EP series

WPS625
50 Hz @ 1500rpm,3-phase/4-wiring

1 Standards & Conditions • Lockable battery isolator switch


• 50℃ radiator
Design Standards • Oil pump on the engine

The designs and the productions are in conformity with:


• Steel base frame with lifting lugs

• Conformite Europeenne (CE)


• Vibration isolators between the engine/alternator and
base frame
• China Compulsory Certification (CCC)
• Dry type air filter
• ISO8528-5:2005
• Base fuel tank for 9 hours running
• GB/T2820.5-2009
• Drain points for fuel tank
• Operation Manual / Specifications
Environmental Operating Conditions
• Installation place: Indoors (well ventilated).
3 Equipment Specification
• Ambient temperature: -25℃ to 50℃.The coolant heater
is needed when the temperature is below 5℃
• Humidity: Less than 80%. General technical data
• Altitude: Below one thousand (1000) meters above sea
level.

Factory Inspection
• Inspection items.
• Protection devices working test.
• Starting ability in normal temperature.
• 50% rated power load moment capability.
• Voltage deviation and speed variation: 0%, 25%, 50%,
75%, 100%, 110% Load.

Painting Process
• Painting process specifications and colors are based on Model......................................................................WPS625
the manufacturer's standard.
• The customer could also choose the color which the Structure type .................................................................... B
manufacturer offers. Tank capacity..............................................................1200L
Dry weight................................................................. 4687kg
2 General Features Sound pressure level @7m ............................................N/A
Sound power level acc. 2000/14/EC .............................N/A
• Perkins engine 2806A-E18TAG2
Dimensions L×W×H............................ 3800x1536x2279mm
• Close coupled to a Leroy Somer alternator LSA49.1S4A
Standby Power ......................................... 687.5kVA/550kW
• Microprocessor control module PLC-7420
Prime Power ................................................ 625kVA/500kW
• DMA main circuit breaker: 1000A
• Rotate speed governor: Electronic fuel injection gover- Voltage 380V 400V 415V 440V
nor
• Excitation system: AREP Ampere 949.6A 902.1A 869.5A 820.1A
• A.V.R model: R448 Genset Fuel Consumption
• Key switch
Frequency/Load 25% 50% 75% 100% 110%
• ATS (automatic transfer switch) receptacle
50Hz (L/h) N/A 66 97 132 143
• 2x12V/150AH sealed for life maintenance free battery
Diesel Engine Alternator Manufacturer/Brand ........................ Leroy Somer
Alternator Model .............................................. LSA49.1S4A
Exciter................................................................... Brushless
Cooling Fan ......................................... Cast alloy aluminum
Windings..........................................................100% copper
Insulation Class ................................................................. H
Winding Pitch ..................................................................2/3
Terminals ............................................................................6
Drip Proof ..................................................................... IP23
Altitude.....................................................................≤1000m
Overspeed ..............................................................2250rpm
Air Flow..................................... 1m³/s(50Hz),1.2m³/s(60Hz)
Engine Manufacturer/Brand......................................Perkins Voltage Regulation .....................................................±0.5%
Engine Model.............................................2806A-E18TAG2 Total harmonic TGH / THC at no load < 4 % - on load < 4%
Dimensions L×W×H.........................2545×1536×1807.5mm Telephone Interference.............................. THF<2%;TIF<50
Dry Weigh (approx.) ................................................. 2050kg
Number of Cylinders...........................................................6 PLC-7420 Control System
Bore ..........................................................................145mm
Stroke .......................................................................183mm
Displacement.............................................................18.13L
Compression Ratio ........................................................14.5
Type of Injection ..........................................................MEUI
Intake System.......... Turbocharged,air-to-air charge cooled
Intake Resistance ................................................... 6.4kPa
Cooling System ...............................................Water cooled
Fan ........................................................................... Pusher
Battery Voltage .............................................................. 24V
Type of Fuel........................ BS2869 class A2 or BS EN590
Type of Oil ......................................... API CG4 or APEA E5 PLC-7420 is an advanced control module based on micro-
Oil Capacity ....................................................................62L processor, containing all necessary functions for protection
of the genset and the breaker control. It can monitor the
Type of Coolant ............................................. Glycol Mixture
mains supply, and automatically start the engine when the
Coolant capacity .............................................................61L
mains is abnormal. Accurately measure various operational
Back Pressure ........................................................ 6.9kPa parameters and display all values and alarms information on
Standby Power ..........................................................628kW the LCD. In addition, the control module can automatically
Prime Power ..............................................................584kW shut down the engine and indicate the engine failure.
Fuel Consumption(100%load) ...................................132L/h • Microprocessor control, with high stability and credibility
• Monitoring and measuring operational parameters of the
Alternator mains supply and genset
• Indicating operation status, fault conditions, all parame-
ters and alarms
• Multiple protections; multiple parameters display, like
pressure, temp. etc.
• Manual, automatic and remote work mode selectable
• Real time clock for time and date display, overall runtime
display, 250 log entries
• Overall power output display
• Integral speed/frequency detecting, telling status of
start, rated operation, overspeed etc.
• Communication with PC via RS485 OR RS232 interface,
using MODBUS protocol
4 Overall Dimensions
5 Control System
1000020441–H2–E

05.2015

You might also like