You are on page 1of 5

MC WIRELESS Test Plan This form is for new entries.

orm is for new entries. If you have already started your form, please click "Select a Different Model"

Import data from a previous Online project

Same Job Number

rmendez@p4 Select a Different Model New Model of this type


JOB #: 109237 Send Password to this email address:

METrak Job Title:SUNTRACK


Name of EUT Model: (original name/identifier) SUNTRACK TCU2020
» Main
Form Revised Model Name (to appear in final report) SUNTRACK TCU2020
Solar Tracker control Unit. It calculates the Sun position (East or West) and
EUT List control an external engine that moves a line of solar panels on a solar filed, so
the solar panels are all the time following the SUN. It should be a master control
Ports and unit that commands this unit through Zigbee radio communication, but if the
Cabling Description of EUT and its intended use:
communication is lost, the units are capable to estimate the Sun position and
work independently. If also have some auxiliary protection functions like safe
Support
positions (if the are strong winds), clean position, out of range, motor failures
Equipment
(no movement, too low or high current consumption), etc.
The EUT acts as a slave unit. This means that never will start the
Submit All communication. Only answer to master queries.
For Review Selected Operation Mode(s): To test it, it is needed a MASTER UNIT, and the easiest way to test is to be
(This section describes how the EUT is simulating normal operations.
continuously interrogating the unit. P4Q Will provide a master unit and a
NOTE: Please name and describe each mode of operation to be tested. There needs to be a control program that is all the time communicating with the EUT as fast as
means of continuously exercising the EUT without manual interaction. Please clarify
exactly how the EUT will be continuously operated during EMC testing.)
possible. Normally the channel is shared by more than 100 units and in this
setup there will be only one unit transmitting as fast as possible, so the test
conditions will be the worst possible.
Rationale for the selection of the Operation Mode(s): The MASTER UNIT has a webserver that allow to change all function
(This section describes how the manufacture determined the typical use operation conditions parameters. For this test only two parameters are important: The power, that can
of the EUT, with respect to the expected highest level of emissions. be set-up to maximum all time, and the Frequency Channel. There is a channel
The frequency of highest disturbance, with respect to the limit, was found by investigating
disturbances at a number of significant frequencies. This provides confidence that the mask that allow to set-up the allowed working channels. By changing it to only
probable frequency of maximum disturbance has been found and that the associated cable, one allowed channel the EUT can be configured to work on a particular
EUT arrangement and mode of operation has been identified.) frequency channel (low, mis, high…).
The EUT will be continuously interrogating by a Master Unit, with a
Monitoring Method(s): intended specific test program. If the communication is OK the
(What is the measurable, physical or electrical indication that the EUT is (#1) and is not (#2)
performing its intended function(s) consistent with the intended mode of operation defined
program will show the message “Read Ok”, if not “Communication
above?) Failure”. As this test will be done in a short distance, no
communication failures are spected.

Class A ITE where the device is intended primarily for use in an


environment where the use of broadcast radio and television receivers may be
expected within a distance of 10 m. A warning will be included in the user
manual.

Emissions Class Declaration: ---OR----

Class B ITE where the device is intended primarily for use in an


environment where the use of broadcast radio and television receivers may be
expected within a distance of 10 m .

To simulate a real working condition, it is needed a Zigbee Master coordinator


Configuration(s): (Digi Connect Port X2.), that will be connected to a standard PC running
(This section shall describe the physical configuration of the EUT. windows, with a standard Ethernet cable. It is needed a standard web browser,
Name and describe each configuration to be tested) and a P4Q test program- The EUT will need a 24V external power supply, an
antenna cable and the antenna. All the elements will be provided by P4Q.
EUT Power Requirement:
The EUT has a 24VDC input. Will be installed with different supply
configurations using external power supply systems. But, this will have its own
Voltage: certifications, and won’t affect the radio emissions as wont have any transmitter
or radio frequency source. The sample for testing will we provides with an
auxiliary 220V AC poser supply.
AC

AC or DC:

50
Voltage Frequency (Hz):
1
Number of phases:
Current (Amps): 0,1

Uses an external AC/DC adapter: Yes No


Physical Description
(If the EUT has multiple possible orientations, specify the orientation to be tested.)
EUT Arrangement Both
(Table Top, Floor Standing or Both)
System w/ Multiple Chassis Yes No
Size (HxWxD - inches): 12,48 X 11,01 X 5,90
Weight (lbs): 2,2
Other info:
Highest Internal Frequency: 2475 MHz
EUT Software
(internal to EUT) RAFA MIRARI
Support Software
(used by support PC to exercise EUT) Log.exe
Firmware Type: (if applicable)
Canadian Submissions, please provide the following:
PMN (Product Marketing Name) SUNTRAC TCU2020
HVIN (Hardware Version Identification Number) Iker
FVIN (Firmware Version Identification Number) RAFA MIRARI
HMN (Hosting Marketing Name -
specific only for Modular Approvals)
Transmitter Parameters:
FHSS
DSSS
Hybri
Which of these best describes your unit (check one)
d
Other
If Other please specify:
Modulation Type: Offset-QPSK
# of Channels:
Frequency range (MHz): 2405-2475 MHz
Antenna type: Dipole antena
Antenna gain (dBi): 2
Data Rates (List All) 250 kbps
Expected Power Level +18
1
Number of Antennas:
1
Number of Intentional Transmitters:
1
Number of Certified Intentional Transmitter Modules:

Please upload a block diagram.


Upload Image Save Continue
© 2020 - Eurofins E&E North America.