correct the reference zero point.
Contact • When "------" is displayed, zero-point correction is disabled.
Reference
• Zero-point correction can be performed approx. 1 million
times. When zero-point calibration is frequently used, you
Cover the contact can perform setting so that the zero-point calibration will not
Key wrench with a cloth be written into the memory. Refer to "Origin Alignment" in the
"GT2-70 Series User's Manual" for details.
7 GT2-70-M-E
Q Setup using buttons 2 Detect the good workpiece and press the [SET] button to capture the
detected value.
1 Set any main display and perform the "SEt" and the detected value blink alternately, and the value of the
detection of the detection target (master good workpiece is fixed.
workpiece) to serve as a reference for zero-
point correction. Master workpiece 3 Detect the HIGH defective workpiece and press the [SET] button to
capture the detected value.
2 Press the [PRESET] button (white button) with the master workpiece The median value of this detected value and the one captured in step 2 blinks.
HIGH setting value is fixed.
being detected.
After "PrESEt" has blinked several times on the digital LED display 4 Press the right Arrow button until the LOW
of the amplifier, "0.000.0"* will appear. setting value display of the main display
The zero-correction is completed. appears.
LOW setting value display
5 Detect the good workpiece again and press the
[SET] button to capture the detected value.
6 Detect the LOW defective workpiece and press the [SET] button to
capture the detected value.
* When the preset function is set, the preset value will appear. The median value of this detected value HIGH
and the one captured in step 5 blinks. setting value
Q Setup using external input (Pink wire) LOW setting value is fixed. LOW
Two-point tuning is completed. setting value
1 Perform detection of the target (master workpiece) to serve as a
Press the left/right Arrow buttons to HIGH defective Good LOW defective
reference for zero-point correction. return to the P.V. value display. workpiece workpiece workpiece
2 Connect the pink wire to the appropriate terminal. Q Preset
Refer to page 15 of this manual for details about external input circuit diagrams. This function displays the value obtained by adding or subtracting a
preset value to or from the detected value.
Setup of Limit Values By using this function and the zero point correction function together,
The limit values are an upper limit value (HIGH setting value) and a you can set an arbitrary value as a reference point of the work.
lower limit value (LOW setting value). Setting these values enables Refer to "Preset Function" in the "GT2-70 Series User's Manual" for
three types of judgment (display/output): above the upper limit (HIGH), details about the preset function.
below the lower limit (LOW), and within the range (GO). Q Bank switching
Q Manual setup of limit values By using the bank function, the setting values of the HH side, HIGH
The following shows how to set manually an upper limit value (HIGH side, LOW side, LL side, preset point, and the preset value can be
setting value) and a lower limit value (LOW setting value). registered up to four patterns.
The bank switching is useful when there are multiple detection targets
1 When in the main display, press the left/ since the pre-registered settings (four patterns) can be easily switched.
right Arrow buttons until the HIGH Refer to "Bank Function" in the "GT2-70 Series User's Manual" for
setting value display appears. details about the bank function.
2 Enter an upper limit value (HIGH setting HIGH setting value display Q Limit output function
value) with the top/bottom Arrow buttons. This function can detect and output the mechanical movement of the spindle
3 Press the right Arrow button to display the on the contraction and extension sides. The stroke end of both sides can be
detected, so this function can be used for interlocking the device.
LOW setting value display.
The limit output function cannot be used on GT2-71MCN/
4 Enter a lower limit value (LOW setting Reference
71MCP (analog output type).
value) with the top/bottom Arrow buttons. LOW setting value display
The setup of range criteria values is Q 5-output
completed. This function can increase the output levels to 5 levels: HH, HIGH,
To return to the P.V. value display, press the left/right Arrow buttons. GO, LOW, and LL. HH/LL can be set in the same way as HIGH/LOW.
Refer to "Setting 5-output" in the "GT2-70 Series User's Manual" for
details about the 5-output function.
Tips for Convenient Functions The 5-output function cannot be used on GT2-71MCN/
Reference
Q Automatic setup of limit values 71MCP (analog output type).
This function automatically sets an upper limit value (HIGH setting Q Analog output function
value) and a lower limit value (LOW setting value).
For master workpieces, set by "tolerance tuning"; and for actual On GT2-71MCN/71MCP, the analog current (4 to 20 mA) is output
works (good or defective), set by "two-point tuning". based on the measurement value (R.V.). The upper limit value and
the lower limit value can be set to a desired value.
O Tolerance tuning Refer to "Analog Output Settings" in the "GT2-70 Series User's
This is a method for setting a range based on Manual" for details about the analog output function.
the detection value of a master workpiece Current output
when the master workpiece is available.
HIGH setting value
20mA
Tolerance tuning setting range
LOW setting value
GT2-70-M-E 8
Number of units connected Setting item Initial value
Calculation
No. Description Calculation Calculation Static hold delay stability criterion dEFALt
function
mode only mode
Displays a degree of twist obtained from 3 units only 4 units only Static hold delay stability width 0.0100
C6 Twist the values of four detection points Calculation mode setting noCALc
C7 Warpage Displays a degree of warpage obtained
from the values of three detection points 2 units only 3 units only Calculation method C1.mAX
Displays a thickness obtained by *1 When using GT2-P12K (L)(F)/P12 (L)(F)/PA12K /PA12.
C8 Thickness sandwiching the detection target between 1 unit only 2 units only Default values of basic settings
the main unit and the expansion unit Setting item Initial value
O Calculation mode Measurement Direction change nor
When "Calculation mode" is selected in "A1. Calculation mode", the main unit
outputs the calculation result, while the expansion unit does not. Only the head Multiplier 1.0
indicator operates in the same way as the one on the main unit. (Except when Output mode no
"C5. Reference difference" is selected for the calculation method) Displayed number of digits 0.0001
Refer to "Calculation with expansion unit" in the "GT2-70 Series User's Manual"
for details about the calculation function. Hysteresis 0.0030
The calculation mode can be selected only on the main unit Batch input setting onE
Reference
with one or more expansion units connected.
Special output setting noUSE
O Calculation only mode
When calculation only mode is selected in [A1. Calculation mode], Limit output switch (HH) position 0.5000
only the main unit outputs the calculation result, and the expansion Limit output switch (LL) position 0.5000
unit outputs the judgment according to each setting.
Refer to "Calculation with expansion unit" in the "GT2-70 Series * GT2-71MCN/71MCP (analog output type) has the following
User's Manual" for details about calculation only mode. setting items and initial values for items 16 to 18.
• The calculation only mode is available only on the main Setting item Initial value
unit with two or more expansion units connected.
• When the calculation only mode is Analog range setting dEFALt
selected, "C5. Reference difference" Free range settings (Hi side) (Head stroke)*
cannot be selected for the
NOTICE calculation method. Free range settings (Lo side) 0.0000
• When the calculation only mode is * Ex.: When the sensor head is GT2-H12, the initial value is "12.0000".
selected, the sensor head cannot be Initial values of added function settings
connected to the main unit. Attach
the included "head connector label" Setting item Initial value
to the head connector of the main unit. Select preset data r.v.
Q Keylock Preset memory yES
The keylock allows you to avoid erroneous button operation during detection. Preset point setting onE
When the keylock is active, setup operations other than changing the display are disabled. Power-saving function (ECO) oFF
Reference The keylock can be set on the main display only.
Jam detection function oFF
O Set the keylock Jam detection position 0.5000
When keylock is active, setup operations other than main display
switching and the [PRESET] button operation are disabled. Initial values of calibration function settings
When in the main display, while pressing Setting item Initial value
the [MODE] button, press the upper Arrow Calibration function setting (Not initialized)
button for at least two seconds.
The keylock display will appear for several 2nd point target value 5.0000
seconds and then change to the main display.
MODE
+ (Press for at least two seconds) Keylock display
Q Switching the display unit
The display unit can be switched from the initialization screen.
O Set full keylock This section explains how to switch from "mm" display to "inch" display.
When full keylock is active, setup operations other than main display
switching are disabled.
1 Display "rSt.YES" from the initialization screen.
Press the down Arrow button for at least two Refer to "Initialization" for more details on how to display "rSt.YES".
seconds while pressing the [MODE] button in 2 Pressing the [MODE] button, press the [SET] button for 2 seconds or more.
the main display.
MODE
3 Use the up and down Arrow button to select "inch".
+ (Press for at least two seconds)
Full keylock display 4 Press the [MODE] button.
O Cancel the keylock or full keylock "rSt.End" will appear.
Press "up or down" Arrow button for at least Switching the display unit is completed.
two seconds while pressing the [MODE] button
in the main display when the keylock is active. Setting Mode Display
The keylock cancel display will appear for several
seconds and then change to the main display.
MODE
Keylock cancel display Q Function setting mode
+ or (Press for at least two seconds) You can set the following functions in the function setting mode.
Q Initialize (Reset to the default state) No. Item Description
• Initialization can be set on the main display only. Detection mode Select the detection mode.
Reference
• Initialization cannot cancel "span adjustment results". Hold update When "P-H", "b-H", or "P-P" is selected in , select "Timing
• Refer to "Calibration" in the "GT2-70 Series User's Manual" for details method input" or "Regular update" for the update timing of the hold value.
about how to set "Span adjustment" to the factory default state. Response Longer response time makes the average
• During initialization, performing other steps than the following ones
stops initialization, and the display returns to the main display.
time data time longer, which stabilizes the value.
For the timing input, select "External timing"
Timing type
1 When in the main display, while pressing the or "Self timing (internal timing)".
[MODE] button, press the [SET] button five times. Self timing When self timing is selected in , set the
"rSt.no" will appear. level threshold of the timing input.
2 Press the top/bottom Arrow buttons to select "rSt.YES".
Self timing
When "Std" is selected in , select the timing to fix the
criterion value after the value rises above (or falls below) the
3 Press the [MODE] button. delay type self timing level: "When the setting time is elapsed (delay
"rSt.End" will appear. timer)" or "After the display value is stabilized (static hold)".
Initialization is completed. User specified Set the delay time when "When the setting time is
O Default value list delay time elapsed (delay timer)" is selected in .
Default values of function settings Static hold delay Set the reference of stability criterion when "After the
Setting item Initial value stability criterion display value is stabilized (static hold)" is selected in .
Detection mode Std Static hold delay Enter a desired number when USEr (user
Hold update method tim stability width specification) is selected in .
Set the calculation mode when an expansion unit(s) is added.
Response time 100 (400)*1 Calculation
*The calculation mode will appear only when
Timing type t-in mode setting
an expansion unit(s) is added.
Self timing level 0.5000 Calculation Set the calculation method when "noCALc" is
method selected in .
Self timing delay type Stb.d
User specified delay time t=1000
9 GT2-70-M-E
O How to enter the function setting mode
Static hold delay stability criterion
Enter the function setting mode by the following procedure.
• In the main display, press the [MODE] button for at least two seconds. Only available when "Stb.d" is selected in [ Self timing delay type].
GT2-71
MODE
[MODE] button
Default
Detection mode
Static hold delay stability width
MODE
Only available when "USEr" is selected in [ Static hold delay stability criterion].
MODE
Standard
MODE
Regular update * Displayed only when two or more expansion units are connected.
Calculation method
Response time Only available when an expansion unit is connected.
An item other than "noCALc" is selected for [ Calculation mode].
MODE
GT2-70-M-E 10
No. Item Description <<When using a model other than GT2-71MCN/MCP (analog output type)>>
Limit output LL With the reference position being 0, set the Special output setting
side criterion position where the limit output extension side
position setting turns on.
When using GT2-71MCN/MCP (analog output type)
No. Item Description
Analog range Set the analog output range to "dEFALt (head Not used
setting stroke)" or "FrEE (free range)".
Free range Set the Hi side for the free range setting 5-output
settings (Hi side) when "FrEE" is selected in 16. Limit output
Free range Set the Lo side for the free range setting Limit output user setting
settings (Lo side) when "FrEE" is selected in 16.
All GO
O How to enter the basic setting mode
Enter the basic setting mode by the following procedure. All limit output
• In the main display, press the [MODE] button and the [SET] button
at the same time for at least two seconds.
The items that can be selected (displayed) are different
Reference
GT2-71 depending on the settings in " Calculation mode". (When
[SET] button the expansion unit is not added, the items that can be
selected (displayed) are the same as for "noCALc".
[MODE] button Special output
Calculation mode setting *1 *1
O O O O O -
Main screen O O*2 O O O*3 -
O O - - O O
Measurement direction change *1 This can be set only on the main unit that an expansion
Only available when a value other than "CAL.noH" is selected in [ Calculation mode]. unit is added.
*2 On the expansion unit, this can be set only when "C5.rEF
(Reference difference) is selected in "A2. Calculation Mode".
*3 This can be set only when "C5.rEF (Reference
difference)" is selected in "A2. Calculation method".
MODE
Multiplier
Only available when a value other than "CAL.noH" is selected in [ Calculation mode]. Reference
position set
Output mode
Setting value
input screen
MODE
N.C.
Hysteresis
Setting value
input screen
MODE
<<When using GT2-71MCN/MCP (analog output type)>>
Setting value
Analog range setting
input screen
MODE
Free range settings
Separate input
Free range settings (Hi)
Concurrent input Only available when "FrEE" is selected in " Analog range setting".
MODE
Setting value
input screen
11 GT2-70-M-E
Free range settings (Lo) Jam detection function
Only available when "FrEE" is selected in " Analog range setting". Not available to set on the main unit that selects "CAL.noH" in [ Calculation mode], and
the main unit and expansion unit that selects values other than "t-in" in [ Timing type].
MODE
MODE
Setting value
input screen
OFF
MODE
Main screen
NO
MODE
MODE
Capture the
MODE
detection value
OFF *Target value for the first point is the preset value.
ECO All
MODE
Setting value
input screen
GT2-70-M-E 12
2nd point detection/capture GT2-71D (pulse output type)
Q Names of parts of the amplifier
Advanced setting switches
Blink alternately
Capture the
detection value Input indicator
Pulse delivery indicator
Power/alarm indicator
13 GT2-70-M-E
O Minimum phase difference
Set the minimum phase difference of phase A and phase B (phase
A and phase B ).
Phase A
Phase B
ON
Phase A (Black wire)
OFF
ON
Phase B (White wire)
OFF
ON
Phase A (Black wire)
OFF
ON
Phase B (White wire)
OFF
ON
Phase A (Black wire)
OFF
ON
Phase B (White wire)
OFF
ON
Phase A (Black wire)
OFF
ON
Phase B (White wire)
OFF
Current position ON
request input OFF
Phase A ON
(Black line) OFF
Phase B ON
(White line) OFF
Phase Z ON
(Orange line) OFF
(1) (2) (3)
(1) When the automatic current position request input (pink wire) is
turned off, the pulse of the spindle is output according to the
amount of movement.
(2) When the automatic current position request input (pink wire) is
turned on, all pulse outputs are turned off.
(3) When the automatic current position request input (pink wire) is
turned from on to off, the number of pulses from the home to the
current position is output.
GT2-70-M-E 14
Specifications
Q Sensor head
Pencil type (short type)
Model GT2-S1 GT2-S5
Detection system Differential transformer
Measuring range*1 1 mm 5 mm
Operation range*1 2 mm 7 mm
Resolution 0.1 μm
Indication accuracy*2, *4 1 μm (P-P)
When installed facing down 1.12 N 1.0 N
Measuring
When installed sideways 1.1 N 0.95 N
force*3
When installed facing up 1.08 N 0.9 N
Sampling interval 1ms
Mechanical response*4 40 Hz 20 Hz
Operation indicator 2-color LED (red, green)
Enclosure rating*5 IP67G (JIS) and IP67 (IEC)
Surrounding air temperature -10 to +55°C (No freezing)
Environmental
resistance Relative humidity 10 to 85%RH (No condensation)
Vibration resistance 10 to 55 Hz, Compound amplitude 1.5 mm, 2 hours each in X, Y, and Z axis
Shock resistance 1000 m/s2 (IEC60068-2-27)
Main unit Main unit cover: SUS440C (GT2-S1), SUS430F (GT2-S5)
Cable between the sensor head and relay connector: PUR, Relay connector: PPSU
Material Dust boot NBR
Contact*6 SUS304, tungsten carbide
Head cable Sold separately (connected to relay connector)
Weight (excluding cable)*7 Approx. 30 g Approx. 40 g
*1 The measuring range indicates the range over which the measured value is displayed. The operation range indicates the range over which the spindle can actually move.
*2 For the GT2-S1, the indication accuracy is 1 μm for an arbitrary width of 0.1 mm within the area of measuring range center ± 0.15 mm and is 2 μm over this whole area.
For the GT2-S5, the indication accuracy is 1 μm for an arbitrary width of 0.2 mm within the area of measuring range center ± 0.3 mm and is 2 μm over this whole area.
Over the whole measuring range, the indication accuracy is linearity ± 0.15% of F.S. (F.S. is 1 mm for the GT2-S1 and 5 mm for the GT2-S5.)
*3 Typical value in the vicinity of the measured center value. Note that the measuring force varies depending on the installation status of the dust boot.
*4 When the surrounding temperature is 20°C.
*5 When an M8 oil-resistant cable (GT2-CHP2M/CHP5M/CHP10M) is used for the sensor head cable.
*6 The contact is a separately sold option.
*7 Including the relay connector.
Note: Cannot be used with amplifier units purchased before April 15th, 2014.
Table 1. Relationship between spindle position and measuring force grouped according to used air pressure.
GT2-PA12K/PA12 GT2-PA12KL/PA12L
Measuring force (N) Measuring force (N)
1.7 0.55
0.50
Applied pressure (MPa) Applied pressure (MPa)
0.45
0.26 MPa 0.07 MPa
1.2 0.40
0.25 MPa 0.06 MPa
0.30
0.7 0.25
0 1 2 3 4 5 6 7 8 9 10 11 12 Spindle position (mm) 0 1 2 3 4 5 6 7 8 9 10 11 12 Spindle position (mm)
Spindle extended Spindle retracted Spindle extended Spindle retracted
(When installing side mounting, the measuring force is -0.05 N. When installing upward mounting, the measuring force is -0.1 N.)
15 GT2-70-M-E
O Box type
Model GT2-H12K GT2-H12KL GT2-H12KF
GT2-H12KLF GT2-H12 GT2-H12L GT2-H12F GT2-H12LF GT2-H32 GT2-H32L GT2-H50
Detection system Scale shot system II Absolute type (without tracking error)
Measuring range 12 mm 32 mm 50 mm
Resolution 0.1 µm 0.5 µm
Indication accuracy *1 1 µm (P-P) 2 µm (P-P) 3 µm (P-P) 3.5 µm (P-P)
When installed facing down 1.0 N 0.4 N 1.0 N 0.4 N 1.0 N 0.4 N 1.0 N 0.4 N 2.1 N 1.2 N 3.2 N
Measuring force *2 When installed sideways 0.9 N 0.3 N 0.9 N 0.3 N 0.9 N 0.3 N 0.9 N 0.3 N 1.8 N 0.9 N 2.8 N
When installed facing up 0.8 N 0.2 N 0.8 N 0.2 N 0.8 N 0.2 N 0.8 N 0.2 N 1.5 N 0.6 N 2.4 N
Sampling interval 1 ms
Mechanical response *1 10 Hz 4 Hz 10 Hz 4 Hz 10 Hz 4 Hz 10 Hz 4 Hz 6 Hz 5 Hz 7 Hz
Operation indicator 2-color LED (red, green)
Enclosure rating IP67 - IP67 - IP67 - IP67 - IP67 - IP67
Surrounding air temperature -10 to +55°C (No freezing)
Environmental Relative humidity 35 to 85% RH (No condensation)
resistance
Vibration resistance 10 to 55 Hz, Compound amplitude 1.5 mm, 2 hours each in X, Y, and Z axis
Shock resistance 1000 m/s2 (IEC60068-2-27)
Main unit Main unit cover: zinc die-cast, Indicator: polyarylate (PAR)
Material Dust boot NBR - NBR - NBR - NBR - NBR - NBR
Contact point *3 SUS304, tungsten carbide SUS304, SUS440C
Cable Sold separately (connected to M8 connector)
Weight (excluding cable) Approx. 95 g Approx. 95 g Approx. 100 g Approx. 100 g Approx. 95 g Approx. 95 g Approx. 100 g Approx. 100 g Approx. 270 g Approx. 320 g
*1 When the surrounding temperature is 20°C. Entire measuring range. *3 The contact is a separately sold option.
*2 This is a typical value at the center of the measuring range. The measuring force varies depending
on the mounted condition of the dust boot.
Q Amplifier (GT2-71(C)N/71(C)P/72(C)N/72(C)P/75N/75P/76N/76P/71MCN/71MCP)
Mount type *1 DIN rail mount Panel mount DIN rail mount
Type
Main unit/Expansion unit *2 Main unit Expansion unit Main unit Expansion unit Main unit
NPN output GT2-71(C)N GT2-72(C)N GT2-75N GT2-76N GT2-71MCN
Model
PNP output GT2-71(C)P GT2-72(C)P GT2-75P GT2-76P GT2-71MCP
Number of units that can be added *2 Up to 14 expansion units for 1 main unit
Supply voltage *2 10 to 30 VDC, including 10% ripple (P-P) Class 2 20 to 30 VDC, including 10% ripple (P-P) Class 2
Display range -199.9999 to 199.9999
Display resolution 0.1 µm
Normal 2200 mW max. (73.3 mA max. at 30 V) 2700 mW max. (90 mA max. at 30 V)
Current consumption Power saving (eco half) 1800 mW max. (60.0 mA max. at 30 V) 2300 mW max. (76.7 mA max. at 30 V)
Power saving (eco) 1700 mW max. (56.7 mA max. at 30 V) 2200 mW max. (73.3 mA max. at 30 V)
hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1000 ms
Response time
(hsp (12ms), 20ms, 40ms, 400ms, 2000ms, 4000ms when using GT2-P***/PA*** with a sensor head)
Control output NPN output NPN open collector 40 V 50 mA max. Residual voltage: 1 V max.*2
(HH/HIGH/GO/LOW/LL) *3 PNP output PNP open collector 30 V 50 mA max. Residual voltage: 1 V max.*2
Timing input Input time: 2 ms min.
Preset input
Control input
Reset input Input time: 20 ms min.
Bank input
Output range ––––––––––––––– 4 to 20 mA, Maximum load resistance 350
Analog output (Can be set anywhere within the analog output range)
Response time ––––––––––––––– Specified response time + 1 ms
Surrounding air temperature*2 -10 to +50°C (No freezing) *2
Environmental resistance Relative humidity 35 to 85%RH (No condensation)
Vibration 10 to 55 Hz, Horizontal amplitude: 1.5 mm, 2 hours each in X, Y, and Z axis
Material Main unit cover/Front cover: Polycarbonate (PC), Keytop: Polyacetal (POM), Front sheet: Polyethylene terephthalate (PET), Cable: Polyvinyl chloride (PVC)
GT2-71N/71P/72N/72P Approx. 140 g (Including a power cable)
Weight GT2-75N/75P/76N/76P Approx. 140 g (Including a panel mounting bracket, front protective cover, power cable)
GT2-71(M)CN/71(M)CP/72CN/72CP Approx. 70 g
*1 When using the DIN rail mount type unit, be sure to mount it to a DIN rail (fixed to a metal ◆ When connecting 9 to 15 units including the main unit
plate). Use the end unit (OP-26751) when connecting expansion units. • Supply voltage: 20 to 30 VDC
*2 When adding an expansion unit(s), the following restrictions apply depending on the • Control output current: 10 mA max. (including the output current of the DL-RB1A)
number of connected units. • Residual voltage: 1.5 V max.
◆ When connecting 2 to 8 units including the main unit • (GT2-71MCN/71MCP only) Surrounding air temperature: -10 to +45°C
• Supply voltage: 20 to 30 VDC *3 HH and LL are not available for GT2-71MCN/71MCP.
• Control output current: 20 mA max.
• (GT2-71MCN/71MCP only) Surrounding air temperature: -10 to +45°C
Q Amplifier (GT2-71D)
Mount type DIN rail mount
Type
Main unit/Expansion unit Main unit
Model GT2-71D
Number of units that can be added Expansion not possible
Supply voltage 10 to 30 VDC, including 10% ripple (P-P) Class 2
Indicators Power indicator (green), alarm indicator (red), pulse output indicator (green), input indicator (green)
Pulse resolution Select from 0.1 µm, 0.5 µm, 1 µm, 10 µm
Power consumption 1600 mW or less (53.3 mA or less with 30 V)
Minimum phase difference Select from 0.5 µs, 2.5 µs, 5 µs, 25 µs
Control input (homing) No-voltage input (with contact, without contact), input time 20 ms or more
Output signal Phase A/B/Z 90° phase difference, differential square-wave (EIA-422 compliant), x 4
Output signal level +5 V
Surrounding air temperature -10 to +50°C (No freezing)
Environmental
Relative humidity 35 to 85%RH (No condensation)
resistance
Vibration 10 to 55 Hz, Horizontal amplitude: 1.5 mm, 2 hours each in X, Y, and Z axis
Material Main unit cover Polycarbonate (PC)
Weight Approx. 110 g (including a power cable)
GT2-70-M-E 16
Circuit diagram Q External input circuit diagram
GT2-71D
Q I/O circuit diagram DC5V
GT2-71(M)(C)N/72(C)N/75N/76N
Brown *1
DC10-30V*3 Pink
Black (HI output)
protection circuit Load DC5-40V
circuit
Overcurrent
Main
White (LO output)
Main circuit
Load DC5-40V
Blue
Gray (GO output)
Load DC5-40V
Orange (HH output)*2
Load DC5-40V (Short circuit current: 1 mA max.)
Green (LL output)*2
Load DC5-40V
Q Recommended input device
1
Blue *
0V
Pink, Violet, Pink/Violet, Yellow, Red *4
Input circuit External input Line receiver AM26LS32 or equivalent
*1 Brown and blue are available for main units (GT2-71(M)(C)N/75N) only.
Not available for expansion units (GT2-72N/76N).
The expansion unit of the connector type (GT2-72CN) is not connected.
*2 In the analog type (GT2-71MCN), the orange and green lines are analog output lines.
Refer to the analog output circuit diagram for details. 390Ω
*3 When an expansion unit is connected or for the analog type (GT2-71MCN), the voltage is DC20-30V.
*4 Refer to external input circuit diagram for details about external input.
GT2-71(M)(C)P/72(C)P/75P/76P
Brown *1
DC10-30V*3
Black (HI output) WARRANTIES AND DISCLAIMERS
protection circuit
Load
Overcurrent
Gray (GO output) Load (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1)
Load year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were
Orange (HH output)*2
used merely to illustrate the general type and quality of the Products and not to represent that the Products
Load
Green (LL output)*2 would necessarily conform to said models or samples. Any Products found to be defective must be shipped to
Blue *1 Load KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon
0V
Pink, Violet, Pink/Violet, Yellow, Red *4 examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace
Input circuit External input at no charge any Products found to be defective. This warranty does not apply to any defects resulting from
*1 Brown and blue are available for main units (GT2-71(M)(C)P/75P) only. any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair,
Not available for expansion units (GT2-72P/76P).
The expansion unit of the connector type (GT2-72CP) is not connected. unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat,
*2 In the analog type (GT2-71MCP), the orange and green lines are analog output lines. coldness, moisture, vibration or outdoors air. Components which wear are not warranted.
Refer to the analog output circuit diagram for details. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions,
*3 When an expansion unit is connected or for the analog type (GT2-71MCP), the voltage is DC20-30V.
*4 Refer to external input circuit diagram for details about external input. and it is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use.
KEYENCE will not be responsible for any damages that may result from the use of the Products.
Q Analog output circuit diagram (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be used
internally in humans, for human transportation, as safety devices or fail-safe systems, unless
GT2-71MCN/71MCP their written specifications state otherwise. Should any Products/Samples be used in such a
manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer
Orange will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage
Main circuit
Analog output (4 to 20 mA) whatsoever arising out of any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO
OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY
WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
Green*
0V FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED.
* The green line is internally common with the blue line. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON
OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
Q External input circuit diagram CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING
GT2-71(M)(C)N/72(C)N/75N/76N FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR
INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF
Pink: Preset input
DC5V
Violet: Bank A input PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY
Pink/Violet: Timing input MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE
Yellow: Bank B input PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A
Red: Reset input
POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In
some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply.
circuit
Main
Blue*1
BUYER'S TRANSFER OBLIGATIONS:
(Short circuit current: 1 mA max.) If the Products/Samples purchased by Buyer are to be resold or delivered
*1 Blue is available for main units (GT2-71(M)(C)N/75N) only. to a third party, Buyer must provide such third party with a copy of this
Not available for expansion units (GT2-72(C)N/76N). document, all specifications, manuals, catalogs, leaflets and written
GT2-71(M)(C)P/72(C)P/75P/76P information provided to Buyer pertaining to the Products/Samples.
DC10-30V E 1101-3
Brown*1
Main circuit
White: B phase
33W Black, White, Orange
Orange: Z phase
33W _
Violet, Gray, Green Violet:_A phase
Gray: B_phase
Blue Green: Z phase
Pink* Pink: Input
Input circuit
* Refer to external input circuit diagram for details about external input.
17 GT2-70-M-E
GT2-70-M-E 18
19 GT2-70-M-E