You are on page 1of 1

Notes:-

DETAILS OF BEAMS AT SLAB LEVEL- DETAILS OF LINTELS Ld OR 450mm [General]


(WHICH EVER IS MORE) [1] All dimensions are in m.m. unless otherwise mentioned.
Ld OR 0.25 x L1 Ld OR 0.25 x L1 Ld OR 0.25 x L2 TOP BARS [2] Only figured dimensions are to be followed neither the bars shall be counted nor the
Top bars+2extra bar

SLAB
(Which ever is more) (Which ever is more) (Which ever is more) dimensions scaled from the drg.
Ast1 (Thro.) Ast2(Extra) Ast2(Extra) Ast1 (Thro.) SLAB LVL. 100 of same dia as top bar TOP BARS [3] Any discrepancy in the drgs. shall be brought to the notice of the architect / consultant and
Ast2(Extra)Ast1 (Thro.) clarification obtained in writing prior to execution of work.

D
Ld+10Ø
[4] High yield strength deformed bars of yield stress 500 n/mm² (fe-500) which shall conform

Ld+10Ø
to IS 1786-1985 shall be used as reinforcement
Stirrups [5] Clear cover of main reinf. shall be as follows. (a) Footing = 50 mm (b) Column=40mm

D
BOTTOM BARS WALL (c) Beam = 25 mm. (top & bottom) or dia of bar whichever is more (d) Slab = 20 mm
WALL BOTTOM BARS (f) waist slab = 25 mm
CLEAR OPENING [6] End/side cover of all reinforcement in beams & slab = 25 mm. or dia of bar whichever is more
Asb1 (Thro.) Asb2(Extra) Asb2(Extra)Asb1 (Thro.) [7] The cover block of cement mortar shall be used to ensure the reqd. cover of reinforcement
0.1xL1 0.15xL1 0.15xL2 [8] Development length ( Ld ) for different dia meter of bars for conc. mix of grade M - 25 shall
COL.
L - SEC. OF R.C.C. LINTEL (BxD) be = 49 x dia of bar
Stirrups in end zone Stirrups in middle zone Stirrups in end zone Stirrups in end zone [9] Conc. mix for r.c.c. work shall be of grade M - 25 conforming to I.S. 456 - 2000.
END COL. (FOR LINTEL REFER TABLE-5) TYP. DETAIL OF LINTEL FIXING AT COLUMN [10] Necessary fixture for electrical, plumbing, etc. shall be provided in slab, beams before
2D Middle zone 2D 2D
INTERMEDIATE COLUMN (for top & bottom bars of different span refer table -5 ) execution as per relevant drgs.
End zone End zone [11] The structure has been designed for seismic zone - II
L1 L2
TABLE-5, DETAIL OF LINTELS FOR DOOR / WINDOW OPENING [12] The structure has been designed for Ground G+3= 4 storey
TYP. REINFORCEMENT DETAILS IN THE BEAMS SPANNING BETWEEN SUPPORT TO SUPPORT [13] P.C.C.(1:4:8) shall be provided.
FOR DETAILS REFER TABLE [3] BELOW [14] All plain concrete & rcc shall be strictly in accordance with the provision of IS - 456:2000.
FOR 200 TH WALL FOR 150 TH WALL [15] Cutting,bending,fixing & placing of bars shall be in accordance with IS - 2502:1968,
Note :- at the junction of two diff. number of beams the heigher reinforcement at the support shall be addopted. DOOR/ Lintel CrossLongitudinal Reinforcememnt Lintel Cross Longitudinal Reinforcememnt
IS - 5525:1969 & IS - 456:2000
Stirrups DOOR/

S.N.
Section Stirrups [Foundation]
WINDOW WINDOW Section
TABLE -3, DETAILS OF BEAMS AT SLAB LVL OPENING (L) ( B X D ) BOTTAM
BARS
TOP BARS '2L' STPS
OPENING (L) ( B X D )
BOTTAM
BARS
TOP BARS '2L' STPS [1] The layout of building shall be given from the arch. drg.
[2] The design data for foundation has been taken from soil test report ( SBC = 23.0 t/sqm at 1.00 m depth)
1 >750≤1000 200 X100 2 # 10 2#8 #8@175 >750≤1000 150 X100 2 # 10 #8@175 [3] Earth below foundation shall be properly rammed & consolidated before laying lean concrete.
BEAM NO.

2#8
BEAM LONGITUDINAL REINFORCEMENT STIRRUPS >1000≤1500 200 X100 3 # 10 2#8 #8@175 >1000≤1500 150 X100 2 # 10 #8@175 [Columns]
SIDE FACE 2 2#8
SR. NO.

SIZE TOP FACE REINFORCEMENTBOTTOM FACE REINFORCEMENT END MIDDLE REINF. 3 >1500≤2000 200 X200 2 # 12+1#10 2 # 8 #8@150 >1500≤2000 150 X200 2 # 10+1#8 2#8 #8@150 [1] Ties in portion of col. & beam junction shall be same as end zone.
(ON EACH SIDE FACE) [2] The spacing of stirrups at overlaps should not exceed 100 mm. c/c
W D Ast1 Ast2 Asb1 Asb2 ZONE ZONE 4 >2000≤ 2500 200 X200 2 # 12+2#10 2 # 8 #8@125 >2000≤2500 150 X200 3 # 10 2#8 #8@125 [3] Over laps are allowed only at middle zone of the columns.
(Thro. at Top) (Extra at support) (Thro. at Bottom) (Extra at middle) '2L'STPS '2L'STPS [4] Not more than 50 % of bars shall be lapped at a section and laps shall be staggered.
mm mm [5] Ties in portion of col. below tie beam shall be same as end zone .
1 B1 230 300 2#16Ø - 2#16Ø - #8@100c/c #8@150c/c - STANDARD DETAIL OF R.C.C. BAND TO BE TYPICAL DETAIL OF PROVIDING VERTICAL [6 Vertical bars of rcc column at top slab shall be extended upto top of beam & bent into beam
2 B2 230 425 2#16Ø 1#16Ø 2#16Ø 1#12Ø #8@100c/c #8@200c/c - PROVIDED AT SILL LVL. & LINTEL LVL. FOR STEEL BARS AROUND DOORS / WINDOWS by development length.
3 B3 230 425 3#16Ø - 3#16Ø - #8@100c/c #8@200c/c - 200 MM. & 150 MM TH. AAC BLOCK WALL [Beams]
300
4 B4 230 300 2#16Ø - 2#16Ø - #8@100c/c #8@150c/c - 2#10 300 [1] For location of beams refer slab plan.
Lintel [2] The spacing of stirrups at overlaps should not exceed 100 mm. c/c
5 B5 230 425 2#16Ø - 2#16Ø - #8@100c/c #8@200c/c - Lintel

100
#8@200 [3] Where two layers of reinf. bars are to be provided, spacer bar are to be provided at spacing of
6 B6 230 425 3#16Ø 2#16Ø 3#16Ø 2#12Ø #8@100c/c #8@200c/c - Jamb reinf.
2#10 1000 mm. max. and the dia of the spacer bar shall be higher of dia of longitudinal bars or 25 mm.
7 B7 230 425 2#16Ø - 2#16Ø - #8@100c/c #8@200c/c - 2#10 Masonary Jamb reinf. [4] max. 3 nos. of bars shall be provided in a layer of 250 mm wide beam.
- 150 Conc. [5] At the junction of two diff. number of beams the higher reinf. at the support shall be adopted.
8 B8 230 425 3#16Ø 2#16Ø 3#16Ø 2#16Ø #8@100c/c #8@200c/c [6] Over lap in top bars shall be near mid span & in bottom bars shall be near support or at support.
9 B9 230 425 2#12Ø - 2#12Ø - #8@100c/c #8@200c/c - DETAIL OF RCC BAND (150X100) Masonary 1 1
Ø8@150 [7] The depth of beam monolithic with slab as specified in schedule shall be inclusive of slab
2#10 Conc. 1 1
10 B10 230 425 2#16Ø 1#16Ø 2#16Ø 1#12Ø #8@100c/c #8@200c/c - thickness unless otherwise specified.
- [8] Hooks in stirrups of beams shall be bent inside at 135° & length of hooks shall be
11 B11 230 425 2#16Ø 1#16Ø 2#16Ø 1#12Ø #8@100c/c #8@200c/c

100
#8@200 100 10 x dia of bar of stirrups
12 B12 230 425 2#16Ø 2#16Ø 2#16Ø 1#16Ø #8@100c/c #8@200c/c -
- 300 [Slabs]
13 B13 230 425 2#16Ø - 2#16Ø - #8@100c/c #8@200c/c 2#10 [1] For slab reinforcement refer table-4 (detail of slab reinforcement).
- Plinth Beam
14 B14 230 425 2#16Ø 1#16Ø 2#16Ø 1#12Ø #8@100c/c #8@200c/c 200 [2] Extra bars shall be provided at top face as shown in typ. section of slab.
15 B15 230 425 2#16Ø 3#16Ø 3#16Ø 2#12Ø #8@100c/c #8@200c/c - SECTIONAL ELEVATION SECTIONAL ELEVATIONWINDOW / DOOR [3] The cross reinf./temp. reinf. below top reinf of slab .i.e.#8@300c/c is to be provided just
DETAIL OF RCC BAND (200X100) SECTION AT 1-1 below the main top steel as shown in typ. sec.of slab.
OF DOOR OF WINDOW [4] The first main bar of slab shall be placed at 80 mm. or half the spacing specified
whichever is less from the face of support

DETAIL OF STAIR FLIGHTS Nos. of tread, riser & stair width as per arch dwg. [Masonary work]
[1] All walls shall be AAC block walls.
TYPICAL SECTIONAL DETAILS OF SLAB
(t = THICKNESS

0.15 x L1 0.3 x L1 0.3 x L2 Ld OR 0.25 x L2 #8@200


OF SLAB)

#8@300(Distribution reinf.) (WHICH EVER IS MORE) 9


Extra top bar Extra top bar Slab Lvl. (Both ways) 300 00
2#16(Thro.) 2#16(Extra) 2#16(Extra)2#16(Thro.) (Bo#8@2
t

th w 00 Bri
ck Revision Notes -

300
Bars along longer span (Cross bars) BEAM 450 CB1 ays step
0.15xL1 0.15xL1 0.15xL2 Bars along longer span (Cross bars) Beam rear side Slab reinf. ) ove
Bars along shorter span (Main bars) #8@200 rw
Bars along shorter span (Main bars) #12@150
BEAM Beam aist
L1 L2 3#16(Thro.) Beam at Slab lvl. #12 slab
3#16(Thro.) for detail refer plan @1
TYPICAL CROSS SECTION OF SLAB ALONG SHORTER SPAN OF SLAB #8@100 50 #8@ 900 Rev Purpose of Issue Date Authorized
(Bo 2
Refer table - 4 th w 00
PROJECT -

th.
ays #8@200
NOTE : AT THE JUNCTION OF TWO DIFF. NUMBER OF SLAB THE HEIGHER REINFORCEMENT AT TOP FACE AT CONTINIOUS EDGE SHALL BE ADDOPTED. #8@ )

150
L - SEC. OF CANTILEVER BEAM CB1 200
300
(Both ways) Landing Lvl.
Table-4, Details of slab reinforcement (230X300) 300 MAHOBA,
PROPOSED DISTRICT JAIL AT
REINFORCEMENT REINF. DETAIL OF 2nd FLIGHT OF STAIR UTTAR PRADESH.
Slab No.

#8@200 #12@150
Sr. No.

Slab Parallel to Shorter Span (Main bars) Parallel to Longer Span (Cross bars) (Flight from Landing lvl. to Slab lvl.)
Depth Beam at landing lvl.
At Bottom face At Top face At Bottom face At Top face
(mm) (Mid Span) (Extra bars at support) (Mid Span) (Extra bars at support) 2000 for detail refer plan BUILDING -
1 S1 125 #8@200c/c #8@200c/c #8@200c/c #8@200c/c
3#16(Thro) 3#16(Thro)
900 00
#8@200
(Both ways) Landing Lvl.
TYPE-II RESIDENCE (G+3)
2 S2 125 #8@175c/c #8@175c/c #8@200c/c #8@200c/c 3 300
00 ys)

300
3 S3 125 #8@175c/c #8@175c/c #8@175c/c #8@175c/c 900 @ 2 a
8
# th w
4 S4 125 #8@150c/c #8@150c/c #8@175c/c #8@175c/c 2#12(Thro) slab (Bo DRG. TITLE -
Beam aist #8@200
Note - for reinforcement in cantiliver balcony/ projections refer typ. detail of slab projection rw
(t = Thickness of slab)

2#12(Thro)
ove #12@150 DETAIL OF REINF. OF BEAMS, LINTEL, SLAB &
1.5xL #8@100 step Beam at landing lvl.
ck 50
Bri 1 for detail refer plan STAIR FLIGHTS
Extra top bars(*) Distribution reinf. Detail 'A' # 12@
(#8@300c/c)
(230X300) 200ays)

150
#8@th w
200
t

th.
#8@200 ( B
P. Lvl. (Both ways) #8@ NORTH - SCALE - DATE - REV.-
SLAB REINF.
BEAM Alt. bottom bars of slab 300 NTS JUNE 23 R0
L REINF. DETAIL OF 1st FLIGHT OF STAIR
TYPICAL DETAILS OF SLAB PROJECTION (without beam) #12@150 #8@200 (Flight from P. lvl. to Landing lvl.)
NOTE - IF BALCONY/SLAB PROJECTIONS [L] Tie Beam
DRG NO. -
(1)- If Balcony/slab projections [L] = 600 - 750 mm, Extra top bars (*) #8Ø Bars @ 150 c/c for detail refer plan
(2)- If Balcony/slab projections [L] = 900 -1050 mm, Extra top bars(*) #8Ø Bars @ 125 c/c MATRIX/DJ/MHB/TYPE-II/STR/ ST-02
TYP. DETAILS DETAILS OF R.C.C. BAND AT SLAB LVL
IMPLEMENTING AGENCY -

These bar are to be anchored

These bar are to be anchored


in to main beam / col. / slab

in to main beam / col. / slab


SECONDARY BEAM
3 extra stirrups top face reinf. UTTAR PRADESH PUBLIC WORKS
each side of main beam
DEPARTMENT GOVT. OF UTTAR PRADESH
Slab Lvl. Slab Lvl.
Ld 2#12 3#12
450 450
10Ø

DESIGN ARCHITECT -
D

(Ld)

300

300
Stirrups #8@150 #8@150

0.1x L1 Column 2#12 3#12


ARCH-EN DESIGN
TYP. DETAILS OF HOOKS 2#12 hanger bars SPAN (L1) TYPICAL DETAILS OF REINFORCEMENT
bottom face reinf.
150 200 Delhi Office: B-1/37, Hauz Khas, New Delhi-16.
MAIN BEAM of main beam Ph.: 011-45188222, 0522-4088222
(Ø = Dia of bar) AT THE JUNCTION OF TWO UNEQUAL
TYP.DETAILS OF HANGER BARS BELOW SECONDARYTYPICAL DETAILS OF BEAM AT DEPTH OF BEAMS. TYP. DETAIL OF RCC BAND (150X300) TYP. DETAIL OF RCC BAND (200X300) Lko Office: 4/5, Vishal Khand, Gomtinagar, Lucknow.
BEAM RESTING ON MAIN BEAM END RESTING ON THE ANOTHER AROUND CUB BOARD / SHAFT / FINS AROUND CUB BOARD / SHAFT / FINS www.aed.co.in / info.lucknow@aed.co.in
BEAM OF HIGHER BEAM TO SUPPORT 150 TH. BRICK WORK TO SUPPORT 200 TH. BRICK WORK
EPC ARCHITECT CONSULTANT -
Ld OR 0.25 x L1
2 extra stirrup at (which ever is more) PRO DESIGNERS
Slope 1:6 2 extra stirrup at Column in plan the location of bend. extend thro. & extra (Thro. bar) 2#12Ø(thro.) 1, Shiv Vihar, Faridi Nagar, Indira Nagar, Lucknow
each bend. BAR TO BE PROVIDED bar of rear beam Extra bar
CONTINUOUS #8@200c/c Uttar Pradesh, 226015
125

t
B2

Email :
HB1 beam rear side 2#12Ø(thro.)
B1

2#12(Thro.) 230 EPC CONTRACTOR -


TYP.DETAILS OF SUNSHADES/CHAJJAS beam bottom reinf. DETAIL OF BEAM HB1 (230Xt)
BARS TO BE EMBEDED
SLOPE 1:6 t= thickness of slab
Global Zone Sanitory Infrastructure Pvt. Ltd.
IN COLUMNS (TYP.) #8@200 1/6, Vikrant Khand,
LINTEL/
TYPICAL DETAILS OF REINF. TYPICAL DETAILS OF REINFORCEMENT INTYPICAL DETAILS OF REINFORCEMENT DETAIL 'B' (230X125)
BEAM Gomti Nagar,
100

AT THE JUNCTION OF TWO BEAM AT THE JUNCTION OF COLUMNS BEAM AT THE JUNCTION OF TWO BEAMS OF
BEAMS OF UNEQUAL DEPTH. HAVING UNEQUAL WIDTH AT THE
150
#8@150
Lucknow - 222601
EQUAL DEPTH.
DIFFERENT FACE OF COLUMNS 'U' shape bar
EPC STRUCTURAL CONSULTANT -
200 450-600MM.
SUNSHADES/CHAJJAS MATRIX STRUCTURES
(PROJECTION UPTO 451-600 MM.) (STRUCTURAL ENGINEERING CONSULTANT)
138, Vibhav Khand, Gomtinagar, Lucknow, Mobile - 9335903324