You are on page 1of 14

RR2 RESIDENCE DRAWING INDEX

-
RR2

2022.05.27 - Core & Shell Pricing Set


1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514 E
RESIDENCE
E 1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
E
E
§ OWNER

SHEET NUMBER SHEET NAME ÉÉ RR ORCHARD HOLDINGS LLC


1347 HOLLOW RD, CLINTON CORNERS, NY 12514

TITLE SHEET
G-001 TITLE SHEET •
ARCHITECT
GENERAL
G-002 GENERAL NOTES •
WORKSHOP/APD ARCHITECTURE DPC
STRUCTURAL 39 W 38th Street, 7th Fl, New York, NY 10018
T: (212) 273-9712 info@workshopapd.com
S-100 FOUNDATION PLAN •
S-101 FIRST FLOOR FRM PLAN •
S-102 SECOND FLR / ROOF FRM PLAN •
S-201 TYP. CONC. DETAILS • CONTRACTOR
S-202 TYP. WOOD DETAILS •
S-203 TYP. WOOD DETAILS • STONELEAF CONSTRUCTION
S-204 TYP. WOOD DETAILS • 4974 Route 22 Amenia, NY 12501
T: (845) 373-8020
S-205 TYP. WOOD DETAILS •
S-300 WALL ELEVATIONS •
S-301 WALL ELEVATIONS •
S-302 WALL ELEVATIONS • STRUCTURAL ENGINEER
S-303 SECTIONS & ELEVATIONS •
GRAND TOTAL: 14 MURRAY ENGINEERING
330 7th Avenue New York, NY 10001
T: (212) 741-1102

LANDSCAPE ARCHITECT
JAMES DOYLE DESIGN ASSOCIATES
125 Greenwich Avenue Greenwich, CT 06830
T: (203) 869-2900

SURVEYOR/ CIVIL ENG.


INSITE ENGINEERING, SURVEY & LANDSCAPE
ARCHITECTURE, P.C.
3 Garret Place, Carmel, New York 10512
T: (845) 225-9690

✗ ALL DESIGNS & SPECS ARE SUBJECT TO


VERIFICATION OF EXG. FIELD CONDITIONS

REVISIONS

NOT FOR CONSTRUCTION

SIGN & SEAL

ISSUES
01 2021.10.21 CORE AND SHELL PRICING SET
02 2022.04.25 UPDATED FLOOR PLANS
03 2022.05.02 INT. BUDGET ASSUMPTIONS
04 2022.05.27 PROGRESS SET
05 2022.06.10 PROGRESS SET
06 2022.06.17 PROGRESS SET

DRAWING INFO
CONSTRUCTION DOCUMENTS
DRAWN BY: Author
CHECKED BY: Checker
DATE: 06/08/19
SCALE:
PROJ. NO. Project Number

TITLE SHEET

G-001
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
RR2
STRUCTURAL NOTES FOUNDATIONS: CAST IN PLACE CONCRETE WOOD FRAMING:

GENERAL: 1. GENERAL CONTRACTOR IS TO REVIEW AND FOLLOW REQUIREMENTS OUTLINED IN THE GEOTECHNICAL 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE ACI BUILDING CODE, ACI 318-11, AND THE 1. ALL LUMBER WORK AND MATERIALS SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING
REPORT. NEW YORK STATE BUILDING CODE. DETAILS SHALL BE IN ACCORDANCE WITH ACI-315, LATEST EDITION.. SPECIFICATIONS AND THE CODES RULES AND REGULATIONS OF THE STATE OF NEW YORK,:
1. IT IS THE INTENTION OF THIS SET OF DESIGN DRAWINGS TO PROVIDE AND OUTLINE A STRUCTURAL SYSTEM THAT ALLOWS THE CONTRACTOR
TO ADEQUATELY BUDGET AND PLAN TO PRODUCE CONSTRUCTION SHOP DRAWINGS FOR THE FABRICATION AND ASSEMBLY OF THE 2. FOOTINGS ARE TO BEAR ON MIN. 4,000 PSF SUITABLE BEARING MATERIAL. 2. ALL CONCRETE FOR CAST IN PLACE WORK SHALL BE STONE CONCRETE WITH A MINIMUM 28 DAY a. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC).
BUILDING SYSTEM. IT IS EXPECTED THAT THE CONTRACTOR WILL PROVIDE ALL NECESSARY PROFESSIONAL EXPERTISE, INCLUDING A COMPRESSIVE STRENGTH OF 8000 PSI, UNLESS OTHERWISE NOTED.
LICENSED PROFESSIONAL ENGINEER, REQUIRED FOR THE REMAINING COORDINATION, DETAILING AND MISCELLANEOUS DESIGN NOT 3. NO FOOTINGS ARE TO BE CAST ON UNCONTROLLED FILL, SOIL, ORGANIC MATERIAL, FROZEN GROUND, b. NATIONAL FOREST PRODUCTS ASSOC. "DESIGN SPECIFICATIONS FOR STRESS GRADE LUMBER".

RESIDENCE
INCLUDED HEREIN. MUD, SOFT CLAYS OR OTHER OBJECTIONABLE OR UNAPPROVED MATERIALS. 3. ALL CONCRETE FOR SLABS ON GRADE SHALL BE STONE CONCRETE WITH A 28 DAY COMPRESSIVE
STRENGTH OF 5000 PSI. c. U.S. DEPT. OF COMMERCE STANDARD CS 253.
2. THE STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE BUILDING CODE, 2020 EDITION 4. ALL EXTERIOR CONSTRUCTION JOINTS IN FOUNDATION WALLS BELOW GRADE SHALL HAVE WATERSTOPS.
4. ALL SLABS ON GRADE ARE TO BE REINFORCED WITH 1 LAYER OF 6X6-W2.0XW2.0 WWF LOCATED 3/4" FROM d. AMERICAN PLYWOOD ASSOCIATION.
5. FOUNDATION WALLS ARE NOT DESIGNED AS FREE-STANDING WALLS. DO NOT PLACE ANY BACKFILL TOP OF FINISHED SLAB ELEVATION.
1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
3. ALL WORK SHALL COMPLY WITH THE NEW YORK STATE BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND REGULATIONS OF AGAINST WALLS UNLESS CELLAR AND FIRST FLOOR CONSTRUCTION HAS BEEN COMPLETED AND IN PLACE 2. LUMBER FOR ALL INTERIOR STRUCTURAL FRAMING, INCLUDING ROOF FRAMING, JOISTS, POSTS, STUDS,
AGENCIES HAVING JURISDICTION. A MINIMUM OF 7 DAYS. ANY AREA BACKFILLED FOR ACCESS MUST BE ADEQUATELY BRACED TO 5. NO ADMIXTURES SHALL BE ALLOWED WITHOUT PRIOR REVIEW AND ACCEPTANCE BY THE ENGINEER. SILLS, CAP PLATES, WOOD BEARING PLATES, AND BLOCKING, SHALL BE DOUGLAS FIR-LARCH (NORTH) NO.
WITHSTAND EARTH PRESSURE AND CONSTRUCTION LOADS. 1/NO. 2. ALL STRUCTURAL MEMBERS SHALL BE SURFACE DRY AND USED AT MAXIMUM 19% MOISTURE
4. ALL REFERENCED STANDARDS REFER TO THE EDITION IN FORCE AT THE TIME THESE PLANS AND SPECIFICATIONS ARE ISSUED FOR PERMIT. 6. ALL REQUIREMENTS FOR BATCHING, MIXING, FINISHING, CURING ETC. SHALL BE AS PER ACI 301. CONTENT WITH THE FOLLOWING MINIMUM BASE DESIGN VALUES: OWNER
6. SUB-BASE FOR SLABS ON GRADE TO BE 6" OF COMPACTED SAND OR GRAVEL WITH 15 MIL VAPOR BARRIER.
5. JOB SAFETY AND PROCEDURES FOR SAFE CONSTRUCTION ARE OF UTMOST IMPORTANCE, AND SHALL BE THE RESPONSIBILITY OF THE 7. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60. BASE DESIGN VALUES FOR VISUALLY GRADED DIMENSION LUMBER: RR ORCHARD HOLDINGS LLC
CONTRACTOR. 7. DOWELS FROM FOOTINGS INTO PIERS, BUTTRESSES AND WALLS ABOVE, SHALL BE THE SAME SIZE AND 1347 HOLLOW RD, CLINTON CORNERS, NY 12514
NUMBER AS VERTICAL REINFORCEMENTS IN PIERS, BUTTRESSES AND WALLS, AND SHALL BE EXTENDED 8. ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. BENDING: FB = 850 PSI
6. WORK NOT EXPRESSLY SHOWN ON SPECIFIC PARTS OF THE DRAWINGS OR SPECIFICATIONS, BUT REASONABLY IMPLIED BY SIMILAR WORK INTO FOOTINGS AND INTO PIERS, BUTTRESSES AND WALLS UNLESS OTHERWISE SHOWN. HORIZONTAL SHEAR: FV = 180 PSI
SHOWN, SHALL BE REPEATED. 9. ALL REINFORCEMENT SHALL BE SECURELY TIED IN PLACE AND ADEQUATELY SUPPORTED. ALL BARS COMP. PERPENDICULAR TO GRAIN: FC = 625 PSI
8. DROP BOTTOM OF WALLS AND PIERS TO TOP OF FOOTINGS, TO OBTAIN FULL EXTENT OF CONTACT, MARKED 'CONTINUOUS' (CONT.) SHALL BE LAPPED ACCORDING TO TABLES 3-4 UNLESS OTHERWISE COMP. PARALLEL TO GRAIN: FC = 1,400 PSI ARCHITECT
7. WORK THESE DRAWINGS WITH THE SPECIFICATIONS, THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, SITE DRAWINGS UNLESS OTHERWISE SHOWN. NOTED. IF REQUIRED, CONTRACTOR SHALL PROVIDE ADDITIONAL BARS OR STIRRUPS TO ADEQUATELY MODULUS OF ELASTICITY: E = 1,600,000 PSI
GEOTECHNICAL REPORT AND ALL OTHER RELATED DOCUMENTS. ONTRACTOR SHALL COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL SUPPORT ALL BARS.
DRAWINGS AND SHALL VERIFY LL DATA ON EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 9. HEAVY EQUIPMENT SHALL NOT BE PERMITTED CLOSER THAN 8 FEET FROM ANY FOUNDATION WALL. ALL VALUES SHALL BE ADJUSTED WITH APPROPRIATE ADJUSTMENT FACTORS PER NDS SUPPLEMENT.
WORKSHOP/APD ARCHITECTURE DPC
CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE SUPPORTS AND BRACING TO PROTECT WALLS 10. ALL REINFORCING BARS SHALL BE LAPPED AS DETAILED ON DRAWINGS AND NOTES. WHERE NOT ANY LUMBER SPECIES MAY BE USED, SUBJECT TO REVIEW AND ACCEPTANCE BY THE ENGINEER, IF THEY 39 W 38th Street, 7th Fl, New York, NY 10018
8. COORDINATE THESE DRAWINGS WITH THE MECHANICAL, ELECTRICAL, AND PLUMBING TO PROVIDE EQUIRED SLAB AND WALL OPENINGS. AGAINST LOADS FROM HEAVY EQUIPMENT OPERATION. SPECIFICALLY INDICATED ON DRAWINGS OR NOTES: LAP WALL TOP HORIZONTAL REINFORCEMENT AT MEET THE ABOVE MINIMUM REQUIREMENTS. T: (212) 273-9712 info@workshopapd.com
CONTRACTOR SHALL INCLUDE MISCELLANEOUS FRAMING AT THESE PENINGS IN SHOP DRAWINGS FOR REVIEW. CENTER OF SPAN. LAP WALL BOTTOM HORIZONTAL REINFORCEMENT AT SUPPORT. LAP INSIDE FACE
WALL VERTICAL REINFORCEMENT AT SUPPORT. LAP \OUTSIDE FACE VERTICAL WALL REINFORCEMENT AT 3. TJI SERIES:
9. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF WORK BETWEEN NEW CONSTRUCTION AND ANY EXISTING CONSTRUCTION. CENTER OF SPAN. TERMINATE CONTINUOUS BARS AT DISCONTINUOUS ENDS WITH STANDARD HOOKS. TJI JOISTS SECTIONS SHALL BE THE TYPE AND SIZE SPECIFIED ON THE PLANS, AS MANUFACTURED BY TRUSS

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEMBERS AND MATERIALS TO CONFORM TO ACTUAL SITE CONDITIONS. CONTRACTOR SHALL
SITE PREPARATION AND EARTHWORK PROCEDURE:
11. SHOP DRAWINGS SHALL INDICATE THE FOLLOWING: ALL NECESSARY REINFORCING, WALL REINFORCING
JOIST MCMILLAN LTD., OR EQUAL. FLANGE MEMBERS, WEB MEMBERS AND ADHESIVES SHALL CONFORM TO
THE PROVISIONS OF CABO REPORT NO. NER-200. COORDINATE BRIDGING AND STIFFENER REQUIREMENTS
CONTRACTOR
VERIFY AND NOTIFY THE ENGINEER AND ARCHITECT IMMEDIATELY IF SITE CONDITIONS DO NOT MATCH THE DESIGN DRAWING'S PLANS AND ON WALL ELEVATIONS INCLUDING ALL REQUIRED DOWELS, LOCATIONS OF ALL CONSTRUCTION AND WITH TJI MANUFACTURER.
1. GENERAL CONTRACTOR IS TO REVIEW AND FOLLOW REQUIREMENTS OUTLINED IN THE GEOTECHNICAL STONELEAF CONSTRUCTION
DETAILS. ALL DEVIATIONS SHALL BE NOTED IN EITHER SKETCH OR WRITTEN FORM TO THE ENGINEER AND ARCHITECT FOR REVIEW. CONTROL JOINTS. DETAILING AND AMOUNT OF REINFORCING FOR CONDITIONS NOT SHOWN SHALL BE
REPORT. 4974 Route 22 Amenia, NY 12501
PROVIDED AS SHOWN IN SIMILAR CONDITIONS. ALL INSERTS AND OTHER OBJECTS WHICH MAY AFFECT 4. PLYWOOD: T: (845) 373-8020
11. CONTRACTOR SHALL TAKE CARE TO PROTECT ALL EXISTING STRUCTURES AND UTILITIES FROM DAMAGE. PLACING OF REINFORCING BARS SHALL BE INDICATED ON THE SHOP DRAWINGS. SUB-FLOOR SHALL CONSIST OF 3/4" CDX PLYWOOD, GLUED AND SCREWED TO JOISTS.
2. REMOVE ALL SURFACE VEGETATION, ROOTS AND TOPSOIL, APPROXIMATELY ONE TO TWO FEET IN DEPTH,
FROM WITHIN AND AT LEAST FIVE FEET BEYOND THE CONSTRUCTION LIMITS. TOPSOIL WILL NOT BE
12. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. THE CONTRACTOR SHALL REFER TO 12. MINIMUM CLEAR CONCRETE COVER SHALL BE: 5. LAMINATED VENEER LUMBER:
SUITABLE FOR USE AS CONTROLLED COMPACTED FILL OR BACKFILL.
THE SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES OR THE STRUCTURAL DRAWINGS. DRAWINGS SHALL TAKE 3/4 INCH FOR SLABS
PRECEDENCE OVER SPECIFICATIONS. 1-1/2 INCHES FOR WALLS LAMINATED VENEER LUMBER SECTIONS SHALL BE "MICRO=LAM ®" (LVL) OR "PARALLAM ®" (PSL) AS STRUCTURAL ENGINEER
3. REMOVE ALL ABANDONED PIPELINES/UTILITIES FROM WITHIN AND AT LEAST FIVE FEET BEYOND
1-1/2 INCHES FOR BEAMS AND COLUMNS MANUFACTURED BY TRUS JOIST MACMILLAN, LTD. , OR EQUAL, WITH THE FOLLOWING MINIMUM PROPERTIES:
CONSTRUCTION LIMITS. MURRAY ENGINEERING
13. IF THERE APPEARS TO BE A CONFLICT BETWEEN NOTES, DETAILS, OR SPECIFICATIONS, CONTRACTOR SHALL APPLY THE MOST RIGID 2 INCHES FOR ALL CONCRETE EXPOSED TO WEATHER OR EARTH FOR BARS #6 OR GREATER FB = 2865 PSI, FC = 750 PSI, FV = 285 PSI, E = 2,000,000 PSI.
REQUIREMENTS TO THE WORK. CONTRACTOR SHALL NOT DEVIATE FROM DRAWINGS WITHOUT WRITTEN APPROVAL OF ENGINEER. 1 1/2 INCHES FOR ALL CONCRETE EXPOSED TO WEATHER OR EARTH FOR BARS #5 OR LESS 330 7th Avenue New York, NY 10001
4. EXCAVATE TO REACH THE DESIRED FLOOR SLAB AND PAVEMENT SUB-GRADE LEVELS. T: (212) 741-1102
3 INCHES FOR ALL CONCRETE CAST AGAINST EARTH MULTIPLE SECTIONS SHALL BE FASTENED TOGETHER WITH A MINIMUM OF TWO ROWS OF 16D NAILS AT 12"
14. CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING AND/OR SHORING FOR ALL STRUCTURAL WORK AS REQUIRED FOR STABILITY 4 INCHES FOR ALL CONCRETE PLACED AGAINST PERMANENT SHEETING. o.c., AND AS RECOMMENDED BY THE MANUFACTURER.
5. PROOF-ROLL AND COMPACT THE EXPOSED SUB-GRADE SOILS TO A FIRM AND UNYIELDING
OF THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. THESE DIMENSIONS ARE TYPICAL, UNLESS OTHERWISE NOTED ON PLANS AND DETAILS.
CONSISTENCY. PROOFROLLING MAY BE ACCOMPLISHED BY USING A HEAVY STEEL DRUM VIBRATORY
6. ALL EXTERIOR WOOD FRAMING MEMBERS ARE TO BE PRESSURE - TREATED. ALL EXTERIOR PSL FRAMING
15. COORDINATE NUMBER, SIZE, AND LOCATIONS OF SLEEVES THROUGH FOUNDATION WALLS WITH ALL OTHER TRADES.
ROLLER (DYNAPAC CA-15, OR EQUIVALENT) WITHIN THE PROPOSED BUILDING AND PAVEMENT AREAS.
ANY LOCALIZED AREAS WHICH CANNOT BE COMPACTED TO A FIRM AND UNYIELDING CONSISTENCY
13. ALL ADJOINING SURFACES NOT CAST MONOLITHICALLY SHALL BE ROUGHENED TO 1/4 INCH AMPLITUDE
FOR THE ENTIRE INTERSECTING SURFACE ACCORDING TO ACI RECOMMENDATIONS.
MEMBERS ARE TO BE "WOLMANIZED". FOR SERVICE LEVEL 2 EXCEPT WHEN USED IN CONTACT WITH THE
GROUND OR SATURATED USE, USE SERVICE LEVEL 3.
LANDSCAPE ARCHITECT
SHOULD BE EXCAVATED TO STABLE SUB-GRADE SOILS AND BACKFILLED WITH CONTROLLED COMPACTED
16. CONTRACTOR AND OWNER SHALL GAIN ACCESS TO ALL ADJOINING PROPERTIES, AS DEFINED BY NYCBC SECTION 3309 {PROTECTION OF
FILL. COMPACTED FILL SHOULD ALSO BE INSTALLED IN ANY EXCAVATIONS NECESSARY TO REMOVE JAMES DOYLE DESIGN ASSOCIATES
ADJOINING PROPERTY} AND TPPN/10-88 WHEN APPLICABLE. THE OWNER AND CONTRACTOR SHALL JOINTLY AND KNOWINGLY CONDUCT A 14. CONTRACTOR SHALL NOT USE VERTICAL CONSTRUCTION JOINTS IN WALLS WITHOUT PRIOR APPROVAL OF 7. WHEN WORKING WITH PRESSURED - TREATED LUMBERS, USE MINIMUM G185 GALVANIZED HANGERS AND 125 Greenwich Avenue Greenwich, CT 06830
PIPES.
FULL AND APPROPRIATE PRE-CONSTRUCTION SURVEY OF THE ADJOINING PROPERTIES AND CONDITIONS IN ACCORDANCE WITH THE NYCBC ENGINEER, AND NOT WITHIN 8 FEET OF ANY COLUMN LINE OR WALL OPENING FOR FOUNDATION WALLS. HOT - DIPPED FASTENERS, OR STAINLESS - STEEL HANGERS AND FASTENERS. DO NOT MIX STAINLESS - STEEL T: (203) 869-2900
AND STANDARDS OF GOOD PRACTICE IN ORDER TO FULLY UNDERSTAND THE EXISTING CONDITIONS AND STRUCTURAL SYSTEM. THIS AND GALVANIZED MATERIALS.
6. TO MINIMIZE THE DISTURBANCE OF THE SUB-GRADE SOILS, GRADE THE SITE TO MAINTAIN POSITIVE
SURVEY SHALL BE CONDUCTED PRIOR TO THE COMMENCEMENT OF ANY WORK AND AT REASONABLE PERIODS DURING THE PROGRESS OF 15. CONTRACTOR SHALL NOT USE HORIZONTAL CONSTRUCTION JOINTS IN BEAMS, WALLS, OR SLABS
SURFACE DRAINAGE AT ALL TIMES AND CONSTRUCT SWALES AND/OR BERMS TO MINIMIZE THE AMOUNT
WORK. WITHOUT PRIOR APPROVAL OF ENGINEER. 8. ALL BEARING STUD WALLS SHALL HAVE CROSSKATS AT MID-HEIGHT OR 4'-6" o.c. MINIMUM.
OF SURFACE RUN-OFF ENTERING THE CONSTRUCTION AREAS.
17. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL FOR ALL STRUCTURAL ELEMENTS / TRADES. SHOP DRAWINGS 16. CONTRACTOR SHALL PROVIDE REINFORCING STEEL ERECTOR WITH A SET OF STRUCTURAL PLANS FOR 9. USE DOUBLE MEMBERS AT JAMBS AND HEADS OF ALL OPENINGS. USE DOUBLE SILLS AND CAP PLATES FOR
SURVEYOR/ CIVIL ENG.
7. PLACE CONTROLLED COMPACTED FILL AS REQUIRED TO ACHIEVE THE DESIRED SUBGRADE LEVELS IN
SHALL BE PROVIDE IN A TIMELY FASHION TO ALLOW ADEQUATE TIME FOR REVIEW AND REVISIONS PRIOR TO FABRICATION. FIELD USE. ALL BEARING WALLS.
THE BUILDING AND PAVEMENT AREAS. SPREAD FILL IN LAYERS ON THE ORDER OF TWELVE INCHES IN INSITE ENGINEERING, SURVEY & LANDSCAPE
LOOSE THICKNESS AND COMPACT UNIFORMLY TO AT LEAST 95 PERCENT OF MAXIMUM DRY DENSITY AS ARCHITECTURE, P.C.
18. THE OWNER IS TO ENGAGE AN INDEPENDENT, QUALIFIED SPECIAL INSPECTOR PRIOR TO THE COMMENCEMENT OF WORK. 17. CONTRACTOR SHALL VERIFY DIMENSIONS AND LOCATIONS OF ALL OPENINGS, PIPE SLEEVES, CURBS, ETC. 10. ALL FLOOR JOISTS SHALL BE PROPERLY SECURED TO SUPPORTS. 3 Garret Place, Carmel, New York 10512
ATTAINED BY THE ASTM D-1557 TEST PROCEDURE. BACKFILL PLACED IN CONFINED AREAS SUCH AS
AS REQUIRED BY OTHER TRADES BEFORE CONCRETE IS PLACED. T: (845) 225-9690
FOUNDATION OR UTILITY TRENCHES SHOULD BE INSTALLED IN THINNER LIFTS AND COMPACTED TO THE
19. CONTRACTOR SHALL NOTIFY THE ENGINEER AT LEAST 2 WEEKS PRIOR TO THE COMMENCEMENT OF ANY WORK. THE SPECIAL INSPECTION 11. ALL FLOOR JOISTS SHALL HAVE CROSS BRIDGING AT 8'-0" ON CENTER MAXIMUM OR AT CENTER OF SPAN IF
SAME DEGREE WITH MANUAL COMPACTION EQUIPMENT. ALL FILL SHOULD BE MOISTURE CONDITIONED
ENGINEER SHALL BE PROVIDED THE SAME NOTICE. 18. CONTRACTOR SHALL COORDINATE SLAB DEPRESSIONS FOR FLOOR FINISHES WITH ARCHITECTURAL LESS THAN 16'-0" IN LENGTH.
AS NECESSARY TO PERMIT COMPACTION TO THE REQUIRED DENSITIES.
DRAWINGS.
20. THE CONTRACTOR SHALL HIRE A REGISTERED AND EXPERIENCED PROFESSIONAL ENGINEER TO DESIGN, 12. SUPPORT FOR ALL NON-LOAD BEARING WALLS SHALL:
8. BACKFILL REQUIREMENTS ARE AS FOLLOWS:
SUPERVISE AND INSPECT ALL SHORING AND EXCAVATION REQUIRED FOR THIS PROJECT. THIS ENGINEER SHALL PREPARE AND SUBMIT A 19. CONTRACTOR SHALL COORDINATE LOCATION OF SLOTTED INSERTS, WELDED PLATES, AND OTHER ITEMS
· EXCAVATED MATERIALS WHICH CONSIST OF SILTY SANDS AND WHICH ARE MOISTURE CONDITIONED AS
SEPARATE SET OF DRAWINGS TO THE BUILDING DEPARTMENT OUTLINING ALL ENGINEERED SHORING, EXCAVATION AND SPECIAL SITE TO BE EMBEDDED IN CONCRETE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. a. WALLS PARALLEL TO JOISTS, PROVIDE DOUBLE FLOOR JOISTS BELOW WALL.
NECESSARY TO PERMIT COMPACTION TO THE REQUIRED DENSITIES MAY BE USED AS BACKFILL.
CONSIDERATIONS, INCLUDING PROTECTION OF ADJACENT STRUCTURES AND PROPERTY, WHERE THIS WORK IS SHOWN ON THE DRAWINGS
· IMPORTED MATERIALS TO BE USED AS BACKFILL SHOULD CONSIST OF UNCONTAMINATED, RELATIVELY
PREPARED BY MUESER RUTLEDGE, THE GEOTECHNICAL ENGINEERS ON THIS PROJECT. 20. PIPES OR CONDUITS PLACED IN SLABS SHALL NOT BE SPACED CLOSER THAN 3 TIMES THE DIAMETER ON b. WALLS PERPENDICULAR TO JOISTS, PROVIDE SOLID BLOCKING BELOW WALL.
WELL- GRADED SAND AND/OR GRAVEL CONTAINING LESS THAN 15 PERCENT BY WEIGHT PASSING AN
CENTER. PIPES AND CONDUITS PLACED IN SLABS SHALL NOT HAVE AN OUTSIDE DIAMETER LARGER THAN
U.S. STANDARD NO. 200 SIEVE, AND WITH A MAXIMUM PARTICLE SIZE OF FOUR INCHES.
21. CONTRACTOR SHALL BE RESPONSIBLE TO GENERATE A SET OF AS BUILT DOCUMENTS AFTER COMPLETION OF WORK. THIS AS-BUILT SET 1/3 \ OF SLAB THICKNESS. ALUMINUM CONDUITS SHALL NOT BE PLACED IN CONCRETE. NO CONDUITS 13. WOOD TRUSSES:
DOCUMENTATION OF THE ENVIRONMENTAL QUALITY OF THE FILL SHOULD INCLUDE A WRITTEN
SHALL INCLUDE ALL COORDINATION, ADDITIONS AND REVISIONS MADE TO THE PLANS, DETAILS AND JOB SPECIFICATIONS, INCLUDING . THE SHALL BE PLACED IN THE SLAB WITHIN 2*(SLAB THICKNESS) OF ANY COLUMN FACE.
CERTIFICATION FROM THE FILL SUPPLIER STATING THAT THE FILL IS VIRGIN MATERIAL FROM A
INTENTION OF THIS RECORD SET WILL BE AS NECESSARY FOR THE OWNERS' RECORDS, THE LOCAL MUNICIPALITIES' REQUEST AND THE ALL WOOD TRUSSES ARE TO BE DESIGNED BY MANUFACTURER'S ENGINEER FOR ANTICIPATED
COMMERCIAL OR NONCOMMERCIAL SOURCE.
ENGINEER'S RECORDS. 21. CONTRACTOR SHALL ENSURE THAT FLOOR SLABS ARE POURED TO A LEVEL SURFACE, WITH ADDITIONAL LOADING INDICATED. MANUFACTURER IS TO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR REVIEW AND
CONCRETE IF DEFLECTION DEEM NECESSARY. APPROVAL PRIOR TO FABRICATION. CALCULATIONS ARE TO BE SIGNED AND SEALED BY N.Y. STATE LICENSED
9. FOUNDATION EXCAVATIONS SHALL BE KEPT FREE OF WATER AT ALL TIMES.
PROFESSIONAL ENGINEER.
ALL DESIGNS & SPECS ARE SUBJECT TO
10. THE FOUNDATION EXCAVATIONS SHOULD BE EXTENDED BY AN ADDITIONAL SIX INCHES BENEATH THE VERIFICATION OF EXG. FIELD CONDITIONS
STRUCTURAL STEEL: PROPOSED FOUNDATION SUB-GRADE LEVELS AND THE EXCAVATIONS BE BACKFILLED WITH CLEAN
THREE-QUARTER INCH CRUSHED STONE, TO PROVIDE A STABLE WORKING SURFACE AND HELP PROTECT
1. ALL STRUCTURAL STEEL SHALL CONFORM TO THE REQUIREMENTS OF THE AISC "SPECIFICATIONS FOR THE SUB-GRADE SOILS FROM DISTURBANCE AND SOFTENING IN THE EVENT THAT THESE MATERIALS
BECOME WET DURING CONSTRUCTION.
REVISIONS
STRUCTURAL STEEL FOR BUILDINGS" - 13TH EDITION AND ALL CURRENT SUPPLEMENTS. FOR OTHER CODE
AND SPECIFICATION REQUIREMENTS, SEE THE CONTRACT SPECIFICATIONS.
11. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE SUPPORTS AND BRACING TO PROTECT ALL
2. ALL WELDING WORK SHALL CONFORM TO THE AMERICAN WELDING SOCIETY CODE AWS D1.1. ALL EXCAVATION SLOPES. LIST OF ABBREVIATIONS:
WELDING WORK SHALL BE DONE BY AWS CERTIFIED WELDERS. FIELD WELDING SHALL BE DONE BY THE
12. CONTRACTOR SHALL BE RESPONSIBLE FOR UNDERPINNING TO PROTECT EXISTING STRUCTURES, WHERE TYP. TYPICAL
MANUAL SHIELDED METAL ARC WELDING METHOD.
EXCAVATIONS FOR FOUNDATIONS ARE DEEPER THAN EXISTING STRUCTURES' FOUNDATIONS. o.c. ON CENTER
VERT. VERTICAL
3. CONTRACTOR SHALL BE RESPONSIBLE TO CHECK AND COORDINATE DIMENSIONS, CLEARANCES, ETC.
HORZ. HORIZONTAL
BETWEEN STRUCTURAL DRAWINGS, ARCHITECTURAL DRAWINGS, MECHANICAL DRAWINGS, AND DRAWINGS
T.O. TOP OF
OF OTHER TRADES.
B.O. BOTTOM OF
4. ALL STEEL PLATES, ANGLES, BARS, RODS, AND ANCHOR BOLTS, SHALL CONFORM TO ASTM A36. TJI TIMBER I JOIST BY TRUS JOIST NOT FOR CONSTRUCTION
LVL LAMINATED VENEER LUMBER BEAM
PSL PARALLAM BEAM
5. ALL STEEL SHAPES SHALL CONFORM TO ASTM A992. ALL STEEL CHANNELS SHALL CONFORM TO ASTM A36,
PSF. POUNDS PER SQUARE FOOT
UNLESS NOTED OTHERWISE.
PSI. POUNDS PER SQUARE INCH
SQ. SQUARE
6. ALL STEEL TUBES SHALL CONFORM TO ASTM A500, GRADE B. ALL STEEL PIPES SHALL CONFORM TO ASTM
GA. GAUGE
A53 TYPE E, GRADE B, OR TYPE S GRADE B.
LBS. POUNDS
IN. INCH
7. ALL BOLTS IN GRAVITY BEAMS SHALL BE 3/4" DIAMETER ASTM A325N BOLTS IN BEARING TYPE
FT. FEET
CONNECTIONS, UNLESS OTHERWISE NOTED SPECIFICALLY ON THE DRAWINGS. PROVIDE A MINIMUM OF
U.O.N. UNLESS OTHERWISE NOTED
TWO BOLTS PER CONNECTION, UNLESS SHOWN OTHERWISE ON THE DRAWINGS.

8. ALL WELDING ELECTRODES SHALL BE E70XX LOW HYDROGEN.

9. WHERE NO WELDING IS SHOWN IN CONNECTING THE STEEL ELEMENTS, PROVIDE A 1/4" FILLET WELD ALL
AROUND, UNLESS A LARGER WELD SIZE IS REQUIRED AS A MINIMUM WELD SIZE BY AISC.

10. ALL GROOVE WELDS SHALL BE AWS PRE-QUALIFIED COMPLETE JOINT PENETRATION GROOVE WELDS, SIGN & SEAL
UNLESS NOTED OTHERWISE ON THE DRAWINGS.

11. STEEL FOR SHEAR STUD CONNECTIONS SHALL CONFORM TO THE REQUIREMENTS OF THE STRUCTURAL
ISSUES
WELDING CODE, AWS D1.1, LATEST EDITION. CONTRACTOR SHALL ENSURE CONFORMITY WITH 01 2021.10.21 CORE AND SHELL PRICING SET
SPECIFICATIONS AND MANUFACTURER CERTIFICATION. 02 2022.04.25 UPDATED FLOOR PLANS
03 2022.05.02 INT. BUDGET ASSUMPTIONS
12. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF THE STEEL AND METAL DECK TO THE ENGINEER FOR 04 2022.05.27 PROGRESS SET
HIS REVIEW, PRIOR TO FABRICATION. 05 2022.06.10 PROGRESS SET
06 2022.06.17 PROGRESS SET
13. ALL STEEL SHALL BE CLEANED AS PER SSPC SP2 HAND TOOL CLEANING, OR SSPC SP3, POWER TOOL
CLEANING AND BE PAINTED WITH A PRIMER CONFORMING TO SSPC-PAINT 13 (RED OR BROWN ONE COAT
SHOP PAINT). FINISH COAT SHALL BE COORDINATED WITH THE ARCHITECT.

14. SPLICE LOCATIONS SHALL NOT DEVIATE FROM DRAWINGS WITHOUT WRITTEN APPROVAL OF THE
ENGINEER.

15. OVERSIZED OR SLOTTED HOLES SHALL NOT BE USED FOR ANY CONNECTIONS UNLESS SPECIFICALLY DRAWING INFO
INDICATED ON THE DRAWINGS OR ACCORDING TO EXPRESS WRITTEN APPROVAL OF THE ENGINEER.
CONSTRUCTION DOCUMENTS
16 THE STRUCTURAL STEEL CONTRACTOR SHALL COORDINATE THE BOTTOM OF BASE PLATE ELEVATION WITH DRAWN BY: Author
THE TOP OF CONCRETE ELEVATION. IN CASE OF CONFLICT, CONTRACTOR SHALL MAKE ALLOWANCE FOR CHECKED BY: Checker
MOST RIGID REQUIREMENTS. DATE: 05/26/22
SCALE: 1 1/2" = 1'-0"
17 AT POINTS OF CONCENTRATED LOAD, PROVIDE WELDED STIFFENER PLATES ON BOTH SIDES OF THE WEB PROJ. NO. Project Number
OF BEAMS. MINIMUM PLATE THICKNESS TO BE GREATER OF FLANGE THICKNESS OF COLUMN ABOVE OR
BELOW, OR 1/2 INCH.
GENERAL NOTES
18 FILLER BEAMS SHOULD BE SPACED EQUALLY BETWEEN THE SUPPORTS, UNLESS OTHERWISE NOTED ON

G-002
THE DRAWINGS.

19 CUTS, HOLES, COPING, ETC. REQUIRED FOR WORK OF OTHER TRADES SHALL BE SHOWN ON THE SHOP
DRAWINGS AND MADE IN THE SHOP.CUTTING OR BURNING HOLES IN STRUCTURAL STEEL MEMBERS SHALL
NOT BE DONE IN THE FIELD.
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
20. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE LATERAL SUPPORT OF THE BUILDING DURING
CONSTRUCTION THROUGH TEMPORARY BRACING OR GUYS.
RR2
3
CENTERLINE OF
TRANSFER BEAM ABOVE

4
12" WING WALL (TYP.)
CENTERLINE OF
2
RESIDENCE
TRANSFER BEAM ABOVE

CENTERLINE OF WALL
CENTERLINE OF
8" CONCRETE FROST WALL TRANSFER BEAM ABOVE
12" CONCRETE RETAINING WALL PROVIDE #5@16" o.c. 1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
(SEE ARCH. FOR FINISH MATERIAL) VERTICAL AND HORIZONTAL
4" EXTERIOR CONCRETE
5 UPDATE PERARCH MODEL,

(yg§
SLAB ON GRADE
OWNER
.

18" WIDE x 10" THICK CONC. FTG. " " " "" " "
PROVIDE (3)-#5 LONG BARS AND REINFORCE WITH 1 LAYER
#5@16" o.c. SHORT BARS 6x6 - 2.9x2.9 WWF
(TYP. @ BASEMENT) 3 RR ORCHARD HOLDINGS LLC
1347 HOLLOW RD, CLINTON CORNERS, NY 12514
4 S-303 12" WING WALL (TYP.)
10" CONCRETE WALL. CURVED SLAB EDGE,
SIM.
FOUNDATION/BASEMENT PLAN
3 S-303
PROVIDE #5@16" o.c.
VERTICAL AND HORIZONTAL S-203
OVERHANG VARIES
1 ARCHITECT
1 2-2X6 POST UP IN MULLION
1 (TYP. @ BASEMENT)
S-203 S.F.D.
(TYP.)
6 S-100 1/8" = 1'-0"
CENTERLINE OF WALL
WORKSHOP/APD ARCHITECTURE DPC
39 W 38th Street, 7th Fl, New York, NY 10018
T: (212) 273-9712 info@workshopapd.com
I

CENTERLINE OF CONCRETE WALL NOTES:


1. REFER TO GEOTECHNICAL REPORT PREPARED BY DANIEL LOUCKS, PE DATED JUNE 20, 2022.
8" CONCRETE WALL 4" CONCRETE SLAB ON 2. CONTRACTOR TO COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECT'S DRAWINGS.
LINE OF HOT TUB ABOVE
GRADE REINFORCE WITH
PROVIDE #5@16" o.c.
VERTICAL AND HORIZONTAL 1 LAYER 6x6 - 2.9x2.9 WWF
3. CONTRACTOR TO COORDINATE TOP OF FOUNDATION WALLS, STEPPED FOOTINGS, WALL
PENETRATIONS FOR UTILITIES, AND EXISTING CONDITION WITH ARCHITECTURAL DRAWINGS AND
CONTRACTOR
(TYP. @ CRAWLSPACE) 10" WIDE X 10" DEEP CONCRETE OTHER TRADES.
GRADE BEAM. PROVIDE 4-#5 STONELEAF CONSTRUCTION
4. CONTRACTOR TO PROVIDE AND IS RESPONSIBLE FOR ANY SHORING MEASURES REQUIRED.
BARS AND #3 TIES @ 12" O.C. 4974 Route 22 Amenia, NY 12501
18" WIDE x 10" THICK CONC. FTG. S. 5. INTERIOR SLAB ON GRADE TO BE SET ON MIN. 6" GRAVEL
F. T: (845) 373-8020
PROVIDE (3)-#5 LONG BARS AND D . GARAGE AND EXTERIOR SLAB ON GRADE TO BE SET ON MIN. 12" GRAVEL.
#5@16" o.c. SHORT BARS -12' - 3" 6. DENOTES STEEL COLUMN.
(TYP. @ CRAWLSPACE)

2
S-203
S .F .
D.
%
1
S-201
☐ MATCH ARCH
BACKGROUND,
.
12" CONCRETE RETAINING
WALL(SEE ARCH. FOR
FINISH MATERIAL)
7. REFER TO DRAWINGS S-200 FOR GENERAL NOTES, TYPICAL DETAILS, AND SCHEDULES.
8. (U.O.N) DENOTES UNLESS OTHERWISE NOTED.
9. (S.F.D) DENOTES APPROX. LOCATION OF STEPPED FOOTING DOWN TO 4'-0" BELOW GRADE VERIFY IN
FIELD.
STRUCTURAL ENGINEER
THISDOORSHIFTED CU 10. (#'-#") = APPROXIMATE FINISHED GRADE. COORDINATE WITH ARCHITECT'S SITE PLAN. MURRAY ENGINEERING
RVE T.O.F.= -13' - 1" 4'-0" X 4'-0" CONCRETE FOOTING.
D 11. [T.O.F.] = TOP OF CONCRETE FOOTING. 330 7th Avenue New York, NY 10001
CO (TYP. 2 LOC.)
NC 12. [T.O.W.] = TOP OF CONCRETE WALL @ JOIST SHELF. T: (212) 741-1102
.W
ALL 13. [T.O.S.W.] = TOP OF CONCRETE WALL @ STEM.
3" RAT SLAB 72 "W
18" X 18" CONCRETE
f0PENH# PIER (TYP. 2 LOC.)
/
LANDSCAPE ARCHITECT
¥É%
,

.
.D JAMES DOYLE DESIGN ASSOCIATES
S.F SOLID CONCRETE FIRE
125 Greenwich Avenue Greenwich, CT 06830
PLACE BASE (ALT: CMU)
T: (203) 869-2900
10"/14" CONCRETE WALL (6" STEM+6"
SHELF, ONE OR BOTH SIDES, SEE ARCH)
PROVIDE #5 @ 12" O.C. VERTICAL AND
SURVEYOR/ CIVIL ENG.

6" (T
HORIZONTAL (TYP. @ RADIAL WALLS) 4" EXTERIOR CONCRETE
SLAB ON GRADE COORD.

YP.
WINDOW WELL AND INSITE ENGINEERING, SURVEY & LANDSCAPE

)
-µ,µygwgÉ
30" WIDE X 10" THICK CONCRETE FOOTING. DRAINAGE WITH ARCH. ARCHITECTURE, P.C.
PROVIDE 3 - #5 LONG BARS AND 3 Garret Place, Carmel, New York 10512
CHANGE WALLS BACK -10 CURVES
#5 @ 16" SHORT BARS 4" CONCRETE SLAB ON
,
T: (845) 225-9690
MATCH ARCH MODEL
(TYP. @ RADIAL WALLS) GRADE REINFORCE WITH
.

1 LAYER 6x6 - 2.9x2.9 WWF

-12' - 3"
36"x36"X10" CONCRETE
FOOTING (TYP. 12 LOC.)
PROVIDE (4)-#5 BOT.
36"W✗48"H BARS BOTH WAYS

fPEN1
7
W.P.
PIPE 3.5 STD POST ALL DESIGNS & SPECS ARE SUBJECT TO

D.
UP (TYP. 12 LOC.) CENTERLINE OF CONCRETE WALL VERIFICATION OF EXG. FIELD CONDITIONS

S.F.
3" CONC. RAT SLAB
REVISIONS

S.F.D.
-6' - 10"

%"p

G #
3" CONC. RAT SLAB
F 10" CONCRETE NOT FOR CONSTRUCTION
WALL
E
8" CONCRETE
-6' - 10"
WALL
16"X16" CONCRETE
D 0PIER9TYP.(2 LOC.)

C CENTERLINE OF CONCRETE WALL

3" CONC. RAT SLAB

B
8
A
SIGN & SEAL
CONTROLLED COMPACTED BACKFILL.
GARAGE SLAB ON GRADE ABOVE CONTROLLED, COMPACTED
-6' - 10"
BACKFILL. EXTERIOR SLAB ON ISSUES
GRADE ABOVE.
2 01 2021.10.21 CORE AND SHELL PRICING SET
S-203 02 2022.04.25 UPDATED FLOOR PLANS
03 2022.05.02 INT. BUDGET ASSUMPTIONS
@ CRAWLSPACE 04 2022.05.27 PROGRESS SET
CENTERLINE OF CONCRETE WALL
05 2022.06.10 PROGRESS SET
8" CONCRETE WALL 06 2022.06.17 PROGRESS SET
PROVIDE #5@16" o.c.
VERTICAL AND HORIZONTAL
(TYP. @ CRAWLSPACE) 9
18" WIDE x 10" THICK CONC. FTG.
8" CONCRETE WALL
PROVIDE #5@16" o.c.
3
PROVIDE (3)-#5 LONG BARS AND
#5@16" o.c. SHORT BARS
DRAWING INFO
VERTICAL AND HORIZONTAL
S-203 (TYP. @ CRAWLSPACE) CONSTRUCTION DOCUMENTS
(TYP. @ GARAGE)
DRAWN BY: Author
18" WIDE x 10" THICK CONC. FTG. @ FROST WALL / CHECKED BY: Checker
PROVIDE (3)-#5 LONG BARS AND GARAGE DOOR DATE: 10/15/20
#5@16" o.c. SHORT BARS SCALE: As indicated
(1/4--603)
(TYP. @ GARAGE) PROJ. NO. Project Number

CENTERLINE OF CONCRETE WALL FOUNDATION PLAN

S-100
CENTERLINE OF CONCRETE WALL

11

COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC

10
RR2
3

4
THESE POSTS NEED TO SHIFT
WING WALL
2
RESIDENCE
TO FALL IN ARCH WINDOW
(BELOW .

MULLION
GRADE) (TYP.)

GRADE HIGH GRADE LOW 1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
(-10'±)
EXTERIOR ABOVE, INTERIOR BELOW.
DROP FRAMING TO ACCOMMODATE 5 OWNER
INSULATION, FINISH, AND DRAINAGE
12" CONCRETE

"g÷;
2-2X6 POST IN MULLION RETAINING WALL RR ORCHARD HOLDINGS LLC
SECTION
(TYP.) 1347 HOLLOW RD, CLINTON CORNERS, NY 12514
12" CONCRETE CREATE
CUT HERE

RETAINING WALL GRADE LOW 4 WING WALL (BELOW GRADE)

÷
: ÷↑
7
6
S-203
REF .

S-203 7A
6X6 P.T. POST UP,
(-10'±) S-303 (TYP.)
1 FIRST FLOOR FRAMING PLAN ARCHITECT
1 S-203 (TYP. 2 LOC.)
6 S-101 1/8" = 1'-0"
5
S-203 (2) 1 3/4x14 LVL WORKSHOP/APD ARCHITECTURE DPC
39 W 38th Street, 7th Fl, New York, NY 10018
BELOW WALL LEGEND AND NOTES: T: (212) 273-9712 info@workshopapd.com
M AX 14 T
16 " o.c. JI 230
@ 3 1. CONTRACTOR TO COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECT'S
0 @ 16" o
3 1/2"Ø PIPE COLUMN
14 T JI 23 (3) 1 3/4x14 LVL .c . MA S-303
DRAWINGS
DOWN (TYP.)
1
GIRDER (LOW) X 2.
3.
CONTRACTOR TO PROVIDE AND IS RESPONSIBLE FOR ANY SHORING MEASURES REQUIRED.
ALL FLOOR JOISTS TO BE 14 TJI 230 @ 16" O.C. U.O.N.
CONTRACTOR
FACETED RIM BOARD (TYP.) S-201 GRADE HIGH MIN. 4" CONCRETE SLAB ON 4. JOISTS ARE LAID OUT PARALLEL TO ONE RADIAL WALL THEN CUT AT ANGLE AT OTHER AS
STONELEAF CONSTRUCTION
COORDINATE CURVED FINISH -1' - 2 3/4" GRADE. REINFORCE WITH 1 SHOWN ON PLAN.
4974 Route 22 Amenia, NY 12501
BUILD-OUT WITH ARCHITECT. 5. WHERE JOISTS RUN PARALLEL TO EXTERIOR WALL, PROVIDE BLOCKING @4'-0" IN THE TWO
OW ) (3) 1 3 • LAYER 6X6 - 2.9X2.9 WWF (SEE
ARCH. FOR FINISH MATERIAL) END BAYS.
T: (845) 373-8020
ER (L
(2) 1 3/4x14 LVL
1 4 LV L G
IRD
/4x14
LVL G*
IRDER 6. STUD POSTS WITHIN WALLS TO BE 2-2X4/6 (U.O.N)

L
x (LOW
1 3/4 14 7. DENOTES WOOD POST UP.

LV
(3) 1 3/4x14 LVL
(3) )
FOUNDATION WALL BELOW, 14 TJI 2 16 TJ 10. DENOTES STEEL COLUMN DOWN.

14
30 @ 16 "o I2 STRUCTURAL ENGINEER

/4x
FIRST FLOOR JOIST " o.c MA .c 3 0 6X6 P.T. POST UP, 11. REPRESENTS WALLS BELOW.
X STUD WALL

13
OVERHANG VARIES (TYP.) X (2) 3/4 M @ CLADDING PER ARCH. 12. (2)3/4" DENOTES SPAN DIRECTION OF 2 LAYERS 3/4" PLYWOOD SUB-FLOOR GLUED AND
MA 3/4 (2) AX BELOW (TYP.)
(2)

(2
(3)
. 13 (TYP. 2 LOC.) SCREWED TO THE TOP OF FLOOR JOISTS. MURRAY ENGINEERING
o. c

)3
-1' - 2 3/4" " / 4x

/4
13. REFER TO DRAWINGS S-200 FOR GENERAL NOTES, TYPICAL DETAILS, AND SCHEDULES. 330 7th Avenue New York, NY 10001
16 14
LV
/4 T: (212) 741-1102
3 0 @ (2) 3 L 14. (U.O.N) DENOTES UNLESS OTHERWISE NOTED.
I2 15. CONTRACTOR TO COORDINATE WITH MECHANICAL DRAWINGS FOR ANY PENETRATIONS

b④
TJ "
4.5 THROUGH CONCRETE SLABS/WALLS.

14
14

T
4.

JI
5
LANDSCAPE ARCHITECT

-7
" MIN. 4" CONCRETE SLAB ON

(3)

23
"
NO POSTS , RIDGE BEAM


6 3

0
GRADE. REINFORCE WITH 1

13
" " " " " """ " "" " E "

@
S-205 S-201 (3) 1 3/4x14 LVL LAYER 6X6 - 2.9X2.9 WWF (SEE

/4x

16
ARCH. FOR FINISH MATERIAL) JAMES DOYLE DESIGN ASSOCIATES

14

"
o.c
(2) 1 3/4x14 LVL 125 Greenwich Avenue Greenwich, CT 06830

L
VL

.
T: (203) 869-2900

MA
GIR
9 1/2" TJI @ 16" o.c.

X
CONCRETE STAIR.COORD.

DE
DROPPED FRAMING AT SHOWER
FINISH WITH ARCH. (TYP.)

R(
MASONRY
SURVEYOR/ CIVIL ENG.

LO
FOUNDATION WALL BELOW (TYP.) ✗ FIREPLACE

W)
2X6 @ 16" O.C. LSL STUD WALL COORD. COORD. W/ ARCH.
INSITE ENGINEERING, SURVEY & LANDSCAPE
UP CONCRETE WALL BELOW WINDOW WELL ✗ ARCHITECTURE, P.C.
(TYP.) WITH ARCH. 6
3 Garret Place, Carmel, New York 10512

(2) 3/4
S-201

14 TJI 2
T: (845) 225-9690

(3) 1
BRICK SHELF BELOW (TYP.)
FOUNDATION WALL
BELOW, FIRST FLOOR JOIST

3
/4x14
4" CONCRETE SLAB ON GRADE OVERHANG VARIES (TYP.)

30 @ 1
REINFORCE WITH 1 LAYER -0' - 7"

L
6x6-W2.9xW2.9 W.W.F.

VL G

6" o.c.
COORDINATE SLOPE AND

IRDE
DRAINAGE WITH ARCHITECT.

M
R (LO

AX
W)
-7"
7
W.P.
ALL DESIGNS & SPECS ARE SUBJECT TO

AX
VERIFICATION OF EXG. FIELD CONDITIONS

M
o.c.
4
(2) 3/
REVISIONS

16"
0@
I 23
-0' - 0 3/4"
MIN. 4" CONCRETE SLAB ON

J
14 T
GRADE. REINFORCE WITH 1

L
LAYER 6X6 - 2.9X2.9 WWF (SEE

LV
ARCH. FOR FINISH MATERIAL)

x 14
G

3/4
SHEAR WALL UP
FOUNDATION WALL BELOW,

1
(2)
FIRST FLOOR JOIST OVERHANG
STEEL FRAME -0' - 0 3/4"
VARIES (TYP.)
F

L
SEE ELEVATION

LV
NOT FOR CONSTRUCTION

14
HSS3 1/2x3 1/2x1/4 UP

x
E 2 - 1 3/4 X 14

3/4
SHEAR WALL UP (TYP. @ 2 LOCATIONS)
LVL GIRDER

1
(2)
(2) 2X6 @ 16" O.C. STUD WALL UP
POST DOWN 3/4
CONCRETE WALL BELOW (TYP.)
14 (2)
T JI 1
D BRICK SHELF
23
0@
3/4
x1
4L
16 VL POST UP
BELOW (TYP.) "o GI
C .c.
MA
RD
ER
(TYP. @ 2 LOC.)
X (LO PIPE 3.5 STD
W)
B POST DOWN
(TYP.)
W)
LO
A I RDE
R (
8
MIN
L G
LV
.

14
V
5" CONCRETE SLAB ON GRADE /4 x SIGN & SEAL
13 3/4
REINFORCE WITH 1 LAYER (2) (2) X
6x6-W2.9xW2.9 W.W.F. MA
.c.
COORDINATE SLOPE AND
-0' - 0 3/4" 16"o ISSUES
DRAINAGE WITH ARCHITECT. 0@ MIN. 4" CONCRETE SLAB ON 01 2021.10.21 CORE AND SHELL PRICING SET
I 23
TJ GRADE. REINFORCE WITH 1 02 2022.04.25 UPDATED FLOOR PLANS
14 LAYER 6X6 - 2.9X2.9 WWF (SEE 03 2022.05.02 INT. BUDGET ASSUMPTIONS
/8"/FT.

-1' - 4" ARCH. FOR FINISH MATERIAL) 04 2022.05.27 PROGRESS SET


2X6 @ 16" O.C. LSL STUD WALL 6
05 2022.06.10 PROGRESS SET
UP CONCRETE WALL BELOW
SL O P E 1

S-201 06 2022.06.17 PROGRESS SET


(TYP.)

2 9
S-204

FACETED RIM BOARD (TYP.)


COORDINATE CURVED FINISH
DRAWING INFO
3 FROST WALL BELOW (TYP.)
BUILD-OUT WITH ARCHITECT. CONSTRUCTION DOCUMENTS
S-203 DRAWN BY: Author
CURVED SLAB EDGE CHECKED BY: Checker
OVERHANG VARIES DATE: 05/16/22
SCALE: As indicated
PROJ. NO. Project Number

FIRST FLOOR FRM PLAN

11 S-101
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC

10
RR2
3

4
3
2
2
4 RESIDENCE
1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
5
LINEWEIGHT

T°MᵗRAFPAL4
WHYARETHESE

CURVED PLYWOOD RIDGE


DIFFERENT
LINE WEIGHTS ?
2-2X6 POST IN
MULLION (TYP.) 5 OWNER
BEAM, VAULTED CEILINGS
BELOW
"" """ s FACETED 2- 1 3/4 X 9 1/2
HEADERS (TYP.)
1 6 RR ORCHARD HOLDINGS LLC

9:12
HYP

/
.

FLAT 1347 HOLLOW RD, CLINTON CORNERS, NY 12514


RAFTERS CANTILEVER
FACETED 2- 1 3/4 X 9 1/2 5/8" PLYWOOD
OVER WALLS
HEADER ON (2)-2x6 SHEATHING (TYP.)

g.

9:12
ARCHITECT
3- 13/4×9 'zLVL CANTILEVER HEADER
POSTS (TYP. FOR 9 CEDAR
SPANS > 6'-6") 10A RADIALWALLT :

1 6x6 MM
P.T. POST DOWN

9:12
S-203
6

9:1
SEE ELEVATION MARKUP
S-203 (TYP. @ 2 LOCATIONS)

9:12
2
8 10
WORKSHOP/APD ARCHITECTURE DPC

9:1
RAFTERS PERGOLA,
S-203 S-203 2
9:1

2
BEAR 3X12 EDGES 39 W 38th Street, 7th Fl, New York, NY 10018
ONWALL T: (212) 273-9712 info@workshopapd.com
CURVED EAVE FLAT
" o.c R OO
BUILD-OUT PER 0 @16 F91 2
TJI 23 L /2 TJ SHOW GRAY LINE, 9:1
ARCH. (TYP.) 9 1/2 AX. RADIA
M
5/8"
I 230
@16
" o.c ✓ BELOW JOIST LINES ,
CONTRACTOR

L)
. MA TO INDICATE " OPEN "

IA
X.

ER
CR

AT
STONELEAF CONSTRUCTION

M
4974 Route 22 Amenia, NY 12501

R
"

O
T: (845) 373-8020

.F
CH
AR
9 1/2 TJ
I 230 @1

E
6"
7

SE
o.c. MAX
. RADIAL

.(
STRUCTURAL ENGINEER

.c
2X6 WALL WITH BRICK FLAT

"o
" VENEER (TYP.)

12
16

6@
@
0 IAL MURRAY ENGINEERING
23 AD

2X
I
TJ . R 330 7th Avenue New York, NY 10001
/2 AX 5/8
G

/
1 " T: (212) 741-1102
9 .c M
o CR
5 1/4 X 5 1/4 PSL "
F
POST DOWN 5/8 6x6 POST DOWN
E LANDSCAPE ARCHITECT

2
a)
(TYP. @ ALL (TYP. @ 2 LOCATIONS)

9: 1
RIDGE BEAMS) "" " " "
"ˢ "
JAMES DOYLE DESIGN ASSOCIATES
STRAIGHT (2) - 1 3/4 X 11 7/8 LVL D 125 Greenwich Avenue Greenwich, CT 06830

2
www.y ,

9:1
9 1/
RIDGE SUPPORTING CURVED T: (203) 869-2900
MATCH RAFTERS
8
TO
MASONRY FIREPLACE
C

2 TJ
KNEE WALL UP TO RAFTERS
COORD. W/ ARCH.

I 23
LINEWEIGHT
B SURVEYOR/ CIVIL ENG.

9:12
TO MATCH RAFTERS

0@
2X6 WALL WITH \
A

16"
BRICK VENEER FLAT
\ INSITE ENGINEERING, SURVEY & LANDSCAPE

o.c.
" -¥
LEGEND AND NOTES: ARCHITECTURE, P.C.
9

M
3 Garret Place, Carmel, New York 10512

9:12
AX .
CR
1. CONTRACTOR TO COORDINATE ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECT'S T: (845) 225-9690
DRAWINGS

RAD
"""ERS "
FACETED 3- 1 3/4 X 11 7/8
2. CONTRACTOR TO PROVIDE AND IS RESPONSIBLE FOR ANY SHORING MEASURES REQUIRED. @ "
16 MAX HEADERS, CURVED EAVE

IAL
.

3. ALL FLOOR JOISTS TO BE 14 TJI 230 @ 16" O.C. U.O.N. BUILT OUT (TYP. FOR 3)
4. JOISTS ARE LAID OUT PARALLEL TO ONE RADIAL WALL THEN CUT AT ANGLE AT OTHER AS
SHOWN ON PLAN.
5. WHERE JOISTS RUN PARALLEL TO EXTERIOR WALL, PROVIDE BLOCKING @4'-0" IN THE TWO 3 - 1 3/4 X 16 LVL

6.
END BAYS.
STUD POSTS WITHIN WALLS TO BE 2-2X4/6 (U.O.N) MATCH ARCH
STRAIGHT RIDGE BEAM, 11
LOW, WITH CURVED KNEE
10

4.*
7. DENOTES WOOD POST DOWN U.O.N. MODEL WALL UP TO RAFTERS
8. REPRESENTS WALLS BELOW.
9. 5/8" DENOTES SPAN DIRECTION OF 5/8" PLYWOOD ROOF DECK GLUED AND SCREWED

10. 3/4"
TO THE TOP OF ROOF RAFTERS.
DENOTES SPAN DIRECTION OF 3/4" PLYWOOD FLOOR DECK, GLUED AND SCREWED 7
TO THE TOP OF THE FLOOR JOISTS. W.P. 9 1/2 TJI 230 @16" o.c. MAX.
11. CR DENOTES SPAN DIRECTION FOR MULTI-LAYER CURVED ROOF ASSEMBLY.
ALL DESIGNS & SPECS ARE SUBJECT TO

ROOF KEY PLAN


REFER DETAILS.
10. REFER TO DRAWINGS S-200 FOR GENERAL NOTES, TYPICAL DETAILS, AND SCHEDULES.
COORD. WINDOW WALL 2X6 WALL WITH
3 VERIFICATION OF EXG. FIELD CONDITIONS
11. (U.O.N) DENOTES UNLESS OTHERWISE NOTED.
S-102
:*:*
SYSTEM WITH ARCH. BRICK VENEER 1/16" = 1'-0"
12. CONTRACTOR TO COORDINATE WITH MECHANICAL DRAWINGS FOR ANY PENETRATIONS
THROUGH CONCRETE SLABS/WALLS. REVISIONS

SECOND FLOOR / LOW ROOF FRAMING PLAN

:::::
1 5/8

WN
"
S-102

DO
1/8" = 1'-0" HSS3 1/2x3 1/2x1/4 DN.
STEEL FRAME TO

ES
(TYP. @ 2 LOCATIONS) 1
G SUPPORT RIDGE BEAM

P
LO
ABOVE (SEE ELEVATION) S-303
SHEAR WALL DN.

S
:*. LL 2X6 WALL WITH
WA
+10' - 9 1/2"
POSTS SUPPORTING RIDGE BEAMS F WOOD CLADDING STEEL FRAME TO NOT FOR CONSTRUCTION
ARE -10135-544×5 "4PSLU -0 .N .
SUPPORT RIDGE 2-1 3/4x9 1/2 LVL

E
"
CUT DOWN -10912 @ CANTILEVER BEAM ABOVE. HEADER(LOW/TYP.)
RIDGE POSTS LESS THAN 81=-1 HIGH 2 (TYP BOTH SIDES ) SEE ELEVATION
3/4 .

"⇐ ① "
⇐ £""
BEARING WALL " S-303
1 3×12 PULLED OUTSIDE
BELOW
'
SHEAR WALL DN. BALCONY
S-303
/
14
T
,

35
JI SHEAR WALL UP
36 CEDAR COORDINATE

2X

D " 0@
(3)

W1
2X6 WALL WITH 16 3x POST DOWN CHIMNEY WITH ARCH.
WALL BELOW 4 " "o RIDGE POST UP 1 2 1 5/8
BRICK VENEER .c. (TYP. 2 LOC.) 3/4 "

L
x1
"

LV
(TYP.) S-204 MA 4L 2X6 WALL WITH WOOD

L
X. VL

1/2
.c
EXTERIOR WALL

LV
CLADING BELOW
C

"o
RID

L
" 5

LV
x9
14
FINISH PER G

16
" EB

3/4
/4x

1/2
ARCH.(TYP.) S-202 91

@
EA

L
a -¥
LV
13
/2
B

1
M

x9
60
6 8 TJ 2

(2)
14

3/4
3.1 I

I3
(2)
23
8

/4x
S-204 25 0

TJ
S-204 S-303

1
x1 @

13
2

(2)
A 16

14
5/8"

E
CR
G 7 1/4x5 1/4 PSL

AC
" o.c

(2)

SP
. POST DOWN

L
5/8 MA (3) SIGN & SEAL

LV
12
X X. 1
MA

R
PO " 3/4

3x

1/2
OO
o.c (TY ST x1

L
" P. DO 4L
ISSUES

LV
FL

x9
16 2 L WN VL

3/4
0@

1/2
5

ND
OC RID
I2
3
F GE 01 2021.10.21 CORE AND SHELL PRICING SET

1
CO
.)

x9
TJ S-204

(2)
/2 3x BE

3/4
02 2022.04.25 UPDATED FLOOR PLANS

SE
91 1 2 AM
a-

1
7 03 2022.05.02 INT. BUDGET ASSUMPTIONS
STEEL FRAME TO

(2)
÷:¥¥¥
04 2022.05.27 PROGRESS SET
PREFABRICAT STEEL FRAME TO BELOW JOIST LINES ,
E S-204 SUPPORT RIDGE
BEAM ABOVE.
8 05 2022.06.10 PROGRESS SET
ED TRUSSES SUPPORT RIDGE .
06 2022.06.17 PROGRESS SET
@ 24" o.c. M SEE ELEVATION.
AX. BEAM ABOVE
SEE ELEVATION
9 8
SHEAR WALL DN.

2-2X6 POST IN
MULLION (TYP.) D S-204

FACETED 2- 1 3/4 X 9 1/2


DRAWING INFO
HEADERS, CURVED EAVE
BUILD-OUT (TYP.)
C CONSTRUCTION DOCUMENTS
DRAWN BY: Author
CHECKED BY: Checker
DATE: 05/18/22

B 9 SCALE:
PROJ. NO.
As indicated
Project Number

(2) 1 3/4"x14" LVL (LOW) CURVED EAVE


GARAGE DOOR HEADER BUILD-OUT PER ARCH. SECOND FLR / ROOF FRM
(TYP.) (TYP.) A
PLAN
11 10
2 HIGH ROOF FRAMING PLAN S-102
S-102 1/8" = 1'-0"
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
RR2
GENERAL SLAB ON GRADE NOTES:
1. REMOVE ANY EXISTING FILL BELOW NEW SLABS THAT IS UNSUITABLE
FOR BEARING & REPLACE WITH CONTROLLED COMPACTED BACKFILL
AS DIRECTED BY GEOTECH ENGINEER.
2. INSTALL BACKFILL IN 8" LIFTS & COMPACT TO 95% RELATIVE PROCTOR
DENSITY PER ASTM D1557.
3. COORDINATE INSULATION AND WATERPROOFING REQUIREMENTS

RESIDENCE
4" SLAB TYPICAL 6x6/W2.0xW2.0 W.W.F. WITH ARCHITECT.
5" @ GARAGE CONTROL SCORE JOINT / SAW CUT JOINT 4. EXTERIOR SLABS ON GRADE TO BE SLOPED TO DRAIN.
1/8" WIDE. CUT WITHIN 24 HOURS OF SLAB COORDINATE DRAINAGE REQUIREMENTS WITH ARCHITECT. PROVIDE EXPANSION JOINT

1 1/2" @ 5" SLAB


SLAB ON GRADE. SEE

1" @ 4" SLAB


PLAN FOR ADD'L INFO POUR USE "SOFCUT" SAW AND FILL JOINT TO ADJOINING STRUCTURES
#4 CONT. AROUND PERIMETER
WITH JOINT FILLER 1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
PROVIDE CHAIR TO #4 BAR AT CORNERS
SUPPORT REINFORCEMENT 10" 2"x3" KEY ACI STND. ACI STND.
HOOK (TYP) HOOK (TYP). 2' - 0"
OWNER
2"

30 BAR DIAM. 30 BAR DIAM.

10"
.

RR ORCHARD HOLDINGS LLC


1347 HOLLOW RD, CLINTON CORNERS, NY 12514

4"
.

(2)-#5
MIN .
6 " OF 34
"
CONT. ARCHITECT
4"
mm OF CLEAN CRUSHED NOTE: NOTE:
1' - 0" CONT. WATER STOP
STONE AGGREGATE OR 1. CONTROL JOINT IS TO BE CUT WHILE 1. CONTRACTOR SHALL COORDINATE

0"
SAND, COMPACTED PER CONCRETE IS STILL IN IT'S PLASTIC CONSTRUCTION JOINT LOCATIONS U-BARS SIZED AND SPACED TO KEY WORKSHOP/APD ARCHITECTURE DPC
ACI RECOMMENDATIONS STATE, MAXIMUM 8 HOURS AFTER WITH ENGINEER PRIOR TO CASTING MATCH HORIZ. WALL REINF.
1" DEEP CONTROL JOINT. 39 W 38th Street, 7th Fl, New York, NY 10018
PLACEMENT. SLAB.
2-#5(ADD'L) FOR W>12" T: (212) 273-9712 info@workshopapd.com
VAPOR BARRIER 2. CONTRACTOR SHALL COORDINATE 2" CLEAR (TYP)
(COORDINATE WITH ARCH.) CONTROL JOINTS LOCATIONS WITH 1-#5 (ADD'L) FOR W<12"
DOWELS SAME SIZE
ENGINEER PRIOR TO CASTING SLAB.
AND SPACING OF
HORIZ. WALL BARS. CONTRACTOR
TYPICAL SLAB CONTROL JOINT CONST. JOINT CONCRETE PAD TYPICAL HAUNCH STONELEAF CONSTRUCTION
AT EDGES OF SLAB CORNER INTERSECTION EDGE OF OPENING CONST. JOINT 4974 Route 22 Amenia, NY 12501
T: (845) 373-8020

8 TYPICAL SLAB ON GRADE DETAILS 9 TYPICAL CONCRETE WALL DETAILS STRUCTURAL ENGINEER
S-201 3/4" = 1'-0"
S-201 3/4" = 1'-0"
NOTE :
( COPY # 1 FROM 5-100) MURRAY ENGINEERING
330 7th Avenue New York, NY 10001
T: (212) 741-1102
2-#4 BARS #4 NOSING BAR
INTERRUPTED BARS
#4@16" o.c. EACH WAY
1' - 4"
LANDSCAPE ARCHITECT
2.0 Ld PAST OPENING

REFER ARCH. DWGS. JAMES DOYLE DESIGN ASSOCIATES


FOR RISER/TREAD 125 Greenwich Avenue Greenwich, CT 06830
LAYOUT AND FINISH T: (203) 869-2900
2.0 Ld PAST OPENING
4"
PROVIDE ADDITIONAL 1' -
2-#4x4'-0" @ EACH PAINT CORNER
CORNER OF OPENING CONC. WALLS WITH BOND BREAKER SURVEYOR/ CIVIL ENG.
INTERRUPTE
D BARS INSITE ENGINEERING, SURVEY & LANDSCAPE
INTERRUPTED BARS ARCHITECTURE, P.C.
3 Garret Place, Carmel, New York 10512

S.O.G. REINF. @ RE-ENTRANT CORNERS


T: (845) 225-9690

3"
7

CO
VE
S-201 1/2" = 1'-0"

R
6"
(M
IN.
2.0 Ld PAST OPENING

)
2.0 Ld PAST OPENING

3' - 0"
8" FOUNDATION
.)
CONCRETE WALL
2' - 0" (MIN.) 0" (MIN
2' -
PROVIDE
ADDITIONAL 1' - 3" MIN. ALL DESIGNS & SPECS ARE SUBJECT TO
BAR FOR EVERY #4@16" o.c. EACH WAY VERIFICATION OF EXG. FIELD CONDITIONS
INTERRUPTED BARS INTERRUPTED WALL REINF. BARS
BAR
REVISIONS

3"
TENSION SPLICE
SINGLE OPENING NOTES: (2)-#4 BOT. BARS
(*) ADD AT LEAST 1/2 TOTAL NUMBER OF BARS @ EACH SIDE OF OPENING, SAME
AS INTERUPTED BARS. MINIMUM 1 #4 TOP & BOTTOM EACH SIDE.

3'-0". MAX.
2' - 0" (MIN.)
GENERAL NOTES:

1. MAX. 12" WIDE NOTIFY MURRAY ENGINEER IF LARGER OPENING IS NEEDED. 1' - 6" MIN. 6 TYPICAL EXTERIOR STAIR DETAIL
2. HOOK ALL INTERRUPTED BARS. S-201 1" = 1'-0"
FTG.

3. OMIT ADDED BARS IF STANDARD BAR SPACING CAN BE PLACED ON EITHER FOOTING REINFORCEMENT
SIDE OF THE OPENING.
1
4. WHERE OPENINGS ARE NEAR OR AGAINST EXTERIOR BEAMS OR COLUMNS
AND ADDED REINFORCEMENT CANNOT BE EXTENDED TO 2.0 Ld, ADDED
NOT FOR CONSTRUCTION
8" (MIN.) 1.5
BARS TO BE HOOKED.

4 REINF. @ FNDN. WALL OPNG. 5 TYPICAL STEPPED FOOTING DETAIL 1' - 2"

S-201 1/2" = 1'-0"


S-201 3/4" = 1'-0"

LVL BEAM (2) LAYERS 3/4" PLYWOOD


REFER PLAN. FLOOR DECK

T.O. EXTERIOR SHELF


REFER PLAN
TJI JOISTS

8"/10" CONCRETE WALL.


1 2 3 4 5 6 10 11 -3'-9"
SEE PLAN
7 -3'-2"
2'-0" (TYP.)

2-#4 BARS (TYP.)


SIGN & SEAL
8 9 NO LEDGE

JOIST HANGER
ISSUES
01 2021.10.21 CORE AND SHELL PRICING SET
REFER SCHEDULE
02 2022.04.25 UPDATED FLOOR PLANS
LCC5.25-4 POST CAP 03 2022.05.02 INT. BUDGET ASSUMPTIONS
8"X8"X3/4" BASE PLATE ON MIN. BY SIMPSON STRONG-TIE 04 2022.05.27 PROGRESS SET
3/4" N.S. LEVELING GROUT 05 2022.06.10 PROGRESS SET
FACE OF
PROVIDE 4 - 5/8" ANCHOR BOLTS PIPE POST. SEE PLAN 06 2022.06.17 PROGRESS SET
CONCRETE
WALL BELOW
FILL POCKET SOLID WITH N.S.
GROUT AFTER COLUMN PROVIDE 1/2" CONTROL JOINT
INSTALLATION COMPRESSABLE MEMBRANE (TYP.)
ALL ROUND POCKET
NOTE: REFER TO ARCH. FOR
BASEMENT
NON-SHRINK GROUT INFILL T.O. STEM WALL ASSEMBLY FINISH DRAWING INFO
CONSTRUCTION DOCUMENTS
DRAWN BY: Author
1/2" COMPRESSIBLE MEMBRANE ALL AROUND 1 2 3 4 5 6 10 -2'-9" T.O.INTERIOR CHECKED BY: Checker
SHELF -1'-8" @ 11 ONLY DATE: 05/26/22
7 -2'-2"
SCALE: As indicated
8 9 -1'-7" PROJ. NO. Project Number

11 -0'-9"
TYP. CONC. DETAILS
3" COVER

SEE PLAN FOR FOOTING 4" 6"

1 SECTION
SIZE AND REINFORCEMENT

2 S.O.G. DETAIL @ COLUMNS 3 CONCRETE WALL PLAN DETAIL S-201


S-201 3/4" = 1'-0"
S-201 3/4" = 1'-0"
S-201 1 1/2" = 1'-0"
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
NO FIELD
CUT HOLES
IN HATCHED
ZONES
MINIMUM DISTANCE
FROM TABLE A
MINIMUM DISTANCE
FROM TABLE A 1 1/2" HOLE MAY BE
CUT ANYWHERE IN
WEB OUTSIDE OF
HATCHED ZONE
FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
DESCRIPTION OF BUILDING ELEMENTS
JOIST TO SILL OR GIRDER, TOE NAIL
SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL
NUMBER AND TYPE
OF FASTENER
3 - 8d
16d
SPACING OF
FASTENERS
___
16" O.C.
RR2
RESIDENCE
TOP OR SOLE PLATE TO STUD, END NAIL 2 -16d ___
STUD TO SOLE PLATE, TOE NAIL 3 - 8d OR 2 - 16d ___
1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
DOUBLE STUDS, FACE NAIL 10d 24" O.C.
HOLES ARE TO BE DOUBLE TOP PLATES, FACE NAIL 10d 24" O.C.

6"
6"
6"
L1 D1 L2
2 X L2
D2
6" 6" CENTERED ON HEIGHT
OF JOIST ONLY
SOLE PLATE TO JOIST OR BLOCKING AT BRACED WALL PANELS
DOUBLE TOP PLATES, MINIMUM 48" OFFSET OF END
3 -16d 16" O.C.
___
OWNER
MIN. 8 - 16d
JOINTS, FACE NAIL IN LAPPED AREA RR ORCHARD HOLDINGS LLC
2 X D1 MINIMUM DO NOT CUT HOLED LARGER
BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOE NAIL 3 - 8d ___ 1347 HOLLOW RD, CLINTON CORNERS, NY 12514
(APPLIED TO ALL HOLES THAN 1 1/2" IN CANTILEVER
EXCEPT KNOCKOUTS) RIM JOIST TO TOP PLATE, TOE NAIL 8d 6" O.C.
TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS, FACE NAIL 2 -10d ___
BUILT-UP HEADER, TWO PIECES WITH 1/2" SPACER 16d 16" O.C. ALONG EACH EDGE ARCHITECT
CONTINUED HEADER, TWO PIECES 16d 16" O.C. ALONG EACH EDGE
PLYWOOD SHEATHING ___
TABLE A - END SUPPORT SIMPSON CEILING JOISTS TO PLATE, TOE NAIL 3 - 8d

]
CONTINUOUS HEADER TO STUD, TOE NAIL 4 - 8d ___
MINIMUM DISTANCE FROM EDGE OF HOLE TO INSIDE FACE OF NEAREST END SUPPORT HOL DOWN WOOD SHEAR WALL WORKSHOP/APD ARCHITECTURE DPC
CEILING JOIST, LAPS OVER PARTITIONS, FACE NAIL 3 - 10d ___ 39 W 38th Street, 7th Fl, New York, NY 10018
ROUND HOLE SIZE SQUARE OR RECTANGULAR HOLE SIZE BOTTOM PLATE CEILING JOIST TO PARALLEL RAFTERS, FACE NAIL 3 - 10d ___ T: (212) 273-9712 info@workshopapd.com
DEPTH TJI ___
2" 3" 4" 5" 6 1/2" 7" 8 1/2" 11" 2" 3" 4" 5" 6 1/2" 7" 8 1/2" 11" RAFTER TO PLATE, TOE NAIL 2 -16d
11 7/8" 210 1'-0" 1'-0" 1'-0" 1'-6" 2'-6" 3'-0" 5'-6" 1'-0" 1'-0" 2'-0" 3'-0" 5'-0" 5'-6" 6'-6" PLYWOOD FLOOR DECK 1" BRACE TO EACH STUD AND PLATE, FACE NAIL ___
2 - 8d
___
14 360 1'-0" 1'-0" 1'-0" 1'-6" 2'-6" 3'-0" 5'-6" 8'-0" 1'-0" 1'-0" 1'-0" 2'-6" 5'-6" 5'-6" 8'-0" 9'-6"
SECOND FLOOR
2 STAPLES, 1 3/4"
24" O.C.
CONTRACTOR
+10' - 10 1/4" BUILT-UP CORNER STUDS 10d
TABLE B - INTERMEDIATE OR CANTILEVER SUPPORT BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS NAIL EACH LAYER AS STONELEAF CONSTRUCTION
MINIMUM DISTANCE FROM EDGE OF HOLE TO INSIDE FACE OF NEAREST INTERMEDIATE OR CANTILEVER SUPPORT 4974 Route 22 Amenia, NY 12501
FOLLOWS: 32" O.C. AT TOP
10d AND BOTTOM AND T: (845) 373-8020
ROUND HOLE SIZE SQUARE OR RECTANGULAR HOLE SIZE
DEPTH TJI STAGGERED. TWO NAILS AT
2" 3" 4" 5" 6 1/2" 7" 8 1/2" 11" 2" 3" 4" 5" 6 1/2" 7" 8 1/2" 11"
ENDS AND AT EACH SPLICE.
11 7/8" 210 1'-0" 1'-0" 2'-0" 3'-0" 4'-6" 5'-0" 9'-0" 1'-0" 2'-0" 3'-0" 4'-6" 7'-6" 8'-0" 10'-0"
ROOF RAFTERS TO RIDGE, VALLEY OR HIP RAFTERS:
14 360 1'-0" 1'-0" 2'-0" 3'-6" 5'-6" 6'-0" 8'-6" 12'-6" 1'-0" 2'-0" 4'-0" 5'-6" 9'-0" 10'-0" 12'-0" 14'-0" TOE NAIL 4 - 16d ___ STRUCTURAL ENGINEER
NOTES: FACE NAIL 3 - 16d ___
2x8 NAILER MURRAY ENGINEERING
1. HOLES MAY BE LOCATED VERTICALLY ANYWHERE WITHIN THE WEB. LEAVE 1⁄8" OF WEB (MINIMUM) AT TOP AND BOTTOM OF HOLE. RAFTER TIES TO RAFTERS, FACE 3 - 8d ___
2. KNOCKOUTS ARE LOCATED IN WEB AT APPROXIMATELY 12" ON-CENTER; THEY DO NOT AFFECT HOLE PLACEMENT. 330 7th Avenue New York, NY 10001
WOOD STRUCTURAL PANELS, SUBFLOOR, ROOF AND WALL 6 -10d COMMON NAIL OR 12" T: (212) 741-1102
3. FOR SIMPLE SPAN (5' MINIMUM) UNIFORMLY LOADED JOISTS MEETING THE REQUIREMENTS OF THIS GUIDE, ONE MAXIMUM SIZE STEEL BEAM.
SHEATHING TO FRAMING, AND PARTICLEBOARD WALL 6 - 8d DEFORMED NAIL
ROUND HOLE MAY BE LOCATED AT THE CENTER OF THE JOIST SPAN PROVIDED THAT NO OTHER HOLES OCCUR IN THE JOIST. REFER PLAN.
SHEATHING TO FRAMING
4. DISTANCES ARE BASED ON THE MAXIMUM UNIFORM LOADS SHOWN IN THIS GUIDE. FOR OTHER LOAD CONDITIONS OR HOLE
CONFIGURATIONS, USE TJ-BEAM® SOFTWARE OR CONTACT YOUR ILEVEL REPRESENTATIVE. TJI JOISTS. 1/2" GYPSUM WALL SHEATHING 1 1/2" GALVANIZED ROOFING 4" AT EDGE; 8" AT
REFER PLAN. NAIL; 6d COMMON NAIL; INTERMEDIATE SUPPORTS LANDSCAPE ARCHITECT
STAPLE GALVANIZED, 1 1/2"
LONG; 1 1/4" SCREWS, JAMES DOYLE DESIGN ASSOCIATES

ALLOWABLE HOLES FOR TJI DETAILS SECTION


TYPE W OR S 125 Greenwich Avenue Greenwich, CT 06830
3 5 5/8" GYPSUM WALL SHEATHING 1 3/4" GALVANIZED ROOFING 4" AT EDGE; 8" AT
T: (203) 869-2900
NAIL; 8d COMMON NAIL; INTERMEDIATE SUPPORTS
S-202 3/4" = 1'-0"
S-202 1" = 1'-0"
STAPLE GALVANIZED, 1 5/8"
LONG; 1 5/8" SCREWS,
TYPE W OR S
SURVEYOR/ CIVIL ENG.
2 X THE DIAMETER OR LENGTH WOOD STRUCTURAL PANELS, COMBINATION 6d DEFORMED NAIL 6" AT EDGE; 12" AT INSITE ENGINEERING, SURVEY & LANDSCAPE
OF HE LARGEST HOLE (MIN.) SUBLFOOR UNDERLAYMENT TO FRAMING (3/4" AND LESS) OR 8d COMMON NAIL INTERMEDIATE SUPPORTS
1/3 DEPTH

ARCHITECTURE, P.C.
1/3 DEPTH

3 Garret Place, Carmel, New York 10512


ACCEPTABLE AREA FOR FIELD NOTES:
T: (845) 225-9690
CUTTING OF PLUMBING HOLES 1. REFER TO TABLE R602.3(1) OF THE RESIDENTIAL CODE OF NEW YORK FOR ADDITIONAL INFORMATION.
2. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER INFORMATION SHOWN IN THIS TABLE.

3" OR 3" SQUARE HOLE (MAX.). CONTRACTOR TO


1/3 DEPTH

COORDINATE WITH ENGINEER FOR REINFORCING FRAMING CONNECTORS SCHEDULE (MANUFACTURED BY FRAMING CONNECTORS SCHEDULE
REQUIREMENTS AT LARGER PENETRATIONS PRIOR TO SIMPSON STRONG-TIE)
(MANUFACTURED BY SIMPSON STRONG-TIE)
FIELD CUTTING
PERIMETED HOLE ZONE
1/3 SPAN 1/3 SPAN
1/3" SPAN SINGLE JOIST - SINGLE JOIST -
TOP FLANGE
TOP FLANGE FACE MOUNT
ALL DESIGNS & SPECS ARE SUBJECT TO
VERIFICATION OF EXG. FIELD CONDITIONS
CAPACITY NAILING CAPACITY NAILING MEMBER MEMBER CAPACITY NAILING
DEPTH TJI HANGER HANGER HANGER
(LBS) HEADER JOIST (LBS) HEADER JOIST WIDTH DEPTH (LBS) HEADER JOIST

9 1/2"
110 ITS1.81/9.5 1,365 10d N.A. IUS1.81/9.5 935 10d N.A.
9 1/4"
WPU1.81/9.25 3,650 16d 10d x 1 1/2"
REVISIONS
4 ALLOWABLE HOLES FOR LVL DETAILS 210
230
ITS2.06/9.5
ITS2.37/9.5
1,365
1,365
10d
10d
N.A.
N.A.
IUS2.06/9.5
IUS2.37/9.5
935
935
10d
10d
N.A.
N.A.
9 1/2"
LBV1.81/9.25
MIT9.5
2,885
2,115
16d
16d
10d x 1 1/2"
10d x 1 1/2"
S-202 3/4" = 1'-0" 110
210
ITS1.81/11.88
ITS2.06/11.88
1,365
1,365
10d
10d
N.A.
N.A.
IUS1.81/11.88
IUS2.06/11.88
1,170
1,170
10d
10d
N.A.
N.A. 1 3/4"
LBV1.81/9.5
WPU1.81/11.25
2,885
3,650
16d
16d
10d x 1 1/2"
10d x 1 1/2"
11 1/4"
230 ITS2.37/11.88 1,365 10d N.A. IUS2.37/11.88 1,170 10d N.A. LBV1.81/11.25 2,885 16d 10d x 1 1/2"
11 7/8"
360 ITS2.37/11.88 1,365 10d N.A. IUS2.37/11.88 1,170 10d N.A. MIT11.88 2,115 16d 10d x 1 1/2"
11 7/8"
560 ITT411.88 1,300 10d 10d x 1 1/2" IUS3.56/11.88 1,405 10d N.A. BA1.81/11.88 3,705 16d 10d x 1 1/2"
MULTIPLE-MEMEBER CONNECTIONS 110 ITS1.81/14 1,365 10d N.A. IUS1.81/14 1,405 10d N.A. 14" B1.81/14 3,355 16d 10d x 1 1/2"
210 ITS2.06/14 1,365 10d N.A. IUS2.06/14 1,405 10d N.A. 9 1/4" HB3.56/9.25 5,640 16d 16d
CONNECTOR PATTERN
NOTE: 14"
230 ITS2.37/14 1,365 10d N.A. IUS2.37/14 1,405 10d N.A. 9 1/2" HB3.56/9.5 5,640 16d 16d NOT FOR CONSTRUCTION
ASSEMBLY A ASSEMBLY B ASSEMBLY F (1) 6" SDS OR SW SCREWS CAN BE USED WITH 360 ITS2.37/14 1,365 10d N.A. IUS2.37/14 1,405 10d N.A. 11 1/4" HB3.56/11.25 5,640 16d 16d
PARALLAM PSL AND MICROLLAM LVL, BUT ARE NOT 560 ITT414 1,300 10d 10d x 1 1/2" IUS3.56/14 1,405 10d N.A. 3 1/2" 11 7/8" HB3.56/11.88 5,640 16d 16d
RECOMMENDED FOR TIMBERSTRAND LSL. 14" GLTV3.514 5,750 16d 16d
(2) 3 1/2" AND 3 5/8" LONG SCREWS MUST BE DOUBLE JOIST - DOUBLE JOIST - 16" GLTV3.516 5,750 16d 16d
INSTALLED ON BOTH SIDES. TOP FLANGE FACE MOUNT
(3) 6" LONG SCREWS REQUIRED. 18" HGLTV3.518 9,000 16d 16d
(4) 5" LONG SCREWS REQUIRED. 9 1/4" GLTV5.50/9.25 5,750 16d 16d
CAPACITY NAILING CAPACITY NAILING 9 1/2" GLTV5.59 5,750 16d 16d
(5) BOLTS ARE TO BE MATERIAL CONFORMING TO DEPTH TJI HANGER HANGER
ASTM STANDARD A307 (MACHINE BOLTS). BOLT (LBS) HEADER JOIST (LBS) HEADER JOIST 11 1/4" GLTV5.50/11.25 5,750 16d 16d
1 3/4" 1 3/4" 1 3/4" HOLES ARE TO BE THE SAME DIAMETER AS THE 110 MIT49.5 2,115 16d 10d x 1 1/2" MIU3.56/9 2,270 16d 10d x 1 1/2"
9 1/2" 5 1/4" 11 7/8" HGLTV5.511 9,000 16d 16d
BOLT AND LOCATED 2" FROM THE TOP AND 210 MIT4.28/9.5 2,115 16d 10d x 1 1/2" MIU4.28/9 2,270 16d 10d x 1 1/2" 14" EGQ5.50-SDS3 18,680 SDS 1/4" x 3" SDS 1/4" x 3"
BOTTOM OF THE MEMBER. WASHERS SHOULD BE 230 MIT359.5-2 2,115 16d 10d x 1 1/2" MIU4.75/9 2,270 16d 10d x 1 1/2"
3 1/2" 5 1/4" 7" USED UNDER HEAD AND NUT. 16" EGQ5.50-SDS3 18,680 SDS 1/4" x 3" SDS 1/4" x 3"
2-PLY 3 - PLY 4 - PLY 110 MIT411.88 2,115 16d 10d x 1 1/2" MIU3.56/11 2,840 16d 10d x 1 1/2" 18" EGQ5.50-SDS3 18,680 SDS 1/4" x 3" SDS 1/4" x 3"
210 MIT4.28/11.88 2,115 16d 10d x 1 1/2" MIU4.28/11 2,840 16d 10d x 1 1/2"
10d (0.128"x3") NAIL 10d (0.128"x3") NAIL SDS SCREWS 1/4" X 3 230 MIT3511.88-2 2,115 16d 10d x 1 1/2" MIU4.75/11 2,840 16d 10d x 1 1/2"
1/2" @12" o.c. 11 7/8" FACE MOUNT
@ 12" o.c. @ 12" o.c. 360 MIT3511.88-2 2,115 16d 10d x 1 1/2" MIU4.75/11 2,840 16d 10d x 1 1/2" SIGN & SEAL
560 B7.12/11.88* 3,355 16d 16d HU412-2* 2,145 16d 16d
110 MIT414 2,115 16d 10d x 1 1/2" MIU3.56/14 3,125 16d 10d x 1 1/2"
210 MIT4.28/14 2,115 16d 10d x 1 1/2" MIU4.28/14 3,125 16d 10d x 1 1/2"
MEMBER MEMBER
HANGER
CAPACITY NAILING ISSUES
WIDTH DEPTH (LBS) HEADER JOIST 01 2021.10.21 CORE AND SHELL PRICING SET
230 MIT3514-2 2,115 16d 10d x 1 1/2" MIU4.75/14 3,125 16d 10d x 1 1/2" 7 1/4"-9 1/2" HU7 1,610* 16d 10d x 1 1/2"
14" 02 2022.04.25 UPDATED FLOOR PLANS
4 0R 6 SCREW 8 SCREW
360 MIT3514-2 2,115 16d 10d x 1 1/2" MIU4.75/14 3,125 16d 10d x 1 1/2" 1 3/4" HU11 2,950* 16d 10d x 1 1/2"
NAIL CONNECTION 4 BOLT 03 2022.05.02 INT. BUDGET ASSUMPTIONS
CONNECTION CONNECTION 560 B7.12/14* 3,355 16d 16d HU414-2* 2,680 16d 16d 11 1/4"-14"
CONNECTION HUS1.81/10 4,900 16d 16d 04 2022.05.27 PROGRESS SET
7 1/4"-11 1/2" HHUS48 3,885 16d 16d 05 2022.06.10 PROGRESS SET
10D (0.128"X3")NAILS, VARIABLE SLOPE NOTES:
TYPICAL STAGGER TO 1. * INDICATED HANGER REQUIRE HHUS410 5,190 16d 16d 06 2022.06.17 PROGRESS SET
SEAT JOIST 3 1/2" 9 1/2"-18"
PREVENT SPLITTING WEB STIFFENERS. HGUS410 8,780 16d 16d
HANGER
SDS OR TRUSSLOK SDS OR TRUSSLOK HANGER AS 2. LEAVE 1/16" CLEARANCE (1/8" 14"-20" HGUS414 10,015 16d 16d
SCREW, TYPICAL SCREW, TYPICAL SPECIFIED CAPACITY MAXIMUM) BETWEEN THE END OF THE 9 1/4"-11 7/8" HHUS5.50/10 5,190 16d 16d
NAILING
2" SPACING, TYPICAL (LBS) SUPPORTED JOIST AND THE HEADER 11 1/4"-14" HHUS5.50/12 9,155 16d 16d
TJI HANGER 5 1/4"
SLOPE OR HANGER. HHUS5.50/14 10,015 16d 16d
2", TYPICAL 2", TYPICAL HEADER JOIST 14"-20"
TOP AND TOP AND 2", TYPICAL
2", TYPICAL
TOP AND
ONLY HHU5.50 14,145 SDS 1/4"x2 1/2" SDS 1/4"x2 1/2"
DRAWING INFO
BOTTOM BOTTOM TOP AND BOTTOM 110 LSSUI25* 1,110 10d 10d x 1 1/2" NOTES:
CONSTRUCTION DOCUMENTS
BOTTOM 210 LSSU2.1* 1,110 10d 10d x 1 1/2" 1. HANGER CAPACITY MAY BE MORE OR LESS THAN THAT OF THE
DRAWN BY: Author
230 LSSUI35* 1,110 10d 10d x 1 1/2" SUPPORTED MEMBER; THEREFORE, CHECK BOTH THE HANGER CHECKED BY: Checker
360 LSSUI35* 1,110 10d 10d x 1 1/2" AND THE BEAM CAPACITIES. DATE: 05/26/22
PROVIDE 2 THROUGH BOLTS EACH 2. LEAVE 1/16" CLEARANCE (1/8" MAXIMUM) BETWEEN THE END OF
560 LSSU410* 2,430 16d 10d x 1 1/2" SCALE: As indicated
SIDE WHEREEVER A CONCENTRATED THE BEAM OR HEADER AND ITS SUPPORT MEMBER OR HANGER.
1 1/2 MINIMUM PROJ. NO. Project Number
EQUAL SPACING LOAD IS APPLIED TO MULTIPLY LVL
1/2 BEAM DEPTH SPACING, TYPICAL 3. REFER TO MANUFACTURER FOR ADDITIONAL INFORMATION.
BEAM. COORDINATE HANGER SIZE
4. * VALUE MAY BE INCREASED FOR DURATION OF LOAD.
THERE MUST BE AN EQUAL NUMBER OF
NAILS ON EACH SIDE OF THE CONNECTION
AND BOLT PATTERN WITH ENGINEER
TYP. WOOD DETAILS

1 TYPICAL POINT LOAD CONNECTION S-202


S-202 3/4" = 1'-0"
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
COORDINATE ROOFING
WITH ARCHITECT
.MN DRAWINGS COORDINATE ROOFING
WITH ARCHITECT
.MN DRAWINGS
/ NATE

COORD.Y ROOFING W/ ARCHITECT


.MU DRAWINGS

5/8" CDX PLYWOOD SHEATHING


INATE ITH

COORD. ROOFING W/Ñ ARCHITECT


Y

TJI RAFTER (REFER PLAN)


.MN

5/8" CDX PLYWOOD SHEATHING


DRAWINGS

RR2
RESIDENCE
1/2" CDX PLYWOOD
1/2" CDX PLYWOOD SHEATHING TJI RAFTER (REFER PLAN)
SHEATHING 12
REFRER TO 1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
REFRER TO 12 PLYWOOD CONTINUOUS
2ND LAYER 2X4 6/S-204 FOR 2ND LAYER 2X4 NAILERS 9
6/S-204 FOR TO EXTERIOR
NAILERS 9 CURVED
CURVED
ROOF 1ST LAYER 2X4 ROOF
ASSEMBLY
1ST LAYER 2X4 NAILERS
OWNER
NAILERS LSL BLOCKING
ASSEMBLY TJI RAFTERS (REFER PLAN)
BETWEEN RAFTERS
TJI RAFTERS GRAY
RR ORCHARD HOLDINGS LLC
(REFER PLAN) LIKE LSL BLOCKING 1347 HOLLOW RD, CLINTON CORNERS, NY 12514

EXTRA
815-203
] LVL HEADER
CONT. DOUBLE
REFER PLAN
ARCHITECT
EXTRA LINE?
LINE? TOP PLATE

#
°

-§0
LSL BLOCKING LVL HEADER (FLUSH) 2x6 STUD WALL
REFER PLAN
go
GRAY WORKSHOP/APD ARCHITECTURE DPC
GRAY 1/2" CDX PLYWOOD 39 W 38th Street, 7th Fl, New York, NY 10018
WINDOW JOIST HANGER CONNECTION (TYP.) T: (212) 273-9712 info@workshopapd.com
CONT. DOUBLE TOP PLATE SHEATHING
REFER SCHEDULE
CONT. DOUBLE TOP PLATE JOIST HANGER BY COORD. FINISH W/ ARCH.
SIMPSON STRONG-TIE
2X6 STUD WALL
WINDOW REFER SCHEDULE
1/2" CDX PLYWOOD CONTRACTOR
WALL SHEATHING
STONELEAF CONSTRUCTION
4974 Route 22 Amenia, NY 12501

DETAIL
T: (845) 373-8020
10A
8 TYPICAL SECTION @ BEARING WALL 9 TYPICAL SECTION @ HEADER 10 DETAIL S-203 1" = 1'-0"

STRUCTURAL ENGINEER
S-203 3/4" = 1'-0"
S-203 3/4" = 1'-0"
S-203 1" = 1'-0"
MURRAY ENGINEERING
51M .

6/1-1-602 330 7th Avenue New York, NY 10001


REF 2 / A- 602.
REF . 411-1-602 REF .

6/1-1-602 T: (212) 741-1102

LANDSCAPE ARCHITECT
TJI JOIST (REFER PLAN.) JAMES DOYLE DESIGN ASSOCIATES
125 Greenwich Avenue Greenwich, CT 06830
YAX T: (203) 869-2900
.

TJI JOIST (REFER PLAN) 1 1/2" CONCRETE MICRO-TOPPING


YAX
.

www.h
FLOOR FINISH. COORD. W/ ARCH.
my
1 1/2" CONCRETE MICRO-
2X6 STUD WALL TOPPING FLOOR FINISH
MM
MM%0ORDINATE COORDINATE
SURVEYOR/ CIVIL ENG.
WITH ARCH
WITH ARCH 2 LAYERS 3/4" PLYWOOD
.

2 LAYERS 3/4" PLYWOOD SUB FLOOR DRAWINGS


1/2" CDX PLYWOOD DRAWINGS INSITE ENGINEERING, SURVEY & LANDSCAPE
SUB FLOOR COORDINATE FININSH
WALL SHEATHING ARCHITECTURE, P.C.
3/4" CDX PLYWOOD WITH ARCHITECTURAL
mmmm 3 Garret Place, Carmel, New York 10512
2X6 BASE PLATE
DRAWING g. 2x6 LSL @ 16" o.c. EXTERIOR T: (845) 225-9690
STUD WALL
FIRST FLOOR FIRST FLOOR
-1' - 2 3/4" 1 1/2" CDX PLYWOOD REFER TO PLAN FIRST FLOOR
COORD. FINISH EXTERIOR GRADE WEB STIFFENERS ON TJI
WALL SHEATHING REFER TO PLAN
W/ ARCH. PLYWOOD SHEATHING
LSL RIMBOARD

LSL RIM BOARD 3/4" CDX PLYWOOD
NO RIM BOARD HERE ' ✗ 2X6 BASE PLATE
LSL RIMBOARD RAIN SCREEN PUSH HEADER -10 OUTSIDE LVL HEADER (FLUSH)
FIRST FLOOR
SEE PLAN
WOOD CLADDING
REFER TO PLAN

If
GRADE (EL. """ LSL RIM BOARD
VARIES) 2" EPS
GRADE (EL. VARIES)
q6
(2) 2x8 P.T. PLATE

I
2 - 2X6 CONTINUOUS
TOP PLATE
14" TJI JOIST.SEE PLAN ALL DESIGNS & SPECS ARE SUBJECT TO
CEMENT BOARD VERIFICATION OF EXG. FIELD CONDITIONS
+ PARGE COAT TJI JOIST (REFER PLAN)
JOIST HANGER CONNECTION
CONCRETE WALL REFER SCHEDULE 2 - 2X6 CONTINUOUS
CONCRETE WALL (REFER PLAN) TOP PLATE REVISIONS
(REFER PLAN)

t¥¥

[
"
234 -17¥
"
-
CURRENTLY DRAWN AS . . _
WHY ?
SHELF STEM

5 TYPICAL WALL SECTION @ SOLID/STUD WALL 6 TYPICAL WALL SECTION @ GLAZING 7 SECTION @ 2 STORY 7A SECTION @ 2 STORY
S-203 3/4" = 1'-0"
S-203 3/4" = 1'-0"
S-203 3/4" = 1'-0"
S-203 3/4" = 1'-0"

,, ,µgg,,,,,µ g ,µ ,
,µ , , µ, ,gµ ,,, g
,µgµ , , , NOT FOR CONSTRUCTION
REF .

2/4--601
SEE

NO OVERHANG #4 DOWELS (24"x24")


↑ ""

|
#4
4"/5" CONCRETE SLAB
COORDINATE FININSH
CONCRETE WALL
ñiiiiiiiiiinit
EXTERIOR PAVING
" ON GRADE (REFER
TYPICAL DETAILS) WITH ARCHITECTURAL
MMMM 2x6 LSL @ 16" o.c. EXTERIOR
STUD WALL
(REFER PLAN) SEE PLAN FOR REINFORCEMENT. COORDINATE WITH COORDINATE SLOPE WITH DRAWINGg-
ARCH. DRAWINGS SIGN & SEAL

CONCRETE WALL GRAY LINE BASEMENT/GARAGE "


2 "ÑÑnmmm
EXTERIOR GRADE
WEB STIFFENERS ON TJI

}.
1 1/2" CLEAR ✗ PLYWOOD SHEATHING 2 LAYERS 3/4" PLYWOOD ISSUES
\r
(REFER PLAN) µ , ,,µ, , ,
, SEE PLAN FOR SLOPE
COORDINATE DRAINAGE SUB FLOOR
2X6 BASE PLATE 01 2021.10.21 CORE AND SHELL PRICING SET
TENSION

COORDINATE EXTERIOR REQUIREMENTS WITH


SPLICE

INSULATION, RAT SLAB REFER TYPICAL 02 2022.04.25 UPDATED FLOOR PLANS


ARCHITECTURAL
MMMMM DRAWINGS
DETAILS. ON S-201 FIRST FLOOR
WATERPROOFING, AND SLAB ON GRADE. CONTRACTOR -10 PROVIDE 03 2022.05.02 INT. BUDGET ASSUMPTIONS
DRAINAGE REQUIREMENTS REFER TYPICAL DETAILS. CURVED SLAB EDGE REFER TO PLAN 04 2022.05.27 PROGRESS SET
SHEAR KEY AND CRAWLSPACE LSL RIM BOARD
WITH ARCHITECTURAL ON S-201 05 2022.06.10 PROGRESS SET
WATERSTOP
DRAWINGS REFER TO PLAN OVERHANG VARIES
wwnnrmnnrnnm 06 2022.06.17 PROGRESS SET
GR0Y☐Y¥
-
← CONCRETE WALL
4'-0" (MIN)

BASEMENT 2 - 2X6 CONTINUOUS


1
"
HOW 6 GRAVEL ( REFER PLAN )
SHEAR KEY AND REFER TO PLAN COORDINATE DRAINAGE TOP PLATE
WATERSTOP REQUIREMENTS WITH
GROUT , SLOPED ARCH. DRAWINGS
TO
-.F
DRAIN 3" COVER 14" TJI JOIST.SEE PLAN

DRAWING INFO
GROUT , SLOPED
FOOTING TO BEAR ON VIRGIN SOIL ON SITE _.::
SUITABLE FOR BEARING WITH AN ALLOWABLE TO DRAIN
BLOCKING @ 16" o.c.
BEARING PRESSURE OF 2 TSF (MINIMUM) GLUED AND SCREWED CONSTRUCTION DOCUMENTS
SEE PLAN FOR FOOTING OR ON CONTROLLED COMPACTED FILL. TO FLOOR DECK DRAWN BY: Author
3" COVER SIZE AND REINFORCEMENT
(2 ROWS) CHECKED BY: Checker
FOOTING TO BEAR ON VIRGIN SOIL ON SITE DATE: 05/26/22
SEE PLAN FOR FOOTING

COVER
SIZE AND REINFORCEMENT SUITABLE FOR BEARING WITH AN ALLOWABLE SCALE: As indicated
SEE PLAN FOR FOOTING

3"
BEARING PRESSURE OF 2 TSF (MINIMUM)
SIZE AND REINFORCEMENT PROJ. NO. Project Number
OR ON CONTROLLED COMPACTED FILL.

SECTIONS TYP. WOOD DETAILS


MMMM
1 SECTION @ BASEMENT 2 SECTION @ CRAWLSPACE 3 SECTION @ FROST WALL 4 SECTION @ 2 STORY
S-203 3/4" = 1'-0"

NOTE :( COPY # 1 FROM 5-100)


S-203 3/4" = 1'-0"

NOTE :( COPY # 1 FROM 5-100)


S-203 3/4" = 1'-0"
NOTE :( COPY # 1 FROM 5-100)
S-203 3/4" = 1'-0"
S-203
REF .
I / A- 601
REF
.
I / A- 603
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
141-1-604
RR2
RESIDENCE
1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514

OWNER
2X6 STUD WALL
RR ORCHARD HOLDINGS LLC
1347 HOLLOW RD, CLINTON CORNERS, NY 12514
fix
1/2" PLYWOOD
WALL SHEATHING 34" PLYWOOD
SUBFLOOR ARCHITECT

ÉÉ¥÷*¥
"
"

i i.÷
: ÷I¥¥¥¥¥÷ "
RAFTER SLOPED
TJ / JOIST
LVL HEADER

Jl
SHEATHING BE SIMPSON RAFTER
(REFER PLAN)
""
" """"
(REFER PLAN ) WORKSHOP/APD ARCHITECTURE DPC

FLAT 39 W 38th Street, 7th Fl, New York, NY 10018
LOOSE LINTEL " ""' "" ←
-
T: (212) 273-9712 info@workshopapd.com
(REFER ""

:
SCHEDULE) TJI RAFTER

C- GRAY , ,

CONTRACTOR
STIFFENER
WEB STONELEAF CONSTRUCTION
WALL STIFFENER 4974 Route 22 Amenia, NY 12501
T: (845) 373-8020

← No
LVL CANTILEVER BEAM

3 SECTION ( REFER PLAN)


S-204 3/4" = 1'-0" STRUCTURAL ENGINEER
④ MURRAY ENGINEERING


330 7th Avenue New York, NY 10001
REF .

3/1-1-571 T: (212) 741-1102

LANDSCAPE ARCHITECT
JAMES DOYLE DESIGN ASSOCIATES
125 Greenwich Avenue Greenwich, CT 06830
T: (203) 869-2900

SURVEYOR/ CIVIL ENG.


INSITE ENGINEERING, SURVEY & LANDSCAPE
1/2" CDX PLYWOOD ARCHITECTURE, P.C.
WALL SHEATHING 3 Garret Place, Carmel, New York 10512
2X6 STUD WALL T: (845) 225-9690
INATE
COORD.iFINISH 2 LAYERS 1/2" CDX PLYWOOD
W/ ARCH. DRAWINGS 3/4" PLYWOOD SUB FLOOR 1/2" CDX PLYWOOD SHEATHING
ITH SHEATHING
LSL BLOCKING TJI JOIST (REFER PLAN) COORDINATE
COORDINATE ROOF ASSEMBLY
ROOF ASSEMBLY WITH ARCHITECT
FIRST FLOOR
\ WITH ARCHITECT
-1' - 2 3/4"
LSL RIMBOARD
TJI RAFTER
TJI RAFTER (REFER PLAN)
1/2" CDX PLYWOOD
(REFER PLAN)
SHEATHING

ALL DESIGNS & SPECS ARE SUBJECT TO


VERIFICATION OF EXG. FIELD CONDITIONS
CONT. DOUBLE
CONT. DOUBLE TOP PLATE
GRADE (EL. VARIES)
TOP PLATE 2X6 STUD WALL REVISIONS
CONCRETE WALL LVL HEADER 1/2" CDX PLYWOOD TJI RAFTER.
(REFER PLAN) (REFER PLAN) WALL SHEATHING REFER PLAN

1/2" CDX PLYWOOD COORDINATE BLOCKING @ 16" O.C.


WALL SHEATHING WALL ASSEMBLY GLUED AND SCREWED TO
WITH ARCHITECT
.MN FLOOR DECK (2 BAYS)
DRAWINGS

2 SECTION 5 SECTION 7 SECTION 9 SECTION NOT FOR CONSTRUCTION


S-204 3/4" = 1'-0"
S-204 3/4" = 1'-0"
S-204 3/4" = 1'-0"
S-204 3/4" = 1'-0"

REF
.
I
/ A- 602 REF .
3/1-1-604

COORDINATE ROOF COORDINATE ROOF


ASSEMBLY WITH ASSEMBLY WITH
ARCHITECT ARCHITECT
1/2" CDX PLYWOOD 1/2" CDX PLYWOOD
SEE PLAN FOR REINFORCEMENT. WALL SHEATHING WALL SHEATHING SIGN & SEAL

2X6 STUD WALL 3/4" PLYWOOD 2X6 STUD WALL 3/4" PLYWOOD
CONCRETE WALL
(REFER PLAN) TJI RAFTER
SUBFLOOR
TJI RAFTER
SUBFLOOR ISSUES
COORDINATE DRAINAGE 01 2021.10.21 CORE AND SHELL PRICING SET
(REFER PLAN) TJI JOIST. (REFER PLAN) TJI JOIST.
TENSION

REQUIREMENTS WITH
SPLICE

RAT SLAB REFER TYPICAL REFER PLAN REFER PLAN 02 2022.04.25 UPDATED FLOOR PLANS
ARCHITECTURAL DRAWINGS DETAILS. ON S-201 03 2022.05.02 INT. BUDGET ASSUMPTIONS
LOW ROOF SECOND FLOOR SECOND FLOOR 04 2022.05.27 PROGRESS SET
SHEAR KEY AND CRAWLSPACE 3/4" PLYWOOD SUBFLOOR
REFER TO PLAN REFER TO PLAN REFER TO PLAN 05 2022.06.10 PROGRESS SET
WATERSTOP
REFER TO PLAN 06 2022.06.17 PROGRESS SET
SECOND FLOOR
REFER TO PLAN

3" COVER
SKEWED JOIST
HANGER LVL LEDGER PROVIDE 2
ROWS SDSW22400DB
[ LINE WEIGHT LOOKS -100 BOLD

FOOTING TO BEAR ON VIRGIN SOIL ON SITE LVL LEDGER LSL BLOCKING @ 16" O.C. DRAWING INFO
SUITABLE FOR BEARING WITH AN ALLOWABLE
BEARING PRESSURE OF 2 TSF (MINIMUM) CONSTRUCTION DOCUMENTS
TIGHT TO LVL HEADER
SEE PLAN FOR FOOTING
-

OR ON CONTROLLED COMPACTED FILL. TJI RAFTER. REFER PLAN DRAWN BY: Author
UNDERSIDE REFER PLAN
SIZE AND REINFORCEMENT OF TOP DOOR OPENING CHECKED BY: Checker
PLATE
BLOCKING @ 16" O.C. DATE: 07/13/22
GLUED AND SCREWED TO SCALE: 3/4" = 1'-0"
FLOOR DECK (2 BAYS) PROJ. NO. Project Number

TYP. WOOD DETAILS


1 SECTION 4 SECTION 6 SECTION 8 SECTION
S-204 3/4" = 1'-0"
S-204 3/4" = 1'-0"
S-204 3/4" = 1'-0"
S-204
REF
.
3/4" = 1'-0"

2/1-1-604
S-204
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
CANTILEVER LENGTH
VARIES AS RIDGE LINE CURVES
RR2
RESIDENCE
1 4
S-205 S-205 1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514

FULL HEIGHT
2X6 LSL STUD
OWNER
RR ORCHARD HOLDINGS LLC
2x6 LSL TOP 1347 HOLLOW RD, CLINTON CORNERS, NY 12514
PLATE
2X6

ARCHITECT
¥
2
S-205 .

WORKSHOP/APD ARCHITECTURE DPC


39 W 38th Street, 7th Fl, New York, NY 10018
4" BRICK COORD. T: (212) 273-9712 info@workshopapd.com
TYPE AND PATTERN

|
WITH ARCH. (2) 1-3/4" X 14" LVL, CUT TO STEP, MOVE UP
,
SEE ELEVATION PROVIDE (2) SHOW AS 12
"

BRICK ANCHOR @ SDWS22800DB INTO EACH STUD CONTRACTOR

/
16" O.C. ± VERTICAL
AND HORIZONTAL STONELEAF CONSTRUCTION
EXTEND -
4974 Route 22 Amenia, NY 12501
PLYWOOD T: (845) 373-8020


3 SECTION 01 NO TAIL

STRUCTURAL ENGINEER
S-205 3/4" = 1'-0"
MURRAY ENGINEERING
MORTAR MESH. COORD. 330 7th Avenue New York, NY 10001
WITH ARCH.
.

/
REF 2 A -605
T: (212) 741-1102

EP

.
CH
ST

AR
O
TT

ITH
WATERPROOFING
LANDSCAPE ARCHITECT

CU

W
COORD. W/ ARCH. CANTILEVER LENGTH VARIES BEARING WALL

N
BLOCKING @

VL

ER
AS RIDGE LINE CURVES ON LVL BEAM BELOW

"L
2 END BAYS

TT
18
JAMES DOYLE DESIGN ASSOCIATES

PA
X
125 Greenwich Avenue Greenwich, CT 06830

K
"
1-3/4/" X 9-1/2" LVL LEDGER

3/4

IC
T: (203) 869-2900

BR
) 1-
(2

.
RD
SCREW @ 12" o.c. TJI RAFTER

O
CO
STAGGERED
2X8 TJI RAFTER SURVEYOR/ CIVIL ENG.
INSITE ENGINEERING, SURVEY & LANDSCAPE
2X8 LSL STUD TO
ARCHITECTURE, P.C.
UNDERSIDE OF LEDGER 3 Garret Place, Carmel, New York 10512
T: (845) 225-9690

1 BRICK PARAPET COPING 2 ROOF SECTION SHOWING BRICK PARAPET COPING


S-205 1 1/2" = 1'-0"
S-205 1 1/2" = 1'-0"

CURVED RIDGE
BOARD

BLOCKING

ALL DESIGNS & SPECS ARE SUBJECT TO


VERIFICATION OF EXG. FIELD CONDITIONS

4 SECTION 02 5 SECTION REVISIONS


S-205 3" = 1'-0"
S-205 3/4" = 1'-0"

BLOCKING BETWEEN JOISTS AT POSTS

CURVED BUILT-OUT EDGE


NOT FOR CONSTRUCTION
1/2" PLYWOOD SHEATHING
5" WITH APPLIED WRB 1ST LAYER 2x4 NAILERS
(BENT IN WEAK AXIS)

2X4" AND 1/2" PLYWOOD 2


FACETED RIMJOIST 2ND LAYER 2x4 NAILERS
7 1/4"

BUILD-UP W/ 3/4" WOOD (BENT IN WEAK AXIS)


CLADDING
RADIAL RAFTERS @ 16" o.c. 3

FACE OF (2)-2x6 POSTS UP AT MULLIONS


CONCRETE BELOW
SPAN DIRECTION
2ND LAYER 2x4 NAILER INFILL
OF SUBFLOOR
1/2" GYPSUM (BENT IN WEAK AXIS)
SIGN & SEAL
4
CONC. FOUNDATION WALL
3/4" THIN BRICK BELOW (REFER PLAN) ISSUES
01 2021.10.21 CORE AND SHELL PRICING SET
1/2" THINSET MORTAR 02 2022.04.25 UPDATED FLOOR PLANS
03 2022.05.02 INT. BUDGET ASSUMPTIONS
1/2" CEMENT BOARD 04 2022.05.27 PROGRESS SET
PLYWOOD SHEATHING 05 2022.06.10 PROGRESS SET
5/8" PLYWOOD
NOTE: THE NAILERS ALLOW THE 4'x8' SHEETS 06 2022.06.17 PROGRESS SET
1' - 4"

OF PLYWOOD TO REMAIN RECTANGULAR,


PARALLEL, AND FASTENED ON ALL 4 SIDES
TJI FLOOR JOIST DIRECTLY TO THE NAILERS.
ONLY EDGES NEED TO BE CUT ON A CURVE.
IN LIEU OF EACH SHEET NEEDING TO BE CUT
2X8+2X6 LSL @ TO FALL ON RADIAL RAFTER
16" O.C. MAX. DRAWING INFO
CANTILEVER 5
CONSTRUCTION DOCUMENTS
LENGTH VARIES DRAWN BY: Author
CHECKED BY: Checker
DATE: 06/10/22
SCALE: As indicated
PROJ. NO. Project Number

6 STUD WALL PLAN DETAIL 7 TYPICAL PLAN DETAIL 8 TYPICAL CURVED ROOF ASSEMBLY TYP. WOOD DETAILS

S-205
S-205 1 1/2" = 1'-0"
S-205 3/4" = 1'-0"
S-205 3/4" = 1'-0"

COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC


2
3
4
RR2
RESIDENCE
5
1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514

6 OWNER
RR ORCHARD HOLDINGS LLC
1 DN
S-301
1347 HOLLOW RD, CLINTON CORNERS, NY 12514
S-300 6 1
S/CS/C S-301
4 5 ARCHITECT
S-300 S/C
S-300 S-301 S-301
5 2 S-301
3 4 DN WORKSHOP/APD ARCHITECTURE DPC
6 39 W 38th Street, 7th Fl, New York, NY 10018
S-300 DN
3 T: (212) 273-9712 info@workshopapd.com
1

DN
S-301 DN
2
S-302
S-300 DN
CONTRACTOR
STONELEAF CONSTRUCTION
4974 Route 22 Amenia, NY 12501
T: (845) 373-8020
S-302
DN
2 ROOF LINE ROOF LINE
BEYOND STRUCTURAL ENGINEER

DN
HEADER. MOVE DOWN !
3 LOOSE LINTEL.
SEE PLAN
7
HEADERS ABOVE
SEE SCHEDULE WINDOW / DOOR
MURRAY ENGINEERING
330 7th Avenue New York, NY 10001
S-302 OPENING
T: (212) 741-1102
G KING STUD

F Ñ-
TYP
JACK STUDS LANDSCAPE ARCHITECT
.

FRAMING
E NOT SHOWN
FOR CLARITY JAMES DOYLE DESIGN ASSOCIATES
D I 125 Greenwich Avenue Greenwich, CT 06830
T: (203) 869-2900

C S-302 S/C
S/C
8 SURVEYOR/ CIVIL ENG.
B
7

T.O.F.F. ELEV.
A 6
S-302
4
S-302
T.O.SHELF ELEV.
-1'-2 3/4" INSITE ENGINEERING, SURVEY & LANDSCAPE
ARCHITECTURE, P.C.
5 T.O.STEM ELEV.
S-302 -3'-9" -2'-9" 3 Garret Place, Carmel, New York 10512
T.O.SHELF ELEV.
T: (845) 225-9690
-3'-9"
HD 9 3" CONCRETE
RAT SLAB
T.O.SLAB ELEV.
-6'-10"

11 10

1 RADIAL WALL KEY PLAN 2 ELEVATION WALL 1-1 3 ELEVATION WALL 1'-1' ALL DESIGNS & SPECS ARE SUBJECT TO
VERIFICATION OF EXG. FIELD CONDITIONS

S-300 1/16" = 1'-0"


S-300 3/16" = 1'-0"
S-300 3/16" = 1'-0"

REVISIONS
LEGEND:

#-# = ELEVATIONS CUT CLOCKWISE

#'-#' = ELEVATIONS CUT COUNTERCLOCKWISE

ROOF LINE
ROOF LINE
NOT FOR CONSTRUCTION
ROOF LINE
ROOF LINE BEYOND ROOF LINE BEYOND

ROOF LINE BEYOND HEADER. HEADER.


SEE PLAN SEE PLAN

LOOSE LINTEL.
SEE SCHEUDLE HEADER.
SEE PLAN

KING STUD
KING STUD KING STUD

± ✓

SIGN & SEAL

JACK STUDS
" JACK STUDS
JACK STUDS ISSUES
Eos ① ⑨
MOVE
01 2021.10.21 CORE AND SHELL PRICING SET
IN
02 2022.04.25 UPDATED FLOOR PLANS
03 2022.05.02 INT. BUDGET ASSUMPTIONS
T.O.F.F. ELEV. 04 2022.05.27 PROGRESS SET
-1'-2 3/4" 05 2022.06.10 PROGRESS SET
T.O.F.F. ELEV.
T.O.STEM ELEV. 06 2022.06.17 PROGRESS SET
T.O.F.F. ELEV. -1'-2 3/4"
T.O.STEM ELEV. -2'-9" T.O.SHELF ELEV.
-1'-2 3/4"
T.O.STEM ELEV. T.O.SHELF ELEV. -2'-9" -3'-9"
T.O.SHELF ELEV. -2'-9" -3'-9"
-3'-9"

T.O.SLAB ELEV.
-6'-10"
DRAWING INFO
CONSTRUCTION DOCUMENTS
4" SLAB ON GRADE DRAWN BY: Author
T.O.SLAB ELEV. CHECKED BY: Checker
T.O.SLAB ELEV. -12'-3" DATE: 06/10/22
-12'-3" SCALE: As indicated
PROJ. NO. Project Number

WALL ELEVATIONS

4 ELEVATION WALL 2-2 5 ELEVATION WALL 2'-2' 6 ELEVATION WALL 3-3 S-300
S-300 3/16" = 1'-0"
S-300 3/16" = 1'-0"
S-300 3/16" = 1'-0"
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
RR2
RESIDENCE
ROOF LINE
BEYOND
1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514

ROOF LINE OWNER


ROOF LINE
RR ORCHARD HOLDINGS LLC
1347 HOLLOW RD, CLINTON CORNERS, NY 12514
HEADER. ROOF LINE
SEE PLAN "" "" € " BEYOND

]
CANTILEVER HEADER 2-134×14 LVL
HEADER. ARCHITECT
FLAT ROOF MMK LOOSE LINTEL. HEADER.

µ
SEE PLAN

]
RAFTERS ✗ LINE
FLAT ROOF SEE SCHEDULE SEE PLAN
"
" " "" NO BOLD LINE
WORKSHOP/APD ARCHITECTURE DPC
✗ ✗ 39 W 38th Street, 7th Fl, New York, NY 10018
KING STUD "
KING STUD ˢ " T: (212) 273-9712 info@workshopapd.com
°
" " " """"
" " "'
(2)
SEE PLAN
2 KING
JACK STUDS
JACK STUDS KING STUD S
2 CONTRACTOR
JACK STUD s STONELEAF CONSTRUCTION
3
4974 Route 22 Amenia, NY 12501
T: (845) 373-8020

T.O.F.F. ELEV.
-1'-2 3/4" T.O.F.F. ELEV.
T.O.STEM ELEV.
T.O.SHELF ELEV. -2'-9" T.O.STEM ELEV.
-1'-2 3/4"
T.O.STEM ELEV.
STRUCTURAL ENGINEER
-3'-9" -2'-9" T.O.SHELF ELEV. -2'-9" T.O.SHELF ELEV.
MURRAY ENGINEERING
-3'-9" -3'-9" 330 7th Avenue New York, NY 10001
T: (212) 741-1102

LANDSCAPE ARCHITECT
T.O.SLAB ELEV. JAMES DOYLE DESIGN ASSOCIATES
-12'-3" T.O.SLAB ELEV. T.O.SLAB ELEV. 125 Greenwich Avenue Greenwich, CT 06830
-12'-3" -12'-3" T: (203) 869-2900

SURVEYOR/ CIVIL ENG.


INSITE ENGINEERING, SURVEY & LANDSCAPE
ARCHITECTURE, P.C.
3 Garret Place, Carmel, New York 10512
T: (845) 225-9690
1 ELEVATION WALL 3'-3' 2 ELEVATION WALL 4-4 3 ELEVATION WALL 4'-4'
S-301 3/16" = 1'-0"
S-301 3/16" = 1'-0"
S-301 3/16" = 1'-0"

ROOF LINE ALL DESIGNS & SPECS ARE SUBJECT TO


BEYOND VERIFICATION OF EXG. FIELD CONDITIONS
LOOSE LINTEL.
SEE SCHEDULE

REVISIONS
HEADER. SEE PLAN
ROOF LINE FLAT ROOF LINE
BEYOND
ROOF LINE
HEADER.
SEE PLAN
LOOSE LINTEL.
KING STUD SEE SCHEDULE

KING STUD NOT FOR CONSTRUCTION


JACK STUDS
JACK STUD

T.O.F.F. ELEV. T.O.F.F. ELEV.


-1'-2 3/4" -1'-2 3/4"

T.O.STEM ELEV.
T.O.SHELF ELEV. -2'-9"
-3'-9"

SIGN & SEAL

ISSUES
T.O.SLAB ELEV. T.O.SLAB ELEV. 01 2021.10.21 CORE AND SHELL PRICING SET
-12'-3" -12'-3"
02 2022.04.25 UPDATED FLOOR PLANS
T.O.SLAB ELEV. 03 2022.05.02 INT. BUDGET ASSUMPTIONS
-12'-3" 04 2022.05.27 PROGRESS SET
05 2022.06.10 PROGRESS SET
06 2022.06.17 PROGRESS SET

DRAWING INFO
4 ELEVATION WALL 5-5 5 ELEVATION WALL 5'-5' 6 ELEVATION WALL 6-6 CONSTRUCTION DOCUMENTS
S-301 3/16" = 1'-0"
S-301 3/16" = 1'-0"
S-301 3/16" = 1'-0" DRAWN BY:
CHECKED BY:
Author
Checker
DATE: 06/10/22
SCALE: 3/16" = 1'-0"
PROJ. NO. Project Number

WALL ELEVATIONS

S-301
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
ROOF LINE
ROOF LINE
ROOF LINE
BEYOND
RR2
RESIDENCE
HEADER.
HEADER. SEE PLAN
FLAT ROOF LINE SEE PLAN 1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
BEYOND FLAT ROOF LINE
HEADER. BEYOND
FLAT ROOF LINE
LOOSE LINTEL.
SEE SCHEDULE
SEE PLAN
OWNER
LOOSE LINTEL.
LOOSE LINTEL. SEE SCHEDULE RR ORCHARD HOLDINGS LLC
SEE SCHEDULE
1347 HOLLOW RD, CLINTON CORNERS, NY 12514

KING STUD
KING STUD
KING STUD ARCHITECT
JACK STUD
JACK STUD JACK STUD
WORKSHOP/APD ARCHITECTURE DPC
39 W 38th Street, 7th Fl, New York, NY 10018
T: (212) 273-9712 info@workshopapd.com

T.O.F.F. ELEV. T.O.F.F. ELEV. CONTRACTOR


-0'-7 3/4" -0'-0 3/4"
T.O.F.F. ELEV.
-0'-7 3/4" T.O.STEM ELEV. STONELEAF CONSTRUCTION
T.O.STEM ELEV.
T.O.STEM ELEV. 4974 Route 22 Amenia, NY 12501
T.O.SHELF ELEV. -2'-9" -2'-2" T.O.SHELF ELEV.
-2'-2" T: (845) 373-8020
-3'-9" T.O.SHELF ELEV. -3'-2"
-3'-2"

T.O.SLAB ELEV.
-6'-10"
STRUCTURAL ENGINEER
MURRAY ENGINEERING
330 7th Avenue New York, NY 10001
T: (212) 741-1102
T.O.SLAB ELEV.
-12'-3" T.O.SLAB ELEV.
-12'-3"
LANDSCAPE ARCHITECT
JAMES DOYLE DESIGN ASSOCIATES
125 Greenwich Avenue Greenwich, CT 06830

1 ELEVATION WALL 6'-6' 2 ELEVATION WALL 7-7 3 ELEVATION WALL 7'-7' T: (203) 869-2900

S-302 3/16" = 1'-0"


S-302 3/16" = 1'-0"
S-302 3/16" = 1'-0"
SURVEYOR/ CIVIL ENG.
INSITE ENGINEERING, SURVEY & LANDSCAPE
ARCHITECTURE, P.C.
3 Garret Place, Carmel, New York 10512
T: (845) 225-9690
ROOF LINE
ROOF LINE BEYOND
ROOF LINE
FLAT ROOF LINE
BEYOND
FLAT ROOF LINE
HEADER.
SEE PLAN HEADER.
HEADER. SEE PLAN
SEE PLAN
/
"
KING STUD KING STUDˢ
/ KING STUD

JACK STUD
"

JACK STUD5
"" """" "
"
NOT SHOWN

FOR CLARITY
"" "

JACK STUD
% ALL DESIGNS & SPECS ARE SUBJECT TO
VERIFICATION OF EXG. FIELD CONDITIONS

/
FLOOR FRAMING BEYOND
REVISIONS

T.O.F.F. ELEV.
[ [
GARAGE
SLAB ON GRADE

T.O.SHELF ELEV.

¥mÉm
-

-0'-0 3/4"
T.O.SLAB ELEV. T.O.SLAB ELEV. -0'-9"
-1'-4"
=
"
I -1'-4"
M
T.O.STEM ELEV. T.O.STEM ELEV.

T.O.SHELF ELEV. -2'-9" T.O.SHELF ELEV. -2'-9" T.O.SHELF ELEV.
-3'-9" -3'-9" ¥ * * ×
-3'-9"
* SOIL HATCH

T.O.SLAB ELEV. NOT FOR CONSTRUCTION


-6'-10"

6 ELEVATION WALL 11-11


4 ELEVATION WALL 10-10 5 ELEVATION WALL 10'-10' S-302 3/16" = 1'-0"
S-302 3/16" = 1'-0"
S-302 3/16" = 1'-0"

ROOF LINE
BEYOND
SIGN & SEAL

ISSUES
01 2021.10.21 CORE AND SHELL PRICING SET
02 2022.04.25 UPDATED FLOOR PLANS
03 2022.05.02 INT. BUDGET ASSUMPTIONS
04 2022.05.27 PROGRESS SET
LOOSE LINTEL.
05 2022.06.10 PROGRESS SET
SEE SCHEDULE
06 2022.06.17 PROGRESS SET

DRAWING INFO
CONSTRUCTION DOCUMENTS
DRAWN BY: Author
CHECKED BY: Checker
DATE: 06/10/22
SCALE: 3/16" = 1'-0"
M
T.O.SHELF ELEV. PROJ. NO. Project Number
-3'-9"

WALL ELEVATIONS

7 ELEVATION WALL 11'-11'


S-302
S-302 3/16" = 1'-0" COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC
RR2
RESIDENCE
1347 HOLLOW ROAD, CLINTON CORNERS, NY 12514
8 9
23' - 1 1/8" OWNER
(3) 1 3/4x14 LVL RR ORCHARD HOLDINGS LLC
RIDGE BEAM 1347 HOLLOW RD, CLINTON CORNERS, NY 12514
ROOF
+27' - 3 1/8"

ARCHITECT

WORKSHOP/APD ARCHITECTURE DPC


39 W 38th Street, 7th Fl, New York, NY 10018
HOT TUB BY T: (212) 273-9712 info@workshopapd.com
OTHERS

CONTRACTOR
STONELEAF CONSTRUCTION
4974 Route 22 Amenia, NY 12501
T: (845) 373-8020

SECOND FLOOR
+10' - 10 1/4"
10" CONC.
STRUCTURAL ENGINEER
HSS5X5X1/2

HSS5X5X1/2

GRADE BEAM
MURRAY ENGINEERING
330 7th Avenue New York, NY 10001
T: (212) 741-1102

LANDSCAPE ARCHITECT
BACKFILL
12" CONC. WALL 12" CONC. WALL JAMES DOYLE DESIGN ASSOCIATES
FIRST FLOOR 125 Greenwich Avenue Greenwich, CT 06830
-0' - 0 3/4" T: (203) 869-2900

SURVEYOR/ CIVIL ENG.


INSITE ENGINEERING, SURVEY & LANDSCAPE
CRAWL SPACE ARCHITECTURE, P.C.
-6' - 10" 36" WIDE x 10" THICK 3 Garret Place, Carmel, New York 10512
CONC. FTG. T: (845) 225-9690

1 ELEVATION 3 SECTION
S-303 3/16" = 1'-0"
S-303 1/2" = 1'-0"

ALL DESIGNS & SPECS ARE SUBJECT TO


VERIFICATION OF EXG. FIELD CONDITIONS

9 8 REVISIONS
23' - 1 1/8"

(3) 1 3/4x14 LVL


RIDGE BEAM
ROOF
+27' - 3 1/8" HOT TUB BY
OTHERS

NOT FOR CONSTRUCTION


12" FINISH

12" CONC. WALL 12" CONC. WALL

10" CONC.
GRADE BEAM

(2)
(2)113/4x14
3/4x14LVL
LVL SECOND FLOOR
HSS5X5X1/2

HSS5X5X1/2

+10' - 10 1/4"

SIGN & SEAL

ISSUES
01 2021.10.21 CORE AND SHELL PRICING SET
02 2022.04.25 UPDATED FLOOR PLANS
03 2022.05.02 INT. BUDGET ASSUMPTIONS
04 2022.05.27 PROGRESS SET
BACKFILL 05 2022.06.10 PROGRESS SET
FIRST FLOOR 06 2022.06.17 PROGRESS SET
-0' - 0 3/4"

CRAWL SPACE
DRAWING INFO
36" WIDE x 10" THICK
-6' - 10" CONSTRUCTION DOCUMENTS
CONC. FTG.
DRAWN BY: Author
CHECKED BY: Checker
DATE: 06/23/22
SCALE: As indicated

ELEVATION SECTION
PROJ. NO. Project Number
2 4
S-303 3/16" = 1'-0"
S-303 1/2" = 1'-0"
SECTIONS & ELEVATIONS

S-303
COPYRIGHT © 2020 WORKSHOP/APD ARCHITECTURE DPC

You might also like