Arqa Staff Accommodation

MATERIAL SUBMITTAL – DX
- Split Units.

Mansour Battati

Senior App Eng & Consul Projects

# BM-21022023
Dated: 21-Feb-2023

© Copyright Johnson Controls, Inc. All rights reserved.


1 Johnson Controls, Inc. Proprietary and Confidential Information. Any unauthorized use, copying or
distribution is strictly prohibited.
CONTENT
Section
INQUIRY 1

Section
COMPLIANCE & SELECTION echnical Catalog 2

PRODUCT CATALOGUES & IOM Section


3

4
Section
Company Profile 4
Section 1
INQUIRY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

. CONTRACTOR SHALL COMPLY WITH


ALL THE NOTES.
A A
AIR COOLED CONDENSING UNIT SCHEDULE
APPLICABLE TO THIS PROJECT.
FAN COIL UNIT SCHEDULE (DX COIL) 1. FOR SYMBOLS, ABBREVIATIONS, GENERAL
NOTES, MATERIAL SPECIFICATION AND
TOTAL SENS TOTAL FRESH DX-HEAT TOTAL REFRIGERANT CONNECTION ELECT'L DATA AMBIENT STANDARD DETAIL REFER TO STANDARD
ELECT'L DATA POWER DETAILS & GENERAL DWGS.
E.S.P FAN EAT FAN REMARKS EQPT. NO. QTY. LOCATION CAP. TEMP. REMARKS
EQPT. NO. QTY. AREA SERVED CAP. CAP. AIR AIR PUMP RS RL (kW)
2. THIS DRAWING SHALL BE READ IN
(IN WG) WATTS PH °F DB/ °F WB SPEED (BTU/HR) V PH HZ (°F) CONJUCTION WITH THE DETAILS DRAWING
(BTU/HR) (BTU/HR) (CFM) (CFM) V HZ (BTU/HR) (IN) (IN) AND OTHER RELATED DESIGN DRAWINGS.
3. ALL THE CONDENSATE DRAIN FROM A/C
- 59 230 1 60 - 5,300 3 SPEED HIGHWALL EQUIPMENT SHALL BE TRAPED AND
FCU-01 10 AS PER DRAWING 9,925 9,152 415 - - ACU-01 10 AS PER DRAWING 9,925 1/2 1/4 1.233 230 1 60 120 - CONNECTED TO THE NEAREST FLOOR
DRAIN. CONTRACTOR SHOULD SHOW
B - CONDENSATE DRAIN PIPE IN SHOP
B
FCU-02 - - 13,660 12,030 610 - 0.30 - 230 1 60 - - 3 SPEED CEILING CONCEALED DRAWING.
ACU-02 - - 13,660 5/8 3/8 1.81 230 1 60 120 - 4. ALL SUPPLY & RETURN GRILLES, DIFFUSERS
- AND AIR OUTLETS FINAL LOCATION SHALL
FCU-03 58 AS PER DRAWING 14,875 14,781 710 - - 89 230 1 60 - 9,200 3 SPEED HIGHWALL BE VARIFIED WITH FINAL ID DESIGN.
5. BUILDER'S WORK REQUIREMENTS FOR HVAC
ACU-03 58 AS PER DRAWING 14,875 5/8 1/4 1.885 230 1 60 120 - AND PLUMBING EQUIPMENT SHALL BE
0.30 - 230 1 60 - - 3 SPEED CEILING CONCEALED COORDINATED WITH APPROVED
FCU-04 - - 15,790 13,950 625 - -
EQUIPMENTS FOR THE PROJECT.
6. ALL EQUIPMENTS SHALL BE INSTALLED
- 60 230 1 60 - 9,400 3 SPEED HIGHWALL ACU-04 - - 15,790 5/8 3/8 2.23 230 1 60 120 - STRICTLY IN ACCORDANCE WITH
FCU-05 9 AS PER DRAWING 17,250 16,834 735 - - MANUFACTURER'S RECOMMENDATIONS FOR
C PROPER OPERATION AND MAINTENANCE. C
0.30 - 230 1 60 - - 3 SPEED CEILING CONCEALED 7. ALL WORK ON SITE SHALL BE EXECUTED
FCU-06 - - 22,330 15,900 840 - - ACU-05 9 AS PER DRAWING 17,250 5/8 3/8 2.215 230 1 60 120 - STRICTLY IN ACCORDANCE WITH APPROVED
SHOP DRAWINGS, COORDINATED WITH ALL
- 89 230 1 60 - 7,100 3 SPEED HIGHWALL DISCIPLINE AND APPROVED
FCU-07 1 AS PER DRAWING 23,250 19,752 850 - - EQUIPMENTS & MATERIALS FOR THE
ACU-06 - - 22,330 3/4 3/8 2.81 230 1 60 120 - PROJECT.
- 8. ALL DUCTWORK DIMENSIONS, AS SHOWN IN
FCU-08 - - 26,000 19,600 1,040 - 0.35 - 230 1 60 - - 3 SPEED CEILING CONCEALED THE DRAWINGS, ARE INTERNAL CLEAR
DIMENSIONS AND DUCT SIZES SHALL BE
ACU-07 1 AS PER DRAWING 23,250 3/4 3/8 2.981 230 1 60 120 - INCREASED TO COMPENSATE FOR DUCT
- 73 230 1 60 - 12,000 3 SPEED HIGHWALL
FCU-09 10 AS PER DRAWING 25,650 22,667 950 - - LINING THICKNESS.
9. ALL AIR DEVICES BAR GRILLE & LINEAR SLOT
D DIFFUSERS SHALL BE INSTALLED IN D
0.35 - 230 1 60 - 16,200 3 SPEED CEILING CONCEALED ACU-08 - - 26,000 7/8 1/2 3.78 230 1 60 120 -
FCU-10 17 AS PER DRAWING 37,860 29,270 1,490 - - ACCORDANCE WITH MANUFACTURER
RECOMMENDATION FOR PROPER
OPERATIONS AND MAINTENANCE. COLOR
FINISHING SHALL BE IN ACCORDANCE WITH
ACU-09 10 AS PER DRAWING 25,650 3/4 3/8 3.265 230 1 60 120 - CLIENT/CONSULTANTS APPROVAL.
10. ALL EQUIPMENTS, PIPING, DUCTWORKS,
ETC., SHALL BE SUPPORTED AS DETAILED,
NOTES: SPECIFIED AND REQUIRED TO PROVIDE A
ACU-10 17 AS PER DRAWING 37,860 7/8 1/2 5.13 230 1 60 120 - VIBRATION FREE INSTALLATION.
11. FOR BMS & CONTROL SYSTEMS, REFER TO
1. FCU'S SHALL BE SELECTED BASED ON HIGH SPEED WITH MAX. NOISE LEVEL OF 35 NC IN ROOM. DRAWING NO. 000M012 UP TO 000M018.
E 2. ALL FCU'S SHALL BE PROVIDED WITH PERMANENT WASHABLE FILTER.
12. PROVIDE FLEXIBLE CONNECTIONS IN ALL
DUCTWORK SYSTEMS CONNECTED TO FANS,
E
FCU, AHU OR OTHER EQUIPMENTS WHICH
3. SPACE HEATING SHALL BE PROVIDED BY DX-HEAT PUMP SYSTEM. REQUIRE VIBRATION ISOLATION.
13. WHERE TWO OR MORE ITEMS OF THE SAME
NOTES: TYPE OF EQUIPMENT ARE REQUIRED, THE
PRODUCT OF ONE MANUFACTURER SHALL
BE USED.
1. UNIT SHALL BE SELECTED FOR 120 DEG. F. AMBIENT AND REQUIRED CAPACITY TO BE VERIFIED BY THE SUPPLIER. 14. PROVIDE ACCESS PANELS FOR
INSTALLATION IN WALLS & CEILINGS, WHERE
2. UNIT SHALL BE INSTALLED ON ANTIVIBRATION MOUNTS. REQUIRED, TO SERVE DAMPERS, VALVES,
SMOKE DETECTOR AND OTHER CONCEALED
3. UNIT SHALL BE INSTALLED STRICTLY IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS
F FAN SCHEDULE REFRIGERANT PIPE SIZE SHALL BE RESIZED IF NECESSARY AND ALL THE ACCESSORIES SHALL BE PROVIDED FOR PROPER
MECHANICAL EQUIPMENT. ACCESS PANELS
SHALL BE TURNED OVER TO GENERAL F
CONTRACTOR FOR INSTALLATION.
15. LOCATE ALL MECHANICAL EQUIPMENT (FCU,
FUNCTIONING OF THE UNITS.
ELECT'L DATA FAN CONTROL BOX, FD, MD, VALVES & ETC.)
AIR FLOW ESP POWER MOTOR FOR UNOBSTRUCTED ACCESS TO UNIT
EQPT. NO. QTY. AREA SERVED LOCATION RPM REMARKS 4. UNIT SHALL HAVE HEAVY DUTY CORROSION PROTECTION FINISH.
(CFM) (IN-WG) (HP) (HP) V PH HZ
ACCESS PANELS.
5. ALL OUTDOOR EQUIPMENT SHALL BE WEATHER PROOF AND LEAK TIGHT. 16. ALL SMOKE MANAGEMENT DUCT THAT ARE
NOT IN SEPARATE ENCLOSURE, FIRE RATED
FOR 2 HOURS ARE REQUIRED TO BE " 2
EF-01 41 WATER CLOSETS (BASEMENT 35, 1ST FLOOR 6) AS PER DRAWING 50 - 1.29 0.1 0.250 230 1 60 CASSETTE TYPE HOURS FIRE RATED DUCT "
17. PROVIDE AN AIR VENT AT THE HIGH POINT
OF EACH DROP IN CHILLED WATER AND ALL
PIPING SHALL GRADE TO LOW POINTS.
G 1 PROVIDE HOSE END DRAIN VALVES AT THE
G
EF-02 BASEMENT-STORAGE, GROUND-LC&LV, 1ST FLOOR-STORAGE AS PER DRAWING 200 - 1.32 0.2 0.250 230 1 60 DOME
AIR CURTAIN SCHEDULE BOTTOM OF ALL RISERS.
18. PROVIDE CHAIN WHEEL OPERATORS FOR
ALL VALVES IN EQUIPMENT. ROOM MOUNTED
EF-03 1 BASEMENT-MEP&STORAGE, GROUND-MEP, 1ST FLOOR-MEP AS PER DRAWING 200 - 1.38 0.2 0.250 230 1 60 DOME GREATER THAN 2.0 METER ABOVE FLOOR
UNIT SIZE AIR VOLUME MAXIMUM VELOCITY ELECT'L DATA LEVEL.
NOZZLE LENGTH POWER 19. EXTERIOR LOUVERS ARE INDICATED FOR
EQPT. NO. QTY. LxWxH LOW SPEED HIGH SPEED LOW SPEED HIGH SPEED REMARKS
EF-04 1 GROUND-TOILET AS PER DRAWING 300 - 1.31 0.2 0.250 230 1 60 DOME (M) (M) (kW) V PH HZ
INFORMATION ONLY. LOUVER SIZES,
(CFM) (CFM) (FPM) (FPM) LOCATIONS AND DETAILS SHALL BE
COORDINATED WITH THE GENERAL
CONTRACTOR.
EF-05 2 GROUND-WAREHOUSE AS PER DRAWING 350 - 1.33 2.67 3 230 1 60 INLINE ACR-1 6 0.9x0.21x0.23 0.90 370 440 2,560 2,185 0.10 230 1 60 -
H H

EF-06 1 GROUND-WAREHOUSE AS PER DRAWING 400 - 1.35 2.75 3 230 1 60 INLINE

EF-07 2 BASEMENT-WAREHOUSE AS PER DRAWING 500 - 1.51 3.07 5 400 3 60 INLINE NOTES:

1. ALL THE UNITS SHALL BE UL LISTED AND FAN SHALL BE AMCA APPROVED.
EF-08 1 BASEMENT-PUMP ROOM AS PER DRAWING 100 - 1.29 1.5 1.5 230 1 60 INLINE 2. ALL UNITS SHALL BE SUPPLIED WITH AUTOMATIC DOOR LIMIT SWITCH TO AUTOMATICALLY ACTIVATE THE UNIT
I I
EACH TIME THE DOOR IS OPENED.
SF-01 2 GROUND-WAREHOUSE AS PER DRAWING 350 - 1.01 3.06 5 400 3 60 INLINE 3. ALL UNIT SHALL HAVE ON/OFF SWITCH (MANUAL OVER RIDE) LOCATED AT WALL NEAR THE UNIT.

SF-02 1 GROUND-WAREHOUSE AS PER DRAWING 400 - 1.04 3.51 5 400 3 60 INLINE

SF-03 2 BASEMENT-WAREHOUSE AS PER DRAWING 500 - 1.31 4.37 5 400 3 60 INLINE

J J
SF-04 1 BASEMENT-WAREHOUSE AS PER DRAWING 400 - 1.04 3.51 5 400 3 60 INLINE

KEY PLAN:

NOTES:

1. ALL EF'S SHALL BE PROVIDED WITH BACKDRAFT DAMPER AND SPEED CONTROLLER.

K 2. ALL FANS SHALL HAVE FAN GUARDSAND ARCHITECTURAL EXTERNAL LOUVER. K


3. EXTERNAL STATIC PRESSURE IS APPROXIMATE, CONTRACTOR TO VERIFY AS PER ACTUAL CONDITION ON SITE.
KEY PLAN
4. FAN SELECTION SHALL BE BASED ON NOISE PRESSURE LEVEL NOT TO EXCEED NC 35 IN THE SUPPLIED SPACE OR
NOISE LEVEL REFLECTED TO OTHER SPACES.
5. ALL FANS ON ROOF SHALL HAVE MOTOR RATED @ 50°C

.
L L
KITCHEN VENTILATION SYSTEM SCHEDULE (ALL EQUIPMENT TO BE INSTALLED BY THE KITCHEN SPECIALIST)
SUPPLY (SUPPLY AIR FROM 100% F/A SUPPLY FANS) KVE ( KITCHEN VENTILATION EXHAUST) ELECT'L DATA REMARKS
AREA SERVED LOCATION QTY. AIR ESP POWER MOTOR AIR ESP POWER MOTOR APPROXIMATE HOOD SIZE NORTH DIRECTION
EQPT. NO. LOCATION EQPT. NO. LOCATION V PH HZ (MM)
(CFM) (IN-WG) (HP) (HP) (CFM) (IN-WG) (HP) (HP)

HOOD-1 KITCHEN 1 - - - - - - KVE-1 550 2.37 1.31 1.5 230 1 60 -


M b 90% SUBMISSION JAN 2023
M
a 50% SUBMISSION NOV 2022
No. Revision Add's Date

OWNER

NOTES:

1. KITCHEN HOOD SHALL BE DOUBLE SKIN STAINLESS STEEL CONSTRUCTION.


CONSULTANT

2. HOOD SHALL BE PROVIDED WITH GREASE FILTER, GREASE TRAP AND LIGHT.
N 3. FRESH AIR INTAKE FAN SHALL BE PROVIDED WITH 2" THICK WASHABLE FILTER.
N
4. EXHAUST AIR SHALL BE PROVIDED VIA ECOLOGICAL UNIT TO TREAT FULLY THE GREASE AND ODOR BEFORE DISCHARGED TO OUTDOOR.
5. EXHAUST AND INTAKE FAN SHALL BE INTERLOCKED WITH OPERATING CONTROL PANEL. PROJECT TITLE

6. HOOD SHALL BE PROVIDED WITH AUTOMATIC FIRE DETECTION AND FIRE EXTINGUISHING SYSTEM, UL LISTED WET CHEMICAL.
7. ALL EXHAUST DUCT RISERS IN SHAFT SHALL BE SUPPLIED & INSTALLED BY THE CONTRACTOR UP TO EXHAUST LOUVERS (INCLUSIVE) (PROVIDED BY CONTRACTOR). ARAQA STAFF ACCOMMODATION
8. BLACK STEEL GAGE 16, SHALL BE INSTALLED WITH CALCIUM SILICATE AND ALUMINUM JACKETING 0.6MM THICK.
FRESH AIR DUCT RISERS SHALL BE GALVANIZED STEEL (PROVIDED BY CONTRACTOR). LOCATION RIYADH, K.S.A PLOT NO. 000

P 8. HOOD MANUFACTURER SHALL VERIFY THE EXHAUST AIR AND SUPPLY AIR FLOW RATES ACCORDING TO HOOD SIZE AND
BLOCK 00 P
DRAWING TITLE

GUARANTEE THE HOOD PERFORMANCE.


EQUIPMENT SCHEDULE
EQUPMENT SCHEDULE
9. HOOD SHALL BE SELF CLEANABLE TYPE.
11. ESP SHALL BE VERIFIED BY THE CONTRACTOR.
NTS NAME DRAWING No.

DESIGNED S.Z.M
MH207
DEVELOPED M.A.S

CHECKED M.A.S PROJECT No.

RYD-22018
COORDINATED M.V.P

Q VERIFIED

DRAWN
M.V.P

M.V.P / F.T.M SCALE NTS


Q
APPROVED M.S.D DATE NOV 2022
50% SUBMISSION DRWG.SIZE

A0

1 2 3 4 5 6 7 8 9 10 13 14 15 16 17 18 19 20 21 22 23
Section 2
COMPLIANCE & SELECTION
Cooling Load On Coil Cooling Capacity ESP Off Coil
Amb. Temp ESP Altitude Model Power AirFlow
Total Sensible DB WB Total Sensible Max Rated DB WB
Unit Tag Qty Product Series Mode Fan Speed
Btu/hr F F Pa m Unit Btu/hr Kw Pa LPS F

FCU-1 10 Hiwall Frost HP 9,925 9,152 High 81 67 120.0 YJGE18XH3CHA-R4 / YJGE18YH3CHAO-4 15,715 13,836 1.83 - - 333 62.5 59.9
FCU-2 0 Hiwall Frost HP 13,660 12,030 High 81 67 120.0 YJGE18XH3CHA-R4 / YJGE18YH3CHAO-4 15,715 13,836 1.83 - - 333 62.5 59.9
FCU-3 58 Hiwall Frost HP 14,875 14,781 High 81 67 120.0 YJGE24XH3CHA-R4 / YJGE24YH3CHAO-4 19,054 16,010 2.25 - - 375 62.0 59.3
FCU-4 0 Hiwall Frost HP 15,790 13,950 High 81 67 120.0 YJGE24XH3CHA-R4 / YJGE24YH3CHAO-4 19,054 16,010 2.25 - - 375 62.0 59.3
FCU-5 9 Hiwall Frost HP 17,250 16,834 High 81 67 120.0 YJGE28XH3CHA-R4 / YJGE28YH3CHAO-4 23,513 19,945 2.70 - - 417 59.7 58.4
FCU-6 0 Hiwall Frost HP 22,330 15,900 High 81 67 120.0 YJGE28XH3CHA-R4 / YJGE28YH3CHAO-4 23,513 19,945 2.70 - - 417 59.7 58.4
FCU-7 1 Hiwall Frost HP 23,250 19,752 High 81 67 120.0 YJGE28XH3CHA-R4 / YJGE28YH3CHAO-4 23,513 19,945 2.70 - - 417 59.7 58.4
FCU-8 0 Hiwall Iceberg HP 26,000 19,600 High 81 67 120.0 YHGE36XT3CFE-R4 / YHGE36YT3CFEO-4 28,508 24,268 2.88 - - 611 63.3 60.0
FCU-9 10 Hiwall Iceberg HP 25,650 22,667 High 81 67 120.0 YHGE36XT3CFE-R4 / YHGE36YT3CFEO-4 28,508 24,268 2.88 - - 611 63.3 60.0
FCU-10 17 DSU Inverter HP 37,860 29,270 High 81 67 120.0 YEKE48BXL3CJ-W3 / YEKE48BYL3CJO-3 45,336 37,400 5.59 160 50 1,106 65.9 60.8
Project: Arqa Staff Accommodation
Subject: Compliance

Item No SPECS Clarification Remarks

PART 2 - PRODUCTS
2.3 CONCEALED EVAPORATOR-FAN COMPONENTS
A. Chassis: Galvanized steel with flanged edges, removable panels for servicing, and insulation on back of Comply with Remarks
panel. Indoor Unit: Galvanized Steel cabinet, without baked with foam insulation.
1. Insulation: Faced, glass-fiber duct liner.
2. Drain Pans: Galvanized Steel, with connection for drain; insulated with polystyrene. Access panels shall be provided for fan / motor maintenance. Comply

B. Refrigerant Coil: Copper tube, with mechanically bonded aluminum fins, complying with ARI 210/240, Comply with Remarks SASO Certified, Comply with CU-AL
and with thermal-expansion valve.
C. Fan: Forward-curved, double-width wheel of galvanized steel; directly connected to motor. Comply with Remarks Unit are equipped with high efficient DC motor

Motor must be compatible for variable frequencies operation. Comply with 3 speed fan as STD split
unit.
D. Fan Motor: Multispeed, PSC type. Comply with Remarks Unit are equipped with high efficient DC motor

Motor must be compatible for variable frequencies operation. Comply with 3 speed fan as STD split
unit.
E. Filters: 25 mm thick, permanent, washable, cleanable type in aluminum frames. Comply with Remarks Plastic Washable Filter.
F. Wiring Terminations: Connect motor to chassis wiring with plug connection. Not Comply
2.5 WALL- OR CEILING-MOUNTED, EVAPORATOR-FAN COMPONENTS
A. Cabinet: Enameled steel with removable panels on front and ends, and discharge drain pans with drain Comply with Remarks Casing is Hard compact Plastic Matirial.
connection.
B. Refrigerant Coil: Copper tube, with mechanically bonded aluminum fins, complying with ARI 210/240, Comply with Remarks SASO Certified, Comply with CU-AL
and with thermal-expansion valve. Comply with Thermal Expansion device.
C. Fan and Motor: Centrifugal fan, directly driven by multispeed, electric motor with integral overload Cross type indoor fan. Over Load protection not comply.
protection; resiliently mounted.
D. Filters: 25 mm thick, permanent, washable, cleanable type in aluminum frames. Comply with Remarks Plastic Washable Filter.
2.6 AIR-COOLED, COMPRESSOR-CONDENSER COMPONENTS
A. Casing: Steel, finished with baked enamel, with removable panels for access to controls, weep holes for Comply with Remarks Casing is made of GI material with powder coating on exterior surfaces wherever required with
water drainage, and mounting holes in base. Provide brass service valves, fittings, and gage ports on removable panel for access to controls. Weep holes for water on base.
exterior of casing.
Brass service with integral gauge ports on exterior of casing, fitting not YORK scope.
B. Compressor: Hermetically sealed with crankcase heater and mounted on vibration isolation. Comply with Remarks Ducted units :
Compressor motor shall have thermal- and current-sensitive overload devices, start capacitor, relay, 1. Cranckcase heater comply for 36 BTU UP TO 60 BTU units. external Thermal protection for
and contactor. Compressors are provided.
1. Compressor Type: Scroll 2. Rotary Type Compressor. DC inverter compressor and motor. High & Low Pressure switch for 36
2. Two-speed compressor motor with manual-reset high-pressure switch and automatic-reset low- BTU UP TO 60 BTU units.
pressure switch.
Hi-Wall Unit:
2. Cranckcase heater Not Comply.
Capacitors for Compressors are provided.
a. Rotary Type Compressor.
b. Constant Speed Compressors. High & Low Pressure switch Not Comply.

C. Refrigerant Coil: Copper tube, with mechanically bonded aluminum fins, complying with ARI 210/240, SASO Certified Cu- AL with Coating as per products catalogues.
and with liquid subcooler.
D. Fan: Aluminum-propeller type, directly connected to motor. Comply.
E. Motor: Permanently lubricated, with integral thermal-overload protection. thermal-overload protection
F. Mounting Base: Polyethylene. Comply with Remarks Mounting lags are integral of made up of GI material , rubber mounting provided by the contractor.

G. Unit efficiency should be more than or equal ASHRAE 90.1 latest edition or SASO 2663 latest edition As per SASO Certificates.
whichever more strength.
2.7 ACCESSORIES
Project: Arqa Staff Accommodation
Subject: Compliance

Item No SPECS Clarification Remarks


A. Thermostat: [Wireless infrared functioning to remotely control compressor and evaporator fan, with Comply Remote control for Hi-Wall units.
the following features:
1. Compressor time delay. BMS not Comply.
2. 24-hour time control of system stop and start.
3. Liquid-crystal display indicating temperature, set-point temperature, time setting, operating mode,
and fan speed.
4. Fan-speed selection, including auto setting].
5. Interface with BMS if Required
B. Automatic-reset timer to prevent rapid cycling of compressor. Comply
C. Refrigerant Line Kits: Soft-annealed copper suction and liquid lines factory cleaned, dried, pressurized, Not YORK scope.
and sealed; factory-insulated suction line with flared fittings at both ends.
Section 3
Catalogues & IOM
FROST HIGH WALL R-410A 60HZ TROPICAL HEAT PUMP
YJGE 18 to 28 ZH3CHAOR4
A complete range from 18,000 to 27,400 Btu/h
FROST HIGH WALL R-410A 60HZ TROPICAL HEAT PUMP

Indoor Unit
• Modern, compact design
• Efficient cooling& heating
• Auto restart
• Low noise
• 3D Air Flow
• Blue Fin 18~24K

Remote Control
• 5 operation modes
• Sleep mode and on/off timers
• Turbo cool settings
• LED display

Condensing Unit
28K
• Quiet operation
• High efficiency
• Convenient installation
• Easy maintenance
• Valve protection cover
• Blue Fin

The YORK ® line of Mini Splits Air Conditioners includes a wide range of sizes
to give you more flexibility in your product offering. Each model is designed to
provide comfort and efficiency, in an easy-to-operate unit and the sleek design
fits a variety of spaces, whether it’s in a home or office. Models meet the highest
energy efficiency ratings, so less energy is consumed without sacrificing comfort
and performance. Both the condensing units and indoor units are engineered for
quiet operation. And comfort control settings are easily changed with the touch of a
button on the remote control.

2
FROST HIGH WALL R-410A 60HZ TROPICAL HEAT PUMP

Features and Benefits

Turbo Mode 3-Minute Protection


Provides quicker cooling/heating with one press of A 3-minute delay before the compressor will
the remote button. restart helps avoid compressor damage and
work time.

Child Lock Self Diagnosis


If the lock button on the remote control is pressed, Clearly displayed failure codes allow for quicker
it must be pressed again before use to help prevent troubleshooting and easier maintenance.
accidental operation.

Multi-Speed Fan R-410A


Multi-speed fan helps satisfy various airflow Environment-friendly refrigerant cools and heats
requirements. more efficiently without destroying the ozone
layer.

Auto Restart 24-Hour Timer


Unit is automatically returned to previous Allows programmed start times up to 24 hours
operating conditions after a power outage, for in advance for flexible and more convenient
simplified operation. operation.

High Ambient Cooling at 52°C


The AC will run in cooling mode when outdoor
temperature is as high as 52°C to meet special
user-requested applications.

Peak in the outdoor temperature


Capabilities % 100
Intelligent Sleep Mode
Load % 50 Air temperature is automatically controlled accord-
ing to the sleep curve for maximum comfort, reduced
noise, and energy savings.
8hrs 9 hrs
db(A) 0 Intelligent Night operation function can reduce noise
Operation 48 up to 5dB/A.
Night Mode
lower 5dB/A than normal
43
Night Mode Starts Night Mode Ends
8:00 12:00 20:00 0:00 4:00 8:00

3
Specification
York Set Model YJGE18ZH3CHAOR4 YJGE24ZH3CHAOR4 YJGE28ZH3CHAOR4
York Outdoor Model YJGE18YH3CHAO-4 YJGE24YH3CHAO-4 YJGE28YH3CHAO-4
York Indoor Model YJGE18XH3CHA-R4 YJGE24XH3CHA-R4 YJGE28XH3CHA-R4
Power supply V/Ph/Hz 230V/1PH/60Hz 230V/1PH/60Hz 230V/1PH/60Hz
Power supply by Indoor Outdoor Outdoor
Capacity Btu/h 18,000/15,300 22,000/19,000 27,400/23,200
Capacity W 5,280/4,470 6,450/5,580 8,050/6,780
Power Input W 1,481/1789 1,811/2222 2,283/2682
Cooling @ T1/T3
Rated current A 6.5/7.80 7.9/9.7 10.0/11.8
EER Btu/h·W 12.15/8.55 12.15/8.550 12.00/8.650
EER W/W 3.56/2.51 3.56/2.51 3.52/2.54
Capacity Btu/h 18,000 22,000 27,400
Capacity W 5300 6,450 8,050
Power Input W 1,507 1,792 2,231
Heating
Rated current A 6.6 7.80 9.80
COP Btu/h.W 11.95 12.28 12.28
COP W/W 3.5 3.600 3.600
Max. Power Input W 2,200 2,600 3,100
Max. current A 9.57 11.3 13.6
Moisture Removal l/h 2.0 2.4 3.0
Power Output W 40 70 70
Indoor fan motor
Speed (SH/Hi/Me/Lo) rpm 1,300/1,100/1,000/900 1,350/1,150/1,050/950 1,300/1,200/1,100/1,000
Indoor air flow(SH) m3/h 1,200 1,350 1,500
Indoor sound pressure level (Hi/Me/Lo) @ Distance 1m dB(A) 47/44/40 49/46/43 50/47/44
Unit (WxHxD) mm 997x322x230 1,115x336x248 1,316x365x275
Indoor dimension
Packing (WxHxD) mm 1,085x403x329 1206x418x342 1,418x478x402
Net kg 12.5 16 21
Indoor weight
Gross kg 16 19.5 25
Type Rotary Rotary Rotary
Rated current(RLA) A 6.35 8.2 10
Locked rotor Amp(LRA) A 36 44 44
Compressor
Thermal protector Internal Internal Internal
Capacitor μF 30 35 50
Refrigerant oil/oil charge ml α68HES-H/480 α68HES-H/570 α68HES-H/570
Power Output W 80 80 80
Outdoor fan motor Capacitor μF 6 6 6
Speed rpm 850 820 820
Outdoor air flow m3/h 3800 3800 3800
Outdoor sound pressure level @ Distance 1m dB(A) 56 58 62
Outdoor dimension Unit/Packing (WxHxD) mm 890x697x353/1,046x780x460 890x697x353/1,046x780x460 920x762x385/1,085x843x487
Net kg 51 55 63
Outdoor weight
Gross kg 55 60 69
Type R410A R410A R410A
Refrigerant
Charge g 1,700 1,750 2,280
Liquid Line/Suction Line mm(Ø) 6.35/12.7 6.35/15.88 9.52/15.88
Standard connection length m 5 5 5
Refrigerant pipe Additional charge per meter g/m 20x(Length m-5) 20x(Length m-5) 50x(Length m-5)
Max. refrigerant pipe length m 25 25 25
Max. difference in level m 15 15 15
Operation temperature range °C 16-30 16-30 16-30
Ambient temperature range °C 21-52 21-52 21-52
Qty per 20'/40'/40'HQ Set 55/110/120 50/105/115 40/80/90
Nominal testing conditions @T1:
Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 95°F DB / 75.2°F WB (35°C DB / 24°C WB)
Heating - Indoor 68°F DB / 59°F WB (20°C DB / 15°C WB) & Outdoor 44.6°F DB / 42.8°F WB (7°C DB / 6°C WB)
Nominal testing conditions @T3:
Cooling - Indoor 84.2°F DB / 66.2°F WB (29°C DB / 19°C WB) & Outdoor 114.8°F DB / 75.2°F WB (46°C DB / 24°C WB)
*This product is coming with holding refrigerant charge from the factory. Refrigerant charge must be checked before startup to assure design performance.

Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other
trademarks used herein may be trademarks or registered trademarks of other companies.
FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM
© 2020 Johnson Controls, Inc, P.O. Box 423, Milwaukee, WI 53201, All rights reserved worldwide. PUBL-4342(0320)


Installation Manual New Released Form: AJFEH3CHAO-4-191203

High Wall Tropical


R-410A 60Hz 230V

YJFE18YH3CHAO-4
YJGE18YH3CHAO-4
YJFE24YH3CHAO-4
YJGE24YH3CHAO-4
YJFE28YH3CHAO-4
YJGE28YH3CHAO-4

Issue Date
Dec, 2019

0010592014
Installation Manual of Room Air Conditioner
Preparation

Necessary Tools for Installation Selection of Installation Place


Appliance accessible to the general public.
Driver Torque wrench
Nipper (17mm,22mm,26mm) Indoor Unit
Hacksaw Pipe cutter Place, robust not causing vibration, where the body can be supported suf ciently.
Hole core drill Flaring tool Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
Spanner(17,19 and 26mm) Knife unit are not disturbed.
Gas leakage detector or Measuring tape Place, possible to drain easily, where piping can be connected with the outdoor unit.
soap-and-water solution Reamer Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
Power Source and uorescent lamps can be left.
In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the uorescent lamps in the room are lightened.
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate. Outdoor Unit
Install an exclusive branch circuit of the power. Place, which is less affected by rain or direct sunlight and is suf ciently ventilated.
A receptacle shall be set up in a distance where the power cable can be Place, possible to bear the unit, where vibration and noise are not increased.
reached. Do not extend the cable by cutting it. Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked is available as illustrated in the above gure.

Drawing for the installation of indoor and outdoor units


The models adopt HFC free refrigerant R410A Accessory parts
Attention must be paid to
the rising up of drain hose Number
more than 15cm No. Accessory parts of
articles

1 Remote controller 1

2 2
R-03 dry battery

more than G 3 1
10cm Mounting plate

4 1
Drain hose

4X50
Arrangement of piping 5 Steel nail, cement
6
directions
more than 10cm
6 4X25 Plastic cap
4
Rear left F Screw
Left Rear A
right 7 1
Drain-elbow

Right 8 Cover 1
C
Below
9 Cushion 4

more than10cm 10 1
Pipe supporting plate
more than 30cm
11 Connecting cable 1
The marks from A to
G in the gure are the 1.Cooling only units don't have
parts numbers. Drain-elbow
The distance between 2.Accessory parts may vary from
the indoor unit and the D
each model, pls refer to the
oor should be more actual parts.
than 2m. E
Optional parts for piping
more than 200cm
A Non-adhesive tape
B Adhesive tape

more than 50cm C Saddle (L.S) with screws


Please be subject to the actual product purchased , the above picture is just for your reference. Connecting electric cable
D
for indoor and outdoor
E Drain hose
F Heating insulating material
Read this manual before installation
Explain suf ciently the operating means to the user according to this manual G Piping hole cover

0011503597
3 Installation of the Indoor Unit

Drawing of pipe

256

364
140 500 140 130 628 130
Floor fixing dimensions
[ Rear piping ]
Floor fixing dimensions Draw pipes and the drain hose, then fasten them with the adhesive tape
of the outdoor unit of the outdoor unit
(Unit:mm) (Unit:mm) [ Left・Left-rear piping ]
12K 18/24K In case of left side piping, cut away, with a nipper, the lid for left piping.
In case of left-rear piping, bend the pipes according to the piping direction to
the mark of hole for left-rear piping which is marked on heat insulation materials.

1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it
400

out on the front side, then connect them.


3. Coat the aring seal face with refrigerant oil and connect pipes.
129 660 129
Cover the connection part with heat insulation materials closely, and make sure
Floor fixing dimensions xing with adhesive tape
of the outdoor unit
(Unit:mm) Heat insulation Piping
material

30K Pipe supporting


plate
Lid for right Drain hose
piping
Lid for left piping
12k,18k, 24k,30k ---- expressed in the manual indicate the capacity of the Lid for under piping pipe
Indoor/outdoor electric cable
appliance, and represent
Fix with adhesive tape

Indoor/outdoor electric cable and drain hose must be bound with refrigerant
Selection of pipe piping by protecting tape.

For 12K For 18K For 24K For 30K


[ Other direction piping ]
Cut away, with a nipper, the lid for piping according to the piping direction and
Liquid pipe ( ) 6.35mm(1/4") 6.35mm(1/4") 6.35mm(1/4") 9.52mm(3/8") then bend the pipe according to theposition of wall hole. When bending, be
Gas pipe ( ) careful not to crash pipes.
9.52mm(3/8") 12.7mm(1/2") 15.88mm(5/8") 15.88mm(5/8")
Connect beforehand the indoor/outdoor electric cable, and then pull out the
NOTE The thickness of the pipe must be 0.8mm at least. connected to the heat insulation of connecting part specially.
Indoor unit
Fixing the indoor unit body
1 Fitting of the Mounting Plate and Positioning of the wall Hole

When the mounting plate is rst xed Hang surely the unit body onto the upper notches of the
1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate mounting plate. Move the body from side to side to verify its
secure xing.
to be xed against the wall, then temporarily fasten the plate with one steel nail.
In order to x the body onto the mounting plate,hold up
2. Make sure once more the proper level of the plate, by hanging a thread with a
the body aslant from the underside and then put it down
weight from the central top of the plate, then fasten securely the plate with the perpendicularly. mounting plate
attachment steel nail.
3. Find the wall hole location A using a measuring tape

B= Unloading of indoor unit body


Pay attention to the following points before installation
A=140
of machine:
30K
30mm

mm
1. Take out cushion blocks on When you unload the indoor unit,please use
the left and right angle beads
B= as shown in the following your hand to arise the body to leave agraffe,
Figure.
then lift the bottom of the body outward
slightly and lift the unit aslant until it
24K A=113 2. Remove 2 gaskets under the
leaves the mounting plate.
30mm

mm cross-flow fan.

3. Clean the burr on the surface of fracture to avoid the power agraffe mounting plate
B= wire from being scratched after removing the virtual opening
of the outgoing line slot on the case by hands in indoor
power-on process.
18K
A=113
mm 4 Connecting the indoor/outdoor Electric Cable
30mm

B= Remove terminal cover at right bottom corner of indoor unit, then take off wiring
cover by removing its screws.
A=145
30mm

12K mm Insert from outside the room cable into left side of the wall hole, in which the
pipe has already existed.
When the mounting plate is xed side bar and lintel
Pull out the cable on the front side, and connect the cable making a loop.
Fix to side bar and lintel a mounting bar, Which is separately sold, and then Insert the cable from the back side of the unit, then pull it out on the front side.
fasten the plate to the xed mounting bar. Loosen the screws and insert the cable ends fully into terminal block, then
Refer to the previous article, “ When the mounting plate is rst xed “, for the tighten the screws.
position of wall hole. Pull the cable slightly to make sure the cables have been properly inserted and
tightened.
2 Making a Hole on the Wall and Fitting the Piping Hole Cover After the cable connection, never fail to fasten the connected cable with the
wiring cover.
Make a hole of 60 mm in diameter, slightly descending to outside the wall.
Install piping hole cover and seal it off with putty after installation

Indoor side Outdoor side

Wall hole

(Section of wall hole) Note When connecting the cable, con rm the terminal number of indoor and
G Piping hole pipe outdoor units carefully. If wiring is not correct, proper operation can not
be carried out and will cause defect.

2
Outdoor unit
Power cable: 1 Installation of Outdoor Unit
3G1.5mm2
Install according to Drawing for the installation of indoor and outdoor units
G

3G1.5mm2 2 Connection of pipes

To bend a pipe, give the roundness as large as possible not to crush the pipe ,
Indoor unit and the bending radius should be 30 to 40 mm or longer.
Outdoor unit Connecting the pipe of gas side rst makes working easier.
The connection pipe is specialized for R410A.
12K/18 Cooling&Heating
Half union Flare nut Forced fastening without careful centering may
damage the threads and cause a leakage of gas.

Pipe Diameter( ) Fastening torque


Power cable: Liquid side6.35mm(1/4") 18N.m
3 4

3G1.5mm2 Liquid/Gas side9.52mm(3/8") 42 N.m


Gas side 12.7mm(1/2") 55N.m
COMP N1
1(L) 2(N)

2 Spanner Torque wrench Gas side 15.88mm(5/8") 60 N.m


3G1.5mm
Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.
The standard pipe length is 5m. If it is over 7m, the function of the unit will be
Indoor unit Outdoor unit affected. If the pipe has to be lengthened, the refrigerant should be charged,
according to 20 g/m. But the charge of refrigerant must be conducted by profes-
sional air conditioner engineer. Before adding additional refrigerant, perform air
12K/18K Cooling purging from the refrigerant pipes and indoor unit using a vacuum pump,then
charge additional refrigerant.
CAUTION
Outdoor unit
5

Power cable:
4

B Indoor unit
≥3G2.5mm B
3

A
4G1.0mm 2G0.75mm
Indoor unit
A
or
2

2 2
3G0.75mm 3G1.0mm Outdoor unit

Max.Elevation: Amax=15m
1

Outdoor unit In case the elevation A is more


Indoor unit than 5m, oil trap shoud be
installed every 5~7m
B Oil trap Max. Length: Bmax=25m
In case the pipe length B is
24/30KCooling&Heating Outdoor unit A
Indoor unit more than 7m, if the liquid pipe
diameter is 6.35mm the refrigerant
BR
should be charged, according to 20g/m
;if the liquid diameter is 6.35mm the
L

BL
POWER refrigerant should be charged,
N

SUPPLY Y/G according to 50g/m

3 Connection
Use the same method on indoor unit. Loosen the screws on terminal block and
5

insert the plugs fully into terminal block, then tighten the screws.
Power cable: Insert the cable according to terminal number in the same manner as the indoor
4

≥3G2.5mm unit.
3

If wiring is not correct, proper operation can not be carried out and controller
4G1.0mm2
may be damaged.
or
2 Fix the cable with a clamp.
2

4G1.5mm
4 Attaching Drain-Elbow
1

Indoor unit If the drain-elbow is used,


please attach it as gure. (Note:
Only for heat pump unit.)
24/30KCooling Outdoor unit
5 Purging Method:To use vacuum pump
BR
L

POWER
BL 1. Detach the service port’s cap of3-way valve, the valve rod’s cap for 2-way valve
N

SUPPLY Y/G and 3-way’s, connect the service port into the projection of charge hose (Iow)
for gaugemanifold. Then connect the projection of charge hose (center) for gau-
gemanifold into vacuum pump.

1. If the supply cord is damaged, it must be replaced by the manufacturer or its 2. Open the handle at Iow in
gaugemanifold, operate vacuum pump. If the scale-
service agent or a similar quali ed person. The type of connecting wire is moves of gause (Iow) reach vacuum condition in a moment, check 1. again.
H05RN-F or H07RN-F. 3. Vacuumize for over 15min.And check the level gauge which should read -0.1MPa
2. If the fuse on PC board is broken please change it with the type of (76 cm Hg) at Iow pressure side. After the completion of vacuumizing, close the
T. 3.15A/250V. handle ‘Lo’ in gaugemanifold and stop the operation of the vacuum pump. Check
3. The wiring method should be in line with the local wiring standard. condition of the scale and hold it for 1-2min. If the scale-moves back in spite of
4. After installation, the power plug should be easily reached.
tightening, make aring work again, the return to the beginning of 3 .
5. A breaker should be incorporated into xed wiring. The breaker should be
all-pole switch and the distance between its two contacts should be not less 4. Open the valve rod for the 2-way valve to an angle of anticlockwise 90 degrees.
than 3mm. After 6 seconds, close the 2-way valve and make the inspection of gas leakage.

3
5. No gas leakage? 3 On Drainage
In case of gas leakage, tighten parts of pipe connection. If
leakage stops, then proceed 6. steps ƽ Please install the drain hose so as to be downward slope without fail.
ƽ Please don’t do the drainage as shown below.
If it does not stop gas leakage, discharge whole refrigerants from the service
port. After Àaring work again and vacuumize, ¿ll up prescribed
refrigerant from the gas cylinder. Less than
5cm
6. Detach the charge hose from the service port, open 2-way valve and 3-way. Turn
the valve rod anticlockwiseuntil hitting lightly. It becomes The end is imm- It waves. The gap with the There is the bad
high midway. ersed in water. ground is too smal smell from a ditch
7.To prevent the gas leakage, turn the service port’s cap, the valve rod’s cap for 2-way
valve and 3-way’s a little more than the point where the torque increases suddenly.
ƽ Please pour water in the drain pan of the indoor unit, and con¿rm that drainage
8. After attaching the each caps, check the gas leakage around the caps. is carried out surely to outdoor.
ƽ In case that the attached drain hose is in a room, please apply heat insulation to
it without fail.
Step 1. Step 2.
2-way valve Liquid Side
3-way valve Gas Side Open

Gaugemanifold(for R410A)
Ƶ Refrigerant charge label
Anti countercurrent joint
Step 3. Contains fluorinated greenhouse gases
covered by the Kyoto Protocol A
Close
Tube(for R410A)
Vacuum pump(for R410A) R410A 1= kg
B
2 2= kg
Step 4. Step 6. 2-way valve C
2-way valve 1
3-way valve
3-way valve 1+2= kg
O D
Open 90
F E

This product contains fluorinated greenhouse gases covered by


the Kyoto Protocol. Do not vent into the atmosphere.
2-way valve Refrigerant type:R410A
2-way valve Step 7. GWP* value:1975
3-way valve
GWP=global warming potential
3-way valve
Please fill in with indelible ink,
‡WKHIDFWRU\UHIULJHUDQWFKDUJHRIWKHSURGXFW
‡WKHDGGLWLRQDOUHIULJHUDQWDPRXQWFKDUJHGLQWKHILHOGDQG
Valve rod cap
‡WKHWRWDOUHIULJHUDQWFKDUJH
Valve rod cap on the refrigerant charge label supplied with the product.
Service port cap The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop value cover).
A contains fluorinated greenhouse gases covered by the Kyoto
Protocol
CAUTION
c B factory refrigerant charge of the product: see unit name plate
ƽ If the refrigerant of the air conditioner leaks, it is necessary to discharge all the C additional refrigerant amount charged in the field
refrigerant. Vacuumize ¿rst, then harge the liquid refrigerant into air conditio- D total refrigerant charge
ner according to the amount marked on the name plate. E outdoor unit
ƽ Please do not let other cooling medium, except speci¿ed one (R410A), or air F refrigerant cylinder and manifold for charging
enter into the cooling circulation system. Otherwise, there will be abnormal
high pressure in the system to make it crack and lead to personal injuries.

1 Power Source Installation


ƽ The power source must be exclusively used for air conditioner. (Over I0A) Ƶ Check for Installation and Test Run
ƽ In the case of installing an air conditioner in a moist place, please install an ea-
rth leakage breaker. Ƶ Please kindly explain to our customers how to operate
ƽ For installation in other places, use a circuit breaker as far as possible. through the instruction manual.
2 Cutting and Flaring Work of Piping Check Items for Test Run
ƽ Pipe cutting is carried out with a pipe cutter and burs must be removed. Put check mark in boxes
ƽ After inserting the Àare nut, Àaring work is carried out.
Gas leak from pipe connecting?
Flare tool for R410A Conventional Àare tool Heat insulation of pipe connecting?
Are the connecting wirings of indoor and outdoor ¿rmly
Clutch-type clutch-type(Rigid-type) Wing-nut type (Imperial-type) inserted to the terminal block?
A 0~0.5mm 1.0~1.5mm 1.5~2.0mm Is the connecting wiring of indoor and outdoor ¿rmly ¿xed?
Is drainage securely carried out?
Flare tooling die 1.Cut pipe 2.Remove burs Is the earth line securely connected?
Is the indoor unit securely ¿xed?
Is power source voltage abided by the code?
Is there any noise?
Is the lamp normally lighting?
Are cooling and heating (when in heat pump) performed normally?
Is the operation of room temperature regulator normal?
3.Insert the Àare nut 4.Flare pipe

Correct Incorrect

Lean Damage of Àare Crack Partial Too outside

4
Models and specification
Model name Set 18K Cooling 18K Cooling&Heating

Power supply V/Ph/Hz 230/1/60 230/1/60

Capacity Btu/h 18000 18000

Input W 1481 1481


T1 Cooling
Rated current A 6.5 6.5

EER (Btu/h)/W 12.150 12.150

Capacity Btu/h 15300 15300

Input W 1789 1789


T3 Cooling
Rated current A 7.8 7.8

EER (Btu/h)/W 8.550 8.550

Capacity W / 5300

Input W / 1507
Heating
Rated current A / 6.6

COP W/W / 3.500

Star Rating 7 7

Max. input consumption W 2200 2200

Max. current A 9.57 9.57

IP IPX0 IPX0

Indoor Net weight kg 12.5 12.5

Gross weight kg 15.5 15.5

IP IPX4 IPX4

Outdoor Net weight kg 50.0 52.5

Gross weight kg 54.0 55.0

Ref rigerant Ty pe R410A R410A

Ref rigerant Charge g 1380 1700

Operating Pressure Mpa HP:4.15 LP:1.66 HP:4.15 LP:4.15

Tips:The nameplate nominal value is tested in the method as below


Cooling capacity test:Step 1,press the button "ON/OFF";step 2,press the button "COOL";step
3,press the button "TURBO".
Heating capacity test:Step 1,press the button "ON/OFF";step 2,press the button "HEAT";step
3,press the button "TURBO".
Models and specification

Model name Set 24K Cooling 24K Cooling&Heating

Power supply V/Ph/Hz 230/1/60 230/1/60

Capacity Btu/h 22000 22000

Input W 1811 1811


T1 Cooling
Rated current A 7.9 7.9

EER (Btu/h)/W 12.150 12.150

Capacity Btu/h 19000 19000

Input W 2222 2222


T3 Cooling
Rated current A 9.7 9.7

EER (Btu/h)/W 8.550 8.550

Capacity W / 6450

Input W / 1792
Heating
Rated current A / 7.8

COP W/W / 3.600

Star Rating 7 7

Max. input consumption W 2600 2600

Max. current A 11.3 11.3

IP IPX0 IPX0

Indoor Net weight kg 16.5 16.5

Gross weight kg 19.5 19.5

IP IPX4 IPX4

Outdoor Net weight kg 52.5 53.5

Gross weight kg 55.5 56.5

Ref rigerant Ty pe R410A R410A

Ref rigerant Charge g 1750 1750

Operating Pressure Mpa HP:4.15 LP:1.66 HP:4.15 LP:4.15

Tips:The nameplate nominal value is tested in the method as below


Cooling capacity test:Step 1,press the button "ON/OFF";step 2,press the button "COOL";step
3,press the button "TURBO".
Heating capacity test:Step 1,press the button "ON/OFF";step 2,press the button "HEAT";step
3,press the button "TURBO".
Models and specification

Model name Set 30K Cooling 30K Cooling&Heating

Power supply V/Ph/Hz 230/1/60 230/1/60

Capacity Btu/h 27400 27400

Input W 2283 2283


T1 Cooling
Rated current A 10.0 10.0

EER (Btu/h)/W 12.00 12.00

Capacity Btu/h 23200 23200

Input W 2682 2682


T3 Cooling
Rated current A 11.8 11.8

EER (Btu/h)/W 8.65 8.65

Capacity W / 8050

Input W / 2231
Heating
Rated current A / 9.8

COP W/W / 3.60

Star Rating 7 7

Max. input consumption W 3100 3100

Max. current A 13.6 13.6

IP IPX0 IPX0

Indoor Net weight kg 19.5 19.5

Gross weight kg 24.0 24.0

IP IPX4 IPX4

Outdoor Net weight kg 60.5 62.5

Gross weight kg 67.5 69.0

Ref rigerant Ty pe R410A R410A

Ref rigerant Charge g 2280 2280

Operating Pressure Mpa HP:4.15 LP:1.66 HP:4.15 LP:4.15

Tips:The nameplate nominal value is tested in the method as below


Cooling capacity test:Step 1,press the button "ON/OFF";step 2,press the button "COOL";step
3,press the button "TURBO".
Heating capacity test:Step 1,press the button "ON/OFF";step 2,press the button "HEAT";step
3,press the button "TURBO".
Models and specification

Model name Set 12K Cooling 12K Cooling&Heating

Power supply V/Ph/Hz 230/1/60 230/1/60

Capacity Btu/h 12600 12600

Input W 1037 1037


T1 Cooling
Rated current A 4.6 4.6

EER (Btu/h)/W 12.15 12.15

Capacity Btu/h 10500 10500

Input W 1253 1253


T3 Cooling
Rated current A 5.5 5.5

EER (Btu/h)/W 8.40 8.40

Capacity W / 3450

Input W / 691
Heating
Rated current A / 4.2

COP W/W / 3.60

Star Rating 7 7

Max. input consumption W 1500 1500

Max. current A 6.59 6.59

IP IPX0 IPX0

Indoor Net weight kg 11.5 11.5

Gross weight kg 13.5 13.5

IP IPX4 IPX4

Outdoor Net weight kg 33.5 34.0

Gross weight kg 36.5 37.0

Ref rigerant Ty pe R410A R410A

Ref rigerant Charge g 1050 1110

Operating Pressure Mpa HP:4.15 LP:1.66 HP:4.15 LP:4.15

Tips:The nameplate nominal value is tested in the method as below


Cooling capacity test:Step 1,press the button "ON/OFF";step 2,press the button "COOL";
step 3,press the button "TURBO".
Heating capacity test:Step 1,press the button "ON/OFF";step 2,press the button "HEAT";
step 3,press the button "TURBO".
2019 Doc No.: AJFEH3CHAO-4-191203
2019 Doc No.: AJFEH3CHAO-4-191203
ϑϳέλΗϟ΍Ωϧϋ 3 ˮίΎϏΏϳέγΗΩΟϭϳϻ .5
ΏϭΑϧϷ΍ΔϠλϭ˯΍ίΟ΃ρΑέϡϛΣ΃ˬίΎϏΏϳέγΗΩϭΟϭΔϟΎΣϲϓ
ϝρόΗϳϥ΃ϥϭΩϝϔγϸϟ΍ ˱έΩΣϧϣϥϭϛϳΙϳΣΑϑϳέλΗϟ΍ϡϭρέΧΏϳϛέΗϰΟέϳ Ș 6ΓϭρΧϟ΍ϰϟ·ϊΑΎΗϓˬΏϳέγΗϟ΍ϑϗϭΗ΍Ϋ·
ϩΎϧΩ΃΢οϭϣϭϫΎϣϛϑϳέλΗϟ΍ϡΩϋϰΟέϳ Ș
ΔϧΎϳλϟ΍ΫϔϧϣϥϣΎϬϠϣϛ΄ΑΩϳέΑΗϟ΍Ω΍ϭϣϑϳέλΗΑϡϗˬίΎϐϟ΍ΏϳέγΗϑϗϭΗϳϡϟ΍Ϋ·
ίΎϐϟ΍Δϧ΍ϭργ΃ϥϣΔϓϭλϭϣϟ΍ΩϳέΑΗϟ΍ΓΩΎϣΊΑϋˬϯέΧ΃ΓέϣώϳέϔΗϟ΍ϭΞϳϠϔΗϟ΍ΩόΑ
ϡγ5ϥϣϝϗ΃

ϲΛϼΛϟ΍ϡΎϣλϟ΍ϭϲ΋ΎϧΛϟ΍ϡΎϣλϟ΍΢Ηϓ΍ˬΔϧΎϳλϟ΍ΫϔϧϣϥϣϑϳέλΗϟ΍ϡϭρέΧϙϔΑϡϗ .6
νέϷ΍ϊϣΓϭΟϔϟ΍ ΝϭϣΗϳ έϭϣϐϣϑέρϟ΍ Ύ˱ϳϟΎϋ΢Αλϳ ϑϳϔΧϝϛηΑΏέοϳϥ΃ϰϟ·ΔϋΎγϟ΍ΏέΎϘϋαϛϋϡΎϣλϟ΍ΏϳοϗέΩ΃
ΔϬϳέϛΔΣ΋΍έΩΟϭΗ
ϑέλϣϥϣ ΍˱ΩΟΓέϳϐλ ˯Ύϣϟ΍ϲϓ ϑλΗϧϣϟ΍ϲϓ
ΔρϘϧϟ΍ϥϣ˱ϼϳϠϗέΛϛ΃ϲΛϼΛϟ΍ϡΎϣλϟ΍ϭϲ΋ΎϧΛϟ΍ϡΎϣλϠϟϡΎϣλϟ΍Ώϳοϗ˯ΎρϏˬΔϧΎϳλϟ΍Ϋϔϧϣ˯ΎρϏέΩ΃ˬίΎϐϟ΍ΏέγΗϊϧϣϟ .7

ΝέΎΧϠϟϑϳέλΗϟ΍˯΍έΟ·ϥϣΩϛ΄ΗϭˬΔϳϠΧ΍Ωϟ΍ΓΩΣϭϠϟϑϳέλΗϟ΍˯Ύϧ·ϲϓ˯Ύϣϟ΍ΏϛγϰΟέϳ Ș ΊΟΎϔϣϝϛηΑϥ΍έϭΩϟ΍ϡίϋΎϫΩϧϋΩ΍ΩίϳϲΗϟ΍

ΔϳρϏϷ΍ϝϭΣίΎϐϟ΍ΏϳέγΗϥϣϕϘΣΗˬΔϳρϏϷ΍ΏϳϛέΗΩόΑ8
΄ρΧϥϭΩϪϳϠϋϱέ΍έΣϟ΍ϝίόϟ΍ϕϳΑρΗϰΟέϳˬΔϓέϏϲϓ΍˱ΩϭΟϭϣϕΣϠϣϟ΍ϑϳέλΗϟ΍ϡϭρέΧϥΎϛϝΎΣϲϓ Ș
2ΓϭρΧϟ΍ 1ΓϭρΧϟ΍
ϝ΋Ύγϟ΍ΏϧΎΟϟ΍ϩΎΟΗϻ΍ϲ΋ΎϧΛϡΎϣλ
 ΢Ηϓ ϱίΎϐϟ΍ΏϧΎΟϟ΍ϩΎΟΗϻ΍ϲΛϼΛϡΎϣλ

ΩϳέΑΗϟ΍ΓΩΎϣΔϧΣηϕλϠϣ Ȏ R410A˰ϟ αΎϳϗΏόηϣ


αϛΎόϣϟ΍έΎϳΗϠϟΓΩΎοϣΔϠλϔϣ
ϭΗϭϳϛϝϭϛϭΗϭέΑΎϬϠϣηϳΓέϭϠϔϣΔϳ΋ϓΩΕ΍ίΎϏϰϠϋϱϭΗΣϳ 3ΓϭρΧϟ΍
A
ϕϼϏ· 
R410A 1= kg
B
R410A˰ϟ ΔϳϏ΍έϓΔΧοϣ
R410A˰ϟ ΏϭΑϧ΃
2 2= kg
C
1 ϥϳϫΎΟΗ΍ϭΫϡΎϣλ 6ΓϭρΧϟ΍ ϥϳϫΎΟΗ΍ϭΫϡΎϣλ 4ΓϭρΧϟ΍
ΕΎϫΎΟΗ΍ΔΛϼΛϭΫϡΎϣλ
1+2= kg ΕΎϫΎΟΗ΍ΔΛϼΛϭΫϡΎϣλ
D O
90ΡϭΗϔϣ
F E

ΎϬϠϣηϳΓέϭϠϔϣΔϳ΋ϓΩΕ΍ίΎϏϰϠϋΞΗϧϣϟ΍΍ΫϫϱϭΗΣϳ
ϭΗϭϳϛϝϭϛϭΗϭέΑ
ϭΟϟ΍ϲϓΎϬϔϳέλΗΑϡϘΗϻ 7ΓϭρΧϟ΍
ϥϳϫΎΟΗ΍ϭΫϡΎϣλ
ΩϳέΑΗϟ΍ΓΩΎϣωϭϧ ϥϳϫΎΟΗ΍ϭΫϡΎϣλ
R410A ΕΎϫΎΟΗ΍ΔΛϼΛϭΫϡΎϣλ
 GWPΔϣϳϗ ΕΎϫΎΟΗ΍ΔΛϼΛϭΫϡΎϣλ
1975 
ϲϣϟΎόϟ΍έ΍έΗΣϻ΍ΔϳϧΎϛϣ· GWP
ϡΎϣλϟ΍Ώϳοϗ˯ΎρϏ
ˬϰΣϣ˵ϳϻέΑΣΑΔ΋ΑόΗϟ΍ϰΟέϳ
ϊϧλϣϟ΍ϲϓΩϳέΑΗϟ΍ΓΩΎϣΑΞΗϧϣϟ΍ϥΣη1‡ ϡΎϣλϟ΍Ώϳοϗ˯ΎρϏ
ϝϘΣϟ΍ϲϓΩϳέΑΗϟ΍ΓΩΎϣϥϣΔϳϓΎοϹ΍Δϳϣϛϟ΍2‡ ΔϧΎϳλϟ΍Ϋϔϧϣ˯ΎρϏ
ΩϳέΑΗϟ΍ΓΩΎϣΔϧΣηϲϟΎϣΟ·1+2‡
ΞΗϧϣϟ΍ϊϣΔϘϓέϣϟ΍ΩϳέΑΗϟ΍ΓΩΎϣΔϧΣηϕλϠϣϲϓ
ΞΗϧϣϟ΍ϥϣΏέϘϟΎΑ΄Αόϣϟ΍ϕλϠϣϟ΍ϕλϟΏΟϳ
 ϑϗϭΗϟ΍Δϣϳϗ˯ΎρϏϝΧ΍Ωϰϟ·ϝΎΛϣ ϥΣηϟ΍Ϋϔϧϣ ϪϳΑϧΗ
ΎϬϠϣηϳΓέϭϠϔϣΔϳ΋ϓΩΕ΍ίΎϏϰϠϋϱϭΗΣϳA ΎϬϠϣϛ΄ΑΩϳέΑΗϟ΍ΓΩΎϣϑϳέλΗΏΟϳˬ˯΍ϭϬϟ΍ϑϳϛϣΩϳέΑΗΓΩΎϣϟΏϳέγΗΙΩΣ΍Ϋ·I Ș
ϭΗϭϳϛϝϭϛϭΗϭέΑ ΔϳϣγΗϟ΍ΡϭϟϰϠϋΔΣοϭϣϟ΍Δϳϣϛϟ΍ΏγΣ˯΍ϭϬϟ΍ϑϳϛϣϲϓΔϠ΋Ύγϟ΍ΩϳέΑΗϟ΍ΓΩΎϣϥΣη΍ϡΛˬ˱ϻϭ΃ώϳέϔΗϟΎΑϡϗ
ϊϧλϣϟ΍ϲϓΩϳέΑΗϟ΍ΓΩΎϣΑΞΗϧϣϟ΍ϥΣηB
ΓΩΣϭϟ΍ϡγ΍ΔΣϭϟέυϧ΍ ΩέΑϣϟ΍έϳϭΩΗϟ΍ϡΎυϧϰϟ·ϝϭΧΩϟΎΑ˯΍ϭϬϟ΍ϭ΃ˬ R410A έϭϛΫϣϟ΍ϻ·ˬέΧ΁ΩϳέΑΗρϳγϭϝϭΧΩΑ΢ϣγΗϻ˱˯ΎΟέ Ș
ϝϘΣϟ΍ϲϓΩϳέΑΗϟ΍ΓΩΎϣϥϣΔϳϓΎοϹ΍Δϳϣϛϟ΍C  R410A ΔϳλΧηΕΎΑΎλ·ϰϟ·ϱΩ΅ϳϭωΩλΗϳϪϠόΟϳίΎϬΟϟ΍ϲϓϲόϳΑρέϳϏϲϟΎϋρϐοϙΎϧϫϥϭϛϳγϻ·ϭ
ΩϳέΑΗϟ΍ΓΩΎϣΔϧΣηϲϟΎϣΟ·D
ΔϳΟέΎΧϟ΍ΓΩΣϭϟ΍E
ϥΣηϠϟΏόηϣϟ΍ϭΩϳέΑΗϟ΍ΓΩΎϣΔϧ΍ϭργ΃F ΔϗΎρϟ΍έΩλϣΕϳΑΛΗ 1
ϲΑϳέΟΗϟ΍έΎΑΗΧϻ΍ϭΏϳϛέΗϟ΍ϥϣϕϘΣΗ Ȏ 
˯΍ϭϬϟ΍ϑϳϛϣϟΎ˱ϳέλΣΔϗΎρϟ΍έΩλϣϡ΍ΩΧΗγ΍ΏΟϳ Ș
ϲοέ΃ΏϳέγΗϊρΎϗΏϳϛέΗϰΟέϳˬΏρέϥΎϛϣϲϓ˯΍ϭϫϑϳϛϣΏϳϛέΗΔϟΎΣϲϓ I0AϰϠϋ Ș
ΕΎϣϳϠόΗϟ΍ϝϳϟΩϝϼΧϥϣϝϳϐηΗϟ΍ΔϳϔϳϛΎϧ΋ϼϣόϟΡέη΍˱˯ΎΟέ Ȏ ϥΎϛϣϹ΍έΩϗΓέ΋΍ΩϊρΎϗϡΩΧΗγ΍ˬϯέΧ΃ϥϛΎϣ΃ϲϓΏϳϛέΗϠϟ Ș

ϲΑϳέΟΗϟ΍ϝϳϐηΗϟ΍έλΎϧϋϥϣϕϘΣΗ ΎϬΟϳϠϔΗϭΏϳΑΎϧϷ΍ϊρϗ 2
ΕΎόΑέϣϟ΍ϲϓ ϕϘΣΗΔϣϼϋϊο ΔϧηΧϟ΍ϑ΍ϭΣϟ΍Δϟ΍ί·ΏΟϳϭΏϳΑΎϧ΃ϊρΎϘΑΏϳΑΎϧϷ΍ϊρϗϡΗϳ Ș
ΞϳϠϔΗϟ΍ϝϣϋϡΗϳˬΞϳϠϔΗϟ΍ΔϟϭϣΎλϝΎΧΩ·ΩόΑ Ș
ˮΏϭΑϧϷ΍ΔϠλϭϥϣΏέγΗϳίΎϐϟ΍
ˮΏϭΑϧϷ΍ΔϠλϭϟΓέ΍έΣϟ΍ϝίϋ ΔϳΩϳϠϘΗΞϳϠϔΗΓ΍Ω΃ ˰ϟΞϳϠϔΗϟ΍Γ΍Ω΃5$
ˮΔϳϓέρϟ΍ΔϠΗϛϟ΍ϲϓΕΎΑΛΑΔϳΟέΎΧϟ΍ϭΔϳϠΧ΍Ωϟ΍ϝϳλϭΗϟ΍ϙϼγ΃ϝΎΧΩ·ϡΗϝϫ
ˮ΍˱ΩϳΟΔΗΑΛϣΔϳΟέΎΧϟ΍ϭΔϳϠΧ΍Ωϟ΍ϝϳλϭΗϟ΍ϙϼγ΃ϝϫ ்ϳΑϣ·ωϭϧ ΡΎϧΟΔϟϭϣΎλωϭϧ ΏϠλωϭϧ νΑΎϘϟ΍ωϭϧ νΑΎϘϟ΍ωϭϧ
ˮϥΎϣ΄ΑϑϳέλΗϟ΍˯΍έΟ·ϡΗϝϫ ϡϣ2.0~1.5 ϡϣ1.5~1.0 ϡϣ0.5~0 A
ˮϥΎϣ΄ΑϝλΗϣνϳέ΄Ηϟ΍ρΧϝϫ
ˮϥΎϣ΄ΑΔΗΑΛϣΔϳϠΧ΍Ωϟ΍ΓΩΣϭϟ΍ϝϫ ΔϧηΧϟ΍ϑ΍ϭΣϟ΍ϝί΃2 ΏϭΑϧϷ΍ϊρϗ΍1 ΞϳϠϔΗϟ΍Ε΍ϭΩ΃ΓΩϋΎϗ
ˮΔΣ΋ϼϟΎΑΔϣίΗϠϣΔϗΎρϟ΍έΩλϣΔϳρϟϭϓϝϫ A
ˮ˯Ύοϭοϱ΃ϙΎϧϫϝϫ
ˮϲόϳΑρϝϛηΑ˯ϲοϳΡΎΑλϣϟ΍ϝϫ
ϲόϳΑρϝϛηΑϡΗϳ Γέ΍έΣϟ΍ΔΧοϣϲϓ ϥϳΧγΗϟ΍ϭΩϳέΑΗϟ΍ϝϫ
ˮϲόϳΑρϝϛηΑΔϓέϐϟ΍Γέ΍έΣΔΟέΩϡυϧϣϝϣόϳϝϫ
ΞϳϠϔΗΏϭΑϧ΃4 ΞϳϠϔΗϟ΍ΔϟϭϣΎλϝΧΩ΃3

΢ϳΣλέϳϏ ΢ϳΣλ

΍ ˱έϳΛϛΝέΎΧϠϟ ϲ΋ίΟ ωΩλΗ ΞϳϠϔΗϟ΍ϑϠΗ ϝ΋Ύϣ

4
1
Power cable:
3G1.5mm2
G
2
3G1.5mm2

Indoor unit
.R410A Outdoor unit
12K/18 Cooling&Heating

18 6.35
Power cable:

3 4
42 9.52
55 12.7 3G1.5mm2
60 15.88

COMP N1
1(L) 2(N)
3G1.5mm2
7 5
20
Indoor unit Outdoor unit
12K/18K Cooling

5
Power cable:

4
≥3G2.5mm
3
4G1.0mm 2G0.75mm
2 or
2
3G0.75mm 3G1.0mm2
15 A
1

5 A
7~5
25=Bmax
Indoor unit
7 B
6.35
20 24/30KCooling&Heating Outdoor unit
6.35
50 BR

L
BL
POWER

N
SUPPLY Y/G

3
5

Power cable:
4

≥3G2.5mm
3

4G1.0mm2
or
2
2

4G1.5mm
4
1

Indoor unit

24/30KCooling Outdoor unit


5
.1 BR
L

BL
POWER
N

SUPPLY Y/G

.2
1

15 .3 1
76 0.1 .H07RN-F H05RN-F
.T. 3.15A/250V 2
2-1 3
3 4
5
90 .4 3
6

3
‫‪3‬‬

‫‪256‬‬

‫‪364‬‬
‫‪140‬‬ ‫‪500‬‬ ‫‪140‬‬ ‫‪130‬‬ ‫‪628‬‬ ‫‪130‬‬

‫‪12K‬‬ ‫‪18/24K‬‬

‫‪1‬‬

‫‪400‬‬
‫‪2‬‬
‫‪129‬‬ ‫‪660‬‬ ‫‪129‬‬

‫‪3‬‬

‫‪30K‬‬

‫‪12‬ﻛﯾﻠو ‪18،‬ﻛﯾﻠو ‪ 24 ،‬ﻛﯾﻠو ‪----‬ﻣﻌﺑرا ﻋﻧﮭﺎ ﻓﻲ دﻟﯾل ﺗﺷﯾر إﻟﻰ ﻗدرة اﻟﺟﮭﺎز‬

‫‪30K‬‬ ‫‪24K‬‬ ‫‪18K‬‬ ‫‪12K‬‬

‫‪9.52‬‬ ‫‪6.35‬‬ ‫‪6.35‬‬ ‫) ‪6.35‬‬

‫‪15.88‬‬ ‫‪15.88‬‬ ‫‪12.7‬‬ ‫) ‪9.52‬‬

‫‪0.8‬‬

‫‪1‬‬

‫‪1‬‬

‫‪2‬‬

‫‪3‬‬

‫=‪B‬‬

‫‪A=140‬‬
‫‪30K‬‬

‫‪30mm‬‬
‫‪mm‬‬
‫‪1‬‬

‫=‪B‬‬

‫‪2‬‬ ‫‪24K‬‬ ‫‪A=113‬‬ ‫‪30mm‬‬


‫‪mm‬‬

‫‪3‬‬
‫=‪B‬‬

‫‪4‬‬
‫‪A=113‬‬
‫‪18K‬‬ ‫‪mm‬‬
‫‪30mm‬‬

‫=‪B‬‬

‫‪A=145‬‬
‫‪30mm‬‬

‫‪12K‬‬ ‫‪mm‬‬

‫‪2‬‬

‫‪60‬‬

‫‪2‬‬
Δϓέϐϟ΍˯΍ϭϫϑϳϛϣΏϳϛέΗϝϳϟΩ
ϡ΍ΩΧΗγϻ΍ϝΑϗίϳϬΟΗϟ΍

ΕϳΑΛΗϟ΍ϥΎϛϣέΎϳΗΧ΍ ΏϳϛέΗϠϟΔϣίϼϟ΍Ε΍ϭΩϷ΍
ϡΎόϟ΍έϭϬϣΟϠϟΡΎΗϣίΎϬΟϟ΍
ϥ΍έϭΩΡΎΗϔϣ Ș ϙϔϣ Ș
ΔϳϠΧ΍Ωϟ΍ΓΩΣϭϟ΍ ϡϣ26ˬϡϣ22ˬϡϣ17) ι΍˷έϗ Ș
ϡ΋ϼϣϝϛηΑϡγΟϟ΍ϡϋΩϪϳϓϥϛϣϳί΍ίΗϫ΍ΏΑγϳϻΕΑΎΛϥΎϛϣϟ΍ Ș ΏϳΑΎϧ΃ϊρΎϗ Ș έΎηϧϣ Ș
ΓΩΣϭϟ΍Ν΍έΧ·ϭ΃ϝΎΧΩ·ϙΎΑέ·ϡΗϳϻΙϳΣˬΓέϭΎΟϣϟ΍ΔϘρϧϣϟ΍ϥϣΩϟϭΗϣϟ΍έΎΧΑϟ΍ϭ΃Γέ΍έΣϟΎΑέΛ΄ΗϣέϳϏˬϥΎϛϣϟ΍ Ș ΞϳϠϔΗΓ΍Ω΃ Ș έϔΣΏΎϘΛϣ Ș
ΔϳΟέΎΧϟ΍ΓΩΣϭϟΎΑΏϳΑΎϧϷ΍ϝϳλϭΗϥϛϣϳΙϳΣˬϑϳέλΗϟ΍ϝϬγϳϥΎϛϣϟ΍ Ș ϥϳϛγ Ș  ϡϣ26ϭ19ϭ17 ϲϏ΍έΑΡΎΗϔϣ Ș
ΎϬϠϣϛ΄ΑΔϓέϐϟ΍ϲϓΩέΎΑϟ΍˯΍ϭϬϟ΍ϊϳίϭΗϥϛϣϳΙϳΣˬϥΎϛϣϟ΍ Ș αΎϳϗρϳέη Ș ίΎϐϟ΍ΏϳέγΗϑΎηΗϛ΍Γ΍Ω΃ Ș
 ϡϭγέϟ΍ϰϟ·ϊΟέ΍ ϪϟϭΣΔϳϓΎϛΔΣΎγϣϊϣˬΔϗΎραΑϘϣϥϣΏέϘϟΎΑˬϥΎϛϣϟ΍ Ș ΏϭϘΛϊ˷γϭϣ Ș ˯ΎϣϭϥϭΑΎλϝϭϠΣϣϭ΃
ΕϧγϳέϭϠϔϟ΍΢ϳΑΎλϣϭΔϳϛϠγϼϟ΍ΓίϬΟϷ΍ϭϭϳΩ΍έϟ΍ϭϥϭϳίϔϠΗϟ΍ΓίϬΟ΃ϥϋ΍˱ΩϳόΑέΗϣ1ϥϣέΛϛ΃ΔϓΎγϣϙΎϧϫϥϭϛΗΙϳΣϥΎϛϣ Ș
΢ϳΑΎλϣΓ˯Ύο·ΩϧϋΕ΍έΎη·ϰϘϠΗΗϥ΃ϪϳϓΔϳϠΧ΍Ωϟ΍ΓΩΣϭϠϟϥϛϣϳϥΎϛϣϲϓϪόοˬέ΍ΩΟϟ΍ϰϠϋΩόΑϥϋϡϛΣΗϟ΍ίΎϬΟΏϳϛέΗϝΎΣϲϓ Ș
Δϓέϐϟ΍ϲϓΕϧγϳέϭϠϔϟ΍
ΔϗΎρϟ΍έΩλϣ

ΔϳΟέΎΧϟ΍ΓΩΣϭϟ΍ ϝρϋΩϭΟϭϥϭΩϲ΋ΎΑέϬϛϟ΍ΩϬΟϟ΍ϥϣΩϛ΄ΗˬαΑϘϣϟ΍ϲϓΔϗΎρϟ΍αΑΎϗϝΎΧΩ·ϝΑϗ Ș
Ș
΍˱ΩϳΟϪΗϳϭϬΗϡΗϳέηΎΑϣϟ΍αϣηϟ΍˯ϭοΑϭ΃έΎρϣϟΎΑ΍ ˱έΛ΄ΗϝϗϷ΍ˬϥΎϛϣϟ΍ ϕΑΎρϣϟ΍ϡγϻ΍ΡϭϟαϔϧϭϫΔϗΎρϟ΍έΩλϣ
Ș
˯Ύοϭοϟ΍ϭί΍ίΗϫϻ΍Ω΍ΩίϳϻΙϳΣˬΓΩΣϭϟ΍ϝϣΣΗϪϳϓϥϛϣϳˬϥΎϛϣϟ΍ ΔϗΎρϠϟΔϳέλΣΔϳϋέϓΓέ΋΍ΩΏϳϛέΗΑϡϗ Ș
ϥ΍έϳΟϠϟΝΎϋί·ϲϓ˯Ύοϭοϟ΍ϭΓέΩΎλϟ΍ΡΎϳέϟ΍ΏΑγΗΗϻΎϣΩϧϋˬϥΎϛϣϟ΍
Ș ϪόρϗϕϳέρϥϋϝΑΎϛϟ΍ΩΩϣΗϻΔϗΎρϟ΍ϝΑΎϛϝΎΧΩ·ϥϛϣϳΙϳΣΑΔϓΎγϣϰϠϋαΑϘϣϟ΍ϥϭϛϳϥ΃ΏΟϳ Ș
QΔϣϼόΑΔΣΎγϣϪϳϓΩΟϭΗϥΎϛϣϟ΍ Ș
ϩϼϋ΃ϝϛηϟΎΑ΢οϭϣϭϫΎϣϛ

ΔϳΟέΎΧϟ΍ϭΔϳϠΧ΍Ωϟ΍Ε΍ΩΣϭϟ΍ΏϳϛέΗϟΔϣγέ
R410AΔϳέϭϠϓϭέΩϳϬϟ΍ϥϭΑέϛϟ΍ΕΎΑϛέϣϥϣϲϟΎΧΩέΑϣΕϼϳΩϭϣϟΎΑΩΟϭϳ
ΔϘΣϠϣϟ΍ϊρϘϟ΍
ϡϭρέΧωΎϔΗέ΍ϰϟ·ϩΎΑΗϧϻ΍ΏΟϳ
ΩΩϋ ϑϳέλΗϟ΍
Ω΍ϭϣϟ΍ ΔϘΣϠϣϟ΍ϊρϘϟ΍ ϡϗέϟ΍ ϡγ15ϥϣέΛϛ΃

1 ΩόΑϥϋϡϛΣΗϟ΍ίΎϬΟ 1

2
2 ΔϓΎΟϟ΍ΔϳέΎρΑϟ΍R-03

1 3 ϡγ10ϥϣέΛϛ΃ ί

ΕϳΑΛΗϟ΍ΔΣϭϟ

1 4
ϑϳέλΗϟ΍ϡϭρέΧ

4X50
6 Εϧϣγ΃ˬϱΫϻϭϓέΎϣγϣ
5 ΏϳΑΎϧϷ΍ΕΎϫΎΟΗ΍ΏϳΗέΗ
ϡγ10ϥϣέΛϛ΃
4 ϲϛϳΗγϼΑ˯ΎρϏ 4X25 6
ϲϏέΑέΎϣγϣ ϯέγϳϟ΍ΔϳϔϠΧϟ΍ΔϬΟϟ΍ ϭ

έΎγϳ ϲϔϠΧϟ΍ΔϬΟϟ΍ ΃
1 7
ϑϳέλΗϕϓέϣ ϰϧϣϳϟ΍

1 ϰϠϋιέΣ΍
ϡΎόρϟ΍ΔϳρϐΗ 8 ϥϳϣϳ
Ν
ϝϔγ΃
4 ΔϧΎρΑ 9

1 10 ϡγ10ϥϣέΛϛ΃
ΏϭΑϧϸϟϡϋ΍Ωϟ΍ΡϭϠϟ΍
ϡγ30ϥϣέΛϛ΃
1 ϝϳλϭΗϟ΍ϝΑΎϛ 11
ί ΃
ϝϛηϟ΍ϲϓϰϟ·ϥϣΕΎϣϼόϟ΍ Ș
ΎϬΑΩΟϭϳϻρϘϓΩϳέΑΗΎϬΑϲΗϟ΍Ε΍ΩΣϭϟ΍ΔυΣϼϣ ϊρϘϟ΍ϡΎϗέ΃ϲϫ
ϑϳέλΗϕϓέϣ ΔϳοέϷ΍ϭΔϳϠΧ΍Ωϟ΍ΓΩΣϭϟ΍ϥϳΑΔϓΎγϣϟ΍ Ș
έΗϣ2ϥϣέΛϛ΃ϥϭϛΗϥ΃ΏΟϳ
Ω

ΏϳΑΎϧϸϟΔϳέΎϳΗΧϻ΍˯΍ίΟϷ΍ ˰ϫ

ϕλϻέϳϏρϳέη ΃ ϡγ200ϥϣέΛϛ΃
ϕλϻρϳέη Ώ
έϳϣΎγϣΑ L.S ΓΩϋΎϗ Ν
ΝέΎΧϟ΍ϭϝΧ΍ΩϠϟϲ΋ΎΑέϬϛϝϳλϭΗϝΑΎϛ Ω ϡγ50ϥϣέΛϛ΃
ϑϳέλΗϡϭρέΧ ˰ϫ
΢ϳοϭΗϠϟρϘϓϲϫϩϼϋ΃ΓΩϭΟϭϣϟ΍ΓέϭλϟΎϓˬϱέΗηΗϱΫϟ΍ϲϠόϔϟ΍ΞΗϧϣϟΎΑϡ΍ίΗϟϻ΍ϰΟέϳ
Γέ΍έΣϠϟΔϟίΎϋΓΩΎϣ ϭ
ΏϳΑΎϧ΃ΔΣΗϓ˯ΎρϏ ί
ΏϳϛέΗϟ΍ϝΑϗϝϳϟΩϟ΍΍Ϋϫ΃έϗ΍
ϝϳϟΩϟ΍΍ΫϬϟΎϘ˱ ϓϭϡΩΧΗγϣϠϟϝϳϐηΗϟ΍ϝ΋ΎγϭϑΎϛϝϛηΑϙέη΃
˶
0011503597
Installation Manual Form: AJFEH3CHAO-4-191203

R-410A 60Hz 230V

YJFE18YH3CHAO-4
YJGE18YH3CHAO-4
YJFE24YH3CHAO-4
YJGE24YH3CHAO-4
YJFE28YH3CHAO-4
YJGE28YH3CHAO-4

Issue Date
Dec, 2019
ICEBERG HIGH WALL FIXED 60HZ R-410A HEAT PUMP
YHGE 12 to 36 ZT3CFEOR4
ICEBERG HIGH WALL FIXED 60HZ R-410A HEAT PUMP

Indoor Unit
• Auto Random Restart • Golden fin
• Low noise • Long distance wind blast
• Washable air filter • 3D air flow
• Sleep Mode • I feel
• Easy maintenance • Cold Plasma Technology 12-24 K
• Self-diagnosis and Auto-protection • WIFI Ready

Remote Control
• 5 operation modes: Auto, Cool, Dry, Heat, Fan only
• Multi-speed fan setting: High/Medium/Low/Auto
• 24-hour timer setting
• Turbo cool setting
• Background light LCD display 30 K
• Real-time clock display

Condensing Unit
• Compact size
• More sturdy and durable
• High efficiency compressor
• Low noise
• 3-minute protection
• Valve protection 36 K
• Easier installation
• Easier maintenance
• Golden fin

The YORK ® line of High Wall Air Conditioners includes a wide range of sizes
to give you more flexibility in your product offering. Each model is designed to
provide comfort and efficiency, in an easy-to-operate unit and the sleek design
fits a variety of spaces, whether it’s in a home or office. Models meet the highest
energy efficiency ratings, so less energy is consumed without sacrificing comfort
and performance. Both the condensing and indoor units are engineered for quiet
operation. And comfort control settings are easily changed with the touch of a
button on the remote control.

2
24 Hour Timer 3 Minutes Protection
Allows programmed start times up to A 3-minute delay before the
24 hours in advance for flexible and compressor will restart helps
more convenient operation. avoid compressor damage and
24
extend compressor life.

ICEBERG HIGH WALL FIXED 60HZ R-410A HEAT PUMP


Electrical Defrosting
Child Lock Automatic deicing of outdoor unit
If the lock button on the remote below certain temperatures helps
control is pressed, it must be ensure proper operation, saves
pressed again before use, which energy and improves efficiency.
helps prevent accidental operation.
Features and benefits (Heat pump only)

Multi-Speed Fan Cold Plasma Technology


Low Ambient Heating at -20°C
Multi-speed fan helps satisfy various airflow Make your room full of an abundance of
Weekly Timer
Optional weekly timer allows for cold
The AC will run in heating mode
when outdoor temperature is belo
requirements. plasma ions. Enjoy the feeling of a forest
customized programming of on/off
times each day of the week for
at special user-reques
20°C to meet
applications. (Heat pump only)
home.
more flexible and convenient
operation.
-20 C o

3-Minute Protection
3 Minutes Protection Auto Restart Low Ambient Cooling at -15°C
Auto restart The AC will run in cooling mode
p to
nd
A 3-minute delay before the compressor will
A 3-minute delay before the
AUTO Unit is automatically returned to previous
Unit is automatically returned to when outdoor temperature is
compressor will restart helps previous operating conditions after below -15°C to meet special
restart helps avoid compressor damage and
avoid compressor damage and
operating conditions after a power outage,
a power outage, for simplified for applications.
user-requested
extend compressor life.
-15 C
work time.
o
operation. (Cooling only. Standard for
simplified operation. Unitary Smart DC inverter types.
Optional for others.)

24-Hour Timer
Electrical Defrosting
24 Hour Timer
Automatic deicing of outdoor unit 3 Minutes Protection
Self Diagnosis
Allows programmed start times up to
24 Allows programmed start times up to 24Acompressor
below certain
hoursproper
ensure
temperatures
in advance
helps
for flexible
operation, saves and
hours
3-minute delay before the
will restart helps
Clearly displayed failure codes allow for quicker
n. 24
more
in convenient
advance
(Heat pump only)
operation.
for flexible and
energy and improves efficiency. more convenient
avoid compressor damage and
extend compressor life.
troubleshooting and easier maintenance.
operation.

I Feel
Low Ambient Heating at -20°C
The AC
Child will run in heating mode
Lock
Electrical Defrosting R-410A
Automatic deicing of outdoor unit
ff A temperature sensor embedded in the remote
Ifwhen outdoor
the lock
20°C toismeet
temperature
button is below
on the remote
special user-requested
below certain temperatures helps Environment-friendly refrigerant cools and heats
control pressed, it must be ensure proper operation, saves
-20oC control helps ensure accurate air temperature
applications.
pressed again(Heat pump
before use,only)
which energy and improves efficiency. more efficiently without destroying the ozone
helps prevent accidental operation.
around the user and not just around the (Heat pump only)
indoor layer.
unit, providing maximum comfort.
Low Ambient Cooling at -15°C
The AC will run in cooling mode Low Ambient Heating at -20°C
Weekly Timer temperature is
when outdoor
Optional weekly timerspecial
allows for The AC will run in heating mode
er below -15°C to meet when outdoor temperature is below
customized programming
user-requested of on/off
applications.
times 20°C to meet special user-requested
-15oC (Cooling only. Standard for for
each day of the week
applications. (Heat pump only)
more flexible
Unitary SmartandDC convenient
inverter types. -20oC
operation.
Optional for others.)

Low Ambient Cooling at -15°C


Auto restart The AC will run in cooling mode
Unit is automatically returned to when outdoor temperature is
AUTO
previous operating conditions after
a power outage, for simplified
Golden fin
below -15°C to meet special
user-requested applications.
operation. -15oC (Cooling only. Standard for
The unique anticorrosive golden coating on the heat exchangers
Unitary Smart DC inverter types.
Optional for others.)

can withstand the salty air, rain and other corrosive elements.

3
Specification

YORK Set Model YHGE12ZT3CFEOR4 YHGE18ZT3CFEOR4 YHGE24ZT3CFEOR4 YHGE30ZT3CFEOR4 YHGE36ZT3CFEOR4


YORK Outdoor Model YHGE12YT3CFEO-4 YHGE18YT3CFEO-4 YHGE24YT3CFEO-4 YHGE30YT3CFEO-4 YHGE36YT3CFEO-4
YORK Indoor Model YHGE12XT3CFE-R4 YHGE18XT3CFE-R4 YHGE24XT3CFE-R4 YHGE30XT3CFE-R4 YHGE36XT3CFE-R4
Power supply Ph-V-Hz 1-220~230-60
Power supply by Indoor Indoor Indoor Outdoor Outdoor
Capacity Btu/h 11,500 18,000 22,000 27,200 31,800
Power Input W 930 1,450 1,775 2,210 2,585
Cooling @ T1
Rated Current A 4.2 6.5 8.0 9.7 11.7
EER Btu/h·W 12.35 12.40 12.40 12.30 12.30
Capacity Btu/h 9,900 15,300 19,000 23,000 27,600
Power Input W 1,135 1,760 2,200 2,645 3,170
Cooling @ T3
Rated current A 5.1 7.9 9.9 11.5 14.3
EER Btu/h·W 8.70 8.70 8.65 8.70 8.70
Capacity Btu/h 11,260 17,401 22,178 26,614 29,684
Capacity W 3,300 5,100 6,500 7,800 8,700
Power Input W 970 1,445 1,855 2,110 2,350
Heating
Rated Current A 4.3 6.4 8.3 9.5 10.3
COP Btu/h·W 11.60 12.11 11.94 12.62 12.62
COP W/W 3.40 3.55 3.50 3.70 3.70
Max. input consumption W 1,500 2,300 2,900 3,600 3,700
Max. current A 8 11.9 15.5 18.7 19
Starting current A 27 35 46 52 60
Moisture Removal l/h 1.2 1.8 2.2 2.8 3.0
Type Rotary Rotary Rotary Rotary Rotary
Rated current(RLA) A 4.75 6.55 8.80 10.20 11.60
Compressor Capacitor μF 35 40 45 55 70
ESTER OIL VG74 / HAF6801or α68HES-H or α68HES-H or α68HES-H or
Refrigerant oil/oil charge ml
350 equivalent /480 equivalent / 570 equivalent /570 equivalent /880
Power Output W 14 58 35 70 120
Indoor fan motor Capacitor μF 1.5 3 NA (DC Motor) NA (DC Motor) NA (DC Motor)
Speed(Hi/Mi/Lo) rpm 1,100/950/800 1,160/1,000/850 1,160/1,000/850 1130/1030/900 1,150/1,000/850
Indoor air flow (Hi/Mi/Lo) m3/h 660/570/480 1,200/1,100/900 1,200/1,100/900 1,500/1,250/1,050 2,200/1,900/1,500
Indoor noise level (Hi/Mi/Lo) dB(A) 39/37/34 45/43/39 46/43/39 51/45/42 53/48/43
Dimension(WxHxD) mm 850×270×202 1,131×315×230 1,131×315×230 1,280×367×266 1,369×379×283
Indoor unit Packing (WxHxD) mm 900x335x260 1,220×400×310 1,220×400×310 1,385×435×325 1,495×480×410
Net/Gross weight kg 8.5/11.0 14.5/17.0 14.5/17.0 18.5/22.0 23.5/28.0
Power Output W 32 61 70 100 102
Outdoor fan motor Capacitor μF 3 4 NA (DC Motor) NA (DC Motor) NA (DC Motor)
Speed rpm 860 840 780 900 900
Outdoor air flow m3/h 2,100 2,500 3,200 3,400 3,800
Outdoor noise level dB(A) 53 55 57 60 60
Dimension(WxHxD) mm 810x585x280 860×650×310 885×795×366 885×795×366 900x750x340
Outdoor unit Packing (WxHxD) mm 940x630X385 995×730×445 1,050×910×500 1,050×910×500 1,060x820x450
Net/Gross weight kg 34.0/37.0 45.0/49.0 54.0/59.0 58.0/64.0 60.0/65.0
Refrigerant type/Charge g R-410A/1,150 R-410A/1,510 R-410A/1,810 R-410A/2,400 R-410A/2,350
Standard connection pipe length m/ft 5/16.4 5/16.4 5/16.4 5/16.4 5/16.4
Additional charge g 20 x (LengthM-5) 20 x (LengthM-5) 30 x (LengthM-5) 40 x (LengthM-5) 40 x (LengthM-5)
Liquid side/ Gas side mm 6.35/12.7 6.35/12.7 9.53/15.88 9.53/15.88 9.53/15.88
Refrigerant piping Max. refrigerant pipe length m 15 15 15 15 15
Max. difference in level m 5 5 5 5 5
Indoor setting temperature (cooling/ heating) °C 16-30 16-30 16-30 16-30 16-30
Ambient Operation temperature (cooling/ heating) °C 21~55/-7~24 21~55/-7~24 21~55/-7~24 21~55/-7~24 21~55/-7~24
Qty’per 20’ /40’ /40'HQ Set 96/198/228 60/128/144 44/92/114 42/88/106 40/80/98
Nominal testing conditions @ T1:
Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 95°F DB / 75.2°F WB (35°C DB / 24°C WB)
Heating - Indoor 68°F DB / 59°F WB (20°C DB / 15°C WB) & Outdoor 44.6°F DB / 42.8°F WB (7°C DB / 6°C WB)
Nominal testing conditions @ T3:
Cooling - Indoor 84.2°F DB / 66.2°F WB (29°C DB / 19°C WB) & Outdoor 114.8°F DB / 75.2°F WB (46°C DB / 24°C WB)

Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other
trademarks used herein may be trademarks or registered trademarks of other companies.
FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM
© 2020 Johnson Controls, Inc, P.O. Box 423, Milwaukee, WI 53201, All rights reserved worldwide. PUBL-1576(1220)
High Wall Unit
User Manual New Released Form: UHF(G)ET3CFEOR4-201202

Iceberg High Wall


R-410A 60Hz

ICEBERG

12K-24K

ICEBERG

30K

ICEBERG

36K

Dec.2nd, 2020
19
20
20
19
UHF(G)ET3CFEOR4-201202

ICEBERG

12K-24K

ICEBERG

30K

ICEBERG

36K
DUCT MID STATIC PRESSURE 60HZ R410A
T3 WORKING CONDITION INVERTER (KSA)
YEKE(18-60)BZL(R)
DUCT MID STATIC PRESSURE 60HZ R410A T3 WORKING CONDITION INVERTER (KSA)

Indoor Unit
• DC fan motor
• High Air flow
• Adjusted pressure by wired controller
• Wireless controller(optional)
• Blue fin

Wired Controller Optional


• Compact design
• Use as remote signal receiver
• Individual & group control (max. 16 indoor units)
• Timer/clock
• Easy installation

Condensing Unit
Standard
• Larger fan, slower speed to reduce noise
• DC inverter compressor and motor
• Built-in valve, 4-way pipe connection
• “888” digital test panel
• Blue fin

The YORK® line of MSP duct Air conditioners includes a wide range of sizes to
give you more flexibility in your product offering. Each model is designed to
provide comfort and efficiency, in an easy-to-operate unit and the sleek design
fits a variety of spaces, whether it’s in a home or office. Models meet the highest
energy efficiency ratings, so less energy is consumed without sacrificing comfort
and performance. Both the condensing and indoor units are engineered for quiet
operation. And comfort control settings are easily changed with the touch of a
button on the remote control.

2
24 Hour Timer 3 Minutes Protection
Allows programmed start times up to A 3-minute delay before the
24 hours in advance for flexible and compressor will restart helps
more convenient operation. avoid compressor damage and
24
extend compressor life.

Electrical Defrosting
Child Lock Automatic deicing of outdoor unit
If the lock button on the remote below certain temperatures helps
Features and benefits control is pressed, it must be
pressed again before use, which
ensure proper operation, saves
energy and improves efficiency.
helps prevent accidental operation. (Heat pump only)

Multi-Speed Fan Washable Filter


Multi-speed fan helps satisfy various airflow Washable filter allows for convenient service and
Low Ambient Heating at -20°C
requirements. maintenance.
Weekly Timer
Optional weekly timer allows for The AC will run in heating mode
customized programming of on/off when outdoor temperature is below
times each day of the week for 20°C to meet special user-requested
more flexible and convenient -20oC applications. (Heat pump only)
operation.

3-Minute Protection
3 Minutes Protection
Auto Restart Low Ambient Cooling at -15°C
Auto restart The AC will run in cooling mode
p to
nd A 3-minute delay before the compressor will
A 3-minute delay before the
compressor will restart helps AUTO
Unit is automatically returned to previous
Unit is automatically returned to when outdoor temperature is
previous operating conditions after below -15°C to meet special
restart helps avoid compressor damage and
avoid compressor damage and
extend compressor life.
operating conditions after a power outage,
a power outage, for simplified for applications.
user-requested
operation. -15 C o
(Cooling only. Standard for
work time. simplified operation. Unitary Smart DC inverter types.
Optional for others.)

Electrical Defrosting
Automatic deicing of outdoor unit

24-Hour Timer
below certain temperatures helps
24 Hourproper
ensure Timeroperation, saves 3 Minutes Protection
Self Diagnosis
Allows programmed
and improves start times up to
n. Allows programmed start times up to 24
energy
24 hours
(Heat pumpin advance
only)
efficiency.
for flexible and hours
A 3-minute delay before the
compressor will restart helps
Clearly displayed failure codes allow for quicker
more convenient operation.
24 in advance for flexible and more convenient
avoid compressor damage and
extend compressor life.
troubleshooting and easier maintenance.
operation.
Low Ambient Heating at -20°C
The AC will run in heating mode
ff when outdoor temperature is below
20°C Electrical Defrosting
Childto meet special user-requested
Lock Automatic deicing of outdoor unit
-20oC applications. (Heaton
If the lock button pump only)
the remote below certain temperatures helps
control is pressed, it must be ensure proper operation, saves
pressed again before use, which energy and improves efficiency.
helps prevent accidental operation. (Heat pump only)

Low Ambient Cooling at -15°C


The AC will run in cooling mode
when outdoor temperature is
er below -15°C to meet special
Weekly Timer applications.
user-requested Low Ambient Heating at -20°C
-15oC Optional only.
(Cooling weekly timer allows
Standard for for The AC will run in heating mode
Unitary Smart
customized DC inverter of
programming types.
on/off when outdoor temperature is below
Optional forday
times each others.)
of the week for 20°C to meet special user-requested
more flexible and convenient -20oC applications. (Heat pump only)
operation.

Low Ambient Cooling at -15°C


Auto restart The AC will run in cooling mode
Unit is automatically returned to when outdoor temperature is
AUTO
previous operating conditions after
a power outage, for simplified Inner Groove Copper Tube
below -15°C to meet special
user-requested applications.
operation. -15oC (Cooling only. Standard for
Unitary Smart DC inverter types.
Inner groove copper tubing allows more refrigerant to pass
Optional for others.)

through, improving heat exchange by 30 to 50% when compared


to traditional copper tubing, and lowering power consumption
while keeping output capacity at the same level.

3
Specification
York Set Model YEKE18BZL3CJOW3 YEKE24BZL3CJOW3 YEKE36BZL3CJOW3
York Outdoor Model YEKE18BYL3CJO-3 YEKE24BYL3CJO-3 YEKE36BYL3CJO-3
York Indoor Model YEKE18BXL3CJ-W3 YEKE24BXL3CJ-W3 YEKE36BXL3CJ-W3
Power supply Ph/V/Hz 1/220~240/60 1/220~240/60 1/220~240/60
Power supply at rated capacity Ph/V/Hz 1/230/60 1/230/60 1/230/60
Capacity Btu/h 18,000(6,000~22,320) 21,800(8,300~27,000) 33,000(10,000~40,000)
Capacity kW 5.28(1.76~6.45) 6.39(2.43~7.91) 9.70(2.93~11.7)
Input kW 1.45 1.76 2.66
Rated Cooling(T1)
Running current A 8.08 10.03 11.90
EER W/W 3.64 3.63 3.64
EER Btu/hW 12.40 12.40 12.40
Capacity Btu/h 16,400(5,000~18,000) 19,600(6,500~23,000) 31,000(8,000~33,000)
Capacity kW 4.80(1.46~5.27) 5.73(1.90~6.74) 9.10(2.34~9.6)
Input kW 1.89 2.25 3.56
Rated Cooling(T3)
Running current A 10.35 12.33 14.39
EER W/W 2.54 2.55 2.55
EER Btu/hW 8.70 8.70 8.70
Capacity Btu/h 18,260(6,000~22,500) 24,600(7,985~27,507) 35,636(10,000~40,270)
Capacity kW 5.35(1.76~6.59) 7.20(2.34~8.06) 10.45(2.93~11.8)
Input kW 1.50 2.02 2.94
Rated Heating(T1)
Running current A 8.14 10.02 13.01
COP W/W 3.55 3.55 3.55
COP Btu/hW 12.12 12.12 12.12
Moisture Removal l/h 0.95 1.2 1.7
Max. input consumption W 2300 2700 5100
Max. current A 12 15 22.4
Operation Control Wired Wired Wired
Input W 160 200 200
Output W / / /
Indoor fan motor Running current A 0.75 0.87 0.87
Capacitor uF / / /
Speed rpm 850/750/650/600 860/760/660/600 900/840/780/750
Indoor air flow m3/h 1480/1280/1150/950 1500/1300/1180/950 2000/1740/1500/1280
External static pressure Pa 25 (0~100) 25 (0~100) 37(0~150)
Indoor noise level (Sound pressure level) dB(A) 42/40/39/36 45/42/40/36 48/45/42/39
Unit (WxDxH) mm 1100×700×248 1100×700×248 1500×700×248
Indoor dimension
Packing (WxDxH) mm 1340×870×330 1340×870×320 1710×870×330
Indoor weight Net/Gross kg 31/35 31/35 46/55
Type rotary rotary rotary
Capacity W/h 4410 4410 7000
Input W 1335 1335 2150
Compressor
Rated current(RLA) A 8.5 8.5 8.7
Thermal protector external external external
Refrigerant oil ml 350 350 520
Input W 128 128 190
Outdoor fan motor
Speed rpm 850 850 800±40
Outdoor air flow m3/h 3300 3300 5500
Outdoor noise level (Sound pressure level) dB(A) 60 60 65
Outdoor dimension Unit/Packing (WxDxH) mm 890×340×700/1046×460×780 920×372×760/1085×487×843 950×370×1350/1090×480×1500
Outdoor weight Net/Gross kg 46.5/51.5 54/60 103/110
Type R410A R410A R410A
Refrigerant
Charge g 1850 2000 3700
Liquid side/Gas side mm 9.52/15.88 9.52/15.88 9.52/19.05
Refrigerant pipe Max. refrigerant pipe length m 25 30 50
Max. difference in level m 15 15 30
Operation temperature range ℃ 16-30 16-30 16-30
Ambient temperature range ℃ 10~52 10~52 10~52
Qty’per 20’& 40’&40HQ Set 36/75/85 31/66/76 24/52/59

4
DUCT MID STATIC PRESSURE 60HZ R410A T3 WORKING CONDITION INVERTER

Specification
York Set Model YEKE42BZL3CJOW3 YEKE42BZR3CJOW3
York Outdoor Model YEKE42BYL3CJO-3 YEKE42BYR3CJO-3
York Indoor Model YEKE42BXL3CJ-W3 YEKE42BXL3CJ-W3
Power supply Ph/V/Hz 1/220~240/60 3/380~415/60
Power supply at rated capacity Ph/V/Hz 1/230/60 3/400/60
Capacity Btu/h 40,000(14,000~53,000) 40,000(14,000~53,000)
Capacity kW 11.70(4.1~15.5) 11.70(4.1~15.5)
Input kW 3.23 3.23
Rated Cooling(T1)
Running current A 15.10 5.50
EER W/W 3.63 3.63
EER Btu/hW 12.40 12.40
Capacity Btu/h 37,600(11,000~46,000) 37,600(11,000~46,000)
Capacity kW 11.0(3.22~13.5) 11.0(3.22~13.5)
Input kW 4.32 4.32
Rated Cooling(T3)
Running current A 18.50 7.91
EER W/W 2.55 2.55
EER Btu/hW 8.70 8.70
Capacity Btu/h 47950(13,650~64,843) 47950(13,650~64,843)
Capacity kW 14.05(4.0~19.0) 14.05(4.0~19.0)
Input kW 3.90 3.90
Rated Heating(T1)
Running current A 15.15 5.55
COP W/W 3.60 3.60
COP Btu/hW 12.30 12.30
Moisture Removal l/h 1.1 1
Max. input consumption W 7200 7200
Max. current A 32 10.5
Operation Control Wired Wired
Input W 300 300
Output W 197 197
Indoor fan motor Running current A 1.3 1.3
Capacitor uF / /
Speed rpm 1000/900/810/750 1000/900/810/750
Indoor air flow m3/h 3590/3200/2880/2280 3590/3200/2880/2280
External static pressure Pa 50(0~160) 50(0~160)
Indoor noise level (Sound pressure level) dB(A) 49/46/43/40 49/46/43/40
Unit (WxDxH) mm 1350×490×425 1350×490×425
Indoor dimension
Packing (WxDxH) mm 1565×724×510 1565×724×510
Indoor weight Net/Gross kg 61/72 61/72
Type rotary rotary
Capacity W/h 9800 13780
Input W 3000 4060
Compressor
Rated current(RLA) A 12.1 12.3
Thermal protector external external
Refrigerant oil ml 870 1600
Input W 190 190
Outdoor fan motor
Speed rpm 900±40 900±40
Outdoor air flow m3/h 7500 7500
Outdoor noise level (Sound pressure level) dB(A) 65 65
Outdoor dimension Unit/Packing (WxDxH) mm 950×370×1350/1090×480×1500 950×370×1350/1090×480×1500
Outdoor weight Net/Gross kg 105/118 108/118
Type R410A R410A
Refrigerant
Charge g 4000 3700
Liquid side/Gas side mm 9.52/19.05 9.52/19.05
Refrigerant pipe Max. refrigerant pipe length m 50 50
Max. difference in level m 30 30
Operation temperature range ℃ 16-30 16-30
Ambient temperature range ℃ 10~52 10~52
Qty’per 20’& 40’&40HQ Set 21/41/48 21/41/48

5
Specification
York Set Model YEKE48BZL3CJOW3 YEKE48BZR3CJOW3 YEKE60BZR3CJOW3
York Outdoor Model YEKE48BYL3CJO-3 YEKE48BYR3CJO-3 YEKE60BYR3CJO-3
York Indoor Model YEKE48BXL3CJ-W3 YEKE48BXL3CJ-W3 YEKE60BXL3CJ-W3
Power supply Ph/V/Hz 1/220~240/60 3/380~415/60 3/380~415/60
Power supply at rated capacity Ph/V/Hz 1/230/60 3/400/60 3/400/60
Capacity Btu/h 46,000(18,000~62,000) 46,000(18,000~62,000) 54,000(18,000~72,000)
Capacity kW 13.5(5.27~18.2) 13.5(5.27~18.2) 15.8(5.27~21.09)
Input kW 3.71 3.71 4.35
Rated Cooling(T1)
Running current A 17.30 6.20 7.20
EER W/W 3.63 3.63 3.63
EER Btu/hW 12.40 12.40 12.40
Capacity Btu/h 43,600(15,000~52,000) 43,600(15,000~52,000) 48,600(15,000~55,000)
Capacity kW 12.75(4.40~15.2) 12.75(4.40~15.2) 14.25(4.40~16.12)
Input kW 5.00 5.00 5.586
Rated Cooling(T3)
Running current A 23.80 8.10 8.8
EER W/W 2.55 2.55 2.55
EER Btu/hW 8.70 8.70 8.7
Capacity Btu/h 53,920(20,477~71,669) 53,920(20,477~71,669) 60,000(20,477~72,000)
Capacity kW 15.80(6.0~21.0) 15.80(6.0~21.0) 17.60(6.0~21.0)
Input kW 4.39 4.39 4.89
Rated Heating(T1)
Running current A 20.50 5.09 8.00
COP W/W 3.60 3.60 3.60
COP Btu/hW 12.30 12.30 12.30
Moisture Removal l/h 1.1 1 1
Max. input consumption W 9600 9600 10600
Max. current A 36 12 14
Operation Control Wired Wired Wired
Input W 300 300 1210
Output W 197 197 980
Indoor fan motor Running current A 1.3 1.3 5.5
Capacitor uF / / /
Speed rpm 1100/910/800/750 1100/910/800/750 950/880/850/810
Indoor air flow m3/h 3980/3300/2750/2280 3980/3300/2750/2280 3980/3300/2750/2280
External static pressure Pa 50(0~160) 50(0~160) 50(0~160)
Indoor noise level (Sound pressure level) dB(A) 50/47/45/42 50/47/45/42 51/48/46/43
Unit (WxDxH) mm 1350×490×425 1350×490×425 1336×750×500
Indoor dimension
Packing (WxDxH) mm 1565/724/510 1565/724/510 1609×946×649
Indoor weight Net/Gross kg 61/72 61/72 99/130
Type rotary rotary rotary
Capacity W/h 13780 13780 13780
Input W 4130 4060 4060
Compressor
Rated current(RLA) A 15.8 12.3 12.3
Thermal protector external external external
Refrigerant oil ml 1600 1600 1400
Input W 190 190 190
Outdoor fan motor
Speed rpm 900±40 900±40 900±40
Outdoor air flow m3/h 7500 7500 7500
Outdoor noise level (Sound pressure level) dB(A) 65 65 65
Outdoor dimension Unit/Packing (WxDxH) mm 950×370×1350/1090×480×1500 950×370×1350/1090×480×1500 950×370×1350/1090×480×1500
Outdoor weight Net/Gross kg 125/135 125/135 125/135
Type R410A R410A R410A
Refrigerant
Charge g 5000 5000 5300
Liquid side/Gas side mm 9.52/19.05 9.52/19.05 12.7/19.05
Refrigerant pipe Max. refrigerant pipe length m 75 75 75
Max. difference in level m 30 30 30
Operation temperature range ℃ 16-30 16-30 16-30
Ambient temperature range ℃ 10~52 10~52 10~52
Qty’per 20’& 40’&40HQ Set 21/41/48 21/41/48 21/41/48

Nominal testing conditions:


T1 Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 95°F DB / 75.2°F WB (35°C DB / 24°C WB)
Heating - Indoor 68°F DB / 59°F WB (20°C DB / 15°C WB) & Outdoor 44.6°F DB / 42.8°F WB (7°C DB / 6°C WB)
T3 High ambient cooling test conditions: Cooling - Indoor 84.2°F DB / 66.2°F WB (29°C DB / 19°C WB) & Outdoor 114.8°F DB / 75.2°F WB (46°C DB / 24°C WB)
*This product is coming with holding refrigerant charge from the factory. Refrigerant charge must be checked before startup to assure design performance.

Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other
trademarks used herein may be trademarks or registered trademarks of other companies.
FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM
© 2020 Johnson Controls, Inc, P.O. Box 423, Milwaukee, WI 53201, All rights reserved worldwide. SEKEBZL(R)-200825(KSA)
R410A T3 Inverter Ducted

YEKE18BYL3CJO-3
YEKE24BYL3CJO-3

YEKE36BYL3CJO-3
YEKE42BYL3CJO-3
YEKE42BYR3CJO-3
YEKE48BYL3CJO-3
YEKE48BYR3CJO-3

NO.0150541486
Contents
__________________________________________
Definitions 3
Safety considerations 3
Before installation 6
Selecting installation site 7
Precautions on installation 9
Refrigerant pipe size and allowable
pipe length 10
Refrigerant piping 13
Leak test and vacuum drying 15
Charging refrigerant 16
Electrical wiring work 17
Test operation 19
Move and scrap the air conditioning 24
Technical specification ------------------------------------------------------------------------------------------ 25
1. Definitions Service company:
Qualified company which can perform or coordinate the
required serice to the unit.
1.1. Meaning of warnings and symbols
Warnings in this manual are classified according to their Applicable legislation:
severity and probability of occurrence. All international, European, national and local directives,
laws, regulations and/or codes which are relevant and
DANGER applicable for a certain product or domain.

Indicates an imminently hazardous situation which, if not Accessories:


avoided, will result in death or serious injury.
Equipment which is delivered with the unit and which needs
to be installed according to instructions in the documentation.
WARNING
Optional equipment:
Indicates a potentially hazardous situation which, if not
Equipment which can ooptionally be combined to the products
avoided, could result in death or serious injury.
as per the subject of this manual.

CAUTION Field supply:


Equipment which needs to be installed according to
Indicates a potentially hazardous situation which, if not
instructions in this manual.
avoided, may result in minor or moderate injury. It may
also be used to alert against unsafe practices.

NOTICE
Indicates situations that may result in equipment or
property-damage accidents only. 2. Safety considerations
Applicable ambient temperature range:
INFORMATION
Rated Maximum Minimum
This symbol identifies useful tiops or additional information. DB C 27 32 18
Indoor
WB C 19 23 14
Some types of danger are represented by special symbols: Cooling
DB C 35 52 18
outdoor
WB C 24 32 14
Electric current. DB C 20 27 15
Indoor
WB C 14.5 -- --
Heating
DB C 7 24 -7
Danger of burning and scalding. outdoor
WB C 6 18 --

1.2. Meaning of used terms The precautions here, all cover very impertant topics, so be
sure to follow them catefully.
Installation manual:
Instruction manual specified for a certain product or application, All activities described in this manual shall be carried out by
explaining how to install, configure and maintain it. an installer.

Operation manual: Be sure to wear adequate personal protection equipment (


Instruction manual specified for a certain product or application, Protection gloves, safety glasses......) when performing
explaining how to operate it . installation, maintenance or service to the unit.

Maintenance instructions: If not sure of installation procedures or operation of the unit,


always contact your local dealer for advice and information.
Instruction manual specified for a certain product or application,
which explains ( if relevant ) how to install, configute, operate
Improper installation or attachment of equipment or
and/or maintain the product or application.
accessories could result in electric shock, short-circuit, leaks,
Dealer: fire or other damage to the equipment. Be sure only to use
accessories, optional equipment and spare parts made by
Sales distributor for products as per the subject of this manual.
which are specially designed for use with the products as
of subject in this manual and have them installed by an
Installer
installer.
Technical skilled person who is qualified to install products
as per the subject of this manual.
User:
Person who is owner of the product and/or operates the
product.
3
1.This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
2.Children should be supervised to ensure that they do not play with the appliance.
3.If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
4.We recommend that this air-conditioner be installed properly by qualified installation technicians in
accordance with the installation instructions provided with the unit.The appliance shall be installed in
accordance with national wiring regulations.

5.Wiring must be done by a qualified electrician. All the wiring must comply with the local electrical codes.

6.Means for disconnection, such as circuit breaker, which can provide full disconnection in all poles, must be
incorporated in the fixed wiring in accordance with the wiring rules.Use an ELB (Electric Leakage Breaker).
If not used, it will cause an electric shock or a fire.
Details of type and rating of fuses, or rating of circuit breakers / ELB is detailed in below part.
7.The method of connection of the appliance to the electrical supply and interconnection of separate components
is detailed in below part.The wiring diagram with a clear indication of the connections and wiring to
external control devices and supply cord is detailed in below part.The cord of the H07RN-F type or the electrically
equivalent type must be used for power connection and interconnection between outdoor unit and indoor unit.
The size of the cord is detailed in below part.
8.In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied
through an external switching device, such as a timer, or connected to a circuit that is regularly switched on
and off by the utility.
9.It is necessary to allow disconnection of the appliance from the supply after installation. The disconnection
may be achieved by incorporating a switch in the fixed wiring in accordance with the wiring rules.During service
and when replacing parts, be sure to disconnect the appliance from its power source. If the disconnection is
not foreseen, a disconnection with a locking system in the isolated position shall be provided

10.The information of dimensions of the space necessary for correct installation of the appliance including
the minimum permissible distances to adjacent structures is detailed in below part.

11.The range of external static pressures for ducted appliances is detailed in below part.

4
Consult your local dealer regarding what to do in case
DANGER: ELECTRICAL SHOCK of refrigerant leakage. When the unit is to be installed in
a small room, it is necessary to take proper measures so
Switch off all power supply before removing the switch that the amount of any leaked refrigerant does not exceed
box service panel or before making any connections the concentration limit in the event of a leakage. Otherwise,
or touching electrical parts. this may lead to an accident due to oxygen depletion.
Be sure to use only the specified accessories and parts
To avoid electric shock, be sure to disconnect the power for installation work.
supply 2 minute or more before servicing the electrical Failure to use the specified parts may result in water
parts. Even after 2 minute, always measure the voltage leakage, electric shocks, fire, or the unit falling.
at the terminals of main circuit capacitors or electrical Install the unit on a foundation that can withstand its
parts. Even after 2 minute, always measure the votage weight.
at the terminals of main circuit capacitors or electrical Insufficient strength may result in the fall of equipment
parts, and before touching, be sure that those voltages and causing injury.
are 50V DC or less. Carry out the specified installation work in consideration
of strong winds, typhoons, or earthquakes.
Improper installation work may result in accidents due to
When service panels are removed, live parts can easily
fall of equipment.
be touched by accident, Never leave the unit unattended
Make sure that all electrical work is carried out by qualified
during installation or servicing when the service panel is
personnel according to the applicable legislation and this
removed.
installation manual, using a separate circuit.
Insufficient capacity of the power supply circuit or improper
DANGER: DO NOT TOUCH PIPING AND INTERNAL electrical capacity of the power supply circuit or improper
PARTS electrical construction may lead to electric shocks or fire.
Make sure that all wiring is secure, using the specified
Do not touch the refrigerant piping, water piping or internal
wires and ensuring that external forces do not act on the
parts during and immediately after operation. The piping
terminal connections or wires.
and internal parts may be hot or cold depending on the
Incomplete connection or fixing may cause a fire.
working condition of the unit.
When wiring between the indoor and outdoor units, and
wiring the power supply, form the wires so that the
Your hand may suffer burns or frostbite if you touch the
fronstside panel can be securely fastened.
piping or internal parts. To avoid injury, give the piping
If the frontside panel is not in place, overheating of the
and internal parts time to return to normal temperature
terminals, electric shocks or a fire may be caused.
or, if you must touch them, be sure to wear protective
If refrigerant gas leaks during installation work, ventilate
gloves.
the area immediately.
Toxic gas may be produced if refrigerant gas comes into
contactwith fire.
After completing the installation work, check to make
sure that there is no leakage of refrigerant gas.
Toxic gas may be produced if refrigerant gas leaks into
the room and comes into contact with a source of fire,
Warning: such as a fan heater, stove or cooker.
When planning to relocate former installed units, you
Ask your dealer or qualified personnel to carry out must first recover the refrigerant after the pump down
installation work. Do not install the machine by yourself. operation.
Improper installation may result in water leakage, Never directly touch any accidental leaking refrigerant.
electric shocks or fire. This could result in severe wounds caused by frostbite.
Be sure to install an earth leakage circuit breaker in
Perform installation work in accordance with this installation
accordance with applicable legislation. Failure to do so
manual.
may cause electrical shock and fire.
Improper installation may lead to water leakage, electric
shocks or fire.
The equipment is not intended for use in a potentially
explosive atmosphere.
For year round cooling applications with low indoor humidity
conditions, such as Electronic Data Processing rooms,
contacet yout dealer or see the engineering databook or
the service manual.

5
Caution:
Earth the unit.
3. Before installation
Earthing resistance should be according to applicable
3.1. Scope of this manual
legislation. This manual describes the procedures for handling,
Do not connect the earth wire to gas or water pipes, installing and connecting 18K~48K units.
lightning conductor or telephone earth wire. 3.2. Precautions
Incomplete earthing may cause electric shocks.
Gas pipe. CAUTION
Lgnition or explosion may occur if the gas leaks. Since maximum working pressure is 4.5 MPa or 45 bar,
Water pipe. pipes of larger wall thickness may be required. Refer to
Hard vinyl tubes are not effective earths. paragraph "6.2. Selection of piping material" on page
Lightning conductor or telephone earth wire. 10.
Electric potential may rise abnormally if struck by a
lightning bolt. NOTICE: Insulation resistance of the compressor
Install drain piping according to this installation manual If, after installation, refrigerant accumulates in the
to ensure good drainage, and insulate the pipe to prevent compressor, the insulation resistance can drop, but if it
condensation. is at least 1 , then the machine will not break down.
Improper drain piping may cause water leakage, and Turn the power on and leave it on for six hours. Then,
make the fumitures get wet. check if the insulation resistance of the comressor has
Install the indoor and outdoor units, power wire and risen or not.
connecting wire at least 1 meter away from televisions The compressor will heat up and evaporate any refrigerant
or radios to prevent image interference or noise. in the compressor.
(Depending on the radio waves, a distance of 1 meter
may not be sufficient to eliminate the noise.) Check the following if the ground-fault circuit interrupter is
Do not rinse the outdoor unit, This may cause electric triggered:
shocks or fire. Make sure that the interrupter is compatible with high
Do not install the unit in places such as the following: frequencies.
Where there is mist of mineral oil, oil spray or vapour This unit has an inverter, so an interrupter capable of
for example a kitchen. handling high frequencies is needed to prevent
Plastic parts may deteriorate, and cause them to fall malfunction of the interrupter itself.
out or water to leak.
Where corrosive gas, such as sulphurous acid gas, 3.3. Precautions for R410A
is produced.
Corrosion of copper pipes or soldered parts may cause The refrigerant requires strict cautions for keeping the
the refrigerant to leak. system clean, dry and tight.
- Clean and dry
Where there is machinery which emits electromagnetic
Foreign materials (including mineral oils or moisture)
waves.
should be prevented from getting mixed into the system.
Electromagnetic waves may disturb the control system,
- Tight
andcause malfunction of the equipment.
Read "9. Precautions on refrigerant piping" on page 10
Where flammable gases may leak, where carbon fiber
carefully and follow these procedures correctly.
or ignitable dust is suspended in the air or where volatile
Since R410A is a mixed refrigerant, the required additional
flammables, such as thinner or gasoline, are handled.
refrigerant must be charged in its liquid state.(If the
SUch gases may cause a fire.
refrigerant is in state of gas, its composition changes
Where the air contains high levels of salt such as that
and the system will not work properly).
near the ocean.
The connected indoor units must be indoor units designed
Where voltage fluctuates a lot, such as in factories.
exclusively for R410A.
In vehicles or vessels.
Where acidic or alkaline vapour is present.
3.4. Installation
Do not allow a child to mount on the outdoor unit or
avoid placing any object on the unit. Falling or tumbling For installation of the indoor unit(s), refer to the indoor
may result in injury. unit installation manual.
The unit may stop for several minutes during normal Illustrations show YEKE42BYR3CJO-3
operation for "defrosting the unit", or when in "thermostat YEKE48BYR3CJO-3 outdoor unit type. Other types also
stop" operation. follow this installation manual.
This appliance is intended to be used by expert or trained This outdoor unit requires the pipe branching kit(optional)
users in shops, in light industry and on farms, or for when used as the outdoor unit for the simultaneous
commercial use by lay persons. operation system. Refer to catalogues for details.
Provide a logbook Never operate the unit with a damaged or disconnected
In accordance with the relevant national and discharge thermistor and suction thermistor, burning of
international codes, it may be necessary to provide a the compressor may occur.
logbook with the equipment containing at least Be sure to confirm the model name and the serial no.
- info on maintenance. - repair work, of the outer(front) plates when attaching/detaching the
- results of tests, - stand-by periods, plates to avoid mistakes.
- etc... When closing the service panels, take care that the
6 tigntening torque does not exceed 4.1 N.M.
3.5. Accessories - Do not climb, sit or stand on top of the unit.
- Be sure that sufficient precautions are taken, in
Check if the following accessories are included with the unit: accordance with applicable legislation, in case of
See the figure below for the location of the accessories. refrigerant leakage.

installation NOTICE
manual
This is a class A product. In a domestic environment
this product may cause radio interference in which case
the user may be required to take adequate measures.

When installing the unit in a place exposed to strong


wind, pay special attention to the following.
Strong winds of 5 m/sec or more blowing against the
outdoor unit's air outlet causes short circuit (suction of
discharge air), and this may have the following
consequences:
- Deterioration of the operational capacity.
- Frequent frost acceleration in heating operation.
- Disruption of operation due to rise of high pressure.
rubber base - When a strong wind blows continuously on the face
foot of the unit, the fan can start rotating very fast until it
breaks.
Refer to the figures for installation of this unit in a place
4. Selecting installation site where the wind direction can be foreseen.
Repare a water drainage channel around the foundation,
4.1. General to drain waste water from around the unit.
If the water drainage of the unit is not easy, please build
up the unit on a foundation of concrete blocks, etc.(the
WARNING height of the foundation should be maximum 150mm).
If you install the unit on a frame, please install a waterproof
Be sure to provide for adequate measures in order plate(field supplu) within 150mm of the underside of the
to prevent that the outdoor unit be used as a shelter unit in order to prevent the invasion of water from the
bye small animals. lower direction.
Small animals making contact with electrical parts When installing the unitin a place frequently exposed to
can cause malfunctions, smoke or fire. Please instruct snow, pay special attention to elevate the foundation as
the customer to keep the area around the unit clean. high as possible.
Make sure that the unit is installed level.

Select an installation site where the following conditions


are satisfied and that meets with your customer's approval.
- Places which are well-ventilated.
- Pllaces where the unit does not bother next-door 4.2. General
neighbours.
- Safe places which can withstand the unit's weight and
vibration and where the unit can be installed level. NOTICE
- Places where there is no possibility of flammable gas
or product leak. When operating the outdoor unit in a low outdoor
- The equipment is not intended for use in a potentially amnient temperature, be sure to follow the instructions
explosive atmosphere. described below.
- Places where servicing space can be well ensured.
- Places where the indoor and outdoor units's piping and
wiring lengths come within the allowable ranges. To prevent exposure to wind, install the outdoor unit with
- Places where water leaking from the unit cannot cause its suction side facing the wall.
damage to the location (e.g. in case of a blocked drain Never install the outdoor unit at a site where the suction
pipe) side may be exposed directly to wind.
- Places where the rain can be avoided as much as To prevent exposure to wind, install a baffle plate on the
possible. air discharge side of the outdoor unit.
- Do not install the unit in places often used as work place. In heavy snowfall areas it is very important to select an
In case of construction works (d.g.grinding works ) where installation site where the snow will not affect the unit
a lot of dust is created, the unit must be covered. and set the outlet side at a right angle to the direction
- Do not place any objects or equipment on top of the of the wind.
unit( top plate).
7
8
5. Precautions on installation If the coating on the fastening area is stripped off, the
nuts rust easily.
Dimensions (bottom view)(unit of measurement:mm)

NOTICE
If drain holes of the outdoor unit are covered by a
mounting base or by floor surface, raise the unit in order
to provide a free space of more than 130mm under the
outdoor unit.

36K
H

A leg pitch1 42K 24K 18K


B leg pitch2 48K
C Front grill(air outlet side) A 600 660 630
D Drain hole B 405-410 380-420 350-380
H

E Bottom frame C 450 440 405


130mm
130mm

K Knock-out hole D 368 372 340


(for piping line) W 950 920 890
H 1350 760 695
5.2.Selection of installation location of outdoor
(1)Single-unit installation (unit: mm)

5.1. Foundation work Back 42K


48K
Check the strength and level of the installation ground
so that the unit will not cause any operating vibration or A
noise after installation.
In accordance with the foundation drawing in the figure,
fix the unit securely by means of the foundation bolts.
(Prepare four sets of M12 foundation bolts, nuts and
washers each which are available on the market.) Front
It is best to screw in the foundation bolts until their length
are 20mm from the foundation surface.
Above 1000

Back and side

Height of barriers is
B

below that of outdoor unit

Fix the outdoor unit to the foundation bolts using nuts


with resin washers(1) as shown in the figure.
Above 150 Above 300

Front and back

1
C
Above 1000

9
When barriers exist above the unit 5.3. Drain pipe disposal

Above 1000
D Make sure the drain works properly.
Above 500 In regions where buildups of snow can be expected, the
accumulation and freezing of snow in the space between
the heat exchanger and external plate may lower operating
efficiency.
Above
1000
After punching the knock-out hole, the application of
repair-type paint on the surface around the edge sections
is recommended to prevent rust.
The top and two side surfaces must be exposed to open
space, and barriers on at least one side of the front and back
shall be lower than the outdoor unit.
(2) Multi-unit installation (unit: mm)
Back and side

6. Refrigerant pipe size and


allowable pipe length
E

Above 150 Above 300


DANGER
Above 300 Above 300
Piping an other pressure containing parts shall
Front and back comply with the applicable legislation and shall be
suitable for refrigerant. Use phosphoric acide
deoxidised seamless copper for refrigerant.
Installation shall be done by an installer, the choice
F

of materials and installation shall comply with


applicable legislation. In Europe the EN378 is the
Above 1000

application standard that shall be used.

Above 300 Above 300 INFORMATION


Height of barriers is below that of outdoor unit It is forbidden to discharge refrigerant into the atmosphere.
Collect the refrigerant in accordance with the freon
(3) Multi-unit installation in front and back (unit: mm) collection and destruction law.
Standard
NOTICE
To persons in charge of piping work:
Be sure to open the stop valve after piping installing
and vacuuming is complete. (Running the system with
the valve closed may break the compressor.)
Above 1000 G H Above 200
Above 2000
NOTICE

The top and two side surfaces must be exposed to open Do not use flux when brazing the refrigerant piping.
space, and barriers on at least one side of the front and back For brazing, use phosphor copper brazing filler metal
shall be lower than the outdoor unit. (BCuP) which does not require a flux.
(If a chlorine flux is used, the piping will corrode, and
The installation service spaces shown in the illustrations
if the flux contains fluoride, if will cause the coolant oil
are based on an air intake temperature of 35 (DB) for to deteriorate, adversely affecting the coolant piping
COOL operation. In regions where the air intake system.)
temperature regularly exceeds 35 (DB), or if the heat
load of outdoor units is expected to regularly exceed
the maximum operating capacity, reserve a larger space
than that indicated at the air intake side of units.
Regarding the required air outlet space, position the
units with consideration to the space required for the
onsite refrigerant piping work as well. Consult your dealer
if the work conditions do not match those in the drawings.

10
6.1. Necessary Tools and Materials
Prepare the following tools and materials necessary for installing and servicing the unit.
Necessary tools for use with R410A(Adaptability of tools that are for use with R22 and R407C).
1. To be used exclusively with R410A ( Not to be used if used with R22 or R407C )
Tools/Materials Use Notes

Gauge Manifold Evacuating,refrigerant charging 5.09MPa on the High-pressure side.

Charging Hose Evacuating, refrigerant charging Hose diameter larger than the concentional ones.

Refrigerant Recovery Equipment Refrigerant recovery

Refrigerant Cylinder Refrigerant charging Write down the refrigerant type. Pink in color at the top of the cylinder.

Refrigerant Cylinder Charging Port Refrigerant charging Hose diameter larger than the conventional ones.

Flare Nut Connecting the unit to piping Use Type-2 Flare nuts.

2. Tools and materials that may be used with R410A with some restrictions
Tools/Materials Use Notes

Gas leak detector Detection of gas leaks The ones for HFC type refrigerant may be used.

Vacuum Pump Vacuum drying May be used if a reverse flow check adaptor is attached.

Flare Tool Flare machining of piping Chages have been made in the flare machining dimension.Refer to the next page.

Refrigerant Recovery Equipment Recovery of refrigerant May be used if designed for use with R410A.

3. Tools and materials that are used with R22 or R407C that can also be used with R410A

Tools/Materials Use Notes

Vacuum Pump with a Check Valve Vacuum drying

Bender Bending pipes

Torque Wrench Tightening flare nuts Only 12.70 (1/2'') and 15.88(5/8'') have a larger flare machining dimension.

Pipe Cutter Cutting pipes

Welder and Nitrogen Cylinder Welding pipes

Refrigerant Charging Meter Refrigerant charging

Vacuum Gauze Checking vacuum degree

4. Tool and materials that must not used with R410A


Tools/Materials Use Notes

Charging Cylinder Refrigerant Charging Must not be used with R410A-type units.

Tools for R410A must be handled with special care, and keep moisture and dust from entering the cycle.

11
6.2. Piping Materials
Types of Copper Pipes (Reference)
Maximum Operation Pressure Applicable Refrigerants
3.4MPa R22, R407C
4.5MPa R410A
Use pipes that meet the local standards.
Piping Materials/Radial Thickness
Use pipes made of phosphorus deoxidized copper.
Since the operation pressure of the units that use R410A is higher than that of the units for use with R22, use pipes with
at least the radial thickness specified in the chart below. (Pipes with a radial thickness of 0.7mm or less may not be used.)

Size(mm) Size(inch) Radial Thickness(mm) Type


6.35 1/4'' 0.8t
9.52 3/8'' 0.8t
Type-O pipes
12.7 1/2'' 0.8t
15.88 5/8'' 1.0t
19.05 3/4'' 1.0t Type-1/2H or Hpipes

Although it was possible to use type-O for pipes with a size of up to 19.05(3/4") with conventional refrigerants, use type-
1/2H pipes for units that use R410A.(Type-O pipes may be used if the pipe size is 19.05 and the radial thickness is 1.2t.)
The table shows the standards in Japan. Using this table as a reference, choose pipes that meet the local standards.

Flare Machining (type-O and OL only)


The flare machining dimensions for units that use R410A is larger than those for units that use R22 in order to increase
air tightness.
Flare Machining Dimension(mm)
Dimension A
External dimension of pipes Size
R410A R22
Dimension A

6.35 1/4" 9.1 9.0


9.52 3/8" 13.2 13.0
12.7 1/2" 16.6 16.2
15.88 5/8" 19.7 19.4
19.05 3/4" 24.0 23.3

If a clutch type flare tool is used to machine flares on units that use R410A, make the protruding part of the pipe between
1.0 and 1.5mm. Copper pipe gauge for adjusting the length of pipe protrusion is useful.

Flare Nut
Type-2 flare nuts instead of type-1 nuts are used to increase the strength. The size of some of the flare nuts have also
been changed.
Flare nut dimension(mm)
Dimension B
External dimension of pipes Size
R410A(Type2) R22(Type1)
6.35 1/4" 17.0 17.0
9.52 3/8" 22.0 22.0
12.7 1/2" 26.0 24.0
Dimension B
15.88 5/8" 29.0 27.0
19.05 3/4" 36.0 36.0

Using this table as a reference, choose pipes that meet the local standards.

12
NOTICE
Cautions on handling the service port
For new installations, use the standard pipe sizes.
When using existiong pipes, size-up is allowed as Always use a charge hose equipped with a valve
mentioned in the table above. depressor pin, since the service port is a Schrader type
Additional restrictions towards allowable pipe lengths, valve.
as mentioned in the table 7.3 on page 13, must be After handling the service port, make sure to tighten the
taken into account. service port cap securely. For the tightening torque, refer
Not using the standard lpipe size may result in to the table below.
capacity decrease. The installer must acknowledge Check for refrigerant leaks after tightening the service
this and judge this very carefully in function of the port cap.
complete installation.

7. Refrigerant piping
Existing or pre-installed piping can be used 7.1. Piping diagram for single split

1. Piping must comply with the criteria below.


Flare connection ball valve
Piping diameter must comply with the limitations as Gas pipe
indicated in paragraph "7.2. Refrigerant pipe size " . Indoor Outdoor
Piping length must be withinlimits of the allowable piping unit unit
length as in paragraph "7.3. Allowable pipe length and Liquid
height difference" . pipe
3-way stop valve
Piping must be designed for R410A. See paragraph
"6.2. Selection of piping material" . 7.2. Piping size for single split
Model Pipe Diameter connecting
of pipe method
2. Piping can be reused without cleaning when:
Liquid pipe 9.52mm
YEKE18BYL3CJO-3 flaring
Total 1-way piping length: 50m. YEKE24BYL3CJO-3 connection
Gas pipe 15.88mm
No compressor breakdown has occurred in the history
of the unit to be replaced. YEKE36BYL3CJO-3 YEKE42BYL3CJO-3 Liquid pipe 9.52mm flaring
YEKE42BYR3CJO-3 YEKE48BYL3CJO-3
A correct pump down operation can be executed: YEKE48BYR3CJO-3
Gas pipe 19.05mm
connection
- Operate the unit continuously for 30minutes in cooling
mode.
- Execute a pump down operation.
Install the removed flare nuts
- Remove the air conditioning units to be replaced.
90+0.5 to the pipes to be connected,
Check the contamination inside the existing piping.
then flare the pipes.
If you cannot meet all these requirements, the existing
pipes must be cleaned or replaced after removing the air
conditioning units to be replaced.
7.3. Limitations for one way piping length and vertical
3. Prepare the flare connections for higher pressure. See height difference for single split
paragraph 6.2
YEKE36BYL3CJO-3 YEKE42BYL3CJO-3
YEKE18BYL3CJO-3 YEKE42BYR3CJO-3 YEKE48BYL3CJO-3
Model YEKE24BYL3CJO-3 YEKE48BYR3CJO-3

Cautions on handling the stem cap


One way piping
length less than 50 m less than 75 m
The stem cap is sealed where indicated by the arrow. Vertical height
Take care not to damage it. difference less than 30 m less than 30 m
After handling the stop valve, make sure tighten the stem (between indoor and
cap securely. For the tightening torque, refer to the table outdoor)
below.
Check for refrigerant leaks after tightening the stem cap.

13
Precautions for refrigerant piping Cutting out the two slits makes it possible to install as
shown in the figure "Field pipes in 4 directions".
Do not twist or crush piping.
(Use a metal saw to cut out the slits.)
Be sure that no dust is mixed in piping.
To install the connecting pipe to the unit in a downward
Bend piping with as wide angle as possible.
direction, make a knock-out hole by penetrating the
Keep insulating both gas and liquid piping.
Check flare-connected area for gas leakage. centre area around the knock-out hole using a 6mm
drill (4x).
7.4. Piping connection method After knocking out the knock-out hole, it is recommended
to apply repair paint to the edge and the surrounding
Apply refrigerant oil to the joint and the flange. end surfaces to prevent rusting.
To bend a pipe, give the roundness as possible not to When passing electrical wiring through the knock-out
crush the pipe. holes, remove any burrs from the know-out holes and
When connecting pipe, hold the pipe centre to centre and wrap the wiring with protective tape to prevent damage.
then screw nut on by hand, refer to Fig.
Be careful not to let foreign matters, such as sands enter
the pipe.
Spanner

7.5. Preventing foreign objects from entering


Joint Plug the pipe through-holes with putty or insulating
material (procured locally) to stop up all gaps, as shown
Spanner Nut
in the figure.

Pipe diameter Fastening torque (N.m)


Liquid pipe 6.35mm 14.2-17.2
Liquid pipe 9.52mm 32.7-39.9
Gas pipe 12.7mm 49.5-60.3
Gas pipe 15.88mm 61.8-75.4
Gas pipe 19.05mm 97.2-118.6
Field pipes can be installed in four directions (A, B, C,
D, E).

1 Putty or insulating material (produced locally)

If there is any possibility that small animals enter the system


through the knock-out holes, plug the holes with packing
materials (field supplied).

Insects or samall animals entering the outdoor unit may cause


a short circuit in teh electrical box.

Seal knock-out holes to avoid snow and humidity entering.

7.6. Preventing foreign objects from entering


E
*

Be careful not to let the indoor and outdoor piping come


A B C into contact with the compressor terminal cover.
If the liquid-side piping insulation might come into contact
with it, adjust the height as shown in the figure below.
*

Also, make sure the field piping does not touch the bolts
D or outer panels of the compressor.
A: Forward
When the outdoor unit is installed above the indoor unit
B: Sideways
the following can occur:
C: Backward
The condensed water on the stop valve can move to the
D: Downward
indoor unit. To avoid this, please cover the stop valve with
E: Power supply cable,outdoor and indoor connection cable
sealing material.
14
If the temperature is higher than 30 and the humidity is
higher than RH 80 , then thickness of the sealing materials
NOTICE
should be at least 20mm in ouder to avoid condensation
on the surface of the sealing. Do not purge the air with refrigerants. Use a vacuum
Be sure to insulate the liquid and gas-side field piping. pump to evacuate the installation. No additional
refrigerant is provided for air purging.
Make sure that the gas stop valve and liquid stop
valve are firmly closed before performing the leak
test or vacuum drying.
NOTICE

Any exposed piping may cause condensation.


8.2. Leak test
(The highest temperature that the gas-side piping can The leak test must satisfy specification EN378-2.
reach is around 120 , so be sure to use insulating
material which is very resistant.) 1 Vacuum leak test
1.1 Evacuate the system from the liquid and gas piping
to -100.7 kPa(5 Torr).
1.2 Once reached, turn off the vacuum pump and check
DANGER that the pressure does not rise for at least 1 minute.
No not touch piping and internal parts. 1.3 Should the pressure rise, the system may either
contain moisture (refer to the paragraph " Vacuum
drying ") or have leaks.
2 Pressure leak test
2.1 Break the vacuum by pressurizing with nitrogen gas
7.7. Cautions for necessity of a trap to a minimum gauge pressure of 0.2 MPa (2 bar).
Never set the gauge pressure higher than the
To avoid the the risk of oil held inside the riser piping flowing maximum operation pressure of the unit, i.e. 4.0MPa
back into the compressor when stopped and causing liquid (40bar).
compression phenomenon, or cases of deterioration of oil 2.2 Test for leaks by applying a bubble test solution to
return, it will be necessary to provide a trap at each difference all piping connections.
in height of 10m in the riser gas piping.

A trap is not necessary when the outdoor unit is installed NOTICE


at higher position than the indoor unit.
Make sure to use a recommended bubble test solution
from your wholesaler.
Do not use soap water, which may cause cracking of
8. Leak test and vacuum falre nuts (soap water may contain salt, which absorbs
drying moisture that will freeze when the piping gets cold).
and/or lead to corrosion of flared joints (soap water may
contain ammonia which causes a corrosive effect between
the brass flare nut and the copper flare).
When all piping work is complete and the outdoor unit is
connected to the indoor unit, it is necessary to :

check for any leakages in the refrigerant piping 8.3. Vacuum drying
to perform vacuum drying to remove all moisture in the
refrigerant piping. To remove all mositure from the system, proceed as follows:
1 Evacuate the system for at least 2 hours to a target
If there is a possibility of moisture being present in the vacuum of -100.7 kPa(=-1.007 bar).
refrigerant piping (for example, rainwater may have entered 2 Check that, with the vacuum pump turned off, the target
the piping), first carry out the vacuum drying procedure vacuum is maintained for at least 1 hour.
below until all moisture has been removed. 3 Should you fail to reach the target vacuum within 2 hours
or maintain the vacuum for 1 hour, the system may contain
too much moisture.
8.1. General guidelines 4 In that case, break the vacuum by pressurizing with
nigrogen gas to a gauge pressure of 0.05 MPa (0.5bar)
All piping inside the unit has been factory tested for leaks. and repeat steps 1 to 3 unit all moisture has been removed.
Use a 2-stage vacuum pump with a non-return valve 5 The stop valves can now be opened, and/or additional
which can evacuate to a gauge pressure of-100.7kPa(5 refrigerant can be charged .
Torr absolute,-755mm Hg).
Connect the vacuum pump to both the service port of
the gas stop valve and the liquid stop valve to increase
efficiency.
15
This unit requires additional charging of refrigerant
according to the length of refrigerant piping connected
INFORMATION at the site.
Make sure to charge the refrigerant in liquid state to the
After opening the stop valve, it is possible that the
liquid pipe. Since R410A is a mixed refrigerant, its
pressure in the refrigerant piping does not rise. This
composition changes if charged in its gaseous state and
migeh be caused by e.g. the closed state of the
normal system operation would then no longer be assured.
expansion valve in the outdoor unit circuit, but does not
Before charging, check whether the refrigerant cylinder
present any problem for correct operation of the unit.
has a suphon attached or not and position the cylinder
accordingly.

Fill using a cylinder Fill using a cylinder


with a siphon with a siphon attached
9. Charging refrigerant attached Charge the Charge the liquid
liquid refrigerant with refrigerant with the
the cylinder in upright cylinder in up-side-
9.1. Important information regarding the position. down position.
refrigerant used
On this model it is not necessary to charge additionally if
This product contains fluorinated greenhouse gases
the piping length 30m.
covered by the Kyoto Protocol. Do not vent gases into
the atmopsphere.
Evacuate Indoor Unit and interconnecting pipework to
a vacuum pressure of 500 microns and hold for 15
minutes. 9.3. Complete recharging
The Outdoor unit is supplied with refrigerant HFC-410A
(R410A) sufficient for 30m line length.
Calculate additional refrigerant to suit your line length;
refer supplied Specification Sheet.
Open the service valve at the Outdoor unit to allow NOTICE
refrigerant to flow throughout the system.
For long line lengths, oil (of the correct type) should be Berore recharging, make sure to execute vacuum
added to the refrigerant system at the rate shown in the drying of the intermal piping of the unit as well. To do
Specification Date table.(see paragraph 9.5)
Leak check all brazed and fitted joints. so, use the internal service port of the unit. Do not use
the service ports located on the stop valve, since
vacuum drying can not be performed properly from
these ports.
Outdoor units have 1 port on the piping. It is between
9.2. Precautions and general guidelines
the heat exchanger and the 4-way valve.
When servicing the unit requires the refrigerant system
to be opened, treatment and evacuation of refrigerant
must be done in accordance with applicable legislation. In case complete recharging is required (after a leak, etc.),
Refrigerant can not be charged until field wiring has been refer to teh information below to determine the necessary
completed. amount of refrigerant.
Refrigerant may only be charged after performing the
leak test and vacuum drying.

CAUTION WARNING
When charging a system, care shall be taken that
Some sections of the refrigerant circuit may be
its maximum permissible charge is never exceeded,
isolated from other sections caused by components
in view of the danger of liquid hammer.
with specific functions (e.g. valves). The refrigerant
circuit therefore features additional service ports for
WARNING vacuuming, pressure relief or pressurizing the circuit.
In case it is required to perform brazing on the unit,
Refrigerant cylinders shall be opened shlowly. ensure that there is no pressure remaining inside
Always use protective gloves and protect your eyes the unit. Internal pressures need to be released with
when charging refrigerant. ALL the service ports indicated on the figures below
opened. The location is depending on mode type.
DANGER

When the power is on, please close the front panel


when leaving the unit unattended.
Charging with an unsuitable substance may cause
explosions and accidents, so always ensuren that
the appropriate refrigerant (R410A) is charged.
16
10. Electrical wiring work
WARNING

All wiring must be performed by an authorized


electrician.
All components procured on the side and all elecrtic
construction shall comply with the applicable
legislation.

DANGER: HIGH VOLTAGE

To avoid electrical shock, make sure to disconnect the


power supply 1 minute or more before servicing the
electrical parts. Even after 1 minute, always measure
the voltage at the terminals of main circuit capacitors
or electrical parts and, before touching , make sure that
those voltages are 50VDC or less.
9.4. Total charging weight of the refrigerant
(after a leak, etc.)
The total charging amounts relate to the refrigerant piping
length.
Refrigerant piping length (liquid side) NOTICE
Model
To persons in charge of electrical wiring work:
(a)

60-70m

70-75m
40-50m
30-40m
20-30m
10-20m

50-60m
5-10m

Do not oerate the unit until the refrigerant piping is


complete. (Running it before the piping is ready will
break the compressor.)
YEKE18BYL3CJO-3
YEKE24BYL3CJO-3 2.5 2.5 2.5 2.95 3.4 - - -

YEKE36BYL3CJO-3 2.5 2.5 2.5 2.95 3.4 3.85 - -

YEKE42BYL3CJO-3
YEKE42BYR3CJO-3
YEKE48BYL3CJO-3
YEKE48BYR3CJO-3
3.7 3.7 3.7 4.15 4.6 5.05 5.5 5.95
10.1. Precautions on electrical wiring work

When servicing the unit requires the refrigerant system


to be opened, treatment and evacuation of refrigerant
must be done in accordance with applicable legislation.
9.5 Add oil instruction Refrigerant can not be charged until field wiring has been
The cumout of oil added can be calculated by the following completed.
formula :Q=(A+(L-30)*B)/4-C Refrigerant may only be charged after performing the
leak test and vacuum drying.
factory refrigerant recharge factory oil
mode charge quantity charging
A(g) B(g/m) C(cc)
YEKE18BYL3CJO-3 1850 45 350 DANGER
YEKE24BYL3CJO-3 2000 45 350 Before obtaining access to terminal devices, all
YEKE36BYL3CJO-3 3700 45 520 supply circuits must be interrupted.
Be sure to install an earth leakage circuit breaker
YEKE42BYL3CJO-3 4000 45 870
in accordance with aplicable legislation. Failure to
YEKE42BYR3CJO-3 3700 45 870 do so may cause electrical shock.
YEKE48BYL3CJO-3
YEKE48BYR3CJO-3 5000 45 1400

17
Use only copper wires. Outdoor unit
A main switch or other means for disconnection, having L N 1 2 3
terminal blocks
a contact separation in all poles, must be incorporated
YEKE18BYL3CJO-3
in the fixed wiring in accordance with applicable legislation.
YEKE24BYL3CJO-3
Do not turn on the main switch until all the wiring is Power supply: YEKE36BYL3CJO-3
completed. 1PH,220-240V~, YEKE42BYL3CJO-3
Make sure to connect power supply cables in normal 60Hz
YEKE48BYL3CJO-3
phase.
1 2 3 Indoor unit
Never squeeze bundled cables into a unit.
terminal blocks
Fix cables so that cables do not make contact with the
pipes (especially on high pressure side). YEKE18BXL3CJ-W3
YEKE24BXL3CJ-W3
Secure the electrical wiring with cable ties as shown in
YEKE36BXL3CJ-W3
the figure in 10.2 . YEKE42BXL3CJ-W3
Make sure no external pressure is applied to the terminal YEKE48BXL3CJ-W3
connectors.
When installing the earth leakage circuit breaker make YEKE18BYL3CJO-3,YEKE24BYL3CJO-3,YEKE36BYL3CJO-
sure that it is compatible with the inverter (resistant to 3
high frequency electrical noise ) to avoid unnecessary
opening of the earth leakage circuit breaker. YEKE42BYL3CJO-3,YEKE48BYL3CJO-3
As this unit is equipped with an inverter, installing a phase
advancing capacitor not only will deteriorate power factor
improvement effect, but also may cause capacitor
abnormal heating accident due to high-frequency waves.
Therefore, never install a phase advancing capacitor.

Fix the cable with the clip to prevent slide.


CAUTION
Clip
Be sure to install the required fuses or circuit
Clip
breakers.

10.2. Connecting power supply and inter-unit


wiring
Connect and fix the power supply cable, indoor-outdoor
connection cable as following: Outdoor-indoor unit Power supply cable
connection cable
Secure the cable to the stop valve attachment plate so
R S T N 1 2 3 Outdoor unit
that it does not slide.
terminal blocks
When cables are routed from the unit, a protection sleeve
for the conduits (PG-insertions) can be inserted at the
Power supply: knock-out hole.
380-415V,3N~, When you do not use a wire conduit, be sure to protect
60Hz the wires with vinyl tubes to revent the edge of the knock-
1 2 3 Indoor unit out hole from cutting the wires.
terminal blocks Follow the electric wiring diagram for electrical wiring
works.
YEKE42BYR3CJO-3, Multiple copper cores are adopted as the connecting
YEKE48BYR3CJO-3
cables, which have the advantages of highinsulating
grade, excellent heat radiation and durability
YEKE42BYR3CJO-3
YEKE48BYR3CJO-3

18
Form the wires and fix the cover fimmly so that the cover 11.1. Pre-run checks
may be fit in properly.
When you do not use a wire conduit, be sure to protect
the wires with vinyl tubes to revent the edge of the knock- Items to check
out hole from cutting the wires.
Electrical wiring Is the wiring as mentioned on the
Follow the electric wiring diagram for electrical wiring
Inter-unit wiring wiring diagram?
works.
Ground wire Make sure no wiring has been
Form the wires and fix the cover fimmly so that the cover
forgotten and that there are no missing
may be fit in properly.
phases or reverse phases.
- Do not connect wires of different gauge to the same Is the unit properly grounded?
power supply terminal. (Looseness in the connection may Is the wiring between units connected
cause overheating.) in series correct?
Use the correct screwdriver to tighten the terminal screws. Are any of the wiring attachment
Small screwdrivers can damage the screw head and screws loose?
prevent appropriate tightening. Is the insulation resistance at leaset
Over-tightening the terminal screws can damage the 1 ?
screws. - Use a 500V mege-tester when
measuring insulation.
- Do not use a mega-tester for low-
10.3. Specifications of standard wiring voltage circuits.
components
Refrigerant Is the size of the piping appropriate?
CAUTION piping Is the insulation material for the piping
attached securely?
Select all cables and wire sizes in accordance with Are both the liquid and gas pipes
applicable legislation. insulated?
After finishing the electrical work, confirm that each Are the stop valves for both the liquid
electric part and terminal inside the electric part box side and the gas side open?
is connected securely.
The earth leakage breaker must be a high-speed Did you write down the extra
type breaker of 30 mA( 0.1 s). Extra refrigerant
refrigerant and the refrigerant piping
length?

Be sure to perform a test run.


Be sure to fully open the liquid-side and gas-side stop
valves. If you operate the unit with stop valves closed, the
compressor will break down.
Be sure to execute the first test run of the installation in
cooling mode operation.
Never leave the unit unattended with an open front panel
during test run.

11.2. Precautions regarding test-runs


1 In order to detect stop valves failing to open, operation
of the unit is compulsorily performed in cooling for 2-3
minutes during the first test run, even if the remote
11. Test operation controller was set to heating operation. In this case, the
remote controller will have kept displaying the heating
symbol all the time and the unit will switch to heating
operation automatically after elapse of that time.
DANGER 2 In case you cannot operate the unit in test run mode
Never leave the unit unattended during installation for any unusual reason, refer to "11.4. Failure diagnosis
or servicing. When the service panel is removed at the moment of first installation" .
live parts can be easily touched by accident. 3 In case of a wireless remote controller, execute the run
only after having installed the indoor unit decoration
panel with infrared receiver first.
INFORMATION 4 In case the panels of indoor units are not yet installed
Note that during the first running period of the unit, to the indoor units, make sure to shut off the power
required power input may be higher than stated on the supply after finishing the complete test run.
nameplate of the unit. This phenomenon originates 5 A complete test run surely includes shutting off power
from the compressor that needs elapse of a 50 hours after having performed a normal operation stop on the
run in period before reaching smooth operation and remote controller. Do not stop operation by turning circuit
stable power consumption. breakers off.
19
11.3 Before Installing (Relocating) the Unit or Performing Electric Work

CAUTION
Ground the unit. Do not spray water on the air conditioners or immerse the
Do not connect the grounding on the unit to gas pipes,water air conditioners in water.
pipes, lightning rods, or the grounding terminals of Water on the unit presents a risk of electric shock.
telephones. Improper grounding presents a risk of electric
shock, smoke, fire, or the noise caused by improper Periodically check the platform on which is placed for damage
grounding may cause the unit to malfunction. to prevent the unit from falling.
Make sure the wires are not subject to tension. If the unit is left on a damaged plarform, it may topple
over, causing injury.
If the wires are too taut, they may break or generate
heat and/or smoke and cause fire. When installing draining pipes, follow the instructions in the
manual, and make sure that they properly drain water so as
Install a breaker for current leakage at the power source
to avoid dew condensation.
to avoid the risk of electric shock.
Without a breaker for current leakage, there is a risk If not installed properly, they may cause water leaks
of electric shock, smoke or fire. and damage the furnishings.

Properly dispose of the packing materials.


Use breakers and fuses (electrical current breaker, remote
switch<switch+Type-B fuse>,molded case circuit breaker) Things such as nails may be included in the package.
with a proper current capacity. Dispose of them properly to prevent injury.
Plastic bags present a choking hazard to children.
The use of large-capacity fuses, steel wire, or copper Tear up the plastic bags before disposing of them to
wire may damage the unit or cause smoke or fire. prevent accidents.

Before the Test Run

CAUTION

Do not operate switches with wet hands to avoid electric. Do not turn off the power immediately after stopping the unit.
Allow for at least five minutes before turning off the unit,
Do not touch the refrigerant pipes with bare hands during otherwise the unit may leak water or experience other
and immediately after operation. problems.
Depending on the state of the refrigerant in the system,
certain parts of the unit such as the pipes and
compressor may become very cold or hot and may
subject the person to frost bites or burning.

Do not operated the unit without panels and safety guards


in their proper places.
They are there to keep the users from injury from Do not operate the unit without air filters.
accidentally touching rotating, high-tempreture or Dust particles in the air may clog the system and cause
high-voltage parts. malfunction.

20
11.4. Failure diagnosis
Applicable Model :YEKE18BYL3CJO-3 YEKE24BYL3CJO-3

Flash times of
LED on Trouble description Analyze and diagnose
mainboard

1 Eepron failure Outdoor main board eeprom fail

2 IPM failure IPM failure


Communication error between main board
4 and spdu module SPDU Communication Communication fail over 4min
error

5 High pressure protection System high pressure over 4.15 Mpa

Module over-voltage protection (only for Spdu)


6 Module lack-voltage protection (only for Spdu)
Send from Spdu module

Compressor discharging temperature over


8 Compressor discharging temperature protection
110centigrade

9 Abnormal of DC motor Jam of DC motor or motor failure

10 Abnormal of piping sensor Piping sensor short-circuit or open-circuit

Suction temperature sensor short-circuit or open-


11 Abnormal of piping sensor sensor failure
circuit or the compressor connection is poor

Outdoor ambient sensor short-circuit or open-


12 Abnormal of outdoor ambient sensor
circuit
Compressor discharge sensor short-circuit or
13 Abnormal of compressor discharge sensor
open-circuit

Communication error between indoor and


15 outdoor unit
Communication fail over 4min

16 Lack of refrigerant check if there is leakage in the unit

Alarm and stop if detect Td-Tci 15 last for 1min


afte compressor has started for 10min in heating
17 4-way valve reverse failure mode, confirm the failure if it appears 3 times in
one hour.

18 Compressor jam(only for spdu) Inner compressor is abnormal jamed

19 Module PWM select circuit error Module PWM select wrong circuit

25 Compressor U-phase over-current) The current of compressor U-phase is too high

25 Compressor V-phase over-current) The current of compressor V-phase is too high

25 Compressor W-phase over-current) The current of compressor W-phase is too high

21
Applicable Model :YEKE36BYL3CJO-3 YEKE42BYL3CJO-3 YEKE48BYL3CJO-3 YEKE42BYR3CJO-3 YEKE48BYR3CJO-3

22
23
12. Move and scrap the air conditioning
When moving, to disassemble and re-install the air conditioning, please contact your dealer for technical support.
In the composition material of air conditioning, the content of lead, mercury, hexavalent chromium, polybrominated biphenyls
and polybrominated diphenyl ethers are not more than 0.1% (mass fraction) and cadmium is not more than 0.01% (mass
fraction).
Please recycle the refrigerant before scrapping, moving, setting and repairing the air conditioning; for the air conditioning
scrapping, should be dealt with by the qualified enterprises.

24
Technical specification : Inverter R‐
410a
Set YEKE18BZL3CJOW3 YEKE24BZL3CJOW3 YEKE36BZL3CJOW3 YEKE42BZL3CJOW3
No. Model YORK Outdoor YEKE18BYL3CJO-3 YEKE24BYL3CJO-3 YEKE36BYL3CJO-3 YEKE42BYL3CJO-3
Indoor YEKE18BXL3CJ-W3 YEKE24BXL3CJ-W3 YEKE36BXL3CJ-W3 YEKE42BXL3CJ-W3
1 Capacity Btu/h 18000.00 21800.00 33000.00 40000.00
2 Capacity kW 5.28 6.39 9.70 11.70
3 Input kW 1.45 1.76 2.66 3.23
Rated Cooling(T1)
4 Running current A 8.08 10.03 11.90 15.10
5 EER W/W 3.64 3.63 3.64 3.63
6 EER Btu/hW 12.40 12.40 12.40 12.40
7 Capacity Btu/h 16,400 19,600 31,000 37,600
8 Capacity kW 4.8 5.73 9.1 11
9 Input kW 1.890 2.250 3.560 4.320
Rated Cooling(T3)
10 Running current A 10.35 12.33 14.39 18.5
11 EER W/W 2.54 2.55 2.55 2.55
12 EER Btu/hW 8.7 8.7 8.7 8.7
13 Capacity Btu/h 18260 24600 35636 47950
14 Capacity kW 5.35 7.20 10.45 14.05
Rated Hea ng(T1)
15 Rated Hea�ng(H1) Input kW 1.50 2.02 2.94 3.90
16 Running current A 8.14 10.02 13.01 15.15
17 COP W/W 3.55 3.55 3.55 3.60
18 COP Btu/hW 12.12 12.12 12.12 12.30
19 Net kg 31 31 46 61
Indoor weight
20 Gross kg 35 35 55 72
21 Net kg 47 54 82 105
Outdoor weight
22 Gross kg 52 60 92 115
23 Type R410A R410A R410A R410A
Refrigerant
24 Charge g 1850 2000 3700 4000

Set YEKE42BZR3CJOW3 YEKE48BZL3CJOW3 YEKE48BZR3CJOW3


No. Model YORK Outdoor YEKE42BYR3CJO-3 YEKE48BYL3CJO-3 YEKE48BYR3CJO-3
Indoor YEKE42BXL3CJ-W3 YEKE48BXL3CJ-W3 YEKE48BXL3CJ-W3
1 Capacity Btu/h 40000.00 46000.00 46000.00
2 Capacity kW 11.70 13.50 13.50
3 Input kW 3.23 3.71 3.71
Rated Cooling(T1)
4 Running current A 5.50 17.30 6.20
5 EER W/W 3.63 3.63 3.63
6 EER Btu/hW 12.40 12.40 12.40
7 Capacity Btu/h 37,600 43,600 43,600
8 Capacity kW 11 12.75 12.75
9 Input kW 4.320 5.000 5.000
Rated Cooling(T3)
10 Running current A 7.91 23.8 8.1
11 EER W/W 2.55 2.55 2.55
12 EER Btu/hW 8.7 8.7 8.7
13 Capacity Btu/h 47950 53920 53920
14 Capacity kW 14.05 15.80 15.80
Rated Hea ng(T1)
15 Rated Hea�ng(H1) Input kW 3.90 4.39 4.39
16 Running current A 5.55 20.50 5.09
17 COP W/W 3.60 3.60 3.60
18 COP Btu/hW 12.30 12.30 12.30
19 Net kg 61 61 61
Indoor weight
20 Gross kg 72 72 72
21 Net kg 108 125 125
Outdoor weight
22 Gross kg 115 135 135
23 Type R410A R410A R410A
Refrigerant
24 Charge g 3700 5000 5000

25
Long piping and high drop pipe type and capacity
attenuation table
model pipe size 5 10 20 30 40 50 60 75
YEKE18BYL3CJO-3 3/8" 0 0.993 0.991 0.986 0.983
YEKE18BXL3CJ-W3 5/8" 0.986
YEKE24BYL3CJO-3 3/8" 0 0.991 0.988 0.983 0.978 0.971
YEKE24BXL3CJ-W3 5/8" 0.991 0.988 0.983 0.978 0.971
YEKE36BYL3CJO-3 3/8" 0 0.992 0.986 0.981 0.976 0.969
YEKE36BXL3CJ-W3 3/4" 0.972 0.967
YEKE42BYL3CJO-3
3/8" 0 0.99 0.983 0.973 0.968 0.964
YEKE42BYR3CJO-3
YEKE42BXL3CJ-W3 3/4" 0.973 0.966
YEKE48BYL3CJO-3
3/8" 0 0.989 0.98 0.973 0.968 0.955
YEKE48BYR3CJO-3
YEKE48BXL3CJ-W3 3/4" 0.971 0.965
outdoor pipe size 5 10 20 30 40 50 60 75
YEKE18BYL3CJO-3 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8"
YEKE24BYL3CJO-3 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8"
YEKE36BYL3CJO-3 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
YEKE42BYL3CJO-3
3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
YEKE42BYR3CJO-3
YEKE48BYL3CJO-3
3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
YEKE48BYR3CJO-3
indoor pipe size 5 10 20 30 40 50 60 75
YEKE18BXL3CJ-W3 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"
YEKE24BXL3CJ-W3 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"
YEKE36BXL3CJ-W3 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"
YEKE42BXL3CJ-W3 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"
YEKE48BXL3CJ-W3 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2"

26
YEKE18BYL3CJO-3
YEKE18BXL3CJ-W3

YEKE24BYL3CJO-3
YEKE24BXL3CJ-W3

YEKE36BYL3CJO-3
YEKE36BXL3CJ-W3

YEKE42BYL3CJO-3
YEKE42BXL3CJ-W3

YEKE42BYR3CJO-3
YEKE42BXL3CJ-W3

YEKE48BYL3CJO-3
YEKE48BXL3CJ-W3

YEKE48BYR3CJO-3
YEKE48BXL3CJ-W3

27
Section 4
Company Profile
INDUSTRIAL HEALTHCARE RETAIL TRANSPORTATION

HOSPITALITY COMMERCIAL EDUCATION RESIDENTIAL

OVER 140 YEARS OF HVAC SOLUTIONS


CONSULTANT’S GUIDE

* This guide covers 60Hz Products Data | Issued 2019


1
2
Why can’t as this space?
this space
be as perfect
for people

Designing the ideal building environment means thinking about people first. This means putting
quality first and choosing progressive products that give you confidence.

When high performance is your priority, why choose anything but YORK® ? Visit YORK.com.sa
Table of Contents
AIR-COOLED CHILLERS RESIDENTIAL & LIGHT COMMERCIAL UNITS
YORK® YVAA Air-Cooled Screw Chillers with Variable Speed Drive ----- 6 YORK® DX-High Wall Type Split Units - TAURUS Super Cool ---------- 54
YORK® YLAA Air-Cooled Scroll Chillers ----------------------------- 7 YORK® DX-High Wall Type Split Units - ICEBERG-------------------- 55
YORK YCAL Air-Cooled Scroll Chillers ----------------------------- 8
®
YORK® DX-High Wall DC Inverter Split Units - ICEBERG -------------- 56
YORK® DX-High Wall Type Split Units - FROST --------------------- 57
WATER-COOLED CHILLERS YORK® DX-Cassette Split Units - TAURUS Super Cool---------------- 58
YORK YVWA Screw Chillers ------------------------------------ 10
®
YORK® DX-Cassette Type Split Units ------------------------------ 59
YORK YZ Centrifugal Chillers ------------------------------------ 11
®

YORK® DX- Free/Floor Standing Type Split Units -------------------- 60


YORK® YMC² Centrifugal Chillers --------------------------------- 12
YORK® YK Centrifugal Chillers ------------------------------------ 13 YORK® DX-Ducted Residential Split Units -------------------------- 61
YORK® YD Centrifugal Chillers ----------------------------------- 14 YORK® DX-Ducted Light Commercial Split Units -------------------- 62
YORK® TITAN OM Centrifugal Chillers ----------------------------- 15 YORK® Mini VRF High Ambient System Heat Pump ------------------ 63
YORK® Absorption Chillers -------------------------------------- 16 YORK® VRF High Ambient System Heat Pump 50/60 Hz -------------- 64

AIR HANDLING UNITS ALLIED PRODUCTS


YORK® YMA Custom Air Handling Units ---------------------------- 18 YORK® Commercial and Industrial Supply and Exhaust Fans ----------- 68
YORK® Air Handling Units - Market-Leading Features with Patented Designs --- 19 Non-YORK® Allied Products-------------------------------------- 70
YORK® YMA Custom Fresh Air Handling Units with Heat Recovery Wheel ---- 20
YORK® YSM Modular Air Handling Units ------------------------------ 21
YORK® Hygienic Air Handling Units (YMA-H) ----------------------- 22 Product Line Card ----------------------------------------------- 71
YORK® Multi Fans Air Handling Units (YMA–M) --------------------- 23 Minimum Efficiencies for Saudi Arabia------------------------------ 74
YORK YMS Modular Air Handling Units --------------------------- 24
®
Psychrometric Chart--------------------------------------------- 76
Full Integrated Solutions ----------------------------------------- 77
FAN COIL UNITS After Sales Services and Beyond ---------------------------------- 78
YORK® YGFC & YDFC Fan Coil Units ------------------------------- 26
Smart Buildings Demand Smart Controls: Intelligent Solutions for Every Facility -- 79
YORK® YLH, YLIH & YEFB Fan Coil Units --------------------------- 34
Local Manufacturing for a Sustainable Economy---------------------- 80
YORK® ECM Fan Coils - Energy Saving Technology ------------------ 44
Industrial Refrigeration------------------------------------------- 81

AIR COOLED PACKAGED AND CONDENSING UNITS Energy Efficiency for a Sustainable Future -------------------------- 82
YORK® ZH PREDATOR Air Cooled Packaged Units ------------------- 46 Landmark Projects ---------------------------------------------- 84
YORK® DEH STELLAR Air Cooled Packaged Units-------------------- 47
YORK® DEM Medium Air Cooled Packaged Units -------------------- 50
* Click on the title to navigate to its page.
YORK® DCH STELLAR Air Cooled Condensing Units------------------ 51
AIR-COOLED
CHILLERS
YORK® YVAA Air-Cooled Screw Chillers with Variable Speed Drive - North America Origin

YVAA (VSD Twin Screw) Chillers - R134a (60 Hz): 150-500 TR (525-1750 kW)
DIMENSIONS (MM) YORK® YVAA air-cooled variable speed screw chillers provide superior performance. Higher
CAPACITY IPLV WATER FLOW OPER. efficiency heat exchangers coupled with variable speed operation and smart controls elevate
UNIT P.N. COP TPI (KW)
TON (KW/KW) RATE GPM WT.LBS
L W H the system efficiency to a whole new level. The resulting benefit from YVAA chillers is much
YVAA0153 153.9 2.92 185 4.45 368 11,784 5164 2243 2403 greater than the sum of its parts.
YVAA0165 156.8 3.09 178 4.53 375 12,546 6279 2243 2403
YVAA0178 162.5 3.24 176 4.65 389 15,432 7396 2243 2403
YVAA0183 182.5 3.00 214 4.57 437 12,460 6274 2243 2403
YVAA0195 185.4 3.12 209 4.53 444 13,222 7396 2243 2403
Lower annual energy costs
YVAA0198 187.5 3.20 206 4.65 449 14,237 8514 2243 2403
as much as 50% VSD is standard
YVAA0200 206.5 2.63 276.7 4.48 494 14,637 5741 2243 2403 ensuring Zero inrush
YVAA0213 212.0 3.05 244 4.64 507 13,300 7396 2243 2403
Reduce energy consumption intelligently current and longer
YVAA0215 218.0 3.11 246.5 4.72 523 15,678 7396 2243 2403 with standard variable-speed drive equipment life
YVAA0218 221.7 3.22 243 4.69 531 16,440 8514 2243 2403 for the lowest kW/ton at design and
YVAA0233
YVAA0245
231.9
243.4
2.95
3.13
276
273
4.63
4.78
555
583
13,750
16,636
7396
8514
2243
2243
2403
2403
off-design conditions
50%
annual
YVAA0248 244.7 3.21 268 4.85 586 17,398 9632 2243 2403 energy cost
YVAA0263 254.9 2.99 300 4.70 610 14,538 8514 2243 2403
YVAA0270 265.6 2.92 320 4.75 636 16,342 7396 2243 2403 Improve sustainability from
YVAA0273 270.5 3.09 308 4.84 647 17,103 8514 2243 2403 every angle
YVAA0275 275.0 3.13 309 4.90 658 17,851 8514 2243 2403
YVAA0278 277.4 3.22 303 4.92 664 18,612 9632 2243 2403 Lowering energy consumption means
YVAA0295 310.9 3.10 353 4.89 744 19,065 9632 2243 2403 Industry’s Lowest
lower indirect GHG emissions from the
YVAA0303 297.4 3.02 346 4.77 712 17,877 9632 2243 2403 MCA & Breaker
power plant, and reducing refrigerant as Requirements
YVAA0305 300.2 3.10 340 4.78 718 18,638 10747 2243 2403
YVAA0308 313.7 3.19 346 4.91 751 19,827 10747 2243 2403
much as 15% cuts direct emissions
YVAA0318 315.1 3.24 343 4.90 754 20,588 11864 2243 2403
YVAA0323 341.8 2.97 405 4.77 818 19,414 9632 2243 2403
YVAA0333 330.9 2.98 390 4.70 792 18,987 10747 2243 2403
YVAA0343 345.9 3.06 397 4.82 828 20,175 10747 2243 2403
Lower the volume
YVAA0345 348.9 3.14 391 4.84 835 20,937 11864 2243 2403 with 16dBA noise reduction sustanability
YVAA0368 387.7 3.04 449 4.82 928 26,013 12979 2243 2403 from every angle
YVAA0373 370.2 2.92 446 4.70 886 23,230 11864 2243 2403 Variable-speed design dramatically reduces sound levels
YVAA0375 384.5 2.97 454 4.79 920 25,252 11864 2243 2403 at off-design conditions; a variety of sound-attenuation
YVAA0398 424.6 3.01 496 4.79 1,016 27,123 14105 2243 2403 options are available for design conditions High Power factor
YVAA0413 415.1 2.87 508 4.74 994 21,874 11864 2243 2403 of 95% at all Load
YVAA0425 422.3 3.00 494 4.77 1,011 23,397 14105 2243 2403 Conditions.
YVAA0428 426.8 3.05 492 4.76 1,022 27,885 15222 2243 2403
YVAA0443 467.7 2.78 591.8 4.66 1121 27,750 14105 2243 2403 Feel confident with a proven performer
YVAA0475
YVAA0483
494.4
471.1
2.90
2.84
599
584.5
4.77
4.67
1,183
1131
29,609
28,585
15222
15222
2243
2243
2403
2403 Over 4 million tons of YORK® air-cooled variable-speed
16dBA
noise reduction
YVAA0490 478.5 2.67 631.5 4.7 1147 25,660 11864 2243 2403 screw chillers installed worldwide, backed by the world’s
YVAA0500 481.1 2.67 633.8 4.71 1154 28,105 11864 2243 2403
largest service organization
YVAA0523 494.4 2.90 599 4.77 1,183 29,609 15222 2243 2403

Notes: Valve Less


• Quick Selection Chiller Models are Satisfying the Estidama Requirements. Operation, hence
• The above Chiller Selections are rated at AHRI conditions (95°F Ambient Temp. & 44/54°F Chilled Water Leaving/Entering Temp. less moving
• Condenser is with advanced Microchannel design. • Please contact us for your requirement of higher efficiency models. Our unique parts with more
‘tailor and tune’ ability gives chiller configuration to suit your top design priorities Efficiency &
• Optional VSD on Condenser Fan: This will provide further off-design sound benefit and the energy consumption. (efficiency, footprint, sound, etc). Advantages
• All the above units are SASO compliant.

6
YORK® YLAA Air-Cooled Scroll Chillers - Saudi Origin

YLAA Chillers with Brazed Plate Heat Exchangers (60 Hz): 40-230 TR (140-800 kW)
DIMENSIONS (MM) A true plug and play system that provides the highest efficiency for its operation, our YORK®
CAPACITY IPLV WATER FLOW OPER. YLAA Air-Cooled Scroll Chiller allows you to reduce your energy costs while being friendlier
UNIT P.N. COP TPI (KW)
TON (KW/KW) RATE GPM WT.LBS
L W H to the environment. Whether your cooling needs are industrial or commercial, we can help
YLAA0041HE40 39.6 3.41 41 4.89 94 3,347 2576 2243 2393 you put together a complete system including unique features such as the brazed plate
YLAA0048HE40 49.0 3.20 54 4.61 117 3,225 2576 2243 2393
heat-exchanger, microchannel condenser, BAS communications, and high-ambient kit, equipped
with Smart Connected technology.
YLAA0058HE40 57.0 3.11 64 4.57 136 3,545 2576 2243 2393

YLAA0065HE40 62.3 3.05 72 4.57 149 3,739 2576 2243 2393 High energy performance. Proven in the real world.
YLAA0070SE40 71.0 3.04 82 4.71 170 3,933 2949 2243 2393
With advanced technology, air-cooled water chiller systems featuring our
YLAA0080SE40 77.8 2.96 92 4.57 186 3,990 2949 2243 2393 YLAA Chillers offer remarkable real-world performance. Brazed evaporators
and microchannel condensers enable more efficient heat transfer, providing
YLAA0082HE40 78.0 3.02 91 4.70 186 4,136 2576 2243 2393
lower life-cycle costs. YLAA energy savings surpass typical chillers with
YLAA0089SE40 81.8 2.88 100 4.63 195 4,081 2949 2243 2393 annual operating energy cost savings as much as 40%.

YLAA0092HE40 85.7 3.22 94 4.71 205 4,709 3625 2243 2393

YLAA0100SE40 96.5 2.85 119 4.24 230 4,645 3625 2243 2393 More friendly to the environment. And to your neighbors.
YLAA0101HE40 99.3 2.97 117 4.58 237 4,806 3625 2243 2393 Become a leader in environmental design with zero-ODP HFC-410A
refrigerant and up to 50% less refrigerant charge. YLAA chiller responds to the
YLAA0120SE40 120.0 2.87 147 4.38 287 5,095 3626 2243 2393
environmental issue in two ways: directly, by limiting the amount of refrigerant
YLAA0125HE40 118.0 3.01 138 4.48 282 6,043 4768 2243 2393 emitted into the atmosphere, and indirectly, by minimizing power plant CO2
emissions — which are responsible for 98% of the Global Warming Potential associated with chillers.
YLAA0136SE40 125.3 2.84 155 4.63 299 6,186 4768 2243 2393

YLAA0139HE40 126.3 2.97 150 4.68 302 6,488 4768 2243 2393
Wider operating range. Better fit your needs.
YLAA0155SE40 145.3 2.85 180 4.63 347 6,449 4768 2243 2393
Choose from a variety of energy, sound, and mechanical configurations to suit your many
YLAA0156HE40 146.9 2.99 173 4.51 351 7,350 5911 2243 2393
application needs. The YLAA chiller can operate with ambient temperatures up to 125° or down
YLAA0170SE40 170.1 2.85 210 4.54 406 7,707 5911 2243 2393 to 0°F. For process applications, it can be configured for glycol production as low as 10°F. Optional
pumps can be integrated onboard the chassis below the condenser to save space and create a
YLAA0175HE40 175.3 2.87 215 4.54 419 7,888 5911 2243 2393
smaller footprint.
YLAA0200HE40 195.8 2.97 231 4.74 467 9,332 6970 2243 2393

YLAA0230HE40 221.7 2.99 261 4.57 529 9,822 6970 2243 2393 YLAA is Low Noise.
Notes:
No matter where you place a YLAA chiller, it can run quietly – which is ideal for
• The above Chiller Selections are rated at sound-sensitive areas where people are concerned. It offers multiple attenuation options
AHRI conditions (95°F Ambient Temp. & for even further sound reduction.
44/54°F Chilled Water Leaving/Entering
Temp.
• Condenser is with advanced Microchannel
Full life cycle. Lower total cost.
design. Minimize your installation cost, maximize your usable space, lower your electric bills
• Optional VSD on Condenser Fan: This will and reduce your service expenses by choosing a lighter, smaller, more efficient, low
provide further off-design sound benefit and maintenance chiller. YLAA is attractive value right from the start as it can be specifically
the energy consumption. configured so that you only pay for the chiller you need. You save by specifying the efficiency level and the customizable
options that make the most sense for your application in addition to savings on installation costs.
• All the above units are SASO compliant.

7
YORK® YCAL Air-Cooled Scroll Chillers - North America Origin

YCAL Chillers with Brazed Plate Heat Exchangers: (60 Hz) 15-65 TR (50-225 kW)
DIMENSIONS (MM)
Minimize the total cost of ownership for your air conditioning application with our YCAL Air-Cooled
TOTAL
UNIT P.N.
CAPACITY
COP POWER
IPLV WATER FLOW OPER. Scroll Chiller. This air-cooled chiller uses scroll compressor technology and is a reliable, completely
TON (KW/KW) RATE GPM WT.LBS
INPUT (KW) L W H self-contained unit that is designed for easy, low-cost outdoor installation.

YCAL0019EE40 15.45 2.96 18.33 4.3 36.96 1481 2789 1136 1171 Our YCAL Air-Cooled Chillers feature a single-point power connection for reduced wiring costs,
industry leading environmentally friendly design, high energy efficiency, and a light, small unit that
YCAL0022EE40 18.7 2.96 18.7 4.5 44.75 1597 2789 1136 1171 maximizes your usable space.

YCAL0028EE40 25.57 2.96 30.36 4.02 61.19 1835 2789 1136 1270 Features

1 Environmental 2 Reduced 3 More 4 Many


YCAL0033EE40 28.56 3.08 32.64 4.25 68.34 2077 2789 1136 1270 Building…
Responsibility Is Total Cost of Less Chiller Applications,
Notes:
Standard Ownership One Chiller
YCAL chillers are
• The above Chiller Selections are rated at AHRI conditions (95°F Ambient Temp. & 44/54°F Chilled Water Leaving/Entering Temp.
YORK® chillers, with Excellent energy lighter and smaller YCAL chillers
• Condenser is with advanced Microchannel design
zero-ODP HFC-410A efficiency, high than competitive offer a variety of
• All the above units are SASO compliant.
refrigerant and up to reliability, and units, which energy, sound,
50% less refrigerant easy maintenance minimizes your and mechanical
charge, make minimize your cost installation cost configurations to
you the leader in of ownership. and maximizes your suit your many
environmental design. usable space. application needs.

Sound Attenuation Options (Air Cooled Chillers)

Low-Sound Fans Compressor Blanket

In place of standard speed fan motors, lower-speed Fitted in two pieces around the compressor with
fan motors can be specified to minimize sounds caused Velcro seams for easy serviceability. Polyester material:
by air traveling through the condenser section coils. high tensile strength, both UV and mildew protected,
Regular motors and pitched fan blades can be replaced waterproof, rip-resistant and fire-resistant (meeting
with steeper pitched blades and matched lower RPM State of California Fire Marshall flame specifications).
motors to provide the required airflow volume. Easily cleanable with soap and water.
LOW SOUND FANS FACTORY- OR FIELD
MOUNTED OPTION
Screw Compressor Attenuation Condenser
Compressor
The aerodynamic neutral zone of the “W” section
Heavy-gauge, galvanizedsteel baffles are field installed of each fan cell is baffled by specially formulated,
around the lower half of the chiller and epoxy painted to inorganic-spun fiber that is inert and non-flame
match the unit’s color. The baffle design facilitates air flow propagating. (The same material is used in compressor
through the compressor section while blocking sound perimeter baffling.)
emissions and allowing easy removal for service access.

FACTORY-MOUNTED FACTORY-MOUNTED
OPTION OPTION

8
WATER-COOLED
CHILLERS
YORK® YVWA Screw Chillers - North America Origin

YVWA Variable-Speed, Water-Cooled, Screw Chillers: 125 - 300 TR (440 - 1,055 kW)
YORK® YVWA is designed to address four primary requirements – efficiency, application flexibility, sustainability, and
confidence. With infinite chiller configurations to help you achieve your goals, our YVWA chiller features the ability
to reduce compressor speed, which means increased energy savings and a reduced carbon footprint. Our YVWA
Water-Cooled Variable Speed Screw Chiller delivers superior energy performance at all operating hours. Enjoy the
flexibility and convenience of just one chiller for many applications.

Reduce compressor speed and increase efficiency as much as 30%


Strike the right balance between capital cost, ownership cost, and energy efficiency by tailoring and tuning
configurations.
Flexibility
The YVWA chiller is capable of handling the high pressures associated with ice thermal storage or heat pump
applications with the highest available efficiencies.
Smaller environmental footprint
Reduces the refrigerant charge up to 30% and utility emissions as much as 30%.
Feel confident with a proven performer
From inventing chiller VSD technology in 1979 to over 2,500,000 TR of VSD screw compressors operating today,
we back you with unrivaled technological experience and the world’s largest service organization.

10
YORK® YZ Centrifugal Chillers - North America Origin

YZ Water-Cooled Magnetic Bearing Centrifugal Chiller 150 - 1,425 TR (530 - 5,011 kW)
Advanced Technologies of the YORK® YZ Chiller The YORK® YZ chiller from the chiller experts is the industry’s
first chiller fully optimized for ultimate performance with a next
generation low-GWP refrigerant, offering exceptional efficiency and
operation.
Capacity Control Logic Magnetic Bearing Driveline
Patented YORK® control technology Offers outstanding reliability and 80%
fewer moving parts than traditional oil-or
From the Chiller Experts
provides rapid response to the load
on the building, ensuring the YZ does refrigerant-lubricated drivelines.
not waste energy or work harder than The YORK® YZ chiller is a revolutionary advancement that challenges everything about
needed. conventional chiller design. Built upon decades of industry-leading chiller expertise, our
engineers questioned every component, analyzed every function and challenged every
Optimized Compressor assumption.
Optimized, single-stage design enables
Variable-Speed Drive YORK® chillers to provide best
real-world energy efficiency and the Optimized for Ultimate Performance
The YZ, with VSD standard, as widest operating range at off-design
well as variable geometry diffuser conditions.
and magnetic bearing technology, The design premise for the YORK® YZ was simple: don’t just make a new chiller – make
delivers up to 35% annual the best chiller. This was accomplished through a holistic approach to system design and
energy savings versus traditional engineering, optimizing every component around a carefully selected next generation
fixed-speed oil bearing chillers. High-Speed refrigerant for ultimate performance.
Hermetic
Induction Motor
OptiViewTM Control The YZ will be the Dramatically Lower Cost of Ownership
first magnetic bearing
Panel with Connected centrifugal chiller to To maximize value, the YORK® YZ design has been optimized to minimize operating costs by
Services utilize reliable, robust, leveraging the benefits of a new refrigerant in our new heat exchangers and motor/compressor
and low-maintenance driveline while also mitigating the high cost of a next generation refrigerant.
Offers over 100 setpoints, induction motors.
readouts, alerts, trending reports
and more. Data can also be
securely connected to analytics
platform for remote monitoring and predictive diagnostics. Low-Pressure The New Definition of Sustainability
Chiller
True sustainability means the lowest total emissions – from beginning to end. Adapting a chiller
Building upon decades of design to a new refrigerant is not enough. That’s why the YORK® YZ was specifically designed
Falling Film Evaporator experience, the YZ has to maximize the potential energy efficiency of a low-GWP refrigerant. Our design optimization
been fully optimized
around R-1233zd, which for the highest possible efficiency, combined with a low-GWP refrigerant, makes the YORK®
Reduces refrigerant charge up to 60% and reduces evaporator shell size up to 20%
compared to other flooded, low-pressure refrigerant designs. has a GWP of 1. YZ Centrifugal Chiller the best choice for the environment.

11
YORK® YMC² Centrifugal Chillers - North America Origin

YMC² Centrifugal Magnetic Drive Chiller: 165 - 1000 TR (580 - 3,500 kW)

Reduce your energy consumption and increase efficiency with our YMC² Centrifugal Magnetic Drive Chiller
from YORK®.
Featuring state-of-the-art design and active magnetic bearing technology, this magnetic bearing chiller
addresses the most critical concerns of facility owners – energy, sustainability, sound, and uptime.
With a reduction in noise of about 50 percent when compared to competitors’ chillers, our YMC²
magnetic bearing chiller is an advanced solution that will keep you a step ahead of the game.

Smart Investment
Lower total cost of ownership over the life of the chiller due to reduced energy and maintenance costs.
Highly Efficient
Designed to achieve real-world energy operation by utilizing industry-leading low entering condenser water
temperatures, the YMC² can offer as low as 0.175 kW/TR at full capacity and below 0.1 kW/ton at part load.
Versatile
Offers the widest operating range to meet the needs of various applications.
Strongly Dependable
Permanent
Fully integrated YORK® chiller design provides reliable operation and lower maintenance. magnet motor
Very Low Sound Levels
Quieter than a household vacuum cleaner, the YMC² achieves sound levels as low as 70 dBA.

Active magnetic
bearings
(cartridges)

Proven aerodynamic design from


our flagship YK product line

12
YORK® YK Centrifugal Chillers - North America Origin

YK CENTRIFUGAL CHILLER - Innovation for Real-World Performance


250-3000 TR (880 - 10,550 kW)
YORK® created a centrifugal chiller that can handle your project’s unique variables. The YORK® YK
chiller delivers ultimate real-world performance thanks to an exclusive combination of benefits:

Lowest total cost of ownership Sustainable chiller design


Lower installation, operating, and maintenance costs with Refrigerant choice and flexibility for today and tomorrow with 30%
system design choices that pay off in less than 1 year. lower refrigerant charge.

Advanced innovations for unrivaled Proven experience in applications, service and


real-world performance support
To build a whole system that is greater than the sum From building the world’s first ice-making machine in 1885 to
of its parts, we engineered an unprecedented array introducing the first chiller-specific variable-speed drives in
of innovations into an integrated design that delivers 1979, YORK® chiller experience spans over 130 years and more
superior performance. Competitive chillers may use a few than 100 countries. By combining the highest level of application
of the same type of components, but only YORK® chillers engineering support, controls software programming expertise,
offer this level of innovation, including our own chiller- and mechanical system and building automation system support,
specific variable-speed drive. The result: efficiencies as our team has industry-leading resources to handle your unique
low as 0.20 kW/ton (17.6 COP) while running in weather challenges.
conditions other chillers can’t tolerate.

Centrifugal Chillers in Today’s Complex Buildings - Key Vertical Markets for Large Centrifugal Chillers
District Cooling – Central Utility Plant
Chilled Water
Plant Energy
Transfer Air
Station Handling
Units
Distribution Network

13
YORK® YD Centrifugal Chillers - North America Origin

YD Dual Centrifugal Chiller: 1,500 - 6,000 TR (5,300 - 21,100 kW)

Get the superior performance you want from a chiller that takes up less space with our YD Dual Unsurpassed Energy Savings
Centrifugal Chiller from YORK®. At Johnson Controls, we’ve designed the YD Dual Centrifugal Chiller to
With the OptiSpeed™ Drive, energy consumption can be as low as .20 kW/TR, reducing annual
feature compact configurations for real-world efficiency, energy savings through variable speed drive,
energy costs by as much as 30%.
environmental sustainability, and enhanced reliability though advanced controls.
Real-World Efficiency
A perfect fit for comfort, industrial, or process installations, this chiller utilizes two YORK® centrifugal
compressors operating in parallel and features the most compact configuration in its class. Designed for maximum efficiency in the real world, where 99% of the cooling season is spent at off–
design conditions. Save even more energy with the addition of the OptiSpeed-variable-speed drive.
Environmental Responsibility
HFC-134a refrigerant has zero ozone-depletion potential and low total global-warming potential.
Earn LEED® Points
Earn credits for Energy and Atmosphere (EAc1) and for Enhanced Refrigerant Management (EAc4).
Easy Operation – The OptiView™
Control Center ensures optimum performance and easy operation.

King Abdullah University of Resorts World Integrated Resort


The most compact Science and Technology Thuwal, in Sentosa, Singapore uses 5
configuration in its class Saudi Arabia uses 9 YORK® YD YORK® YD chillers in its 18,000
makes the YD chiller a (5000 Ton each) chillers in its Ton District Cooling Plant
perfect fit for comfort, Central Cooling Plant. Selected
industrial, or process by SAUDI ARAMCO for this
installations. project, due to its compact
configuration and high efficiency.

14
YORK® TITAN OM Centrifugal Chillers - North America Origin

TITAN OM Custom Design Centrifugal Chiller: 3,000 - 5,500 TR


(10,550 - 19,350 kW)
With unsurpassed reliability and a chiller design that has been proven in thousands of installations The World Leader
worldwide, our YORK® OM Custom-Design Centrifugal Chiller features extraordinary capacity through
In large-scale cooling projects, OM chillers are used more than all other brands combined.
advanced technology that is the end result of over 50 years of pioneering experience from Johnson
Controls. Extraordinary Capacity
Cooling engineering marvels like the tallest buildings in the world (and even the U.S. Capitol complex) Available in sizes double the size of the largest packaged chiller, OM chillers minimize space and
through custom chiller design, our water-cooled industrial chillers deliver all the flexibility and simplify operation.
custom capabilities you need, no matter what.
Unsurpassed Reliability
Industrial-grade construction enables OM chillers to operate 24/7 for decades.
Exceptional Flexibility
Available in electric-, steam-, or gas-drive, for water- or air-cooled condensing, OM chillers can be
used for water chilling, brine cooling, or ice building.

YORK® Titan OM chillers cool Al Masjid An Nabawi For over 40 years,


the Petronas Twin Towers is one of the world’s YORK® Titan chillers
in Kuala Lumpur, Malaysia. largest air-cooled chiller have cooled the United
Three 5,000 TR electric-drive installation. It requires States Capitol complex,
chillers and three 5,000 20,400 TR of cooling providing 30,600 TR
TR steam-turbine chillers which is accomplished to generate chilled
are used in this extensive with six Titan 3,400 TR water for this immense
project. chillers. district-cooling project.

15
YORK® Absorption Chillers

YORK® Absorption Chillers and Heat Pump


With innovative 2-step evaporation and absorption-cycle technology

DRIVING HEAT SOURCE MODEL AND DESCRIPTION DRIVING HEAT SOURCE MODEL AND DESCRIPTION

Single Effect Hot Water


Multi Energy
Model: YHAU-CL/CH
EXHAUST GAS AND LOW Model: YHAU-CE -J
HOT WATER Capacity: 105 - 6,153 kW / 30 - 1,750 TR
TEMPERATURE HOT WATER Capacity: 527 - 3,516 kW /150 - 1,000 TR
Application: Combined heat and power (CHP), commercial cooling,
Application: Combined heat and power (CHP)
industrial process cooling

Single Effect Steam Fired


Multi Energy
Model: YHAU-C EXHAUST GAS AND LOW
LOW Model: YHAU-CGE-J
Capacity: 422 - 5,275 kW / 120 - 1,500 TR TEMPERATURE HOT WATER
PRESSURE STEAM Capacity: Custom
Application: Combined heat and power (CHP), commercial cooling, AND DIRECT FIRED
Application: Combined heat and power (CHP), commercial cooling
industrial process cooling

Double Effect Steam Fired


Gas Gene-Link
Model: YHAU-CW
MEDIUM NATURAL GAS AND LOW Model: YHAU-CG-J
Capacity: 422 - 14,065 kW / 120 - 4,000 TR
PRESSURE STEAM TEMPERATURE HOT WATER Capacity: 422 - 4,395 kW / 120 - 1,250 TR
Application: Combined heat and power (CHP), commercial cooling,
Application: Combined heat and power (CHP), commercial cooling
industrial process cooling

Steam Gene-Link
Small Double Effect Natural Gas or Light Oil*
MEDIUM PRESSURE STEAM Model: YHAU-CW-J
Model: YHAU-F
DIRECT FIRED AND LOW TEMPERATURE Capacity: 422 - 14,065 kW / 120 - 4,000 TR
Capacity: 105 - 352 kW / 30 - 100 TR
HOT WATER Application: Combined heat and power (CHP), industrial process
Application: Commercial cooling
cooling

Large Double Effect Natural Gas or Light Oil Double Effect Low Temperature (-5°C)
MEDIUM PRESSURE STEAM,
Model: YHAU-CG Model: YHAU-C-L
DIRECT FIRED DIRECT FIRED, HIGH
Capacity: 422 - 4,395 kW / 120 - 1,250 TR Capacity: 176 - 1,758 kW / 50 - 500 TR
TEMPERATURE HOT WATER
Application: Commercial cooling, industrial process cooling Application: Industrial process cooling (food & beverage)

Double Effect Direct Exhaust Gas Single Effect Absorption Heat Pump (Up to 95°C)
LOW PRESSURE STEAM,
Model: YHAU-CE Model: YHAP-C
EXHAUST GAS MEDIUM PRESSURE STEAM,
Capacity: 527 - 3,516 kW /150 - 1,000 TR Capacity: 900 - 40,000 kW
DIRECT FIRED
Application: Combined heat and power (CHP) Application: District heating, industrial process heating

*Utilizes standard cycle

16
AIR HANDLING
UNITS
YMA-070 7000 1570 x 2700 x 3450 1387 500 15 113.6 99.8 24.4 / 17.2 13

YMA-080 8000 1770 x 2700 x 3650 1478 500 15 130.2 114.0 24.4 / 17.2 13

YMA-090 9000 2010 x 2650 x 3800 1677 500 15 146.6 128.4 24.4 / 17.2 13

Air Handling Units YMA-100

YMA-110
10000

11000
2050 x 2800 x 3950

2090 x 3000 x 4200


1867

2102
500

500
18.5

18.5
162.4

178.0
142.6

156.9
24.4 / 17.2

24.4 / 17.2
13

13

YMA-120 12000 2010 x 3350 x 4150 2192 500 18.5 194.9 171.2 24.4 / 17.2 13
UNIT MODEL / GENERAL FAN COOLING COIL
YMA-130 13000 2090 x 3550 x 4200 2251 500 22 211.6 185.4 24.4 / 17.2 13
Water
Supply Air Motor Total Sensible Entering Air Leaving Air Water
Height x Width x Depth Weight ESP YMA-140 14000 2090 x Pressure
3900 x 4200 2467 500 22 226.9 199.7 24.4 / 17.2 13
Model Name flow Power Capacity Capacity Temp Temp Flow
Drop
YMA-150 15000 2090 x 4550 x 4200 2827 500 30 244.8 213.9 24.4 / 17.2 13

YORK YMA Custom Air Handling Units - Saudi Origin


®
YMA-010
L/s
1000
mm
810 x 1200 x 2600
kg
397
Pa
500
kW
2.2
kW
16.2
kW
14.3
DB/WB (°C) DB/WB (°C)
YMA-160
24.4 / 17.2
16000
13 / 12.3
L/s
0.43
kPa
2210 x 4350 x 4350
45
2930 500 30 260.4 228.2 24.4 / 17.2 13

YMA-170 17000 2210 x 4600 x 4350 3018 500 30 277.2 242.4 24.4 / 17.2 13
YMA-020 2000 1090 x 1500 x 2800 566 500 4 32.5 28.5 24.4 / 17.2 13 / 12.3 0.86 42
YMA-180 18000 2170 x 4900 x 4000 3143 500 15 x 2 294.1 256.7 24.4 / 17.2 13
YMA-030 3000 1410 x 1600 x 2800 692 500 5.5 48.8 42.8 24.4 YMA-190
/ 17.2 13 / 12.3
19000 1.30 42x 4000
2170 x 5500 3401 500 15 x 2 309.4 271.0 24.4 / 17.2 13
YMA-040 4000 1450 x 2000 x 2900 848 500 7.5 65.0 57.0 24.4 YMA-200
/ 17.2 13 / 12.3
20000 1.72 30x 4000
2170 x 5800 3555 500 15 x 2 326.4 285.2 24.4 / 17.2 13

YMA-050 5000 1410 x 2300 x 3300 1105 500 11 81.0 71.3 24.4 / 17.2 13 / 12.4 2.15 36
UNIT MODEL / GENERAL FAN COOLING COIL AHU's sections include air mixing box + pre-filter G3 + bag filter F7 + cooling coil + centrifugal belt driven fan.
YMA-060 6000 1410 x 2650 x 3300 1206 500 11 97.7 85.6 Maximum
24.4 / 17.2 coil 13
face/ velocity
12.3 is 2.52.59
m/s. 55
Chilled water in/out temperature 5.5°C / 14.5°C.
Supply Air YMA-070Total 7000Sensible
Motor 1570 x Entering
2700 x 3450 Air 1387
Leaving 500 Water
Air 15 113.6Pressure
Water 99.8 24.4 / 17.2
Height 13above
indicated / 12.4doesn’t 3.02 42 frame 100mm.
include the base
Height x Width x Depth Weight ESP Power supply 400V/3Ph/50Hz.
Flow Power Capacity
YMA-080 8000Capacity
1770 x 2700Temp
x 3650 1478Temp 500 Flow
15 Drop
130.2 114.0 24.4 / 17.2 13 / 12.3 3.46 59
Model Name
Model 13
Box Mechanical
3.89characteristics (EN1886)
L/s mm kg Pa kW YMA-090kW 9000
kW 2010 x 2650
DB/WBx 3800
(°C) 1677 500
DB/WB (°C) L/s15 146.6
kPa 128.4 24.4 / 17.2 / 12.3 56

YMA-100 10000 2050 x 2800 x 3950 1867 500 18.5 162.4 142.6
Casing 13Casing
24.4 / 17.2 / 12.3
air 4.31 45
Thermal
Thermal transmitt.
YMA-010 1000 810 x 1200 x 2600 397 500 2.2 16.2 14.3 24.4 / 17.2 13 / 12.3 0.43 45 strength leakage bridging
YMA-110 11000 2090 x 3000 x 4200 2102 500 18.5 178.0 156.9 24.4 / 17.2
2A 13 / 12.4
B 4.72 T230 TB2
YMA-020 2000 1090 x 1500 x 2800 566 500 4 YMA-12032.5 12000 28.5 2010 x 3350
24.4 / 17.2
x 4150 13 / 12.3 500
2192 0.86
18.5 194.942 171.2 24.4 / 17.2 13 / 12.4 5.17 42

YMA-130 13000 2090 x 3550 x 4200 2251 500 22 211.6 185.4 24.4 / 17.2 13 / 12.3 5.62 47
YMA-030 3000 1410 x 1600 x 2800 692 500 5.5 48.8 42.8 24.4 / 17.2 13 / 12.3 1.30 42 Air Handling Units
YMA-140 14000 2090 x 3900 x 4200 2467 500 22 226.9 199.7 24.4 / 17.2 13 / 12.4 6.02 27
UNIT MODEL / GENERAL FAN COOLING COIL
YMA-040 4000 1450 x 2000 x 2900 848 500 7.5 65.0 57.0 24.4 / 17.2 13 / 12.3 1.72 30 Water
YMA-150 15000 2090 x 4550 x 4200 2827 500 30 244.8 Supply Air213.9 24.4 / 17.2
Height x Width x Depth
13 / 12.3
Weight ESP
6.50 Total
Motor 34
Sensible Entering Air Leaving Air Water
Pressure
Model Name flow Power Capacity Capacity Temp Temp Flow
Drop
YMA-050 5000 1410 x 2300 x 3300 1105 500 11 YMA-16081.0 16000 71.3 2210 x 4350
24.4 / 17.2
x 4350 13 / 12.4 500
2930 2.1530 260.436 L/s 228.2 24.4
mm / 17.2 kg13 / 12.3
Pa 6.91
kW kW 33kW DB/WB (°C) DB/WB (°C) L/s kPa
YMA-010 1000 810 x 1200 x 2600 397 500 2.2 16.2 14.3 24.4 / 17.2 13 / 12.3 0.43 45
YMA-170 17000 2210 x 4600 x 4350 3018 500 30 277.2 242.4 24.4 / 17.2 13 / 12.3 7.36 38
YMA-060 6000 1410 x 2650 x 3300 1206 500 11 97.7 85.6 24.4 / 17.2 13 / 12.3 2.59 YMA-020 552000 1090 x 1500 x 2800 566 500 4 32.5 28.5 24.4 / 17.2 13 / 12.3 0.86 42

YMA-180 18000 2170 x 4900 x 4000 3143 500 15 x 2 294.1


YMA-030 3000 256.71410 x 1600
24.4x 2800
/ 17.2 13
692 / 12.3
500 7.81
5.5 48.8 4842.8 24.4 / 17.2 13 / 12.3 1.30 42

YMA-070 7000 1570 x 2700 x 3450 1387 500 15 113.6 99.8 24.4 / 17.2 13 / 12.4 3.02 YMA-040 424000 1450 x 2000 x 2900 848 500 7.5 65.0 57.0 24.4 / 17.2 13 / 12.3 1.72 30
YMA-190 19000 2170 x 5500 x 4000 3401 500 15 x 2 YMA-050
309.4 5000
271.01410 x 2300
24.4x 3300
/ 17.2 1105
13 / 12.3
500
8.22
11 81.0
3871.3 24.4 / 17.2 13 / 12.4 2.15 36

YMA-080 8000 1770 x 2700 x 3650 1478 500 15 YMA-200130.2 20000 114.0 2170 x 5800
24.4 / 17.2
x 4000 13 / 12.3 500
3555 3.46
15 x 2 326.4
YMA-060
596000 285.21410 x 2650
24.4x 3300
/ 17.2 13
1206 / 12.3
500 8.66
11 97.7 4385.6 24.4 / 17.2 13 / 12.3 2.59 55

YMA-070 7000 1570 x 2700 x 3450 1387 500 15 113.6 99.8 24.4 / 17.2 13 / 12.4 3.02 42

YMA-080 8000 1770 x 2700 x 3650 1478 500 15 130.2 114.0 24.4 / 17.2 13 / 12.3 3.46 59
YMA-090 9000 2010 x 2650 x 3800 1677 500 15 146.6
AHU's sections 128.4box + pre-filter
include air mixing 24.4G3/ 17.2
+ bag filter F713 / 12.3coil + centrifugal
+ cooling 3.89 belt driven 56
fan.
YMA-090 9000 2010 x 2650 x 3800 1677 500 15 146.6 128.4 24.4 / 17.2 13 / 12.3 3.89 56
Maximum coil face velocity is 2.5 m/s. • AHU’s sections include air mixing box + pre-filter G3 + bag filter F7 +
YMA-100 10000 2050 x 2800 x 3950 1867 500 18.5 162.4 142.6 24.4 / 17.2 13 / 12.3 4.31 45
YMA-100 10000 2050 x 2800 x 3950 1867 500 18.5 162.4
Chilled water 142.65.5°C / 14.5°C.
in/out temperature 24.4 / 17.2 13 / 12.3 4.31 45 cooling coil + centrifugal belt driven fan.
YMA-110 11000 2090 x 3000 x 4200 2102 500 18.5 178.0 156.9 24.4 / 17.2 13 / 12.4 4.72 30
Height indicated above doesn’t include the base frame 100mm.
YMA-120 12000 • Maximum
2010 x 3350 x 4150 2192 coil
500 face
18.5 velocity
194.9 is171.2
2.5 m/s.
24.4 / 17.2 13 / 12.4 5.17 42
YMA-110 11000 2090 x 3000 x 4200 2102 500 Power supply
18.5 400V/3Ph/50Hz.
178.0 156.9 24.4 / 17.2 13 / 12.4 4.72 30
YMA-130 13000 2090 x 3550 x 4200 2251 500 22 211.6 185.4 24.4 / 17.2 13 / 12.3 5.62 47
• Chilled water in/out temperature 5.5°C / 14.5°C.
YMA-140 14000 2090 x 3900 x 4200 2467 500 22 226.9 199.7 24.4 / 17.2 13 / 12.4 6.02 27
YMA-120 12000 2010 x 3350 x 4150 2192 500 18.5 Model
194.9 171.2 characteristics
Box Mechanical 24.4 / 17.2
(EN1886)13 / 12.4 5.17 YMA-150
4215000 • Height
2090 x 4550 x 4200 2827 indicated
500 above
30 doesn’t
244.8 213.9 include
24.4 / 17.2 the
13 /base
12.3 frame
6.50 100mm.
34

22 Casing211.6Casing air Thermal YMA-160 16000 • Power


2210 x 4350 x 4350 2930 supply
500 380V/3Ph/60Hz.
30 260.4 228.2 24.4 / 17.2 13 / 12.3 6.91 33
YMA-130 13000 2090 x 3550 x 4200 2251 500 185.4 24.4 / 17.2
Thermal transmitt. 13 / 12.3 5.62 YMA-170
4717000 2210 x 4600 x 4350 3018 500 30 277.2 242.4 24.4 / 17.2 13 / 12.3 7.36 38
strength leakage bridging YMA-180 18000 2170 x 4900 x 4000 3143 500 15 x 2 294.1 256.7 24.4 / 17.2 13 / 12.3 7.81 48
YMA-140 14000 2090 x 3900 x 4200 2467 500 22 2A 226.9 B 199.7 T2
24.4 / 17.2 TB2
13 / 12.4 6.02 YMA-190 2719000 2170 x 5500 x 4000 3401 Model
500 Box
15 x Mechanical
2 309.4 271.0 characteristics
24.4 / 17.2 13 / 12.3 (EN1886)
8.22 38

YMA-200 20000 2170 x 5800 x 4000 3555 500 15 x 2 326.4 285.2 24.4 / 17.2 13 / 12.3 8.66 43
YMA-150 15000 2090 x 4550 x 4200 2827 500 30 244.8 213.9 24.4 / 17.2 13 / 12.3 6.50 34 Casing strength Casing air leakage Thermal transmitt. Thermal bridging
AHU's sections include air mixing box + pre-filter G3 + bag filter F7 + cooling coil + centrifugal belt driven fan.
Maximum coil face velocity is 2.5 m/s.
Chilled water in/out temperature 5.5°C / 14.5°C.
2A B T2 TB2
YMA-160 16000 2210 x 4350 x 4350 2930 500 30 260.4 228.2 24.4 / 17.2 13 / 12.3 6.91 33
Height indicated above doesn’t include the base frame 100mm.
Power supply 400V/3Ph/50Hz.

YMA-170 17000 2210 x 4600 x 4350 3018 500 30 277.2 242.4 24.4 / 17.2 13 / 12.3 7.36 38
Model Box Mechanical characteristics (EN1886)
Casing Casing air Thermal
Thermal transmitt.
YMA-180 18000 2170 x 4900 x 4000 3143 500 15 x 2 294.1 256.7 24.4 / 17.2 13 / 12.3 7.81 strength 48
leakage bridging
2A B T2 TB2

YMA-190 19000 2170 x 5500 x 4000 3401 500 15 x 2 309.4 271.0 24.4 / 17.2 13 / 12.3 8.22 38

YMA-200 20000 2170 x 5800 x 4000 3555 500 15 x 2 326.4 285.2 24.4 / 17.2 13 / 12.3 8.66 43

Optional

18
YORK® Air Handling Units - Market-Leading Features with Patented Designs
Full Customized Solution
• Dimensional Flexibility: Space constraints are a
reality on most construction projects. Customized
Thermal Bridge YMA design is based on variable aspect ratios, so the
unit can be specified to fit the application and space.
Patented structure of thermal bridge free design is
applied in YMA series. Aluminum, reinforced plastic Digital Direct Control - DDC Panels • Material Flexibility: Different environments
triaxial angle lug and specially designed door make
require different materials so we offer a number of
heat insulation more efficient and appearance more • Factory assembled control panel.
construction materials, including galvanized steel,
aesthetic, and thermal bridge factor can meet EN1886 • Single responsibility of quality.
High Quality Casing pre-coated steel, stainless steel, and aluminum.
class TB2. • Simplified commissioning & handling over stage.
Standard of 60 mm double skinned with pre- • Reduce job site time & labor cost.
• Component Flexibility: Our units offer every
plasticized coated steel & galvanized panels available air-handling component. And as applicable
with various options internal and external skins, technology creates new capabilities, Al Salem
density pressure of 40kg/m3 injected polymerized Johnson Controls will apply this to our product range.
polyurethane foam (B3) insulation will supply
rigidity to the AHU’s casing. Optional panels can
be manufactured from pre-painted Stainless steel
304/316.

Efficient Fans and Motors


• IE3 motors: High-Quality motor with high
efficiency from well-known brand that use
less energy and run cooler. Motor is IP55
protection class, with classes F & H insulation
options. It can run reliably and efficiently.

• Compatible with VFD: it can reduce the


energy consumption and the operating cost of
the system.
IAQ Solutions
Providing a complete range of advanced filtration, proper humidification & ultravio-
let air purifiers, airborne contaminants are reduced to help in achieving an optimum
room temperature, humidity and work toward providing a cleaner and healthier
Indoor Air Quality (IAQ). High Efficient Heat Exchangers
Cooling and heating coil are made of mechanically expanded
copper tubes with aluminum fins as standard, providing
reliable performance certified by AHRI 410.

Heat Recovery System (Options):


• Heat wheel
• Plate Heat Exchanger
• Heat pipe solution

19
Fresh Air Handling Units
HEAT RECOVERY WHEE
UNIT MODEL / GENERAL SUPPLY FAN EXTRACT FAN
Extract Side Sup

Supply Air Extract Air Motor Motor Air On Air Off Air On
Height x Width x Depth Weight ESP ESP
Model Name flow flow Power Power DB/WB DB/WB DB/WB

L/s L/s mm kg Pa kW Pa kW (°C) (°C) (°C)


YMA-010 1000 900 1620 x 1200 x 3300 1028 500 3 500 1.5 24 / 17.1 38 / 25.3 46 / 29
YMA-020 2000 1800 2140 x 1550 x 3500 1441 500 5.5 500 3 24 / 17.1 37.6 / 25.1 46 / 29

YORK YMA Custom Fresh Air Handling Units with Heat Recovery
®
Wheel
Air Handling - Saudi Origin
Units
YMA-030
YMA-040
YMA-050
3000
4000
5000
2700
3600
4500
2180 x 1950 x 3700
2540 x 2000 x 3800
2900 x 2050 x 4000
1832
2105
2401
500
500
500
7.5
7.5
11
500
500
500
4
5.5
7.5
24 / 17.1
24 / 17.1
24 / 17.1
37.2 / 24.9
37.7 / 25.2
36.5 / 24.6
46 / 29
46 / 29
46 / 29
YMA-060 6000 5400 2940 x 2400 x 4400 2879 500 11 500 7.5 24 / 17.1 37.3 / 24.9 46 / 29

UNIT MODEL / GENERAL FAN COOLINGYMA-070


COIL 7000 6300 3140 x 2600 x 4500 3540 500 15 500 11 24 / 17.1 37.4 / 22.7 46 / 29
YMA-080 8000 7200 3340 x 2700 x 4600 3832 500 15 500 11 24 / 17.1 36.7 / 24.6 46 / 29
Water3460 x 2850 x 4800
Supply Air Motor Total Sensible Entering Air Leaving
YMA-090 Air 9000Water 8100 4146 500 18.5 500 15 24 / 17.1 37.1 / 24.9 46 / 29
Height x Width x Depth Weight ESP Pressure
Model Name flow Power Capacity Capacity Temp Temp
YMA-100 10000 Flow 9000 3620 x 3000 x 5000 4599 500 18.5 500 15 24 / 17.1 37.4 / 25 46 / 29

EXTRACT HEAT RECOVERY WHEEL YMA-110 11000 9900 Drop 3780 x 3100 x 5100 4836 500 22 500 15 24 / 17.1 36.9 / 24.8 46 / 29
UNIT MODEL / GENERAL SUPPLY FAN L/s mm COOLING
kg PaCOIL kW kW kW DB/WB (°C) DB/WB
YMA-120 (°C) 12000 L/s 10800 kPa 3860 x 3300 x 5150 5132 500 22 500 15 24 / 17.1 37.2 / 24.9 46 / 29
FAN Extract Side Supply Side YMA-130 13000 11700 3860 x 3550 x 5350 5771 500 30 500 15 24 / 17.1 37.5 / 25 46 / 29
YMA-010 1000 810 x 1200 x 2600 397 500 2.2 16.2 14.3 24.4 / 17.2 13 / 12.3
YMA-140 14000
0.43 12600
45 3940 x 3700 x 5400 6039 500 30 500 18.5 24 / 17.1 37.8 / 25.2 46 / 29
YMA-150 15000 13500 3980 x 3900 x 5550 6408 500 30 500 18.5 24 / 17.1 38 / 25.3 46 / 29
Supply Extract YMA-020 2000 1090 x 1500 x 2800 566 500Leaving
4 32.5 Water
28.5 24.4 / 17.2 13 / 12.3 0.86 42
Height x Width x Motor Motor Air On Air Off DB/ Air On Air Off DB/ Total Sensible Entering Water
Air Air Weight ESP ESP YMA-030 3000 1410 x 1600 x 2800 692 500 Air 5.5 48.8Pressure
42.8 24.4 / 17.2
Supply sections include pre-filter G3 + bag filter F7 + heat recovery wheel + cooling coil + centrifugal belt driven fan.
13 / 12.3 1.30 42
Model Depth Power Power DB/WB WB DB/WB WB Capacity Capacity Air Temp Flow Extract sections include pre-filter G3 + heat recovery wheel + centrifugal belt driven fan.
flow flow YMA-040 4000 1450 x 2000 x 2900 848 500 Temp7.5 65.0 Drop
57.0 24.4 / 17.2
Maximum coil face velocity is 2.5 m/s.
13water
/ 12.3 1.72 5.5°C / 14.5°C.30
Name Chilled in/out temperature
Height indicated above doesn’t include the base frame 100mm.
YMA-050 5000 1410 x 2300 x 3300 DB/WB DB/WB
1105 500 11 81.0 71.3 24.4 / 17.2 Power13supply
/ 12.4 2.15
400V/3Ph/50Hz. 36
L/s L/s mm kg Pa kW Pa kW (°C) (°C) (°C) (°C) kW kW L/s kPa
YMA-060 6000 1410 x 2650 x 3300 (°C) 500 (°C) 11
1206 97.7 85.6 24.4 / 17.2 13 / 12.3
Model 2.59 characteristics
Box Mechanical 55 (EN1886)
Casing Casing air Thermal
YMA-070 7000 1570 x 2700 x 3450 1387 500 15 113.6 99.8 24.4 / 17.2 13 / 12.4 leakage3.02transmitt.42 Thermal bridging
YMA-010 1000 900 1620 x 1200 x 3300 1028 500 3 500 1.5 24 / 17.1 38 / 25.3 46 / 29 33.6 / 23 38.0 25.9 33.6 / 23 13 / 12.8 1.01 48 strength
2A B T2 TB2
YMA-080 8000 1770 x 2700 x 3650 1478 500 15 130.2 114.0 24.4 / 17.2 13 / 12.3 3.46 59

YMA-090 9000 2010 x 2650 x 3800 1677 500 15 146.6 128.4 24.4 / 17.2 13 / 12.3 3.89 56
YMA-020 2000 1800 2140 x 1550 x 3500 1441 500 5.5 500 3 24 / 17.1 37.6 / 25.1 46 / 29 33.9 / 23.2 78.0 52.4 33.9 / 23.2 13 / 12.8 2.07 56
YMA-100 10000 2050 x 2800 x 3950 1867 500 18.5 162.4 142.6 24.4 / 17.2 13 / 12.3 4.31 45

YMA-110 11000 2090 x 3000 x 4200 2102 500 18.5 178.0 156.9 24.4 / 17.2 13 / 12.4 4.72 30
YMA-030 3000 2700 2180 x 1950 x 3700 1832 500 7.5 500 4 24 / 17.1 37.2 / 24.9 46 / 29 34.3 / 23.4 121.3 80.2 34.3 / 23.4 13 / 12.9 3.22 38
YMA-120 12000 2010 x 3350 x 4150 2192 500 18.5 194.9 171.2 24.4 / 17.2 13 / 12.4 5.17 42

YMA-130 13000 2090 x 3550 x 4200 2251 500 22 211.6 185.4 24.4 / 17.2 13 / 12.3 5.62 47
YMA-040 4000 3600 2540 x 2000 x 3800 2105 500 7.5 500 5.5 24 / 17.1 37.7 / 25.2 46 / 29 33.9 / 23.2 156.0 104.9 33.9 / 23.2 13 / 12.8 4.14 52 Air Handling Units
YMA-140 14000 2090 x 3900 x 4200 2467 500 22 226.9 199.7 24.4 / 17.2 13 / 12.4 6.02 27
UNIT MODEL / GENERAL FAN COOLING COIL
Water
YMA-150 15000 2090 x 4550 x 4200 2827 500 30 244.8 Supply213.9
Air 24.4 / 17.2
Height x Width x Depth
13 / 12.3ESP
Weight
6.50
Motor Total 34Sensible Entering Air Leaving Air Water
Pressure
YMA-050 5000 4500 2900 x 2050 x 4000 2401 500 11 500 7.5 24 / 17.1 36.5 / 24.6 46 / 29 34.8 / 23.7 205.6 136.8 34.8 / 23.7 13 / 12.9 5.46
Model Name 50
flow Power Capacity Capacity Temp Temp Flow
Drop
YMA-160 16000 2210 x 4350 x 4350 2930 500 30 260.4 L/s228.2 24.4
mm / 17.2 13
kg / 12.3Pa 6.91
kW kW 33 kW DB/WB (°C) DB/WB (°C) L/s kPa
YMA-010 1000 810 x 1200 x 2600 397 500 2.2 16.2 14.3 24.4 / 17.2 13 / 12.3 0.43 45
YMA-170 17000 2210 x 4600 x 4350 3018 500 30 277.2 242.4 24.4 / 17.2 13 / 12.3 7.36 38
YMA-060 6000 5400 2940 x 2400 x 4400 2879 500 11 500 7.5 24 / 17.1 37.3 / 24.9 46 / 29 34.2 / 23.3 240.0 159.7 34.2 / 23.3 13 / 12.9 6.37
YMA-020
41
2000 1090 x 1500 x 2800 566 500 4 32.5 28.5 24.4 / 17.2 13 / 12.3 0.86 42

YMA-180 18000 2170 x 4900 x 4000 3143 500 15 x 2 294.1


YMA-030 3000256.7 1410 24.4
x 1600 x/2800
17.2 13
692 / 12.3500 7.81
5.5 48.8 48 42.8 24.4 / 17.2 13 / 12.3 1.30 42

YMA-040 4000 1450 x 2000 x 2900 848 500 7.5 65.0 57.0 24.4 / 17.2 13 / 12.3 1.72 30
YMA-190 19000 2170 x 5500 x 4000 3401 500 15 x 2 309.4
YMA-050 5000
271.0 24.4 / 17.2
1410 x 2300 x 3300 1105
13 / 12.3500 8.22
11 81.0
38 71.3 24.4 / 17.2 13 / 12.4 2.15 36
YMA-070 7000 6300 3140 x 2600 x 4500 3540 500 15 500 11 24 / 17.1 37.4 / 22.7 46 / 29 34.1 / 23.3 277.8 185.4 34.1 / 23.3 13 / 12.9 7.37 53
YMA-200 20000 2170 x 5800 x 4000 3555 500 15 x 2 326.4
YMA-060 6000285.2 1410 24.4
x 2650 x/3300
17.2 13 /
1206 12.3500 8.66
11 97.7 43 85.6 24.4 / 17.2 13 / 12.3 2.59 55

YMA-070 7000 • Supply


1570 x 2700 x 3450 1387 sections
500 include
15 113.6 pre-filter
99.8 G3 +
24.4 / 17.2 13 / bag
12.4 filter
3.02 F742 + heat recovery

YMA-080 8000 1770 x 2700 x 3650wheel


1478+ cooling
500 coil +
15 130.2centrifugal
114.0 belt13 driven
24.4 / 17.2 / 12.3 fan. 59
3.46
YMA-080 8000 7200 3340 x 2700 x 4600 3832 500 15 500 11 24 / 17.1 36.7 / 24.6 AHU's
46 /sections
29 include
34.6 /air23.5
mixing box + pre-filter G3
322.8 + bag filter34.6
216.9 F7 + cooling
/ 23.5coil13
+ centrifugal
/ 12.9 belt driven fan. 27
8.57
YMA-090 9000 2010 x 2650 x 3800 1677 500 15 146.6 128.4 24.4 / 17.2 13 / 12.3 3.89 56
Maximum coil face velocity is 2.5 m/s. • Extract
YMA-100 10000 2050 x 2800 x 3950 1867 sections
500 include
18.5 162.4 pre-filter
142.6 G3 13+/ 12.3
24.4 / 17.2 heat4.31recovery
45 wheel +
Chilled water in/out temperature 5.5°C / 14.5°C.
YMA-110 11000 2090 x 3000 x 4200centrifugal
2102 belt 18.5
500 driven178.0fan.156.9
Maximum
24.4 / 17.2 coil
13 / 12.4 face
4.72 velocity
30 is 2.5 m/s.
Height indicated above doesn’t include the base frame 100mm.
YMA-090 9000 8100 3460 x 2850 x 4800 4146 500 18.5 500 15 24 / 17.1 37.1 / 24.9 46 / 29 34.4 / 23.5 366.3 241.8 34.4 / 23.5 13 / 12.9 9.72 YMA-120 34
12000 2010 x 3350 x 4150 2192 500 18.5 194.9 171.2 24.4 / 17.2 13 / 12.4 5.17 42
Power supply 400V/3Ph/50Hz. • Chilled water in/out temperature 5.5°C13 //12.314.5°C.
YMA-130 13000 2090 x 3550 x 4200 2251 500 22 211.6 185.4 24.4 / 17.2 5.62 47

YMA-140 14000 • Height


2090 x 3900 x 42002467 indicated
500 22above
226.9 doesn’t
199.7 include
24.4 / 17.2 the base
13 / 12.4 6.02 frame
27 100mm
YMA-100 10000 9000 3620 x 3000 x 5000 4599 500 18.5 500 15 24 / 17.1 37.4 / 25 46 Model
/ 29 Box
34.1Mechanical
/ 23.3 characteristics
396.4 264.8 (EN1886)
34.1 / 23.3 13 / 12.9 10.52
YMA-150 37
15000 2090 x 4550 x 4200 2827 500 30 244.8 213.9 24.4 / 17.2 13 / 12.3 6.50 34
• Power
2930 supply
500 380V/3Ph/60Hz.
Casing Casing air Thermal YMA-160 16000 2210 x 4350 x 4350 30 260.4 228.2 24.4 / 17.2 13 / 12.3 6.91 33

Thermal transmitt. YMA-170 17000 2210 x 4600 x 4350 3018 500 30 277.2 242.4 24.4 / 17.2 13 / 12.3 7.36 38
strength leakage bridging
YMA-110 11000 9900 3780 x 3100 x 5100 4836 500 22 500 15 24 / 17.1 36.9 / 24.8 46 / 29 34.5 / 23.5 440.4 296.8 34.5 / 23.5 13 / 12.9 11.69
YMA-180 41
18000 2170 x 4900 x 4000 3143
Model
500 15 x 2
Box Mechanical
294.1 256.7
characteristics
24.4 / 17.2
(EN1886)
13 / 12.3 7.81 48
2A B T2 TB2 YMA-190 19000 2170 x 5500 x 4000 3401 500 15 x 2 309.4 271.0 24.4 / 17.2 13 / 12.3 8.22 38

YMA-200 20000 2170 x 5800 x 4000 3555 500 15 x 2 326.4 285.2 24.4 / 17.2 13 / 12.3 8.66 43
Casing strength Casing air leakage Thermal transmitt. Thermal bridging
YMA-120 12000 10800 3860 x 3300 x 5150 5132 500 22 500 15 24 / 17.1 37.2 / 24.9 46 / 29 34.2 / 23.3 480.4 319.3 34.2 / 23.3 13 / 12.9 12.75
AHU's sections include48
air mixing box + pre-filter G3 + bag filter F7 + cooling coil + centrifugal belt driven fan.
Maximum coil face velocity is 2.5 m/s.
Chilled water in/out temperature 5.5°C / 14.5°C. 2A B T2 TB2
Height indicated above doesn’t include the base frame 100mm.
Power supply 400V/3Ph/50Hz.
YMA-130 13000 11700 3860 x 3550 x 5350 5771 500 30 500 15 24 / 17.1 37.5 / 25 46 / 29 34 / 23.2 509.8 342.7 34 / 23.2 13 / 12.9 13.53 21
Model Box Mechanical characteristics (EN1886)
Casing Casing air Thermal
Thermal transmitt.
strength leakage bridging
YMA-140 14000 12600 3940 x 3700 x 5400 6039 500 30 500 18.5 24 / 17.1 37.8 / 25.2 46 / 29 33.8 / 23.1 539.3 365.5 33.8 / 23.1 13 / 12.9 14.31
2A
23
B T2 TB2

YMA-150 15000 13500 3980 x 3900 x 5550 6408 500 30 500 18.5 24 / 17.1 38 / 25.3 46 / 29 33.6 / 23 567.5 387.7 33.6 / 23 13 / 12.9 15.06 26

Optional

20
YORK® YSM Modular Air Handling Units - Saudi Origin

UNIT MODEL / GENERAL FAN COOLING COIL

Supply Air Motor Total Sensible Entering Air Leaving Air Water Water
Height x Width x Depth Weight ESP
Model Name Flow Power Capacity Capacity Temp Temp Flow Pressure Drop
L/S mm kg Pa kW kW kW DB / WB (°C) DB / WB (°C) L/S kPa
YSM50M-0713-S-L 1416 861 x 1331 x 2566 586 500 3 33.6 24.48 27 / 19.5 12.89 / 12.57 1.32 6.2
YSM50M-0915-S-L 2124 1051 x 1521 x 2661 735 500 4 51.27 36.82 27 / 19.5 12.89 / 12.46 2.04 9.3
YSM50M-0917-S-L 2596 1051 x 1711 x 2756 851 500 5.5 58.63 43.72 27 / 19.5 13.28 / 12.96 2.32 4.3
YSM50M-1117-S-L 3067 1241 x 1711 x 2851 971 500 5.5 70.37 52.21 27 / 19.5 13.12 / 12.84 2.79 4.4
YSM50M-1317-S-L 3539 1431 x 1711 x 2851 1079 500 7.5 81.57 60.47 27 / 19.5 13.06 / 12.79 3.23 4.5
Plate filter Motor
YSM50M-1120-S-L 4011 1241 x 1996 x 2851 1106 500 7.5 98.86 70.84 27 / 19.5 12.62 / 12.28 3.94 9.2
YSM50M-1320-S-L 4483 1431 x 1996 x 2851 1188 500 7.5 103.7 75.91 27 / 19.5 13.23 / 12.79 4.1 7.7 • Polyester synthetic fiber filter • Well-known brand
YSM50M-1321-S-L 4955 1431 x 2091 x 3042 1384 500 11 115.7 84.01 27 / 19.5 13.16 / 12.69 4.6 9.9 media (YORK Qualified/ABB/Siemens)
YSM50M-1322-S-L 5427 1431 x 2186 x 3042 1435 500 11 128.0 92.44 27 / 19.5 13.12 / 12.63 5.1 12.4 • Thickness of 46mm • TEFC, IP55 protection class and
YSM50M-1523-S-L 6135 1621 x 2281 x 3042 1627 500 11 150.4 107.22 27 / 19.5 12.77 / 12.32 5.94 14 Class F insulation
• Filtering efficiency:
YSM50M-1722-S-L 6607 1811 x 2186 x 3042 1692 500 15 159.6 114.59 27 / 19.5 12.89 / 12.45 6.3 13 G3/G4/F5 (G1 filter use AI mesh) • Constant-speed motors and
VSD motors are available
YSM50M-1722-S-L 7079 1811 x 2186 x 3042 1689 500 15 167.6 121.06 27 / 19.5 13.09 / 12.61 6.62 14.3
YSM50M-1526-S-L 7551 1621 x 2566 x 3137 1794 500 15 188.8 133.16 27 / 19.5 12.66 / 12.17 7.54 23.6 Bag filter • Power supply:
380V/3P/50Hz,
YSM50M-1726-S-L 8023 1811 x 2566 x 3137 1884 500 15 205.2 143.82 27 / 19.5 12.42 / 11.98 8.12 23.4
• Polyester synthetic fiber 380-415V/3/50Hz,
YSM50M-1726-S-L 8495 1811 x 2566 x 3137 1881 500 15 213.0 150.13 27 / 19.5 12.62 / 12.14 8.45 25 460V/3P/60Hz,
• Bag length of 300mm or
YSM50M-1728-S-L 8966 1811 x 2756 x 3137 2021 500 18.5 230.0 160.69 27 / 19.5 12.39 / 11.93 9.11 29.7 380V/3P/60Hz,
500mm
YSM50M-1728-S-L 9438 1811 x 2756 x 3137 2022 500 18.5 238.0 167.2 27 / 19.5 12.59 / 12.09 9.44 31.8 230V/3P/60Hz
• Filtering efficiency:
YSM50M-1730-S-L 9910 1811 x 2946 x 3327 2261 500 18.5 255.0 177.75 27 / 19.5 12.38 / 11.91 10.11 37.7
G3/G4/F5-F8
YSM50M-1730-S-L 10146 1811 x 2946 x 3327 2261 500 18.5 259.0 181 27 / 19.5 12.47 / 11.98 10.27 38.9 DIDW Fan
YSM50M-2028-S-L 10618 2096 x 2756 x 3327 2351 500 22 267.8 188.1 27 / 19.5 12.59 / 12.09 10.62 23.9
High efficiency filter • Fan can be equipped with a
YSM50M-2228-S-L 11090 2286 x 2756 x 3327 2498 500 22 285.8 199.24 27 / 19.5 12.32 / 11.88 11.39 23.2 double inlet, double width,
YSM50M-2228-S-L 11562 2286 x 2756 x 3327 2499 500 22 293.3 205.74 27 / 19.5 12.52 / 12.04 11.6 23.9 • Ultra fine glass fiber filter paper forward or backward curved
YSM50M-2429-S-L 12034 2476 x 2851 x 3327 2664 500 22 317.1 219.7 27 / 19.5 12.12 / 11.69 12.53 24.7 • V-shape pleated filter blade centrifugal fan. Fan inlet
YSM50M-2429-S-L 12506 2476 x 2851 x 3422 2725 500 22 326.2 226.69 27 / 19.5 12.23 / 11.79 12.98 26.4 cone is designed according to
• Filter efficiency: F9/H11/H13 the requirement of aerodynamic
YSM50M-2429-S-L 12978 2476 x 2851 x 3422 2718 500 22 333.3 232.6 27 / 19.5 12.38 / 11.92 13.21 27.3
performance. Impeller has been
YSM50M-2429-S-L 13450 2476 x 2851 x 3422 2832 500 30 342.2 239.43 27 / 19.5 12.49 / 12.01 13.67 29 statically and dynamically
YSM50M-2628-S-L 13922 2666 x 2756 x 3422 2872 500 30 352.7 247.52 27 / 19.5 12.54 / 12.07 13.92 25.8 balanced.
YSM50M-2433-S-L 14630 2476 x 3231 x 3422 3022 500 30 387.3 267.22 27 / 19.5 12.09 / 11.64 15.4 40.4
Eurovent certified casing performance
YSM50M-2433-S-L 15101 2476 x 3231 x 3422 3027 500 30 393.4 272.94 27 / 19.5 12.27 / 11.81 15.4 40.4
YSM50M-2436-S-L 15573 2476 x 3516 x 3707 3514 500 30 422.3 289.37 27 / 19.5 11.88 / 11.46 16.8 50.7 Mechanical Performance YSM
YSM50M-2633-S-L 16045 2666 x 3231 x 3612 3404 500 30 424.2 293.08 27 / 19.5 12.14 / 11.68 16.9 41.9
Panel Thicknes 50mm 25mm
YSM50M-2633-S-L 16517 2666 x 3231 x 3612 3403 500 30 431.7 299.25 27 / 19.5 12.26 / 11.79 17.1 43.1
YSM50M-2436-S-L 16989 2476 x 3516 x 3612 3458 500 30 445.9 308.18 27 / 19.5 12.22 / 11.74 17.7 55.9 Thermal Transmittance TB2 TB3
YSM50M-2834-S-L 17461 2856 x 3326 x 3612 3635 500 37 467.7 321.83 27 / 19.5 12.01 / 11.57 18.58 45.7
Air Leakage (-400/+700Pa) L1 L1
YSM50M-2834-S-L 17933 2856 x 3326 x 3612 3630 500 37 474.7 327.46 27 / 19.5 12.09 / 11.64 18.85 47
YSM50M-2834-S-L 18405 2856 x 3326 x 3707 3728 500 30 484.8 335.11 27 / 19.5 12.19 / 11.72 19.39 49.5 Casing Strength D1 D1
YSM50M-2834-S-L 18877 2856 x 3326 x 3707 3767 500 37 490.4 340.31 27 / 19.5 12.32 / 11.83 19.39 49.5 Filter Bypass Leakage F9 F9

21
YORK® Hygienic Air Handling Units (YMA-H) - Saudi Origin

YORK® Hygienic Air Handling Units (YMA-H)

Offering unique solutions to the application of Central Station Air Conditioning in a sterile environment.
There are many factors affecting air quality, comfort conditions and the efficient operation of Air
Handling Units. These include:

• Mechanical performance
• Thermal transmission through the Air Handling Unit casing
• Air leakage
• Noise transmission
• Bacteria protection
• Air cleanliness and filter efficiency
• Fan and motor efficiency
• Dehumidification
• Humidification

These factors are valid for the air conditioning of commercial buildings and hotels etc., as well as
hygiene sensitive environments such as hospitals, laboratories, clean rooms, food processing and a
variety of other process systems.
* The tested Hygienic Air Handling Unit is According to DIN 1946-4:2018 (“Ventilation and air conditioning - Part
4: Ventilation in buildings and rooms of health care”) and VDI 6022-1:2018 (“Ventilation and indoor-air quality –
Hygiene requirements for ventilation and air-conditioning systems and units”) confirmed by “TÜV NORD Systems
GmbH & Co. KG, Hamburg, Germany”

22
YORK® Multi Fans Air Handling Units (YMA–M) - Saudi Origin

YORK® Multi Fans Air Handling Units (YMA–M)

Advanced Direct Drive Plenum Fan Multi-Fan System Arrangement


With the YORK® Multi fan solution, fan retrofits can be performed at a fraction
of the cost. No longer are cranes and major construction costs required to
perform a fan upgrade. Existing fans can be disassembled and removed, while
new lightweight small stack fans are brought in through existing elevators and 10 fans 3 fans
or door ways. Most fan arrays will meet “n+1” configuration allowing for zero
system performance loss if one fan goes down. Snapped belts and loss of
system air flow are problems of the past with multi fan technology.
Key system Features
• Multi fan system has a shorter plenums, in Fact an average of 15% reduction in
length is visible.
16 fans 4 fans
• Multi fan system increase unit reliability & redundancy
• Smaller and lighter weight components
• Multiple fan system provide a more homogenous flow pattern through the coils.
• Motor replacement is simpler and quicker, there are no belts to install or
couplings to align.
• Multiple fan system lowering the noise level & Vibration compared to single
centrifugal fan.

Electronically Commutated Motor (ECM)


Cleveland Clinic, Abu Dhabi,
ECM technology consists of a brushless motor combined to a dedicated UAE. 155 Multi Fans AHUs
installed (AC motors)
electronic device (inverter), a magnet rotor. The controller uses a modulating
signal with 0-10Vdc tension in order to regulate the fan speed.
Applications
• Retrofit Applications • Clean rooms
Integrated drive &
High Interface • Air Handlers • Commercial Facilities
performance
Impeller • General supply and return • Hospitals & Healthcare
exhaust facilities Princess Noura University,
Riyadh, KSA. 700 Multi Fans
• Telecom data centers • Universities & Schools AHUs
EC Motor

23
YORK® YMS Modular Air Handling Units - Saudi Origin

Configuration 1: With Mixing Box


YMS Configuration 1: With Mixing Box
UNIT MODEL / GENERAL FAN COOLING COIL

Supply Motor Total Sensible Entering Return Leaving Air Water Water A Fan Section
Height Width Depth Weight ESP
Model Name Air Flow Power Capacity Capacity Air Temp Temp Flow Pressure Drop
B Chilled
L/S mm kg Pa kW kW kW DB / WB (°C) DB / WB (°C) L/S kPa
Water Coil +
YMS 30 x 30 800 923 923 3472 521 300 1.5 19.8 15.2 24.4 / 17.2 13 / 12.9 0.5 3.8
Eliminator
YMS 30 x 50 1450 923 1329 3472 636 300 3 36.5 27.6 24.4 / 17.2 13 / 12.8 1 11.9
YMS 30 x 60 1950 923 1735 3472 772 300 3 50 37.1 24.4 / 17.2 13 / 12.6 1.3 21.2 C Bag Filter
YMS 50 x 50 2350 1329 1329 3472 810 300 4 60.3 44.7 24.4 / 17.2 13 / 12.6 1.6 11.7 D Flat Filter
YMS 50 x 60 3400 1329 1735 3472 980 300 5.5 87.2 64.8 24.4 / 17.2 13 / 12.6 2.3 14.6
YMS 50 x 80 4450 1329 2142 3878 1178 300 7.5 117.2 84.5 24.4 / 17.2 13 / 12.4 3.1 50.2 E Mixing Box
YMS 60 x 60 4650 1735 1735 3878 1194 300 7.5 119.3 88.6 24.4 / 17.2 13 / 12.6 3.2 13.3
YMS 60 x 80 6200 1735 2142 3878 1397 300 11 163.3 117.8 24.4 / 17.2 13 / 12.4 4.3 50.7
YMS 60 x 100 7650 1735 2548 4395 1904 300 11 201.5 145.3 24.4 / 17.2 13 / 12.4 5.4 45.5
YMS Configuration 2: Fresh Air Unit
YMS 80 x 80 8250 2142 2142 4395 1938 300 11 217.3 156.7 24.4 / 17.2 13 / 12.4 5.8 50.6
YMS 80 x 100 10200 2142 2548 4395 2306 300 15 268.6 193.7 24.4 / 17.2 13 / 12.4 7.1 47.4 A Fan Section
Configuration 2: Fresh Air Units B Chilled
UNIT MODEL / GENERAL FAN COOLING COIL
Water Coil +
Eliminator
Supply Motor Total Sensible Entering Fresh Leaving Air Water Water
Height Width Depth Weight ESP C Bag Filter
Model Name Air Flow Power Capacity Capacity Air Temp Temp Flow Pressure Drop
L/S mm kg Pa kW kW kW DB / WB (°C) DB / WB (°C) L/S kPa D Flat Filter
YMS 30 x 30 800 923 923 2659 449 300 1.5 55.4 32 46 / 29 13 / 12.7 1.5 24.6
YMS 30 x 50 1450 923 1329 2659 573 300 3 100.5 58 46 / 29 13 / 12.7 2.7 42
YMS 30 x 60 1950 923 1735 2659 705 300 4 135.1 77.9 46 / 29 13 / 12.7 3.6 31.2
YMS 50 x 50 2350 1329 1329 2659 740 300 4 162.9 93.9 46 / 29 13 / 12.7 4.3 45.9
YMS 50 x 60 3400 1329 1735 2659 918 300 5.5 235.6 135.9 46 / 29 13 / 12.7 6.3 37
YMS 50 x 80 4450 1329 2142 3065 1135 300 7.5 308.4 177.8 46 / 29 13 / 12.7 8.2 33
YMS 60 x 60 4650 1735 1735 3065 1153 300 7.5 322.3 185.9 46 / 29 13 / 12.7 8.6 36.1
YMS 60 x 80 6200 1735 2142 3065 1374 300 11 429.7 247.8 46 / 29 13 / 12.7 11.4 33.9
YMS 60 x 100 7650 1735 2548 3472 1640 300 11 530.2 305.7 46 / 29 13 / 12.7 14.1 19.7
YMS 80 x 80 8250 2142 2142 3472 1691 300 11 571.8 329.7 46 / 29 13 / 12.7 15.2 33.8
YMS 80 x 100 10200 2142 2548 3472 2035 300 15 706.9 407.6 46 / 29 13 / 12.7 18.8 19.8

• Maximum coil face velocity is 2.5 m/s.


• Chilled water in/out temperature 5.5°C / 14.5°C.
• Height indicated above doesn’t include the base frame 100mm.
• Power supply 380V/3Ph/60Hz.

24
FAN COIL
UNITS
YORK® Chilled Water Fan Coil Units - Saudi/China Origins

STD ∆ T (10°F [5.56C]) - Standard Applications


YGFC STD SERIES (DECORATIVE) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 0 Pa
CHW WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP POWER INPUT WEIGHT
MODEL FLOW DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
YGFC 02 ST CE -3R 254 120 8.52 2.50 6.01 1.76 58.2 14.6 56.5 13.6 1.700 0.107 4.9 14.7 41 906 542 262 32
W ISO 9001:2015
ISO 14001: 2015
YGFC 03 ST CE -3R 327 155 12.98 3.80 8.46 2.48 56.2 13.4 54.3 12.4 2.590 0.163 11.3 33.8 54 1026 542 262 35
OHSAS 18001: 2007
YGFC 04 ST CE -3R 412 195 14.65 4.29 9.94 2.91 57.7 14.3 55.8 13.2 2.930 0.185 5.3 15.9 77 1147 542 262 39
YGFC 05 ST CE -3R 547 259 18.92 5.55 12.83 3.76 58.4 14.7 56.1 13.4 3.780 0.238 7.6 22.8 128 1168 542 262 41 H
YGFC 06 ST CE -3R 617 292 21.29 6.24 14.52 4.26 58.3 14.6 56.2 13.4 4.250 0.268 9.2 27.5 144 1388 542 262 46
YGFC 07 ST CE -3R 763 361 24.82 7.27 17.34 5.08 59.0 15.0 56.9 13.8 4.960 0.313 6.8 20.4 187 1510 542 262 55
YGFC 08 ST CE -3R 805 380 26.64 7.81 18.53 5.43 58.8 14.9 56.7 13.7 5.320 0.336 8.6 25.7 188 1630 542 262 62 L
YGFC 10 ST CE -3R 993 469 30.33 8.89 21.64 6.34 59.9 15.5 57.5 14.2 6.060 0.382 4.1 12.3 231 1750 542 262 63
YGFC 12 ST CE -3R 1083 512 34.82 10.21 24.34 7.13 59.3 15.2 57.0 13.9 6.960 0.439 5.5 16.5 259 1990 542 262 69
YGFC 14 ST CE -3R 1348 637 45.92 13.46 31.18 9.14 58.7 14.8 56.3 13.5 9.180 0.579 10.1 30.2 311 2230 542 262 83

YGFC STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 ST CB -3R 202 96 7.36 2.16 4.90 1.44 57.6 14.2 55.5 13.1 1.472 0.093 4.7 14.0 40 730 569 245 18 ISO 14001: 2015
YGFC 03 ST CB -3R 259 123 10.00 2.93 6.72 1.97 56.1 13.4 54.7 12.6 2.000 0.126 7.7 23.0 52 830 569 245 21 OHSAS 18001: 2007
H
YGFC 04 ST CB -3R 344 163 12.05 3.53 8.48 2.49 57.3 14.1 56.0 13.3 2.410 0.152 4.5 13.5 75 930 569 245 23
YGFC 05 ST CB -3R 480 227 15.61 4.58 11.32 3.32 58.3 14.6 56.9 13.8 3.122 0.197 7.7 22.9 124 1030 569 245 25
YGFC 06 ST CB -3R 547 259 18.29 5.36 13.17 3.86 57.8 14.3 56.5 13.6 3.659 0.231 10.0 29.9 142 1150 569 245 27
YGFC 08 ST CB -3R 703 332 24.16 7.08 17.26 5.06 57.4 14.1 56.2 13.4 4.832 0.305 9.5 28.5 184 1450 569 245 39
L
YGFC 10 ST CB -3R 870 411 26.63 7.81 20.45 5.99 58.3 14.6 57.5 14.2 5.325 0.336 4.5 13.6 227 1550 569 245 40
YGFC 12 ST CB -3R 935 442 29.75 8.72 21.88 6.41 58.4 14.7 57.1 13.9 5.950 0.375 5.8 17.3 254 1750 569 245 46
YGFC 14 ST CB -3R 1165 550 38.43 11.26 28.13 8.24 57.7 14.3 56.7 13.7 7.685 0.485 10.4 31.3 304 2050 575 245 57

YGFC-B STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 ST CB -3R-B 208 99 7.05 2.07 4.64 1.36 57.0 13.9 55.3 12.9 1.411 0.089 7.9 23.7 47 630 558 233 18 ISO 14001: 2015
YGFC 03 ST CB -3R-B 304 144 10.13 2.97 6.74 1.98 57.5 14.2 55.8 13.2 2.025 0.128 9.1 27.2 62 780 558 233 21 OHSAS 18001: 2007
H
YGFC 04 ST CB -3R-B 370 175 11.91 3.49 7.92 2.32 57.5 14.2 55.8 13.2 2.382 0.150 9.5 28.5 78 880 558 233 23
YGFC 05 ST CB -3R-B 466 220 15.16 4.44 10.22 3.00 58.3 14.6 56.4 13.6 3.031 0.191 8.9 26.7 113 930 558 233 25
YGFC 06 ST CB -3R-B 640 303 20.13 5.90 13.81 4.05 59.2 15.1 57.2 14.0 4.026 0.254 12.9 38.7 144 1030 558 233 27
YGFC 07 ST CB -3R-B 676 320 21.17 6.20 14.71 4.31 59.3 15.2 57.3 14.1 4.235 0.267 8.7 26.1 150 1200 558 233 36
YGFC 08 ST CB -3R-B 861 407 26.65 7.81 17.95 5.26 58.4 14.7 56.4 13.6 5.330 0.336 12.5 37.5 204 1400 558 233 39 L

YGFC 10 ST CB -3R-B 975 461 28.30 8.29 19.78 5.80 59.6 15.3 57.6 14.2 5.661 0.357 11.3 33.8 217 1450 558 233 40
YGFC 12 ST CB -3R-B 1238 585 34.73 10.18 24.20 7.09 59.6 15.3 57.5 14.2 6.945 0.438 12.6 37.8 285 1700 558 233 46
YGFC 14 ST CB -3R-B 1542 728 42.01 12.31 29.60 8.68 60.0 15.6 57.9 14.4 8.402 0.530 13.1 39.3 365 1950 558 233 57

YDFC STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 50 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
H
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
ISO 9001:2015
YDFC 08 ST CB -3R 838 396 25.47 7.47 17.68 5.18 59.4 15.2 57.0 13.9 5.093 0.321 8.7 26.1 261 1050 775 295 36 ISO 14001: 2015
YDFC 10 ST CB -3R 1165 550 34.23 10.03 23.18 6.79 59.1 15.1 56.5 13.6 6.847 0.432 20.1 60.1 297 1210 775 295 38 OHSAS 18001: 2007
YDFC 12 ST CB -3R 1385 654 38.32 11.23 26.72 7.83 59.7 15.4 57.2 14.0 7.664 0.484 12.3 36.9 389 1210 775 345 45
YDFC 14 ST CB -3R 1639 774 45.74 13.41 32.13 9.42 60.2 15.7 57.6 14.2 9.147 0.577 10.9 32.7 559 1340 775 345 50 L
YDFC 16 ST CB -3R 1856 876 49.68 14.56 35.89 10.52 60.8 16.0 58.1 14.5 9.936 0.627 10.9 32.5 623 1340 815 396 61 w
YDFC 18 ST CB -3R 2029 958 56.13 16.45 40.16 11.77 60.4 15.8 57.9 14.4 11.225 0.708 15.6 46.6 698 1480 815 396 74
YDFC 20 ST CB -3R 2357 1113 64.78 18.99 46.24 13.55 60.6 15.9 57.9 14.4 12.956 0.817 19.8 59.3 835 1610 815 396 78

26
YORK® Chilled Water Fan Coil Units - Saudi/China Origins

STD Δ T (10°F[5.56C]) - Standard Applications


YGFC STD SERIES (DECORATIVE) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 0 Pa
CHW WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP POWER INPUT WEIGHT
MODEL FLOW DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
W
YGFC 02 ST CE -3R 236 112 8.00 2.34 5.65 1.66 58.0 14.4 56.4 13.6 1.601 0.101 4.6 13.7 38 906 542 262 32 ISO 9001:2015
YGFC 03 ST CE -3R 303 143 12.04 3.53 7.90 2.32 56.0 13.3 54.3 12.4 2.408 0.152 10.0 29.9 51 1026 542 262 35 ISO 14001: 2015
OHSAS 18001: 2007
YGFC 04 ST CE -3R 379 179 13.78 4.04 9.33 2.73 57.3 14.1 55.5 13.1 2.756 0.174 4.4 13.2 68 1147 542 262 39
YGFC 05 ST CE -3R 486 230 17.40 5.10 11.72 3.44 57.8 14.3 55.7 13.2 3.481 0.220 6.4 19.3 118 1168 542 262 41 H
YGFC 06 ST CE -3R 566 268 19.99 5.86 13.58 3.98 57.9 14.4 55.9 13.3 3.997 0.252 8.6 25.7 131 1388 542 262 46
YGFC 07 ST CE -3R 712 337 23.47 6.88 16.41 4.81 58.7 14.8 56.7 13.7 4.695 0.296 6.5 19.5 173 1510 542 262 55
YGFC 08 ST CE -3R 748 353 25.09 7.35 17.47 5.12 58.5 14.7 56.5 13.6 5.019 0.317 7.4 22.3 174 1630 542 262 62 L
YGFC 10 ST CE -3R 905 428 28.31 8.30 20.14 5.90 59.5 15.3 57.3 14.1 5.661 0.357 3.6 10.7 218 1750 542 262 63
YGFC 12 ST CE -3R 1014 479 32.88 9.64 23.08 6.76 59.0 15.0 56.9 13.8 6.577 0.415 5.2 15.4 240 1990 542 262 69
YGFC 14 ST CE -3R 1264 597 42.75 12.53 29.31 8.59 58.6 14.8 56.4 13.6 8.550 0.539 9.3 27.8 297 2230 542 262 83

YGFC STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 ST CB -3R 188 89 6.97 2.04 4.61 1.35 57.4 14.1 55.2 12.9 1.394 0.088 4.1 12.4 37 730 569 245 18 ISO 14001: 2015
YGFC 03 ST CB -3R 239 113 9.47 2.78 6.25 1.83 55.9 13.3 54.3 12.4 1.895 0.120 7.2 21.5 49 830 569 245 21 OHSAS 18001: 2007
H
YGFC 04 ST CB -3R 315 149 11.28 3.31 7.85 2.30 57.0 13.9 55.7 13.2 2.256 0.142 4.1 12.2 66 930 569 245 23
YGFC 05 ST CB -3R 414 196 14.28 4.19 10.17 2.98 57.4 14.1 56.2 13.4 2.856 0.180 7.1 21.1 115 1030 569 245 25
YGFC 06 ST CB -3R 493 233 17.81 5.22 12.45 3.65 56.7 13.7 55.6 13.1 3.563 0.225 9.1 27.2 127 1150 569 245 27
YGFC 08 ST CB -3R 651 308 22.70 6.65 16.28 4.77 57.0 13.9 56.1 13.4 4.540 0.286 8.9 26.6 171 1450 569 245 39
L
YGFC 10 ST CB -3R 782 370 25.68 7.53 18.75 5.50 57.9 14.4 56.8 13.8 5.136 0.324 4.3 12.8 214 1550 569 245 40
YGFC 12 ST CB -3R 881 416 28.13 8.24 20.92 6.13 58.1 14.5 57.1 13.9 5.627 0.355 5.7 17.0 235 1750 569 245 46
YGFC 14 ST CB -3R 1082 511 34.39 10.08 25.99 7.62 57.9 14.4 57.1 13.9 6.877 0.434 9.9 29.6 290 2050 575 245 57

YGFC-B STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 ST CB -3R-B 174 83 6.25 1.83 4.07 1.19 56.4 13.6 54.8 12.7 1.250 0.079 6.5 19.5 42 630 558 233 18 ISO 14001: 2015
YGFC 03 ST CB -3R-B 259 123 9.10 2.67 6.02 1.76 57.1 13.9 55.5 13.1 1.820 0.115 7.7 23.1 56 780 558 233 21 OHSAS 18001: 2007
H
YGFC 04 ST CB -3R-B 309 146 10.72 3.14 7.07 2.07 57.1 13.9 55.4 13.0 2.143 0.135 8.2 24.6 68 880 558 233 23
YGFC 05 ST CB -3R-B 390 185 13.63 3.99 9.00 2.64 57.4 14.1 55.6 13.1 2.726 0.172 8.1 24.3 99 930 558 233 25
YGFC 06 ST CB -3R-B 517 244 17.49 5.13 11.80 3.46 58.4 14.7 56.4 13.6 3.498 0.221 10.4 31.1 123 1030 558 233 27
YGFC 07 ST CB -3R-B 551 261 18.54 5.43 12.66 3.71 58.5 14.7 56.7 13.7 3.707 0.234 7.1 21.3 126 1200 558 233 36
YGFC 08 ST CB -3R-B 748 353 24.36 7.14 16.30 4.78 58.0 14.4 56.1 13.4 4.873 0.307 10.8 32.2 173 1400 558 233 39 L

YGFC 10 ST CB -3R-B 805 380 24.23 7.10 16.91 4.96 59.3 15.2 57.4 14.1 4.846 0.306 8.8 26.3 191 1450 558 233 40
YGFC 12 ST CB -3R-B 953 450 29.53 8.66 20.19 5.92 58.7 14.8 56.8 13.8 5.905 0.373 9.8 29.5 235 1700 558 233 46
YGFC 14 ST CB -3R-B 1265 597 37.41 10.96 25.96 7.61 59.3 15.2 57.3 14.1 7.481 0.472 10.9 32.6 306 1950 558 233 57

YDFC STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
H
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
ISO 9001:2015
YDFC 08 ST CB -3R 834 394 24.42 7.16 24.42 17.22 59.7 15.4 57.3 14.1 4.883 0.308 6.8 20.3 251 1050 775 295 36 ISO 14001: 2015
YDFC 10 ST CB -3R 1118 528 31.42 9.21 31.42 21.80 59.5 15.3 57.0 13.9 6.284 0.396 16.4 49.0 273 1210 775 295 38 OHSAS 18001: 2007
YDFC 12 ST CB -3R 1325 626 37.15 10.89 37.15 25.93 59.6 15.3 57.2 14.0 7.429 0.469 11.7 34.9 365 1210 775 345 45
YDFC 14 ST CB -3R 1552 733 43.44 12.73 43.44 30.38 59.8 15.4 57.3 14.1 8.688 0.548 10.3 31.0 467 1340 775 345 50 L
YDFC 16 ST CB -3R 1787 844 48.40 14.19 48.40 34.91 60.6 15.9 58.0 14.4 9.681 0.611 10.3 30.7 580 1340 815 396 61 w
YDFC 18 ST CB -3R 1912 903 54.66 16.02 54.66 38.79 60.0 15.6 57.5 14.2 10.932 0.690 14.1 42.1 642 1480 815 396 74
YDFC 20 ST CB -3R 2247 1061 62.54 18.33 62.54 44.50 60.3 15.7 57.7 14.3 12.508 0.789 17.0 51.0 772 1610 815 396 78

27
YORK® Chilled Water Fan Coil Units - Saudi/China Origins

STD Δ T (10°F[5.56C]) - Standard Applications


YGFC STD SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 0 Pa
CHW WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP POWER INPUT WEIGHT
MODEL FLOW DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
YGFC 02 ST CE -4R 233 110 10.01 2.93 6.47 1.90 54.4 12.4 53.1 11.7 2.00 0.126 6.32 18.9 41.4 906 542 262 34.7
W ISO 9001:2015
ISO 14001: 2015
YGFC 03 ST CE -4R 309 146 11.97 3.51 8.01 2.35 56.1 13.4 54.6 12.6 2.39 0.151 3.71 11.1 54.0 1026 542 262 37.2
OHSAS 18001: 2007
YGFC 04 ST CE -4R 399 189 14.98 4.39 10.10 2.96 56.7 13.7 55.1 12.8 3.00 0.189 5.46 16.3 75.5 1147 542 262 41.1
YGFC 05 ST CE -4R 530 251 19.60 5.74 13.18 3.86 57.1 13.9 55.3 12.9 3.92 0.247 4.25 12.7 128.3 1168 542 262 43.8 H
YGFC 06 ST CE -4R 593 280 22.99 6.74 15.19 4.45 56.4 13.6 54.6 12.6 4.60 0.290 6.65 19.9 144.6 1388 542 262 48.4
YGFC 07 ST CE -4R 744 352 27.65 8.10 18.59 5.45 57.0 13.9 55.2 12.9 5.53 0.349 5.13 15.4 187.2 1510 542 262 55.9
YGFC 08 ST CE -4R 783 370 31.18 9.14 20.44 5.99 55.9 13.3 54.3 12.4 6.24 0.393 9.49 28.4 187.9 1630 542 262 62.5 L
YGFC 10 ST CE -4R 944 446 36.67 10.75 24.08 7.06 56.5 13.6 54.6 12.6 7.33 0.463 13.23 39.6 231.8 1750 542 262 64.2
YGFC 12 ST CE -4R 1061 501 39.69 11.63 26.53 7.78 57.0 13.9 55.1 12.8 7.94 0.501 4.44 13.3 258.8 1990 542 262 70.3
YGFC 14 ST CE -4R 1312 620 48.96 14.35 32.69 9.58 57.0 13.9 55.2 12.9 9.79 0.618 8.41 25.2 311.3 2230 542 262 84.2

YGFC STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 ST CB -4R 190 90 8.23 2.41 5.17 1.52 54.9 12.7 53.0 11.7 1.64 0.104 6.93 20.7 40.2 730 569 245 19 ISO 14001: 2015
YGFC 03 ST CB -4R 249 118 10.18 2.98 6.68 1.96 55.3 12.9 53.9 12.2 2.035 0.128 3.58 10.7 52.2 830 569 245 22.1 OHSAS 18001: 2007
H
YGFC 04 ST CB -4R 329 156 13.26 3.89 8.87 2.60 55.2 12.9 54.1 12.3 2.651 0.167 6.46 19.3 73.2 930 569 245 24.4
YGFC 05 ST CB -4R 459 217 16.25 4.76 11.38 3.34 57.1 13.9 55.9 13.3 3.249 0.205 4.69 14.0 124.4 1030 569 245 26
YGFC 06 ST CB -4R 505 239 19.74 5.79 13.51 3.96 55.4 13.0 54.5 12.5 3.948 0.249 7.31 21.9 141.6 1150 569 245 28.6
YGFC 08 ST CB -4R 680 321 25.35 7.43 17.72 5.19 56.0 13.3 55.2 12.9 5.07 0.320 8.53 25.5 184.4 1450 569 245 41.1
L
YGFC 10 ST CB -4R 818 387 30.03 8.80 20.99 6.15 56.4 13.6 55.4 13.0 6.006 0.379 12.25 36.7 226.8 1550 569 245 42.5
YGFC 12 ST CB -4R 929 439 33.19 9.73 23.61 6.92 56.6 13.7 55.7 13.2 6.637 0.419 7.09 21.2 253.5 1750 569 245 47.7
YGFC 14 ST CB -4R 1145 541 40.17 11.77 29.03 8.51 56.6 13.7 56.0 13.3 8.034 0.507 7.02 21.0 303.6 2050 575 245 58.5

YGFC-B STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 ST CB -4R-B 199 94 8.16 2.39 5.28 1.55 54.1 12.3 53.2 11.8 1.63 0.103 10.14 30.4 47.2 630 558 233 19 ISO 14001: 2015
YGFC 03 ST CB -4R-B 291 138 12.28 3.60 7.95 2.33 54.2 12.3 53.3 11.8 2.457 0.155 13.18 39.5 62.3 780 558 233 22.1 OHSAS 18001: 2007
H
YGFC 04 ST CB -4R-B 346 164 13.99 4.10 9.1 2.67 54.4 12.4 53.5 11.9 2.798 0.177 16.01 47.9 78.4 880 558 233 24.4
YGFC 05 ST CB -4R-B 444 210 17.03 4.99 11.2 3.28 55 12.8 54.1 12.3 3.406 0.215 14.94 44.7 111.9 930 558 233 26
YGFC 06 ST CB -4R-B 611 289 22.36 6.55 14.97 4.39 56 13.3 55 12.8 4.472 0.282 12.65 37.9 143.4 1030 558 233 28.6
YGFC 07 ST CB -4R-B 638 302 23.81 6.98 15.88 4.65 55.7 13.2 54.7 12.6 4.761 0.300 13.03 39.0 145.4 1200 558 233 38.5
YGFC 08 ST CB -4R-B 824 389 30.61 8.97 20.42 5.99 55.7 13.2 54.8 12.7 6.122 0.386 14.02 42.0 200.4 1400 558 233 41.1 L

YGFC 10 ST CB -4R-B 891 421 31.21 9.15 21.17 6.20 56.4 13.6 55.4 13.0 6.242 0.394 11.6 34.7 216.4 1450 558 233 42.5
YGFC 12 ST CB -4R-B 1158 547 41.44 12.15 27.68 8.11 55.9 13.3 54.9 12.7 8.288 0.523 16.58 49.6 282.6 1700 558 233 47.7
YGFC 14 ST CB -4R-B 1467 693 53.15 15.58 35.43 10.38 56 13.3 54.9 12.7 10.631 0.671 25.36 75.9 359.2 1950 558 233 58.5

YDFC STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 50 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
H
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
ISO 9001:2015
YDFC 08 ST CB -4R 800 378 26.9 7.88 18.75 5.50 57.1 13.9 55.8 13.2 5.38 0.339 6.03 18.1 247 1050 775 295 49 ISO 14001: 2015
YDFC 10 ST CB -4R 1088 514 34.9 10.23 23.98 7.03 56.8 13.8 55.4 13.0 6.98 0.440 14.55 43.6 321.4 1210 775 295 51 OHSAS 18001: 2007
YDFC 12 ST CB -4R 1298 613 42.96 12.59 29.16 8.55 56.4 13.6 55 12.8 8.592 0.542 11.38 34.1 413.2 1210 775 345 59
YDFC 14 ST CB -4R 1568 740 50.81 14.89 35.22 10.32 57.4 14.1 55.8 13.2 10.162 0.641 13.66 40.9 598.3 1340 775 345 65 L
YDFC 16 ST CB -4R 1807 853 57.98 16.99 40.61 11.90 57.6 14.2 56.1 13.4 11.595 0.732 8.55 25.6 662.3 1340 815 396 77 w
YDFC 18 ST CB -4R 1937 915 64.73 18.97 44.8 13.13 57.1 13.9 55.7 13.2 12.947 0.817 12.29 36.8 740.1 1480 815 396 92
YDFC 20 ST CB -4R 2234 1055 68.85 20.18 49.3 14.45 58.1 14.5 56.7 13.7 13.771 0.869 6.91 20.7 858.6 1610 815 396 97

28
YORK® Chilled Water Fan Coil Units - Saudi/China Origins

STD Δ T (10°F[5.56C]) - Standard Applications


YGFC STD SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 0 Pa
CHW WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP POWER INPUT WEIGHT
MODEL FLOW DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
W
YGFC 02 ST CE -4R 216 102 9.40 2.76 6.08 1.78 54.1 12.3 52.9 11.6 1.881 0.119 5.5 16.4 39 906 542 262 35 ISO 9001:2015
YGFC 03 ST CE -4R 287 136 11.34 3.32 7.57 2.22 55.7 13.2 54.4 12.4 2.267 0.143 3.0 9.1 51 1026 542 262 37 ISO 14001: 2015
OHSAS 18001: 2007
YGFC 04 ST CE -4R 363 172 13.95 4.09 9.36 2.74 56.2 13.4 54.8 12.7 2.791 0.176 5.0 14.9 72 1147 542 262 41
YGFC 05 ST CE -4R 481 227 17.94 5.26 12.09 3.54 56.8 13.8 55.2 12.9 3.589 0.226 3.5 10.4 118 1168 542 262 44 H
YGFC 06 ST CE -4R 549 260 21.63 6.34 14.29 4.19 56.0 13.3 54.4 12.4 4.327 0.273 5.9 17.7 131 1388 542 262 48
YGFC 07 ST CE -4R 689 326 25.89 7.59 17.41 5.10 56.7 13.7 55.1 12.8 5.179 0.327 4.0 11.9 173 1510 542 262 56
YGFC 08 ST CE -4R 716 338 29.29 8.58 19.11 5.60 55.4 13.0 53.9 12.2 5.857 0.370 8.4 25.3 175 1630 542 262 63 L
YGFC 10 ST CE -4R 876 414 34.96 10.25 22.83 6.69 56.0 13.3 54.2 12.3 6.993 0.441 12.0 35.9 218 1750 542 262 64
YGFC 12 ST CE -4R 977 462 36.95 10.83 24.72 7.25 56.7 13.7 55.0 12.8 7.390 0.466 3.5 10.5 240 1990 542 262 70
YGFC 14 ST CE -4R 1200 567 44.95 13.17 30.12 8.83 56.9 13.8 55.1 12.8 8.989 0.567 7.2 21.5 298 2230 542 262 84

YGFC STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 ST CB -4R 176 84 7.76 2.27 4.84 1.42 54.7 12.6 52.7 11.5 1.553 0.098 6.2 18.7 37 730 569 245 19 ISO 14001: 2015
YGFC 03 ST CB -4R 231 110 9.62 2.82 6.25 1.83 55.1 12.8 53.6 12.0 1.925 0.121 3.3 9.8 49 830 569 245 22 OHSAS 18001: 2007
H
YGFC 04 ST CB -4R 290 137 11.37 3.33 7.68 2.25 55.6 13.1 54.5 12.5 2.273 0.143 4.8 14.5 69 930 569 245 24
YGFC 05 ST CB -4R 407 193 15.27 4.48 10.43 3.06 56.4 13.6 55.1 12.8 3.053 0.193 4.2 12.5 115 1030 569 245 26
YGFC 06 ST CB -4R 467 221 18.64 5.46 12.66 3.71 55.0 12.8 54.2 12.3 3.728 0.235 7.1 21.2 128 1150 569 245 29
YGFC 08 ST CB -4R 623 295 24.74 7.25 16.88 4.95 55.0 12.8 54.3 12.4 4.949 0.312 8.0 24.0 171 1450 569 245 41
L
YGFC 10 ST CB -4R 755 357 28.98 8.49 20.01 5.86 55.6 13.1 54.8 12.7 5.796 0.366 11.2 33.6 214 1550 569 245 43
YGFC 12 ST CB -4R 847 400 31.26 9.16 21.99 6.45 56.1 13.4 55.3 12.9 6.253 0.395 4.8 14.3 235 1750 569 245 48
YGFC 14 ST CB -4R 1034 488 38.96 11.42 27.31 8.00 55.7 13.2 55.0 12.8 7.793 0.492 7.0 20.9 290 2050 575 245 59

YGFC-B STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 ST CB -4R-B 168 80 7.38 2.16 4.70 1.38 53.1 11.7 52.3 11.3 1.477 0.093 8.6 25.6 42 630 558 233 19 ISO 14001: 2015
YGFC 03 ST CB -4R-B 246 117 10.80 3.17 6.90 2.02 53.4 11.9 52.6 11.4 2.159 0.136 10.5 31.4 55 780 558 233 22 OHSAS 18001: 2007
H
YGFC 04 ST CB -4R-B 292 138 12.38 3.63 7.96 2.33 53.8 12.1 53.0 11.7 2.475 0.156 12.6 37.8 68 880 558 233 24
YGFC 05 ST CB -4R-B 374 177 15.24 4.47 9.89 2.90 54.3 12.4 53.4 11.9 3.049 0.192 13.4 40.3 98 930 558 233 26
YGFC 06 ST CB -4R-B 493 233 19.09 5.60 12.52 3.67 54.9 12.7 54.0 12.2 3.818 0.241 9.3 27.9 122 1030 558 233 29
YGFC 07 ST CB -4R-B 520 246 20.72 6.07 13.58 3.98 54.8 12.7 53.9 12.2 4.143 0.261 10.4 31.3 123 1200 558 233 39
YGFC 08 ST CB -4R-B 724 342 27.58 8.08 18.27 5.35 55.3 12.9 54.4 12.4 5.515 0.348 12.0 36.0 173 1400 558 233 41 L

YGFC 10 ST CB -4R-B 783 370 28.97 8.49 19.30 5.66 55.6 13.1 54.6 12.6 5.793 0.365 9.7 29.1 192 1450 558 233 43
YGFC 12 ST CB -4R-B 888 420 34.66 10.16 22.68 6.65 54.8 12.7 53.9 12.2 6.931 0.437 13.1 39.2 235 1700 558 233 48
YGFC 14 ST CB -4R-B 1193 564 45.83 13.43 30.04 8.80 55.0 12.8 54.0 12.2 9.165 0.578 20.5 61.3 302 1950 558 233 59

YDFC STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
H
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
ISO 9001:2015
YDFC 08 ST CB -4R 777 367 26.36 7.73 18.31 5.37 56.8 13.8 55.6 13.1 5.272 0.333 5.7 17.1 234 1050 775 295 49 ISO 14001: 2015
YDFC 10 ST CB -4R 1022 483 33.94 9.95 23.08 6.76 56.3 13.5 55.0 12.8 6.788 0.428 13.0 38.9 265 1210 775 295 51 OHSAS 18001: 2007
YDFC 12 ST CB -4R 1241 586 41.84 12.26 28.36 8.31 56.2 13.4 54.9 12.7 8.368 0.528 10.7 32.0 360 1210 775 345 59
YDFC 14 ST CB -4R 1491 704 48.74 14.29 33.48 9.81 56.8 13.8 55.4 13.0 9.749 0.615 13.1 39.3 493 1340 775 345 65 L
YDFC 16 ST CB -4R 1744 824 56.83 16.66 39.64 11.62 57.4 14.1 56.0 13.3 11.365 0.717 8.4 25.1 577 1340 815 396 77 w
YDFC 18 ST CB -4R 1836 867 62.93 18.44 43.26 12.68 56.8 13.8 55.4 13.0 12.586 0.794 11.5 34.3 628 1480 815 396 92
YDFC 20 ST CB -4R 2148 1014 66.71 19.55 47.60 13.95 57.9 14.4 56.5 13.6 13.342 0.842 6.6 19.8 769 1610 815 396 97

29
YORK® Chilled Water Fan Coil Units - Saudi/China Origins

High Δ T (16°F[8.9C]) - District Cooling Applications


YGFC DC SERIES (DECORATIVE) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 0 Pa
CHW WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP POWER INPUT WEIGHT
MODEL FLOW DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
YGFC 02 DC CE -3R 248 118 9.29 2.72 6.24 1.83 56.8 13.8 55.1 12.8 1.16 0.073 14.41 43.1 38.2 906 542 262 32.1
W ISO 9001:2015
ISO 14001: 2015
YGFC 03 DC CE -3R 344 163 13.59 3.98 8.84 2.59 56.3 13.5 54.4 12.4 1.698 0.107 30.89 92.5 54.6 1026 542 262 34.6
OHSAS 18001: 2007
YGFC 04 DC CE -3R 416 197 16.19 4.75 10.59 3.10 56.5 13.6 54.6 12.6 2.024 0.128 6.96 20.8 66 1147 542 262 38.5
YGFC 05 DC CE -3R 552 261 20.51 6.01 13.49 3.95 57.5 14.2 55.2 12.9 2.564 0.162 11.82 35.4 128 1168 542 262 41.3 H
YGFC 06 DC CE -3R 651 308 22.87 6.70 15.39 4.51 58.2 14.6 56 13.3 2.859 0.180 15.75 47.2 144.1 1388 542 262 45.8
YGFC 07 DC CE -3R 779 368 26.67 7.82 18.21 5.34 58.4 14.7 56.3 13.5 3.334 0.210 22.93 68.7 186.8 1510 542 262 55.0
YGFC 08 DC CE -3R 805 380 26.38 7.73 18.43 5.40 58.9 14.9 56.8 13.8 3.297 0.208 9.7 29.0 187.7 1630 542 262 61.5 L
YGFC 10 DC CE -3R 1000 472 31.15 9.13 22.02 6.45 59.7 15.4 57.3 14.1 3.893 0.246 14.05 42.1 231.1 1750 542 262 63.2
YGFC 12 DC CE -3R 1195 564 38.01 11.14 26.48 7.76 59.6 15.3 57.1 13.9 4.751 0.300 25.28 75.7 257.4 1990 542 262 69.2
YGFC 14 DC CE -3R 1418 670 45.25 13.26 31.53 9.24 59.5 15.3 57.1 13.9 5.656 0.357 17.71 53.0 309.9 2230 542 262 83.0

YGFC DC SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 DC CB -3R 192 91 7.42 2.17 5.01 1.47 56 13.3 54.7 12.6 0.93 0.059 9.05 27.1 36.4 730 569 245 18 ISO 14001: 2015
YGFC 03 DC CB -3R 273 129 11.35 3.33 7.37 2.16 55.1 12.8 53.6 12.0 1.419 0.090 21.76 65.1 52.5 830 569 245 20.8 OHSAS 18001: 2007
H
YGFC 04 DC CB -3R 352 167 14.08 4.13 9.23 2.71 55.8 13.2 54.2 12.3 1.76 0.111 5.51 16.5 63.8 930 569 245 23.4
YGFC 05 DC CB -3R 485 229 18.59 5.45 12.22 3.58 56.8 13.8 54.8 12.7 2.323 0.147 9.73 29.1 124.3 1030 569 245 24.9
YGFC 06 DC CB -3R 578 273 20.84 6.11 14.05 4.12 57.6 14.2 55.6 13.1 2.605 0.164 13.59 40.7 141.5 1150 569 245 27.4
YGFC 08 DC CB -3R 703 332 23.31 6.83 16.42 4.81 58.5 14.7 56.6 13.7 2.914 0.184 8.81 26.4 184.3 1450 569 245 38.7
L
YGFC 10 DC CB -3R 885 418 28.24 8.28 20.01 5.86 59.2 15.1 57.1 13.9 3.53 0.223 12.04 36.0 226.6 1550 569 245 40.3
YGFC 12 DC CB -3R 1055 498 33.43 9.80 23.69 6.94 59.3 15.2 57.2 14.0 4.179 0.264 20.43 61.2 253.5 1750 569 245 45.8
YGFC 14 DC CB -3R 1253 592 40.69 11.93 28.53 8.36 59 15.0 56.9 13.8 5.086 0.321 14.98 44.9 303.5 2050 575 245 56.5

YGFC-B DC SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 DC CB -3R-B 208 99 7.15 2.10 4.81 1.41 57.8 14.3 56.1 13.4 0.89 0.056 10.5 31.4 47.4 630 558 233 18 ISO 14001: 2015
YGFC 03 DC CB -3R-B 304 144 10.41 3.05 7.05 2.07 58.2 14.6 56.4 13.6 1.301 0.082 14.57 43.6 62.3 780 558 233 20.8 OHSAS 18001: 2007
H
YGFC 04 DC CB -3R-B 370 175 12.19 3.57 8.21 2.41 58.1 14.5 56.3 13.5 1.523 0.096 13.99 41.9 77.6 880 558 233 23.4
YGFC 05 DC CB -3R-B 466 220 15.19 4.45 10.29 3.02 58.5 14.7 56.6 13.7 1.899 0.120 14.42 43.2 112.6 930 558 233 24.9
YGFC 06 DC CB -3R-B 640 303 19.69 5.77 13.58 3.98 59.4 15.2 57.3 14.1 2.461 0.155 19.07 57.1 143.8 1030 558 233 27.4
YGFC 07 DC CB -3R-B 676 320 21.1 6.18 14.58 4.27 59.1 15.1 57.2 14.0 2.638 0.166 26.96 80.7 149.6 1200 558 233 36.3
YGFC 08 DC CB -3R-B 861 407 26.64 7.81 18.51 5.43 59.4 15.2 57.4 14.1 3.33 0.210 13.65 40.9 203.8 1400 558 233 38.7 L

YGFC 10 DC CB -3R-B 975 461 28.94 8.48 20.42 5.99 59.9 15.5 57.9 14.4 3.618 0.228 13.09 39.2 216.5 1450 558 233 40.3
YGFC 12 DC CB -3R-B 1238 585 33.22 9.74 24.01 7.04 60.5 15.8 58.4 14.7 4.153 0.262 16.43 49.2 284.9 1700 558 233 45.8
YGFC 14 DC CB -3R-B 1543 729 42.15 12.35 30.74 9.01 61 16.1 58.8 14.9 5.269 0.332 16.28 48.7 364.6 1950 558 233 56.5

YDFC DC SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 50 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
H
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
ISO 9001:2015
YDFC 08 DC CB -3R 855 404 27.2 7.97 18.43 5.40 58.8 14.9 56.4 13.6 3.40 0.215 25.12 75.2 268.4 1050 775 295 36 ISO 14001: 2015
YDFC 10 DC CB -3R 1236 584 31.03 9.09 21.85 6.40 60 15.6 57.4 14.1 3.879 0.245 28.18 84.4 296.8 1210 775 295 38 OHSAS 18001: 2007
YDFC 12 DC CB -3R 1388 656 40.59 11.90 27.48 8.05 59 15.0 56.4 13.6 5.074 0.320 21.54 64.5 397.9 1210 775 345 45
YDFC 14 DC CB -3R 1689 798 45.27 13.27 31.82 9.33 60.2 15.7 57.5 14.2 5.659 0.357 15.61 46.7 551.1 1340 775 345 50 L
YDFC 16 DC CB -3R 1911 902 55.27 16.20 37.89 11.11 59.6 15.3 56.9 13.8 6.909 0.436 22.76 68.1 646.4 1340 815 396 61 w
YDFC 18 DC CB -3R 2029 958 56.65 16.60 40.01 11.73 60.1 15.6 57.5 14.2 7.081 0.447 29.77 89.1 700.6 1480 815 396 74
YDFC 20 DC CB -3R 2368 1118 65.26 19.13 46.02 13.49 60.2 15.7 57.6 14.2 8.157 0.515 24.83 74.3 809.8 1610 815 396 78

30
YORK® Chilled Water Fan Coil Units - Saudi/China Origins

High Δ T (16°F[8.9C]) - District Cooling Applications


YGFC DC SERIES (DECORATIVE) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - MEDIUM SPEED - 0 Pa
CHW WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP POWER INPUT WEIGHT
MODEL FLOW DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
W
YGFC 02 DC CE -3R 224 106 8.42 2.47 5.7 1.67 56.6 13.7 55.1 12.8 1.05 0.066 12.57 37.6 34 906 542 262 32.1 ISO 9001:2015
YGFC 03 DC CE -3R 298 141 12.18 3.57 7.92 2.32 55.5 13.1 53.9 12.2 1.523 0.096 24.9 74.6 45.1 1026 542 262 34.6 ISO 14001: 2015
OHSAS 18001: 2007
YGFC 04 DC CE -3R 383 181 15.03 4.41 9.85 2.89 56.3 13.5 54.5 12.5 1.878 0.118 6.74 20.2 56 1147 542 262 38.5
YGFC 05 DC CE -3R 512 242 19.52 5.72 12.78 3.75 57 13.9 54.9 12.7 2.44 0.154 10.21 30.6 118 1168 542 262 41.3 H
YGFC 06 DC CE -3R 601 284 21.73 6.37 14.56 4.27 57.7 14.3 55.6 13.1 2.716 0.171 14.16 42.4 130.4 1388 542 262 45.8
YGFC 07 DC CE -3R 711 336 24.69 7.24 16.92 4.96 58.1 14.5 56.1 13.4 3.086 0.195 20.82 62.3 172.7 1510 542 262 55.0
YGFC 08 DC CE -3R 748 353 24.8 7.27 17.36 5.09 58.6 14.8 56.6 13.7 3.1 0.196 8.82 26.4 174.4 1630 542 262 61.5 L
YGFC 10 DC CE -3R 913 431 29.17 8.55 20.57 6.03 59.2 15.1 57.1 13.9 3.646 0.230 12.45 37.3 218 1750 542 262 63.2
YGFC 12 DC CE -3R 1102 521 34.85 10.21 24.55 7.20 59.5 15.3 57.2 14.0 4.357 0.275 22.35 66.9 238.7 1990 542 262 69.2
YGFC 14 DC CE -3R 1282 606 41.52 12.17 29.01 8.50 59.1 15.1 56.9 13.8 5.19 0.327 14.18 42.5 296.9 2230 542 262 83.0

YGFC DC SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (5.55/14.5 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 DC CB -3R 178 85 7.09 2.08 4.74 1.39 55.4 13.0 54.2 12.3 0.89 0.056 9.29 27.8 32.6 730 569 245 18 ISO 14001: 2015
YGFC 03 DC CB -3R 240 114 10.52 3.08 6.75 1.98 54.1 12.3 52.7 11.5 1.315 0.083 19.36 58.0 42.2 830 569 245 20.8 OHSAS 18001: 2007
H
YGFC 04 DC CB -3R 317 150 12.96 3.80 8.48 2.49 55.3 12.9 53.9 12.2 1.62 0.102 5.25 15.7 52.6 930 569 245 23.4
YGFC 05 DC CB -3R 448 212 17.49 5.13 11.48 3.36 56.4 13.6 54.5 12.5 2.186 0.138 7.56 22.6 115.1 1030 569 245 24.9
YGFC 06 DC CB -3R 533 252 18.81 5.51 12.88 3.78 57.7 14.3 55.9 13.3 2.351 0.148 12.63 37.8 127.4 1150 569 245 27.4
YGFC 08 DC CB -3R 651 308 21.83 6.40 15.38 4.51 58.2 14.6 56.5 13.6 2.728 0.172 8.11 24.3 171.1 1450 569 245 38.7
L
YGFC 10 DC CB -3R 804 380 26.55 7.78 18.66 5.47 58.6 14.8 56.7 13.7 3.319 0.209 10.73 32.1 213.7 1550 569 245 40.3
YGFC 12 DC CB -3R 967 457 31.27 9.17 22.11 6.48 58.9 14.9 56.9 13.8 3.908 0.247 18.74 56.1 234.7 1750 569 245 45.8
YGFC 14 DC CB -3R 1116 527 37.47 10.98 26.12 7.66 58.4 14.7 56.5 13.6 4.684 0.296 12.05 36.1 289.7 2050 575 245 56.5

YGFC-B DC SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (5.55/14.5 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 DC CB -3R-B 174 83 6.17 1.81 4.11 1.20 57.3 14.1 55.7 13.2 0.77 0.049 8.81 26.4 42 630 558 233 18 ISO 14001: 2015
YGFC 03 DC CB -3R-B 259 123 9.46 2.77 6.23 1.83 57 13.9 55.3 12.9 1.183 0.075 12.98 38.9 55.7 780 558 233 20.8 OHSAS 18001: 2007
H
YGFC 04 DC CB -3R-B 309 146 10.94 3.21 7.2 2.11 57 13.9 55.3 12.9 1.367 0.086 11.44 34.3 68 880 558 233 23.4
YGFC 05 DC CB -3R-B 390 185 13.09 3.84 8.82 2.59 58 14.4 56.2 13.4 1.637 0.103 10.26 30.7 98.7 930 558 233 24.9
YGFC 06 DC CB -3R-B 517 244 16.91 4.96 11.49 3.37 58.5 14.7 56.6 13.7 2.114 0.133 17.14 51.3 123.3 1030 558 233 27.4
YGFC 07 DC CB -3R-B 551 261 18.55 5.44 12.47 3.65 58 14.4 56.2 13.4 2.319 0.146 21.04 63.0 125.7 1200 558 233 36.3
YGFC 08 DC CB -3R-B 748 353 23.52 6.89 16.46 4.82 59.4 15.2 57.5 14.2 2.941 0.186 10.94 32.8 172.7 1400 558 233 38.7 L

YGFC 10 DC CB -3R-B 805 380 24.94 7.31 17.47 5.12 59.4 15.2 57.5 14.2 3.118 0.197 10.06 30.1 190.9 1450 558 233 40.3
YGFC 12 DC CB -3R-B 953 450 28 8.21 19.73 5.78 59.5 15.3 57.6 14.2 3.5 0.221 13.7 41.0 234.6 1700 558 233 45.8
YGFC 14 DC CB -3R-B 1265 597 36.75 10.77 26.35 7.72 60.2 15.7 58.2 14.6 4.594 0.290 14.01 41.9 305.6 1950 558 233 56.5

YDFC DC SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (5.55/14.5 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
H
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
ISO 9001:2015
YDFC 08 DC CB -3R 845 399 26.5 7.77 17.98 17.22 58.7 14.8 56.3 13.5 3.31 0.209 23.5 70.4 254.5 1050 775 295 36 ISO 14001: 2015
YDFC 10 DC CB -3R 1180 557 33.13 9.71 22.22 21.80 58.6 14.8 56.1 13.4 4.141 0.261 30.81 92.2 270.3 1210 775 295 38 OHSAS 18001: 2007
YDFC 12 DC CB -3R 1290 609 39.45 11.56 26.65 25.93 58.7 14.8 56.3 13.5 4.931 0.311 20.94 62.7 373.2 1210 775 345 45
YDFC 14 DC CB -3R 1576 744 43.04 12.62 30.11 30.38 59.8 15.4 57.3 14.1 5.38 0.339 13.74 41.1 458.9 1340 775 345 50 L
YDFC 16 DC CB -3R 1829 864 53.26 15.61 36.63 34.91 59.5 15.3 56.9 13.8 6.657 0.420 20.62 61.7 604.7 1340 815 396 61 w
YDFC 18 DC CB -3R 1924 908 57.83 16.95 39.62 38.79 59.1 15.1 56.7 13.7 7.229 0.456 24.13 72.2 648.1 1480 815 396 74
YDFC 20 DC CB -3R 2270 1072 62.08 18.20 44.02 44.50 60.1 15.6 57.6 14.2 7.76 0.490 23.44 70.2 756.6 1610 815 396 78

31
YORK® Chilled Water Fan Coil Units - Saudi/China Origins

High Δ T (16°F[8.9C]) - District Cooling Applications


YGFC DC SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 0 Pa
CHW WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP POWER INPUT WEIGHT
MODEL FLOW DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
YGFC 02 DC CE -4R 249 118 9.6 2.81 6.46 1.89 56.1 13.4 54.7 12.6 1.20 0.076 2.75 8.2 38.8 906 542 262 34.7
W ISO 9001:2015
ISO 14001: 2015
YGFC 03 DC CE -4R 337 160 14 4.10 9.06 2.66 55.2 12.9 53.6 12.0 1.75 0.110 5.93 17.8 52.5 1026 542 262 37.2
OHSAS 18001: 2007
YGFC 04 DC CE -4R 422 200 17.06 5.00 11.15 3.27 55.7 13.2 54.1 12.3 2.132 0.135 9.95 29.8 74.7 1147 542 262 41.1
YGFC 05 DC CE -4R 539 255 17.99 5.27 12.64 3.70 58.4 14.7 56.6 13.7 2.249 0.142 3.62 10.8 125.6 1168 542 262 43.8 H
YGFC 06 DC CE -4R 649 307 23.72 6.95 16.01 4.69 57.3 14.1 55.5 13.1 2.966 0.187 6.85 20.5 141.2 1388 542 262 48.4
YGFC 07 DC CE -4R 774 366 28.73 8.42 19.29 5.65 57.0 13.9 55.3 12.9 3.591 0.227 11.73 35.1 183.1 1510 542 262 55.9
YGFC 08 DC CE -4R 815 385 32.06 9.40 21.04 6.17 56.2 13.4 54.4 12.4 4.008 0.253 6.78 20.3 183.9 1630 542 262 62.5 L
YGFC 10 DC CE -4R 974 460 35.88 10.52 24.04 7.05 57.3 14.1 55.3 12.9 4.485 0.283 8.69 26.0 226.7 1750 542 262 64.2
YGFC 12 DC CE -4R 1151 544 43.27 12.68 28.64 8.39 57.1 13.9 55.1 12.8 5.409 0.341 12.47 37.3 252.8 1990 542 262 70.3
YGFC 14 DC CE -4R 1390 656 49.17 14.41 33.39 9.79 57.9 14.4 55.9 13.3 6.147 0.388 10.18 30.5 304.2 2230 542 262 84.2

YGFC DC SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 DC CB -4R 200 95 8.12 2.38 5.42 1.59 55.1 12.8 54 12.2 1.02 0.064 2.11 6.3 38.1 730 569 245 19 ISO 14001: 2015
YGFC 03 DC CB -4R 269 127 11.13 3.26 7.33 2.15 54.9 12.7 53.7 12.1 1.392 0.088 3.92 11.7 51.2 830 569 245 22.1 OHSAS 18001: 2007
H
YGFC 04 DC CB -4R 358 169 14.9 4.37 9.73 2.85 55 12.8 53.6 12.0 1.862 0.117 7.91 23.7 73.2 930 569 245 24.4
YGFC 05 DC CB -4R 471 223 15.89 4.66 11.23 3.29 58 14.4 56.4 13.6 1.986 0.125 2.62 7.8 121.9 1030 569 245 26
YGFC 06 DC CB -4R 576 272 20.88 6.12 14.26 4.18 57.2 14.0 55.6 13.1 2.61 0.165 5.44 16.3 138.8 1150 569 245 28.6
YGFC 08 DC CB -4R 702 332 28.02 8.21 18.48 5.42 55.7 13.2 54.2 12.3 3.503 0.221 5.47 16.4 180.7 1450 569 245 41.1
L
YGFC 10 DC CB -4R 862 407 32.14 9.42 21.64 6.34 56.9 13.8 55.2 12.9 4.017 0.253 7.29 21.8 222.3 1550 569 245 42.5
YGFC 12 DC CB -4R 1006 475 38.57 11.30 25.64 7.52 56.5 13.6 54.8 12.7 4.821 0.304 10.36 31.0 248.4 1750 569 245 47.7
YGFC 14 DC CB -4R 1218 575 44.09 12.92 30.01 8.80 57.3 14.1 55.6 13.1 5.511 0.348 8.58 25.7 297.5 2050 575 245 58.5

YGFC-B DC SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 DC CB -4R-B 199 94 8.12 2.38 5.27 1.54 54.3 12.4 53.4 11.9 1.01 0.064 15.1 45.2 47.2 630 558 233 19 ISO 14001: 2015
YGFC 03 DC CB -4R-B 291 138 12.15 3.56 7.91 2.32 54.5 12.5 53.6 12.0 1.519 0.096 29.9 89.5 62.3 780 558 233 22.1 OHSAS 18001: 2007
H
YGFC 04 DC CB -4R-B 346 164 13.98 4.10 9.12 2.67 54.6 12.6 53.7 12.1 1.748 0.110 14.96 44.8 78.4 880 558 233 24.4
YGFC 05 DC CB -4R-B 444 210 16.87 4.94 11.19 3.28 55.4 13.0 54.5 12.5 2.109 0.133 17.35 51.9 111.9 930 558 233 26
YGFC 06 DC CB -4R-B 610 288 21.3 6.24 14.46 4.24 56.4 13.6 55.4 13.0 2.663 0.168 16.12 48.3 143.4 1030 558 233 28.6
YGFC 07 DC CB -4R-B 638 302 24.54 7.19 16.28 4.77 55.5 13.1 54.5 12.5 3.067 0.194 22.06 66.0 145.4 1200 558 233 38.5
YGFC 08 DC CB -4R-B 824 389 31.6 9.26 20.94 6.14 55.5 13.1 54.5 12.5 3.95 0.249 15.79 47.3 200.4 1400 558 233 41.1 L

YGFC 10 DC CB -4R-B 891 421 30.89 9.05 21.54 6.31 57.3 14.1 56.3 13.5 3.862 0.244 15.24 45.6 216.4 1450 558 233 42.5
YGFC 12 DC CB -4R-B 1158 547 38.75 11.36 26.93 7.89 57.3 14.1 56.2 13.4 4.844 0.306 15.28 45.7 282.6 1700 558 233 47.7
YGFC 14 DC CB -4R-B 1467 693 47.77 14.00 33.48 9.81 57.6 14.2 56.5 13.6 5.971 0.377 18.54 55.5 359.2 1950 558 233 58.5

YDFC DC SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 50 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
H
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
ISO 9001:2015
YDFC 08 DC CB -4R 802 379 27.65 8.10 19.02 5.57 56.7 13.7 55.4 13.0 3.46 0.218 11.4 34.1 309.6 1050 775 295 49 ISO 14001: 2015
YDFC 10 DC CB -4R 1087 513 37.56 11.01 24.43 7.16 54.5 12.5 53.3 11.8 4.695 0.296 26.91 80.6 317.3 1210 775 295 51 OHSAS 18001: 2007
YDFC 12 DC CB -4R 1300 614 45.39 13.30 30.02 8.80 55.5 13.1 54.1 12.3 5.673 0.358 17.12 51.3 512.2 1210 775 345 59
YDFC 14 DC CB -4R 1568 740 52.33 15.34 35.28 10.34 56.4 13.6 54.9 12.7 6.541 0.413 13.66 40.9 551.6 1340 775 345 65 L
YDFC 16 DC CB -4R 1857 877 63.91 18.73 42.78 12.54 56.2 13.4 54.7 12.6 7.989 0.504 23 68.9 632.6 1340 815 396 77 w
YDFC 18 DC CB -4R 1935 914 70.76 20.74 46.8 13.72 55.6 13.1 54.2 12.3 8.845 0.558 30.91 92.5 721 1480 815 396 92
YDFC 20 DC CB -4R 2238 1057 76.38 22.39 51.68 15.15 56.5 13.6 55 12.8 9.547 0.602 17.98 53.8 925.8 1610 815 396 97

32
YORK® Chilled Water Fan Coil Units - Saudi/China Origins

High Δ T (16°F[8.9C]) - District Cooling Applications


YGFC DC SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - MEDIUM SPEED - 0 Pa
CHW WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP POWER INPUT WEIGHT
MODEL FLOW DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
W
YGFC 02 DC CE -4R 232 110 9.02 2.64 6.08 1.78 55.9 13.3 54.6 12.6 1.13 0.071 2.74 8.2 36.4 906 542 262 34.7 ISO 9001:2015
YGFC 03 DC CE -4R 304 144 12.78 3.75 8.3 2.43 54.8 12.7 53.4 11.9 1.597 0.101 4.95 14.8 49.6 1026 542 262 37.2 ISO 14001: 2015
OHSAS 18001: 2007
YGFC 04 DC CE -4R 384 182 15.73 4.61 10.29 3.02 55.3 12.9 53.8 12.1 1.966 0.124 8.55 25.6 65 1147 542 262 41.1
YGFC 05 DC CE -4R 488 231 16.36 4.80 11.55 3.39 58.2 14.6 56.5 13.6 2.044 0.129 3.23 9.7 115.9 1168 542 262 43.8 H
YGFC 06 DC CE -4R 591 279 21.97 6.44 14.8 4.34 56.9 13.8 55.2 12.9 2.747 0.173 6.09 18.2 127.9 1388 542 262 48.4
YGFC 07 DC CE -4R 704 333 27.05 7.93 18.01 5.28 56.4 13.6 54.8 12.7 3.382 0.213 10.55 31.6 169.3 1510 542 262 55.9
YGFC 08 DC CE -4R 750 354 30.09 8.82 19.73 5.78 55.8 13.2 54.1 12.3 3.762 0.237 6.24 18.7 170.9 1630 542 262 62.5 L
YGFC 10 DC CE -4R 903 427 34.11 10.00 22.73 6.66 56.8 13.8 55 12.8 4.264 0.269 8.1 24.3 213.8 1750 542 262 64.2
YGFC 12 DC CE -4R 1062 502 41.55 12.18 27.25 7.99 56.4 13.6 54.5 12.5 5.194 0.328 12.1 36.2 234.3 1990 542 262 70.3
YGFC 14 DC CE -4R 1263 597 45.85 13.44 31.02 9.09 57.4 14.1 55.5 13.1 5.731 0.362 9.65 28.9 291.3 2230 542 262 84.2

YGFC DC SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 DC CB -4R 187 89 7.72 2.26 5.12 1.50 54.8 12.7 53.7 12.1 0.96 0.061 2.11 6.3 35.2 730 569 245 19 ISO 14001: 2015
YGFC 03 DC CB -4R 248 118 10.87 3.19 7.03 2.06 53.9 12.2 52.8 11.6 1.358 0.086 3.43 10.3 48.2 830 569 245 22.1 OHSAS 18001: 2007
H
YGFC 04 DC CB -4R 327 155 13.68 4.01 8.95 2.62 54.7 12.6 53.5 11.9 1.711 0.108 6.98 20.9 63.3 930 569 245 24.4
YGFC 05 DC CB -4R 423 200 14.49 4.25 10.24 3.00 57.7 14.3 56.3 13.5 1.812 0.114 2.56 7.7 112.8 1030 569 245 26
YGFC 06 DC CB -4R 519 245 19.46 5.70 13.18 3.86 56.6 13.7 55.1 12.8 2.432 0.153 4.88 14.6 125 1150 569 245 28.6
YGFC 08 DC CB -4R 651 308 26.29 7.71 17.34 5.08 55.5 13.1 54.1 12.3 3.286 0.207 5.84 17.5 167.8 1450 569 245 41.1
L
YGFC 10 DC CB -4R 791 374 30.41 8.91 20.33 5.96 56.3 13.5 54.8 12.7 3.801 0.240 6.74 20.2 209.5 1550 569 245 42.5
YGFC 12 DC CB -4R 924 437 37.19 10.90 24.38 7.15 55.7 13.2 54.1 12.3 4.649 0.293 10.12 30.3 230.1 1750 569 245 47.7
YGFC 14 DC CB -4R 1093 516 40.54 11.88 27.5 8.06 56.8 13.8 55.3 12.9 5.067 0.320 7.92 23.7 284.1 2050 575 245 58.5

YGFC-B DC SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG W
ISO 9001:2015
YGFC 02 DC CB -4R-B 168 80 7.09 2.08 4.58 1.34 54 12.2 53.2 11.8 0.89 0.056 12.1 36.2 42 630 558 233 19 ISO 14001: 2015
YGFC 03 DC CB -4R-B 246 117 10.48 3.07 6.81 2.00 54.3 12.4 53.4 11.9 1.311 0.083 24.1 72.2 54.8 780 558 233 22.1 OHSAS 18001: 2007
H
YGFC 04 DC CB -4R-B 291 138 11.81 3.46 7.71 2.26 54.5 12.5 53.7 12.1 1.476 0.093 10.73 32.1 68.1 880 558 233 24.4
YGFC 05 DC CB -4R-B 374 177 14.71 4.31 9.71 2.85 55.1 12.8 54.2 12.3 1.839 0.116 14.05 42.1 98.3 930 558 233 26
YGFC 06 DC CB -4R-B 494 234 18.06 5.29 12.14 3.56 55.9 13.3 55 12.8 2.257 0.142 12.31 36.9 122.1 1030 558 233 28.6
YGFC 07 DC CB -4R-B 520 246 21.01 6.16 13.76 4.03 54.8 12.7 53.9 12.2 2.626 0.166 16.44 49.2 122.6 1200 558 233 38.5
YGFC 08 DC CB -4R-B 724 342 28.12 8.24 18.59 5.45 55.3 12.9 54.3 12.4 3.516 0.222 11.96 35.8 173.2 1400 558 233 41.1 L

YGFC 10 DC CB -4R-B 784 370 25.59 7.50 18.39 5.39 58 14.4 57.1 13.9 3.199 0.202 10.11 30.3 192 1450 558 233 42.5
YGFC 12 DC CB -4R-B 888 420 32.01 9.38 21.8 6.39 56.4 13.6 55.4 13.0 4.001 0.252 10.98 32.9 235.4 1700 558 233 47.7
YGFC 14 DC CB -4R-B 1193 564 41.07 12.04 28.29 8.29 56.9 13.8 55.9 13.3 5.133 0.324 15.12 45.3 302.3 1950 558 233 58.5

YDFC DC SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE DIMENSIONS
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT WEIGHT
MODEL DROP (MM)
H
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
ISO 9001:2015
YDFC 08 DC CB -4R 782 370 27.16 7.96 18.53 5.43 56.3 13.5 55 12.8 3.39 0.214 10.8 32.3 283.7 1050 775 295 49 ISO 14001: 2015
YDFC 10 DC CB -4R 1025 484 36.12 10.59 23.36 6.85 54.1 12.3 52.9 11.6 4.515 0.285 24.91 74.6 289.4 1210 775 295 51 OHSAS 18001: 2007
YDFC 12 DC CB -4R 1214 573 43.93 12.88 29.09 8.53 55.3 12.9 54 12.2 5.492 0.346 15.77 47.2 477.3 1210 775 345 59
YDFC 14 DC CB -4R 1504 710 50.02 14.66 33.76 9.90 56.2 13.4 54.8 12.7 6.253 0.395 12.96 38.8 520.2 1340 775 345 65 L
YDFC 16 DC CB -4R 1784 842 62.34 18.27 41.68 12.22 56.1 13.4 54.6 12.6 7.793 0.492 21.93 65.7 593.9 1340 815 396 77 w
YDFC 18 DC CB -4R 1839 868 67.45 19.77 44.61 13.08 55.4 13.0 54 12.2 8.431 0.532 28.58 85.6 663.2 1480 815 396 92
YDFC 20 DC CB -4R 2152 1016 74.51 21.84 50.13 14.69 56.1 13.4 54.8 12.7 9.314 0.588 17.19 51.5 868 1610 815 396 97

33
YORK® Chilled Water Fan Coil Units - Italy Origin

STD Δ T (10°F[5.56C]) - Standard Applications


YLH STD SERIES (DECORATIVE) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Laser-YLH-110-3R 148 70 3.34 0.98 3.10 0.91 59.9 15.5 59.9 15.5 0.665 0.042 0.8 2.3 58 648 623 224 18
W
Laser-YLH-112-3R 204 96 5.49 1.61 4.57 1.34 58.5 14.7 58.3 14.6 1.096 0.069 1.7 5.1 65 773 623 224 20
Laser-YLH-114-3R 269 127 8.26 2.42 6.38 1.87 57.4 14.1 57.2 14.0 1.647 0.104 1.6 4.7 82 898 623 224 23
Laser-YLH-216-3R 404 191 12.35 3.62 8.94 2.62 58.8 14.9 57.2 14.0 2.461 0.155 4.4 13.2 92 1023 623 224 28
Laser-YLH-218-3R 494 233 13.14 3.85 11.05 3.24 58.6 14.8 58.6 14.8 2.620 0.165 4.1 12.3 110 1148 623 224 31 H

Laser-YLH-220-3R 634 299 17.20 5.04 13.31 3.90 59.9 15.5 58.3 14.6 3.421 0.216 7.8 23.5 127 1273 699 254 41
Laser-YLH-222-3R 720 340 18.42 5.40 15.56 4.56 59.4 15.2 59.0 15.0 3.668 0.231 8.2 24.5 174 1273 699 254 44
Laser-YLH-224-3R 868 409 24.36 7.14 18.97 5.56 59.0 15.0 57.9 14.4 4.852 0.306 5.6 16.9 204 1523 699 254 52 L

Laser-YLH-226-3R 1013 478 27.47 8.05 21.29 6.24 59.9 15.5 58.3 14.6 5.468 0.345 6.6 19.8 248 1523 699 254 52
Laser-YLH-328-3R 1488 702 37.46 10.98 29.92 8.77 60.8 16.0 59.0 15.0 7.458 0.471 22.3 66.9 351 1773 699 254 60

YLIH STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 25 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Concealed-YLIH-110-3R 127 60 3.07 0.90 2.73 0.80 59.2 15.1 59.2 15.1 0.612 0.039 0.7 2.0 57 574 505 215 10 W
Concealed-YLIH-112-3R 181 86 5.02 1.47 4.16 1.22 58.1 14.5 58.1 14.5 1.004 0.063 1.4 4.3 63 699 505 215 13
Concealed-YLIH-114-3R 240 113 7.54 2.21 5.83 1.71 56.8 13.8 56.8 13.8 1.497 0.094 1.3 4.0 81 824 505 215 16
Concealed-YLIH-216-3R 361 170 11.40 3.34 8.29 2.43 58.1 14.5 56.8 13.8 2.272 0.143 3.8 11.4 89 949 505 215 19
H
Concealed-YLIH-218-3R 447 211 12.21 3.58 10.17 2.98 58.3 14.6 58.3 14.6 2.430 0.153 3.6 10.8 110 1074 505 215 22
Concealed-YLIH-220-3R 571 269 15.93 4.67 12.35 3.62 59.2 15.1 58.1 14.5 3.174 0.200 6.8 20.4 126 1199 581 245 29
Concealed-YLIH-222-3R 648 306 17.09 5.01 14.47 4.24 58.6 14.8 58.6 14.8 3.403 0.215 7.1 21.4 172 1199 581 245 31
Concealed-YLIH-224-3R 765 361 22.28 6.53 17.37 5.09 58.3 14.6 57.7 14.3 4.438 0.280 4.8 14.3 198 1449 581 245 38 L

Concealed-YLIH-226-3R 924 436 25.76 7.55 19.99 5.86 59.2 15.1 58.1 14.5 5.129 0.324 5.9 17.6 243 1449 581 245 38
Concealed-YLIH-328-3R 1427 674 36.40 10.67 29.14 8.54 60.4 15.8 58.8 14.9 7.247 0.457 21.2 63.5 339 1699 581 245 44

YEFB STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 50 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Blower-YEFB-020-3R 801 378 22.45 6.58 16.07 4.71 60.8 16.0 57.9 14.4 4.473 0.282 10.1 30.2 241 990 902 408 66
Blower-YEFB-030-3R 1386 654 28.56 8.37 22.52 6.60 64.4 18.0 60.4 15.8 5.688 0.359 16.0 47.9 521 990 902 408 66 H

Blower-YEFB-040-3R 1573 742 33.98 9.96 27.87 8.17 63.0 17.2 60.1 15.6 6.767 0.427 15.8 47.2 564 1240 902 408 82
Blower-YEFB-050-3R 1646 777 35.86 10.51 29.38 8.61 62.6 17.0 60.1 15.6 7.133 0.450 14.6 43.8 875 1240 902 408 82
Blower-YEFB-060-3R 2327 1098 63.83 18.71 48.65 14.26 59.9 15.5 58.1 14.5 12.711 0.802 8.5 25.5 1188 1635 1158 513 135 W
L
Blower-YEFB-070-3R 2899 1368 73.63 21.58 57.52 16.86 61.0 16.1 58.8 14.9 14.666 0.925 11.1 33.1 1796 1635 1158 513 135
* YEFB-070 will work on ESP 150Pa and higher in order to avoid overheating.

34
YORK® Chilled Water Fan Coil Units - Italy Origin

STD Δ T (10°F[5.56C]) - Standard Applications


YLH STD SERIES (DECORATIVE) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Laser-YLH-110-3R 118 56 2.90 0.85 2.56 0.75 59.4 15.2 59.2 15.1 0.581 0.037 0.6 1.7 48 648 623 224 18
W
Laser-YLH-112-3R 168 79 4.71 1.38 3.62 1.06 59.4 15.2 58.1 14.5 0.942 0.059 1.5 4.5 53 773 623 224 20
Laser-YLH-114-3R 233 110 6.35 1.86 5.29 1.55 58.3 14.6 58.3 14.6 1.264 0.080 1.2 3.7 65 898 623 224 23
Laser-YLH-216-3R 332 157 10.58 3.10 7.61 2.23 57.9 14.4 56.7 13.7 2.105 0.133 3.6 10.8 73 1023 623 224 28
Laser-YLH-218-3R 419 198 11.40 3.34 9.48 2.78 58.3 14.6 58.3 14.6 2.267 0.143 3.4 10.2 88 1148 623 224 31 H

Laser-YLH-220-3R 535 253 15.11 4.43 11.53 3.38 59.4 15.2 58.1 14.5 3.012 0.190 6.6 19.7 100 1273 699 254 41
Laser-YLH-222-3R 589 278 15.80 4.63 13.24 3.88 58.5 14.7 58.5 14.7 3.148 0.199 6.6 19.8 133 1273 699 254 44
Laser-YLH-224-3R 673 318 19.72 5.78 15.08 4.42 58.5 14.7 57.6 14.2 3.927 0.248 4.2 12.7 147 1523 699 254 52 L

Laser-YLH-226-3R 804 379 22.45 6.58 17.02 4.99 59.7 15.4 57.9 14.4 4.469 0.282 4.8 14.5 178 1523 699 254 52
Laser-YLH-328-3R 1050 496 29.48 8.64 23.47 6.88 58.6 14.8 58.1 14.5 5.873 0.371 16.5 49.5 251 1773 699 254 60

YLIH STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Concealed-YLIH-110-3R 98 46 2.63 0.77 2.22 0.65 58.3 14.6 58.3 14.6 0.524 0.033 0.5 1.4 46 574 505 215 10 W
Concealed-YLIH-112-3R 134 63 3.92 1.15 3.07 0.90 58.1 14.5 57.7 14.3 0.779 0.049 1.1 3.2 51 699 505 215 13
Concealed-YLIH-114-3R 201 95 5.56 1.63 4.57 1.34 58.1 14.5 58.1 14.5 1.110 0.070 1.0 2.9 65 824 505 215 16
Concealed-YLIH-216-3R 288 136 9.52 2.79 6.89 2.02 57.0 13.9 56.1 13.4 1.893 0.119 3.0 8.9 71 949 505 215 19
H
Concealed-YLIH-218-3R 361 170 10.17 2.98 8.32 2.44 57.9 14.4 57.9 14.4 2.021 0.128 2.8 8.3 87 1074 505 215 22
Concealed-YLIH-220-3R 460 217 13.51 3.96 10.37 3.04 58.3 14.6 57.4 14.1 2.695 0.170 5.4 16.1 99 1199 581 245 29
Concealed-YLIH-222-3R 498 235 14.02 4.11 11.46 3.36 57.9 14.4 57.9 14.4 2.791 0.176 5.3 15.9 132 1199 581 245 31
Concealed-YLIH-224-3R 566 267 17.30 5.07 13.34 3.91 57.4 14.1 57.0 13.9 3.447 0.218 3.4 10.1 144 1449 581 245 38 L

Concealed-YLIH-226-3R 709 334 20.47 6.00 15.59 4.57 59.0 15.0 57.7 14.3 4.081 0.258 4.1 12.2 174 1449 581 245 38
Concealed-YLIH-328-3R 999 472 28.49 8.35 22.69 6.65 58.3 14.6 57.9 14.4 5.671 0.358 15.5 46.5 243 1699 581 245 44

YEFB STD SERIES (DUCTED) - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Blower-YEFB-020-3R 476.2 225 15.73 4.61 11.12 3.26 57.6 14.2 56.1 13.4 3.135 0.198 5.0 14.9 137 990 902 408 66
Blower-YEFB-030-3R 721.6 341 19.82 5.81 15.25 4.47 59.7 15.4 58.1 14.5 3.949 0.249 8.1 24.4 269 990 902 408 66 H

Blower-YEFB-040-3R 1030 486 26.95 7.90 21.87 6.41 59.7 15.4 58.6 14.8 5.371 0.339 11.2 33.6 366 1240 902 408 82
Blower-YEFB-050-3R 1360 642 32.86 9.63 27.53 8.07 61.5 16.4 60.8 16.0 6.530 0.412 12.8 38.3 575 1240 902 408 82
Blower-YEFB-060-3R 1828 863 54.59 16.00 41.01 12.02 58.5 14.7 57.4 14.1 10.875 0.686 6.4 19.1 898 1635 1158 513 135 W
L
Blower-YEFB-070-3R 2631 1242 68.47 20.07 52.64 15.43 60.8 16.0 58.6 14.8 13.640 0.861 9.6 28.6 881 1635 1158 513 135
* YEFB-070 will work on ESP 150Pa and higher in order to avoid overheating.

35
YORK® Chilled Water Fan Coil Units - Italy Origin

STD Δ T (10°F[5.56C]) - Standard Applications


YLH STD SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Laser-YLH-110-4R 148 70 4.33 1.27 3.48 1.02 57.6 14.2 57.6 14.2 0.86 0.054 0.4 1.2 58 648 623 224 18
W
Laser-YLH-112-4R 204 96 6.04 1.77 4.81 1.41 57.4 14.1 57.4 14.1 1.20 0.076 1.0 3.0 65 773 623 224 20
Laser-YLH-114-4R 269 127 10.37 3.04 6.58 1.93 56.5 13.6 54.0 12.2 2.06 0.130 2.4 7.3 82 898 623 224 23
Laser-YLH-216-4R 404 191 13.34 3.91 10.03 2.94 56.1 13.4 56.1 13.4 2.66 0.168 2.3 7.0 92 1023 623 224 28
Laser-YLH-218-4R 494 233 15.25 4.47 11.87 3.48 57.0 13.9 57.0 13.9 3.04 0.192 2.5 7.4 110 1148 623 224 31 H

Laser-YLH-220-4R 634 299 19.52 5.72 15.22 4.46 57.0 13.9 57.0 13.9 3.89 0.245 3.8 11.5 127 1273 699 254 41
Laser-YLH-222-4R 720 340 21.05 6.17 16.89 4.95 57.6 14.2 57.6 14.2 4.19 0.264 5.9 17.6 174 1273 699 254 44
Laser-YLH-224-4R 868 409 29.68 8.7 21.94 6.43 55.8 13.2 55.8 13.2 5.91 0.373 4.1 12.3 204 1523 699 254 52 L

Laser-YLH-226-4R 1013 478 32.14 9.42 24.39 7.15 56.8 13.8 56.7 13.7 6.40 0.404 4.6 13.7 248 1523 699 254 52
Laser-YLH-328-4R 1488 702 44.32 12.99 35.18 10.31 57.4 14.1 57.2 14.0 8.83 0.557 9.1 27.1 351 1773 699 254 60

YLIH STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 25 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Concealed-YLIH-110-4R 127 60 4.03 1.18 3.10 0.91 56.7 13.7 56.7 13.7 0.80 0.051 0.4 1.1 57 574 505 215 10 W
Concealed-YLIH-112-4R 181 86 5.36 1.57 4.26 1.25 57.4 14.1 57.4 14.1 1.07 0.068 0.8 2.4 63 699 505 215 13
Concealed-YLIH-114-4R 240 113 9.45 2.77 6.04 1.77 55.9 13.3 53.8 12.1 1.88 0.119 2.1 6.2 81 824 505 215 16
Concealed-YLIH-216-4R 361 170 12.21 3.58 9.08 2.66 55.9 13.3 55.9 13.3 2.43 0.154 2.0 6.0 89 949 505 215 19
H
Concealed-YLIH-218-4R 447 211 13.95 4.09 10.82 3.17 56.8 13.8 56.8 13.8 2.78 0.175 2.1 6.3 110 1074 505 215 22
Concealed-YLIH-220-4R 571 269 17.98 5.27 13.85 4.06 56.7 13.7 56.7 13.7 3.58 0.226 3.3 9.9 126 1199 581 245 29
Concealed-YLIH-222-4R 648 306 19.41 5.69 15.35 4.5 57.2 14.0 57.2 14.0 3.87 0.244 5.0 15.1 172 1199 581 245 31
Concealed-YLIH-224-4R 765 361 26.92 7.89 19.65 5.76 55.4 13.0 55.4 13.0 5.36 0.338 3.4 10.3 198 1449 581 245 38 L

Concealed-YLIH-226-4R 924 436 29.96 8.78 22.82 6.69 56.3 13.5 56.3 13.5 5.97 0.377 4.0 12.1 243 1449 581 245 38
Concealed-YLIH-328-4R 1427 674 43.02 12.61 33.91 9.94 57.2 14.0 57.2 14.0 8.57 0.541 8.6 25.7 339 1699 581 245 44

YEFB STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 50 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Blower-YEFB-020-4R 801 378 25.90 7.59 18.90 5.54 57.4 14.1 56.5 13.6 5.16 0.326 5.6 16.8 241 990 902 408 66
Blower-YEFB-030-4R 1386 654 33.85 9.92 27.16 7.96 61.2 16.2 59.2 15.1 6.75 0.426 9.4 28.1 521 990 902 408 66 H

Blower-YEFB-040-4R 1573 742 40.29 11.81 33.47 9.81 59.5 15.3 58.8 14.9 8.02 0.506 9.3 27.7 564 1240 902 408 82
Blower-YEFB-050-4R 1573 777 42.61 12.49 35.38 10.37 59.0 15.0 59.0 15.0 8.48 0.535 8.6 25.8 875 1240 902 408 82
Blower-YEFB-060-4R 2327 1098 76.87 22.53 57.83 16.95 56.1 13.4 56.1 13.4 15.31 0.966 6.8 20.4 1188 1635 1158 513 135 W
L
Blower-YEFB-070-4R 2899 1368 88.06 25.81 69.12 20.26 57.2 14.0 57.2 14.0 17.54 1.107 8.7 26.1 1024 1635 1158 513 135
* YEFB-070 will work on ESP 150Pa and higher in order to avoid overheating.

36
YORK® Chilled Water Fan Coil Units - Italy Origin

STD Δ T (10°F[5.56C]) - Standard Applications


YLH STD SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Laser-YLH-110-4R 118 56 3.45 1.01 2.90 0.85 56.3 13.5 56.3 13.5 0.687 0.043 0.3 0.9 48 648 623 224 18
W
Laser-YLH-112-4R 168 79 4.44 1.30 3.96 1.16 57.4 14.1 57.2 14.0 0.885 0.056 0.6 1.8 53 773 623 224 20
Laser-YLH-114-4R 233 110 7.51 2.20 5.87 1.72 55.9 13.3 55.8 13.2 1.497 0.094 1.8 5.3 65 898 623 224 23
Laser-YLH-216-4R 332 157 10.41 3.05 8.46 2.48 55.6 13.1 55.6 13.1 2.074 0.131 1.7 5.1 73 1023 623 224 28
Laser-YLH-218-4R 419 198 12.04 3.53 10.27 3.01 56.5 13.6 56.3 13.5 2.400 0.151 1.7 5.0 88 1148 623 224 31 H

Laser-YLH-220-4R 535 253 16.07 4.71 13.34 3.91 56.1 13.4 56.1 13.4 3.201 0.202 2.8 8.3 100 1273 699 254 41
Laser-YLH-222-4R 589 278 17.30 5.07 14.53 4.26 56.3 13.5 56.3 13.5 3.447 0.218 4.1 12.3 133 1273 699 254 44
Laser-YLH-224-4R 673 318 22.93 6.72 17.84 5.23 54.7 12.6 54.5 12.5 4.570 0.288 2.6 7.7 147 1523 699 254 52 L

Laser-YLH-226-4R 804 379 25.25 7.40 20.30 5.95 55.8 13.2 55.8 13.2 5.028 0.317 3.0 8.9 178 1523 699 254 52
Laser-YLH-328-4R 1050 496 32.24 9.45 26.48 7.76 55.9 13.3 55.4 13.0 6.419 0.405 5.3 15.8 251 1773 699 254 60

YLIH STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Concealed-YLIH-110-4R 98 46 3.28 0.96 2.46 0.72 55.9 13.3 55.9 13.3 0.656 0.041 0.3 0.8 46 574 505 215 10 W
Concealed-YLIH-112-4R 134 63 3.89 1.14 3.14 0.92 57.6 14.2 57.6 14.2 0.775 0.049 0.5 1.4 51 699 505 215 13
Concealed-YLIH-114-4R 201 95 7.03 2.06 5.08 1.49 55.8 13.2 55.6 13.1 1.400 0.088 1.6 4.7 65 824 505 215 16
Concealed-YLIH-216-4R 288 136 9.83 2.88 7.27 2.13 55.8 13.2 55.8 13.2 1.955 0.123 1.5 4.6 71 949 505 215 19
H
Concealed-YLIH-218-4R 361 170 11.33 3.32 8.73 2.56 56.8 13.8 56.8 13.8 2.259 0.143 1.5 4.5 87 1074 505 215 22
Concealed-YLIH-220-4R 460 217 14.98 4.39 11.36 3.33 56.3 13.5 56.3 13.5 2.985 0.188 2.4 7.3 99 1199 581 245 29
Concealed-YLIH-222-4R 498 235 15.97 4.68 12.18 3.57 56.5 13.6 56.5 13.6 3.179 0.201 3.6 10.7 132 1199 581 245 31
Concealed-YLIH-224-4R 566 267 21.02 6.16 14.98 4.39 54.7 12.6 54.7 12.6 4.187 0.264 2.2 6.6 144 1449 581 245 38 L

Concealed-YLIH-226-4R 709 334 24.05 7.05 17.84 5.23 55.8 13.2 55.8 13.2 4.790 0.302 2.7 8.1 174 1449 581 245 38
Concealed-YLIH-328-4R 999 472 32.51 9.53 24.63 7.22 56.3 13.5 56.3 13.5 6.476 0.409 5.4 16.1 243 1699 581 245 44

YEFB STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Blower-YEFB-020-4R 476.2 225 17.50 5.13 12.52 3.67 54.9 12.7 54.9 12.7 3.483 0.220 2.6 7.8 137 990 902 408 66
Blower-YEFB-030-4R 721.6 341 22.72 6.66 17.50 5.13 56.7 13.7 56.7 13.7 4.522 0.285 4.5 13.4 269 990 902 408 66 H

Blower-YEFB-040-4R 1030 486 31.39 9.20 24.60 7.21 57.0 13.9 57.0 13.9 6.252 0.394 6.4 19.1 366 1240 902 408 82
Blower-YEFB-050-4R 1360 642 38.79 11.37 32.48 9.52 58.3 14.6 58.3 14.6 7.719 0.487 7.4 22.3 575 1240 902 408 82
Blower-YEFB-060-4R 1828 863 63.97 18.75 46.81 13.72 55.4 13.0 55.4 13.0 12.737 0.804 4.8 14.5 898 1635 1158 513 135 W
L
Blower-YEFB-070-4R 2631 1242 81.58 23.91 63.56 18.63 56.8 13.8 56.7 13.7 16.246 1.025 7.5 22.4 881 1635 1158 513 135
* YEFB-070 will work on ESP 150Pa and higher in order to avoid overheating.

37
YORK® Chilled Water Fan Coil Units - Italy Origin

STD Δ T (10°F[5.56C]) - Standard Applications


YLH STD SERIES (DECORATIVE) - ECM - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Laser-YLH-512-EST 3R (9V) 268 127 6.45 1.89 5.19 1.52 61.5 16.4 59.4 15.2 1.286 0.081 2.4 7.2 37 773 623 224 20 W

Laser-YLH-514-EST 3R (9V) 338 160 8.56 2.51 6.89 2.02 60.4 15.8 58.8 14.9 1.704 0.108 2.1 6.3 49 898 623 224 23

Laser-YLH-516-EST 3R (9V) 440 208 11.94 3.50 9.48 2.78 59.4 15.2 58.3 14.6 2.378 0.150 3.6 10.8 35 1023 623 224 28
H
Laser-YLH-520-EST 3R (9V) 596 281 15.83 4.64 12.38 3.63 60.1 15.6 58.5 14.7 3.152 0.199 4.0 12 40 1273 699 254 41

Laser-YLH-522-EST 3R (9V) 712 336 18.15 5.32 13.99 4.10 61.2 16.2 58.8 14.9 3.615 0.228 8.5 25.5 65 1273 699 254 44

Laser-YLH-524-EST 3R (9V) 853 403 23.06 6.76 17.91 5.25 59.9 15.5 58.3 14.6 4.592 0.290 4.1 12.4 77 1523 699 254 52 L

Laser-YLH-528-EST 3R (9V) 1099 519 28.83 8.45 22.52 6.60 60.4 15.8 57.9 14.4 5.741 0.362 7.4 22.1 138 1773 699 254 58

YLIH STD SERIES (DUCTED) - ECM - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 25 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Concealed-YLIH-512-EST 3R (9V) 263 124 6.35 1.86 5.08 1.49 61.5 16.4 59.4 15.2 1.264 0.080 2.0 6 52 699 505 215 13
W
Concealed-YLIH-514-EST 3R (9V) 333 157 8.26 2.42 6.62 1.94 61.0 16.1 59.4 15.2 1.642 0.104 1.6 4.9 65 824 505 215 16

Concealed-YLIH-516-EST 3R (9V) 443 209 11.87 3.48 9.55 2.80 59.4 15.2 58.6 14.8 2.364 0.149 3.4 10.2 81 949 505 215 19

Concealed-YLIH-520-EST 3R (9V) 533 251 14.33 4.20 11.22 3.29 59.7 15.4 59.4 15.2 2.857 0.180 3.5 10.4 44 1199 581 245 29 H

Concealed-YLIH-522-EST 3R (9V) 603 284 16.14 4.73 12.62 3.70 59.9 15.5 59.5 15.3 3.214 0.203 4.0 12 57 1199 581 245 31

Concealed-YLIH-524-EST 3R (9V) 783 369 22.07 6.47 16.92 4.96 59.4 15.2 58.6 14.8 4.394 0.277 3.7 11.2 89 1449 581 245 38
L
Concealed-YLIH-528-EST 3R (9V) 951 449 26.03 7.63 20.37 5.97 59.5 15.3 58.8 14.9 5.182 0.327 6.1 18.3 128 1699 581 245 42

YEFB STD SERIES (DUCTED) - ECM - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 50 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Blower-YEFB-020-EST 3R (9V) 842 397 22.62 6.63 15.32 4.49 62.6 17.0 61.7 16.5 4.504 0.284 8.0 24 185 990 902 408 66
H
Blower-YEFB-030-EST 3R (9V) 1166 550 26.65 7.81 20.20 5.92 63.5 17.5 62.6 17.0 5.305 0.335 13.3 39.8 232 990 902 408 66

Blower-YEFB-040-EST 3R (9V) 1759 830 36.54 10.71 28.52 8.36 64.4 18.0 63.0 17.2 7.278 0.459 15.5 46.3 383 1240 902 408 82

Blower-YEFB-050-EST 3R (9V) 2220 1048 43.98 12.89 37.19 10.90 64.0 17.8 63.7 17.6 8.757 0.553 21.2 63.6 617 1240 902 408 82 W
L
Blower-YEFB-060-EST 3R (9V) 2535 1196 67.66 19.83 51.48 15.09 60.6 15.9 60.4 15.8 13.473 0.850 9.5 28.4 762 1635 1158 513 135

38
YORK® Chilled Water Fan Coil Units - Italy Origin

STD Δ T (10°F[5.56C]) - Standard Applications


YLH STD SERIES (DECORATIVE) - ECM - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Laser-YLH-512-EST 3R (8V) 237 112 5.90 1.73 4.71 1.38 61.0 16.1 59.0 15.0 1.176 0.074 1.9 5.7 26 773 623 224 20 W

Laser-YLH-514-EST 3R (8V) 298 141 7.85 2.30 6.35 1.86 59.7 15.4 58.5 14.7 1.563 0.099 1.9 5.8 36 898 623 224 23

Laser-YLH-516-EST 3R (8V) 403 190 11.02 3.23 8.70 2.55 59.2 15.1 58.1 14.5 2.197 0.139 3.2 9.5 28 1023 623 224 28
H
Laser-YLH-520-EST 3R (8V) 542 256 14.70 4.31 11.26 3.30 60.1 15.6 58.3 14.6 2.928 0.185 3.6 10.7 32 1273 699 254 41

Laser-YLH-522-EST 3R (8V) 656 310 17.02 4.99 13.03 3.82 61.0 16.1 58.6 14.8 3.395 0.214 7.5 22.4 52 1273 699 254 44

Laser-YLH-524-EST 3R (8V) 780 368 21.56 6.32 16.55 4.85 59.7 15.4 58.1 14.5 4.297 0.271 3.7 11 60 1523 699 254 52 L

Laser-YLH-528-EST 3R (8V) 993 469 26.82 7.86 21.08 6.18 59.7 15.4 58.3 14.6 5.341 0.337 6.9 20.7 106 1773 699 254 58

YLIH STD SERIES (DUCTED) - ECM - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Concealed-YLIH-512-EST 3R (8V) 219 103 5.56 1.63 4.47 1.31 60.4 15.8 58.6 14.8 1.11 0.070 1.6 4.7 38 699 505 215 13
W
Concealed-YLIH-514-EST 3R (8V) 297 140 7.54 2.21 6.18 1.81 60.1 15.6 59.5 15.3 1.51 0.095 1.5 4.4 48 824 505 215 16

Concealed-YLIH-516-EST 3R (8V) 383 181 10.61 3.11 8.46 2.48 58.8 14.9 57.6 14.2 2.11 0.133 2.7 8.2 36 949 505 215 19

Concealed-YLIH-520-EST 3R (8V) 454 214 12.69 3.72 9.89 2.90 59.0 15.0 57.7 14.3 2.53 0.159 2.8 8.4 33 1199 581 245 29 H

Concealed-YLIH-522-EST 3R (8V) 496 234 13.92 4.08 10.85 3.18 59.0 15.0 58.8 14.9 2.77 0.175 3.1 9.3 44 1199 581 245 31

Concealed-YLIH-524-EST 3R (8V) 671 317 19.38 5.68 14.88 4.36 58.8 14.9 57.6 14.2 3.86 0.244 3.0 9.1 64 1449 581 245 38
L
Concealed-YLIH-528-EST 3R (8V) 830 392 23.61 6.92 18.59 5.45 58.5 14.7 57.7 14.3 4.70 0.297 5.5 16.4 95 1699 581 245 42

YEFB STD SERIES (DUCTED) - ECM - 3 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Blower-YEFB-020-EST 3R (8V) 647 306 18.83 5.52 12.83 3.76 61.0 16.1 60.8 16.0 3.75 0.237 5.7 17.2 126 990 902 408 66
H
Blower-YEFB-030-EST 3R (8V) 865 408 21.84 6.4 16.62 4.87 61.7 16.5 61.2 16.2 4.35 0.274 9.2 27.6 165 990 902 408 66

Blower-YEFB-040-EST 3R (8V) 1504 710 33.03 9.68 25.86 7.58 63.5 17.5 61.3 16.3 6.57 0.415 12.9 38.5 270 1240 902 408 82

Blower-YEFB-050-EST 3R (8V) 1919 906 40.16 11.77 33.98 9.96 63.0 17.2 60.8 16.0 8.00 0.505 18.0 53.9 435 1240 902 408 82 W
L
Blower-YEFB-060-EST 3R (8V) 2095 989 55.92 16.39 45.41 13.31 59.2 15.1 58.6 14.8 11.13 0.703 7.5 22.5 507 1635 1158 513 135

39
YORK® Chilled Water Fan Coil Units - Italy Origin

STD Δ T (10°F[5.56C]) - Standard Applications


YLH STD SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Laser-YLH-512-EST 4R (9V) 268 127 7.37 2.16 6.11 1.79 58.1 14.5 57.6 14.2 1.47 0.093 1.6 4.7 37 773 623 224 20 W

Laser-YLH-514-EST 4R (9V) 338 160 11.09 3.25 7.64 2.24 58.5 14.7 57.7 14.3 2.21 0.139 2.7 8.2 49 898 623 224 23

Laser-YLH-516-EST 4R (9V) 440 208 14.50 4.25 10.92 3.2 56.3 13.5 56.3 13.5 2.88 0.182 2.6 7.9 35 1023 623 224 28
H
Laser-YLH-520-EST 4R (9V) 596 281 18.46 5.41 14.16 4.15 57.2 14 57.2 14.0 3.67 0.232 2.2 6.5 40 1273 699 254 41

Laser-YLH-522-EST 4R (9V) 712 336 20.88 6.12 16.48 4.83 57.7 14.3 57.6 14.2 4.16 0.263 2.7 8.2 65 1273 699 254 44

Laser-YLH-524-EST 4R (9V) 853 403 27.60 8.09 20.81 6.1 56.7 13.7 56.3 13.5 5.50 0.347 1.0 2.9 77 1523 699 254 52 L

Laser-YLH-528-EST 4R (9V) 1099 519 33.30 9.76 26.20 7.68 57.2 14 56.8 13.8 6.63 0.419 5.8 17.3 138 1773 699 254 58

YLIH STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 25 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Concealed-YLIH-512-EST 4R (9V) 263 124 7.23 2.12 6.00 1.76 58.1 14.5 57.6 14.2 1.44 0.091 1.5 4.6 52 699 505 215 13
W
Concealed-YLIH-514-EST 4R (9V) 333 157 10.95 3.21 7.54 2.21 58.3 14.6 57.7 14.3 2.18 0.138 2.7 8 65 824 505 215 16

Concealed-YLIH-516-EST 4R (9V) 443 209 14.26 4.18 10.88 3.19 56.5 13.6 56.5 13.6 2.84 0.179 2.7 8 81 949 505 215 19

Concealed-YLIH-520-EST 4R (9V) 533 251 17.64 5.17 13.00 3.81 56.7 13.7 55.8 13.2 3.51 0.222 1.8 5.5 44 1199 581 245 29 H

Concealed-YLIH-522-EST 4R (9V) 603 284 18.39 5.39 14.40 4.22 57.0 13.9 56.3 13.5 3.66 0.231 2.2 6.5 57 1199 581 245 31

Concealed-YLIH-524-EST 4R (9V) 783 369 25.79 7.56 19.45 5.7 56.1 13.4 56.1 13.4 5.14 0.324 0.9 2.6 89 1449 581 245 38
L
Concealed-YLIH-528-EST 4R (9V) 951 449 29.82 8.74 23.03 6.75 56.8 13.8 55.8 13.2 5.94 0.375 4.7 14.2 128 1699 581 245 42

YEFB STD SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - HIGH SPEED - 50 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Blower-YEFB-020-EST 4R (9V) 842 397 26.13 7.66 19.52 5.72 57.7 14.3 57.6 14.2 5.20 0.328 5.9 17.6 185 990 902 408 66
H
Blower-YEFB-030-EST 4R (9V) 1166 550 31.32 9.18 24.19 7.09 60.1 15.6 58.1 14.5 6.24 0.394 7.7 23 232 990 902 408 66

Blower-YEFB-040-EST 4R (9V) 1759 830 43.57 12.77 34.43 10.09 61.3 16.3 59.0 15.0 8.68 0.548 9.2 27.4 383 1240 902 408 82

Blower-YEFB-050-EST 4R (9V) 2220 1048 52.92 15.51 45.27 13.27 60.4 15.8 58.6 14.8 10.54 0.665 12.8 38.3 617 1240 902 408 82 W
L
Blower-YEFB-060-EST 4R (9V) 2535 1196 80.35 23.55 61.96 18.16 56.5 13.6 55.8 13.2 16.00 1.010 7.4 22.1 762 1635 1158 513 135

40
YORK® Chilled Water Fan Coil Units - Italy Origin

STD Δ T (10°F[5.56C]) - Standard Applications


YLH STD SERIES (DECORATIVE) - ECM - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Laser-YLH-512-EST 4R (8V) 237 112 6.62 1.94 5.42 1.59 57.9 14.4 57.6 14.2 1.32 0.083 1.3 3.9 26 773 623 224 20 W

Laser-YLH-514-EST 4R (8V) 298 141 10.06 2.95 6.96 2.04 57.7 14.3 57.2 14.0 2.00 0.126 2.4 7.1 36 898 623 224 23

Laser-YLH-516-EST 4R (8V) 403 190 13.41 3.93 10.03 2.94 56.1 13.4 55.9 13.3 2.67 0.168 2.3 6.8 28 1023 623 224 28
H
Laser-YLH-520-EST 4R (8V) 542 256 17.88 5.24 12.90 3.78 57.2 14 57.2 14.0 3.56 0.225 1.9 5.7 32 1273 699 254 41

Laser-YLH-522-EST 4R (8V) 656 310 19.38 5.68 15.28 4.48 57.7 14.3 56.8 13.8 3.86 0.244 2.4 7.3 52 1273 699 254 44

Laser-YLH-524-EST 4R (8V) 780 368 25.73 7.54 19.41 5.69 56.1 13.4 56.1 13.4 5.12 0.323 0.8 2.5 60 1523 699 254 52 L

Laser-YLH-528-EST 4R (8V) 993 469 31.22 9.15 24.09 7.06 56.8 13.8 56.7 13.7 6.22 0.392 5.4 16.1 106 1773 699 254 58

YLIH STD SERIES (DUCTED) - ECM - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Concealed-YLIH-512-EST 4R (8V) 219 103 6.18 1.81 5.05 1.48 57.9 14.4 57.0 13.9 1.23 0.078 1.1 3.4 38 699 505 215 13
W
Concealed-YLIH-514-EST 4R (8V) 297 140 10.00 2.93 6.93 2.03 57.7 14.3 57.2 14.0 1.99 0.126 2.4 7.1 48 824 505 215 16

Concealed-YLIH-516-EST 4R (8V) 383 181 12.90 3.78 9.62 2.82 55.9 13.3 55.8 13.2 2.57 0.162 2.1 6.3 36 949 505 215 19

Concealed-YLIH-520-EST 4R (8V) 454 214 15.46 4.53 11.26 3.3 56.1 13.4 55.9 13.3 3.08 0.194 1.5 4.4 33 1199 581 245 29 H

Concealed-YLIH-522-EST 4R (8V) 496 234 15.52 4.55 12.01 3.52 56.8 13.8 55.8 13.2 3.10 0.195 1.6 4.9 44 1199 581 245 31

Concealed-YLIH-524-EST 4R (8V) 671 317 22.86 6.7 16.92 4.96 55.8 13.2 55.8 13.2 4.55 0.287 0.7 2 64 1449 581 245 38
L
Concealed-YLIH-528-EST 4R (8V) 830 392 27.19 7.97 20.54 6.02 56.3 13.5 55.9 13.3 5.42 0.342 4.2 12.6 95 1699 581 245 42

YEFB STD SERIES (DUCTED) - ECM - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 45/55°F (7.22/12.78 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
Blower-YEFB-020-EST 4R (8V) 647 306 21.46 6.29 16.14 4.73 56.1 13.4 55.9 13.3 4.27 0.269 4.1 12.3 126 990 902 408 66
H
Blower-YEFB-030-EST 4R (8V) 865 408 25.25 7.4 19.65 5.76 58.3 14.6 56.8 13.8 5.03 0.318 5.2 15.5 165 990 902 408 66

Blower-YEFB-040-EST 4R (8V) 1504 710 39.13 11.47 30.95 9.07 60.3 15.7 57.2 14.0 7.79 0.492 7.5 22.5 270 1240 902 408 82

Blower-YEFB-050-EST 4R (8V) 1919 906 48.04 14.08 41.08 12.04 59.5 15.3 57.6 14.2 9.57 0.604 10.7 32.1 435 1240 902 408 82 W
L
Blower-YEFB-060-EST 4R (8V) 2095 989 65.78 19.28 50.77 14.88 56.8 13.8 56.7 13.7 13.10 0.826 5.7 17.2 507 1635 1158 513 135

41
YORK® Chilled Water Fan Coil Units - Italy Origin

High Δ T (16°F[8.9C]) - District Cooling Applications


YLH DC SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
W
Laser-YLH-220-4R 634 299 20.91 6.13 15.76 4.62 56.1 13.4 56.1 13.4 2.571 0.162 6.5 19.4 127 1273 699 254 41

Laser-YLH-222-4R 720 340 22.11 6.48 16.85 4.94 57.6 14.2 57.0 13.9 2.721 0.172 7.0 21.1 174 1273 699 254 44

H
Laser-YLH-224-4R 868 409 27.57 8.08 21.02 6.16 56.8 13.8 56.7 13.7 3.390 0.214 5.7 17.2 204 1523 699 254 52

Laser-YLH-226-4R 1013 478 29.72 8.71 22.76 6.67 58.5 14.7 57.6 14.2 3.654 0.231 10.1 30.2 248 1523 699 254 52
L
Laser-YLH-328-4R 1488 702 43.26 12.68 33.16 9.72 58.6 14.8 57.7 14.3 5.323 0.336 15.9 47.6 351 1773 699 254 60

YLIH DC SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 25 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG

Concealed-YLIH-220-4R 571 269 19.34 5.67 14.36 4.21 55.9 13.3 55.9 13.3 2.382 0.150 5.6 16.9 126 1199 581 245 29 W

Concealed-YLIH-222-4R 648 306 20.47 6.00 15.63 4.58 56.8 13.8 56.7 13.7 2.518 0.159 6.1 18.3 172 1199 581 245 31
H

Concealed-YLIH-226-4R 924 436 27.81 8.15 21.32 6.25 57.9 14.4 57.4 14.1 3.421 0.216 8.9 26.7 243 1449 581 245 38

Concealed-YLIH-328-4R 1427 674 42.03 12.32 32.24 9.45 58.3 14.6 57.4 14.1 5.169 0.326 15.1 45.2 339 1699 581 245 44 L

YEFB DC SERIES (DUCTED) - 4 & 5 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - HIGH SPEED - 50 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG

Blower DC-YEFB-020-4R 801 378 25.28 7.41 19.04 5.58 57.2 14.0 57.2 14.0 3.108 0.196 10.6 31.6 241 990 902 408 66
H
Blower DC-YEFB-030-4R 1386 654 34.29 10.05 27.47 8.05 61.0 16.1 60.8 16.0 4.218 0.266 18.4 55.1 521 990 902 408 66

Blower DC-YEFB-040-4R 1573 742 41.49 12.16 33.13 9.71 59.7 15.4 59.4 15.2 5.107 0.322 14.5 43.4 564 1240 902 408 82
W
L
Blower DC-YEFB-060-5R 2327 1098 88.57 25.96 62.37 18.28 54.3 12.4 54.3 12.4 10.897 0.688 9.9 29.5 1188 1635 1158 513 135

Blower DC-YEFB-070-5R 2899 1368 93.62 27.44 66.94 19.62 57.9 14.4 56.5 13.6 11.521 0.727 10.5 31.4 1224 1635 1158 513 135

42
YORK® Chilled Water Fan Coil Units - Italy Origin

High Δ T (16°F[8.9C]) - District Cooling Applications


YLH DC SERIES (DECORATIVE) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - MEDIUM SPEED - 0 Pa
WATER PRESSURE
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW POWER INPUT DIMENSIONS (MM) WEIGHT
MODEL DROP
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG
W
Laser-YLH-220-4R 535 253 18.56 5.44 13.65 4 55.6 13.1 55.4 13.0 2.281 0.144 5.7 17.2 100 1273 699 254 41

Laser-YLH-222-4R 589 278 18.90 5.54 14.33 4.2 56.7 13.7 55.8 13.2 2.325 0.147 5.9 17.8 133 1273 699 254 44

H
Laser-YLH-224-4R 673 318 22.35 6.55 16.79 4.92 56.1 13.4 55.6 13.1 2.752 0.174 4.6 13.7 147 1523 699 254 52

Laser-YLH-226-4R 804 379 25.04 7.34 19.07 5.59 57.2 14 56.8 13.8 3.082 0.194 8.0 24 178 1523 699 254 52
L
Laser-YLH-328-4R 1050 496 32.41 9.50 24.91 7.3 57.2 14 56.8 13.8 3.989 0.252 10.5 31.4 251 1773 699 254 60

YLIH DC SERIES (DUCTED) - 4 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - MEDIUM SPEED - 25 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG

Concealed-YLIH-220-4R 460 217 16.51 4.84 11.94 3.50 55.0 12.8 55.0 12.8 2.03 0.128 4.7 14 99 1199 581 245 29 W

Concealed-YLIH-222-4R 498 235 16.68 4.89 12.45 3.65 55.9 13.3 55.9 13.3 2.05 0.129 4.7 14.1 132 1199 581 245 31
H

Concealed-YLIH-226-4R 709 334 22.82 6.69 17.40 5.10 56.5 13.6 56.5 13.6 2.81 0.177 6.7 20.2 174 1449 581 245 38

Concealed-YLIH-328-4R 999 472 31.25 9.16 24.02 7.04 57.0 13.9 56.8 13.8 3.85 0.243 9.9 29.5 243 1699 581 245 44 L

YEFB DC SERIES (DUCTED) - 4 & 5 ROWS - 80/67°F (26.7 /19.44 C) @ CHW TEMP 42/58°F (5.55/14.5 C) - MEDIUM SPEED - 50 Pa
WATER PRESSURE POWER
AIR FLOW COOLING CAPACITY OFF COIL TEMP CHW FLOW DIMENSIONS (MM) WEIGHT
MODEL DROP INPUT
CFM LPS TMBH TKW SMBH SKW DB °F DB °C WB °F WB °C US GPM LPS FT.WG KPA WATTS L W H KG

Blower DC-YEFB-020-4R 476 225 17.06 5.00 12.35 3.62 55.2 12.9 55.2 12.9 2.096 0.132 5.1 15.4 137 990 902 408 66
H
Blower DC-YEFB-030-4R 722 341 22.55 6.61 17.43 5.11 56.8 13.8 56.8 13.8 2.774 0.175 8.6 25.6 269 990 902 408 66

Blower DC-YEFB-040-4R 1030 486 30.30 8.88 23.61 6.92 58.1 14.5 57.6 14.2 3.725 0.235 8.2 24.7 366 1240 902 408 82
W
L
Blower DC-YEFB-060-5R 1829 863 72.47 21.24 50.15 14.7 53.8 12.1 53.8 12.1 8.990 0.567 6.8 20.4 898 1635 1158 513 135

Blower DC-YEFB-070-5R 2632 1242 87.62 25.68 62.27 18.25 57.4 14.1 57.2 14.0 10.778 0.680 9.2 27.5 981 1635 1158 513 135

43
YORK® YLIH/YEFB Fan Coils with EC Motors - Energy Saving Technology by Al Salem Johnson Controls

EST – Energy Saving Technology is achieved by using ECM- Electronically Commutated Motor (ECM)
ECM technology consists of a brushless motor combined to a dedicated electronic device (inverter), a magnet rotor. The controller uses a
modulating signal with 0-10Vdc tension in order to regulate the fan speed.

Power Consumption
ECM FCUs v.s. Conventional PSC FCUs

900 Motor Control

YORK - YEFB-EST-60
900

YORK - YEFB-EST-60
YORK Model - YLIH-EST-528
YORK Model - YEFB-EST-30
Motor
YORK Model - YLIH-EST-514

YORK - YEFB-EST-50
YORK Model - YLIH-EST-520

YORK Model - YLIH-EST-524


750
Power Consumption- Watt

YORK Model - YLIH-EST-512

YORK Model - YLIH-EST-528


YORK Model - YEFB-EST-30
YORK Model - YLIH-EST-514

YORK - YEFB-EST-50
YORK Model - YLIH-EST-520

YORK Model - YLIH-EST-524


750
Power Consumption- Watt

YORK Model - YLIH-EST-512

Permeant
600 Magnet Rotor
600
450
450
300
300
150
150
0
0 150 300 450 550 750 1000 1250 1800
Convention 150
634 300
299 450
20.91 550
6.13 750
15.76 1000
4.62 1250
56.1 1800
13.4
Convention 51 71 99 144 269 242 573 898
Convention PSC
PSC 51
720 71
340 99
22.11 144
6.48 269
16.85 242
4.94 573
57.6 898
14.2
PSC
York
York
YORK ECM 23
868 47
409 34
27.57 50
8.08 111
21.02 104
6.16 218
56.8 360
13.8
ECM 23 47 34 50 111 104 218 360
ECM
Air Flow- CFM
Air Flow- CFM Low Continuous
Energy saving: mechanical Longer regulation
electrical resistance expected of the fan
absorption and low lifetime of the speeds

40% 5% reduced overheating motor (0-100%)

Average Average Extremely quiet


Higher efficiency:
Saving in reduction in possibility to adapt the air
Reduced functioning
wearing of the unit,
Power Sound Level volume and the capacities
accordingly to the real
and higher due to the
reliability operation at
room loads low revolutions

44
AIR COOLED
PACKAGED AND
CONDENSING
UNITS
YORK® R410A Air Cooled Packaged Units - Saudi Origin

ZH PREDATOR Series - Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


AIR FLOW
MODEL WEIGHT ESP RANGE ELECTRIC HEATER EER - T1 DIMENSIONS (MM)
RATE RANGE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY TOTAL CAPACITY

PIN NUMBER LBS CFM PA OPTION 1 OPTION 2 BTU/H/W KW MBH KW MBH HXWXL

ZH090a E0 A2 A 11 910 1875-3800 50-500 9.0 KW/1Stage 18 KW/2Stage 11.60 28.6 97.7 23.5 80.3 1067 x 1499 x 2261

ZHD102 E0 A2 A 11 1426 2000-4200 50-500 9.0 KW/1Stage 18 KW/2Stage 12.10 31.7 108.0 26.0 88.7 1295 x1524 x 2464

ZHD120 E0 A2 A 11 1446 2400-5000 50-500 9.0 KW/1Stage 18 KW/2Stage 11.60 38.5 131.5 32.6 111.4 1295 x1524 x 2464

*Power supply can be 220V or 400V or 460V / 3Ph / 60Hz


*Total Gross Capacity

YORK® Predator® units are convertible single packages with a common footprint cabinet Models. All 6-1/2 through 10 ton
units have two compressors with independent refrigeration circuits to provide 2 stages of cooling. These units are de-
signed for light commercial applications and can be easily installed on a roof curb, slab, or frame.

Features and Benefits


Simplicity® Smart Equipment™ Control—The new generation of UPG control
is provided as a standard component on the Predator™ packaged unit that
provides the reliability and ease of use found in the Simplicity® Smart
Equipment™ line of controls.

Installation time and costs are reduced by easy power and control wiring.
All units are factory-wired, piped, charged and tested prior to shipment.
Factory-installed options further reduce installation costs.
Heat exchangers use corrosion-resistant, aluminized steel tubular
construction for durability and long service life.
Permanently lubricated condenser and evaporator fan motor bearings need
no annual maintenance.

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

46
YORK® R410A Air Cooled Packaged Units - Saudi Origin

DEH STELLAR Micro Series - Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


AIR FLOW INDOOR AIR DRY INDOOR AIR DRY DIMENSIONS
MODEL WEIGHT ESP RANGE ELECTRIC HEATER EER - T1
RATE RANGE BULB / WET BULB BULB / WET BULB (MM)
TEMPERATURE TEMPERATURE
80.6/66.2°F (27/19°C) 84.2/66.2°F (29/19°C)
TOTAL CAPACITY TOTAL CAPACITY

PIN NUMBER LBS CFM PA OPTION 1 OPTION 2 BTU/H/W KW MBH KW MBH HXWXL

DEH036 C02 A5 A 11 904 900-1500 50-250 5 KW/1Stage - 12.90 11.2 38.3 9.6 32.9 934 x 1193 x 1346
DEH048 C02 A5 A 11 973 1200-2000 50-250 5 KW/1Stage - 11.60 14.5 49.4 12.9 43.9 934 x 1193 x 1346
DEH060 C02 A5 A 11 1395 1350-2700 50-250 5 KW/1Stage - 11.50 17.8 60.7 15.4 52.7 1207 x 1186 x 1745
DEH072 C02 A5 A 11 1197 1400-2680 50-250 5 KW/1Stage 9 KW/1Stage 11.7 21.1 72.0 18.8 64.0 1207 x 1193 x 1750
* Power supply can be 230V / 1Ph / 60Hz
* Total Gross Capacity

DEH STELLAR Medium Series - Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


AIR FLOW INDOOR AIR DRY INDOOR AIR DRY DIMENSIONS
MODEL WEIGHT ESP RANGE ELECTRIC HEATER EER - T1
RATE RANGE BULB / WET BULB BULB / WET BULB (MM)
TEMPERATURE TEMPERATURE
80.6/66.2°F (27/19°C) 84.2/66.2°F (29/19°C)
TOTAL CAPACITY TOTAL CAPACITY

PIN NUMBER LBS CFM PA OPTION 1 OPTION 2 BTU/H/W KW MBH KW MBH HXWXL

DEH150 C02 A2 A 11 1539 4000-5500 50-500 18 KW/2Stage 36 KW/2Stage 11.25 44.3 151.3 38.7 132.1 1321 x 2121 x 2327
DEH190 C02 A2 A 11 1749 4500-7100 62.5-500 18 KW/2Stage 36 KW/2Stage 11.15 55.6 189.8 48.0 163.8 1488 x 2235 x 3350
DEH220 C02 A2 A 11 1757 5500-8500 62.5-500 18 KW/2Stage 36 KW/2Stage 11.20 62.4 213.1 50.9 173.6 1488 x 2235 x 3350
DEH250 C02 A2 A 11 1821 6500-9750 62.5-500 18 KW/2Stage 36 KW/2Stage 10.85 74.4 254.0 60.8 207.7 1488 x 2235 x 3350
DEH300 C02 A2 A 11 2174 7500-11250 62.5-562.5 18 KW/2Stage 36 KW/2Stage 10.30 87.4 298.3 73.6 251.1 1488 x 2235 x 3350
DEH340 C02 A2 A 11 2200 8000-12500 62.5-562.5 18 KW/2Stage 36 KW/2Stage 10.00 96.7 330.1 81.9 279.6 1488 x 2235 x 3350
DEH360 C02 A2 A 11 2200 9000-13500 62.5-562.5 18 KW/2Stage 36 KW/2Stage 10.30 103.5 353.3 90.3 308.4 1488 x 2235 x 3350
* Power supply can be 220V or 400V or 460V / 3Ph / 60Hz
* Total Gross Capacity
Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

47
YORK® R410A Air Cooled Packaged Units - Saudi Origin

DEH STELLAR Major Series - Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


AIR FLOW INDOOR AIR DRY INDOOR AIR DRY DIMENSIONS
MODEL WEIGHT ESP RANGE ELECTRIC HEATER EER - T1
RATE RANGE BULB / WET BULB BULB / WET BULB (MM)
TEMPERATURE TEMPERATURE
80.6/66.2°F (27/19°C) 84.2/66.2°F (29/19°C)
TOTAL CAPACITY TOTAL CAPACITY

PIN NUMBER LBS CFM PA OPTION 1 OPTION 2 BTU/H/W KW MBH KW MBH HXWXL

DEH420 C02 A211 A 11 3630 9400-15400 62.5-625 36 KW/2Stage 54 KW/2Stage 10.20 127.8 436.0 112.8 385.1 1981 x 2337 x 5588
DEH480 C02 A211 A 11 3720 12000-16000 62.5-625 36 KW/2Stage 54 KW/2Stage 10.50 137.2 468.2 124.1 423.4 1981 x 2337 x 5588
DEH600 C02 A211 A 11 4150 13000-19000 62.5-625 36 KW/2Stage 54 KW/2Stage 10.15 176.0 600.7 156.2 532.9 1981 x 2337 x 5588
* Power supply can be 220V or 400V or 460V / 3Ph / 60Hz
* Total Gross Capacity

DEH STELLAR Mega Series - Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


AIR FLOW INDOOR AIR DRY INDOOR AIR DRY DIMENSIONS
MODEL WEIGHT ESP RANGE ELECTRIC HEATER EER - T1
RATE RANGE BULB / WET BULB BULB / WET BULB (MM)
TEMPERATURE TEMPERATURE
80.6/66.2°F (27/19°C) 84.2/66.2°F (29/19°C)
TOTAL CAPACITY TOTAL CAPACITY

PIN NUMBER LBS CFM PA OPTION 1 OPTION 2 BTU/H/W KW MBH KW MBH HXWXL

DEH780 C02 A211 A 11 6790 17000-24000 150-650 54 KW/2Stage 72 KW/2Stage 9.80 236 805.4 204 697.7 2245 x 2294 x 6882
DEH900 C02 A211 A 11 7196 19500-28000 150-650 54 KW/2Stage 72 KW/2Stage 9.70 274 936.4 255 870.7 2245 x 2294 x 7233
DEH1080 C02 A211 A 11 8360 21500-30000 250-750 54 KW/2Stage 72 KW/2Stage 9.70 305 1041.3 267 910.5 2435 x 2294 x 8432
DEH1200 C02 A211 A 11 9288 25000-36000 250-750 54 KW/2Stage 72 KW/2Stage 9.77 362 1236.7 308 1050.6 2740 x 2294 x 8948
* Power supply can be 230V or 400V or 460V / 3Ph / 60Hz
* Total Gross Capacity

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

48
YORK® R410A Total Fresh Air - Air Cooled Packaged Units - Saudi Origin

100% Total Fresh Air DEH STELLAR Series - Quick Selection Guide
AIR FLOW
MODEL WEIGHT ESP RANGE ELECTRIC HEATER DIMENSIONS (MM)
RATE RANGE

PIN NUMBER KG CFM PA OPTION 1 OPTION 2 HXWXL

DEH150TFA 2028 1500-3125 50-500 18 KW/2Stage 36 KW/2Stage 1455 x 2235 x 2640


DEH190TFA 2831 1900-3958 50-500 18 KW/2Stage 36 KW/2Stage 1619 x 2235 x 4536
DEH250TFA 2881 2500-5208 50-500 18 KW/2Stage 36 KW/2Stage 1619 x 2235 x 4536
DEH300TFA 3320 3000-6250 50-500 18 KW/2Stage 36 KW/2Stage 1619 x 2235 x 4536
DEH340TFA 3349 3400-7083 50-625 18 KW/2Stage 36 KW/2Stage 1619 x 2235 x 4536
DEH360TFA 3349 3600-7500 50-625 18 KW/2Stage 36 KW/2Stage 1619 x 2235 x 4536
DEH420TFA 3461 4200-8750 50-625 18 KW/2Stage 36 KW/2Stage 1930 x 2235 x 5603
DEH480TFA 3571 4800-10000 50-625 18 KW/2Stage 36 KW/2Stage 1930 x 2235 x 5603
DEH600TFA 4012 6000-12500 50-625 18 KW/2Stage 36 KW/2Stage 1930 x 2235 x 5603

* Power supply can be 220V or 400V or 460V / 3Ph / 60Hz


* These models mentioned above is out of scope from the energy efficiency standard (SASO 2874/2016) & based on that we have the notification letter from
SASO for each model

Features:
- Double skin construction
- Hot gas bypass
- PVC Moisture Eliminator
- 2” Aluminum washable filter
- Bag filter 85% eff.
- Row split deign with two DX-Cooling Coil
- The controls by thermostat on ambient &
suction line temperatures
- The rest of options & SQ’ as per DEH Medium
& Major series

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

49
YORK® R410A Air Cooled Packaged Units - Saudi Origin

DEM Medium Series - Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


AIR FLOW
MODEL WEIGHT ESP RANGE ELECTRIC HEATER EER - T1 DIMENSIONS (MM)
RATE RANGE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)

TOTAL CAPACITY TOTAL CAPACITY

PIN NUMBER LBS CFM PA OPTION 1 OPTION 2 BTU/H/W KW MBH KW MBH HXWXL

DEM230 C02 A2 A11 1668 4500-7100 62.5-500 18 KW/2Stage 36 KW/2Stage 11.00 55.1 188.0 49.8 170.1 1529 x 2235 x 3351

DEM290 C02 A2 A11 1741 6500-9750 62.5-500 18 KW/2Stage 36 KW/2Stage 10.50 74.5 254.3 65.7 224.3 1529 x 2235 x 3351

DEM350 C02 A2 A11 2002 7500-11250 62.5-562.5 18 KW/2Stage 36 KW/2Stage 10.35 87.3 298.0 78.5 268.0 1529 x 2235 x 3351

DEM410 C02 A2 A11 2025 9000-13500 62.5-562.5 18 KW/2Stage 36 KW/2Stage 10.05 103.1 352.0 94.2 321.5 1529 x 2235 x 3351

* Power supply can be 220V or 400V or 460V / 3Ph / 60Hz


* Total Gross Capacity

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

50
YORK® R410A Air Cooled Condensing Units - Saudi Origin

DCH STELLAR Mini & Medium - Quick Selection Guide


COOLING PERFORMANCE DATA

NUMBER OF
NUMBER OF RATING @ ARI CONDITIONS
MODEL WEIGHT REFRIGERANT DIMENSIONS (MM)
COMPRESSORS AMBIENT 95°F (35°C) & SST. 45°F (7.2°C)
SERIES CIRCUITS

EER TOTAL CAPACITY TOTAL POWER INPUT

PIN NUMBER LBS # # BTU/H/W KW MBH KW HXWXL

DCH078 C02 2 A 11 639 2 2 13.35 23.1 79.0 5.91 1065 x 682 x 1582
DCH090 C02 2 A 11 639 2 2 13.2 26.4 90.0 6.81 1065 x 682 x 1582
Mini DCH102 C02 2 A 11 789 2 2 13.25 29.9 102.0 7.69 1271 x 862 x 1582
DCH120 C02 2 A 11 826 2 2 12.8 35.7 122.0 9.52 1271 x 862 x 1582
DCH150 C02 2 A 11 1117 2 2 10.95 43.4 148.0 13.52 1326 x 1119 x 2226

DCH190 C02 2 A 11 1485 2 2 12.70 55.6 189.7 15.0 1961 x 2215 x 1179
DCH220 C02 2 A 11 1485 2 2 12.70 60.2 205.6 16.2 1961 x 2215 x 1179
DCH250 C02 2 A 11 1540 2 2 12.30 67.8 231.5 18.8 1961 x 2215 x 1179
MEDIUM
DCH300 C02 2 A 11 1650 2 2 12.1 87.1 297.3 24.5 1961 x 2215 x 1179
DCH340 C02 2 A 11 1650 2 2 11.2 93.3 318.4 28.6 1961 x 2215 x 1179
DCH360 C02 2 A 11 1650 2 2 12.4 99.4 339.1 27.1 1961 x 2215 x 1179
*Power supply can be 220V or 400V or 460V / 3Ph / 60Hz

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

51
YORK® R410A Air Cooled Condensing Units - Saudi Origin

DCH STELLAR Major & Mega - Quick Selection Guide


COOLING PERFORMANCE DATA

NUMBER OF
NUMBER OF RATING @ ARI CONDITIONS
MODEL WEIGHT REFRIGERANT DIMENSIONS (MM)
COMPRESSORS AMBIENT 95°F (35°C) & SST. 45°F (7.2°C)
SERIES CIRCUITS

EER TOTAL CAPACITY TOTAL POWER INPUT

PIN NUMBER LBS # # BTU/H/W KW MBH KW HXWXL

DCH420 C02 2 A 11 2571 3 3 10.95 126.2 430.7 39.3 1922 x 2372 x 2220
MAJOR DCH480 C02 2 A 11 2571 3 3 11.79 129.6 442.3 37.5 1922 x 2372 x 2220
DCH600 C02 2 A 11 2884 4 4 11.93 175.7 599.6 50.2 1922 x 2372 x 2220

DCH780 C02 1 A 11 3814 3 3 12.05 226 770 64.0 1772 x 2294 x 3559
DCH900 C02 1 A 11 4277 3 3 11.63 273 932 80.1 1772 x 2294 x 559
MEGA
DCH1080 C02 1 A 11 4764 4 4 12.15 307 1047 86.2 1772 x 2294 x 4740
DCH1200 C02 1 A 11 5280 4 4 1.61 362 1237 106.6 1772 x 2294 x 4740
*Power supply can be 220V or 400V or 460V / 3Ph / 60Hz

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

52
RESIDENTIAL
& LIGHT
COMMERCIAL
UNITS
YORK® DX-High Wall Type Split Units - TAURUS Super Cool

R410A 60Hz High Wall Type Split Units Quick Selection Guide
OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


SPLIT AIR FLOW
MODEL FAN EER - T1 DIMENSIONS (MM) - W X H X D
UNIT RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY
COOLING ONLY
SET MODEL TYPE SPEED M3/HR CFM BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT

YE8HA18 / YE8SD18 1130 665 11.9 5.1 17.5 3.7 12.5 4.5 15.3 3.9 13.2 315 x 1185 x 231 650 x 870 x 320

YE8HA24 / YE8SD24 1200 706 12.0 6.7 22.8 4.8 16.3 5.7 19.6 4.9 16.9 315 x 1185 x 231 800 x 1000 x 415
Hi-Wall Hi
YE8HB28 / YE8SD28 1400 824 11.9 7.6 26.0 5.4 18.5 6.4 22.0 5.5 18.9 346 x 1286 x 262 800 x 1000 x 415

YE8HB32 / YE8SD32 1600 941 11.85 8.4 28.8 6.0 20.5 7.3 24.8 6.2 21.3 346 x 1286 x 262 800 x 1000 x 415

HEAT PUMP
YE8HA18 / YE8SD18 1130 665 11.9 5.1 17.5 3.7 12.5 4.5 15.3 3.9 13.2 315 x 1185 x 231 650 x 870 x 320

YE8HA24 / YE8SD24 1200 706 12.0 6.7 22.8 4.8 16.3 5.7 19.6 4.9 16.9 315 x 1185 x 231 800 x 1000 x 415
Hi-Wall Hi
YE8HB28 / YE8SD28 1400 824 11.9 7.6 26.0 5.4 18.5 6.4 22.0 5.5 18.9 346 x 1286 x 262 800 x 1000 x 415

YE8HB32 / YE8SD32 1600 941 11.85 8.4 28.8 6.0 20.5 7.3 24.8 6.2 21.3 346 x 1286 x 262 800 x 1000 x 415

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

54
YORK® DX-High Wall Type Split Units - ICEBERG

R410A 60Hz High Wall Type Split Units Quick Selection Guide
OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


SPLIT AIR FLOW
MODEL FAN EER - T1 DIMENSIONS (MM) - W X H X D
UNIT RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY
COOLING ONLY
SET MODEL TYPE SPEED M3/HR CFM BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT

YHFE12 / YHFE12 660 388 12.35 3.36 11.5 2.64 9.02 2.91 9.9 2.74 9.31 850 x 270 x 202 810 x 585 x 280

YHFE18 / YHFE18 1200 710 12.4 5.28 18 4.12 14.06 4.47 15.3 4.21 14.41 1131 x 315 x 230 860 x 650 x 310
Hi-Wall Hi
YHFE24 / YHFE24 1200 710 12.4 6.45 22 5.03 17.16 5.58 19 5.23 17.82 1131 x 315 x 230 885 x 795 x 366

YHFE30 / YHFE30 1500 882 12.3 7.95 27.2 6.21 21.24 6.75 23 6.34 21.59 1280 x 367 x 266 885 x 795 x 366

HEAT PUMP
YHGE12 / YHGE12 660 388 12.35 3.36 11.5 2.61 8.94 2.91 9.9 2.73 9.3 850 x 270 x 202 810 x 585 x 280

YHGE18 / YHGE18 1200 710 12.4 5.28 18 4.11 14.01 4.47 15.3 4.18 14.29 1131 x 315 x 230 860 x 650 x 310
Hi-Wall Hi
YHGE24 / YHGE24 1200 710 12.4 6.45 22 5.04 17.18 5.58 19 5.24 17.85 1131 x 315 x 230 885 x 795 x 366

YHGE30 / YHGE30 1500 882 12.3 7.95 27.2 6.2 21.22 6.75 23 6.35 21.65 1280 x 367 x 266 885 x 795 x 366

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

55
YORK® DX-High Wall DC Inverter Split Units - ICEBERG

R410A 60Hz High Wall DC-Inverter Split Units Quick Selection Guide
OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


SPLIT AIR FLOW
MODEL FAN EER - T1 DIMENSIONS (MM) - W X H X D
UNIT RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY
COOLING ONLY
SET MODEL TYPE SPEED M3/HR CFM BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT

YHJE18 / YHJE18 1000 588 13.0 5.2 17.9 5.1 17.4 4.6 15.6 4.3 14.6 960 x 315 x 230 860 x 650 x 310
Hi-Wall Hi
YHJE24 / YHJE24 1200 706 13.0 6.8 23.1 5.3 18.1 6.0 20.6 5.7 19.4 1131 x 315 x 235 885 x 795 x 366

HEAT PUMP
YHKE18 / YHKE18 1000 588 13.0 5.1 17.5 4.0 13.7 4.4 15.1 4.2 14.2 960 x 315 x 230 860 x 650 x 310
Hi-Wall Hi
YHKE24 / YHKE24 1200 706 12.95 6.8 23.1 5.3 18.0 5.9 20.1 5.5 18.9 1131 x 315 x 235 885 x 795 x 366

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

56
YORK® DX-High Wall Type Split Units - FROST

R410A 60Hz High Wall Type Split Units Quick Selection Guide
OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


SPLIT AIR FLOW
MODEL FAN EER - T1 DIMENSIONS (MM) - W X H X D
UNIT RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY
COOLING ONLY
SET MODEL TYPE SPEED M3/HR CFM BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT

YJFE18 / YJFE18 1200 706 12.15 5.3 18.0 3.8 12.8 4.5 15.3 3.8 13.2 997 x 322 x 230 890 x 697 x 353
YJFE24 / YJFE24 Hi-Wall Hi 1350 795 12.15 6.5 22.0 4.6 15.7 5.6 19.0 4.8 16.3 1115 x 336 x 248 890 x 697 x 353
YJFE28 / YJFE28 1500 883 12 8.1 27.4 5.7 19.5 6.8 23.2 5.8 19.9 1316 x 365 x 275 920 x 762 x 385

HEAT PUMP
YJGE18 / YJGE18 1200 706 12.15 5.3 18.0 3.8 12.8 4.5 15.3 3.8 13.2 997 x 322 x 230 890 x 697 x 353
YJGE24 / YJGE24 Hi-Wall Hi 1350 795 12.15 6.5 22.0 4.6 15.7 5.6 19.0 4.8 16.3 1115 x 336 x 248 890 x 697 x 353
YJGE28 / YJGE28 1500 883 12 8.1 27.4 5.7 19.5 6.8 23.2 5.8 19.9 1316 x 365 x 275 920 x 762 x 385

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

57
YORK® DX-Cassette Split Units - TAURUS Super Cool

R410A 60Hz Cassette Split Units Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


SPLIT AIR FLOW
MODEL FAN ESP EER - T1 DIMENSIONS (MM) - W X H X D
UNIT RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY
COOLING ONLY
SET MODEL TYPE SPEED M3/HR CFM PA IN.WG BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT

YE8CT18 / YE8SD18 1200 706 - - 11.9 5.0 17.1 3.6 12.2 4.4 15.0 3.8 12.9 265 x 900 x 900 650 x 870 x 320
YE8CT24 / YE8SD24 1200 706 - - 12.0 6.5 22.2 4.6 15.8 5.7 19.6 4.9 16.9 265 x 900 x 900 800 x 1000 x 415
Cassette Hi
YE8CT28 / YE8SD28 1700 1000 - - 12.0 7.9 27.0 5.6 19.3 7.0 24.0 6.0 20.6 292 x 900 x 900 800 x 1000 x 415
YE8CT32 / YE8SD32 1700 1000 - - 11.85 8.5 29.0 6.1 20.7 7.5 25.6 6.4 22.0 292 x 900 x 900 800 x 1000 x 415

HEAT PUMP
YE8CT18 / YE8SD18 1200 706 - - 11.9 5.0 17.1 3.6 12.2 4.4 15.0 3.8 12.9 265 x 900 x 900 650 x 870 x 320
YE8CT24 / YE8SD24 1200 706 - - 12.0 6.5 22.2 4.6 15.8 5.7 19.6 4.9 16.9 265 x 900 x 900 800 x 1000 x 415
Cassette Hi
YE8CT28 / YE8SD28 1700 1000 - - 12.0 7.9 27.0 5.6 19.3 7.0 24.0 6.0 20.6 292 x 900 x 900 800 x 1000 x 415
YE8CT32 / YE8SD32 1700 1000 - - 11.85 8.5 29.0 6.1 20.7 7.5 25.6 6.4 22.0 292 x 900 x 900 800 x 1000 x 415

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

58
YORK® DX-Cassette Type Split Units

R410A 60Hz Cassette Split Units Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


SPLIT AIR FLOW
MODEL FAN EER - T1 DIMENSIONS (MM) - W X H X D
UNIT RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY
COOLING ONLY
SET MODEL TYPE SPEED M3/HR CFM BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT

YKFN18 / YUFN18 1000 588 12.2 5.3 18 4.4 15.1 4.5 15.3 4.1 13.9 840 x 248 x 840 860 x 650 x 310
YKFN24 / YUFN24 1400 824 13.0 7.3 25 6.2 21 6.5 22.1 5.8 19.9 840 x 248 x 840 950 x 340 x 840
Cassette Hi
YKFN36 / YUFN36 2000 1176 12.4 10.0 34.2 8.4 28.7 8.7 29.8 7.9 27.1 840 x 298 x 840 950 x 1050 x 340
YKFN48 / YUFN48 2100 1195 12.11 12.7 43.3 10.7 36.4 10.3 35.1 9.4 32 840 x 298 x 840 950 x 1386 x 340

HEAT PUMP
YKGN18 / YUGN18 1000 588 12.2 5.3 18 4.4 15.1 4.5 15.3 4.1 13.9 840 x 248 x 840 860 x 650 x 310
YKGN24 / YUGN24 1400 824 13.0 7.3 25 6.2 21 6.5 22.1 5.8 19.9 840 x 248 x 840 950 x 340 x 840
Cassette Hi
YKGN36 / YUGN36 2000 1176 12.4 10.0 34.2 8.4 28.7 8.7 29.8 7.9 27.1 840 x 298 x 840 950 x 1050 x 340
YKGN48 / YUGN48 2100 1195 12.11 12.7 43.3 10.7 36.4 10.3 35.1 9.4 32 840 x 298 x 840 950 x 1386 x 340

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

59
YORK® DX- Free/Floor Standing Type Split Units

R410A 60Hz Free/Floor Standing Split Units Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


AIR FLOW
MODEL SPLIT UNIT FAN EER - T1 DIMENSIONS (MM) - W X H X D
RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY

COOLING ONLY - TAURUS SUPER COOL


SET MODEL TYPE SPEED M3/HR CFM BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT

YE8FT55 / YE8SD55 Free Standing Hi 2200 1294 11.8 14.9 51.0 - - 2.9 10.0 - - 629 x 1935 x 456 1000 x 1335 x 415

COOLING ONLY - COLUMN TROPICAL


YLFE55 / YLFE55 Free Standing Hi 2480 1459 11.9 15.3 52.4 - - 13.4 45.8 - - 629 x 1935 x 456 952 x 1333 x 415

60
YORK® DX-Ducted Residential Split Units - Saudi/China Origins

R410A 60Hz JCH Split Units Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


SPLIT AIR FLOW
MODEL FAN ESP EER - T1 DIMENSIONS (MM) - W X H X D
UNIT RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY
COOLING ONLY
SET MODEL TYPE SPEED M3/HR CFM PA IN.WG BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT

YEFN18 / YUFN18 1000 588 0-80 0-0.32 12.1 5.3 18 4.4 15.1 4.5 15.3 4.1 13.9 900 x 270 x 720 860 x 650 x 310
YEFN24 / YUFN24 1450 853 0-80 0-0.32 12.3 6.9 23.4 5.8 19.7 6.0 20.6 5.5 18.8 900 x 270 x 720 950 x 340 x 840
YGFN30 / YUFN30 1850 1088 0-120 0-0.48 12.5 9.1 31 7.6 26 7.8 26.7 7.0 24 1300 x 350 x 800 885 x 795 x 366
Ducted Hi
YGFN36 / YUFN36 2160 1270 0-120 0-0.48 11.9 10.1 34.6 8.5 29.1 8.3 28.4 7.6 25.9 1300 x 350 x 800 950 x 1050 x 340
YGFN48 / YUFN48 2600 1529 0-120 0-0.48 11.9 13.5 46 11.3 38.6 11.5 39.2 10.5 35.7 1300 x 350 x 800 950 x 1386 x 340
YGFN60 / YUFN60 3300 1941 0-150 0-0.60 12.2 17.0 58 14.3 48.7 14.9 51 13.6 46.4 1400 x 420 x 858 950 x 1386 x 340

HEAT PUMP
YEGN18 / YUGN18 1000 588 0-80 0-0.32 12.1 5.3 18 4.4 15.1 4.5 15.3 4.1 13.9 900 x 270 x 720 860 x 650 x 310
YEGN24 / YUGN24 1450 853 0-80 0-0.32 12.3 6.9 23.4 5.8 19.7 6.0 20.6 5.5 18.8 900 x 270 x 720 950 x 340 x 840
YGGN30 / YUGN30 1850 1088 0-120 0-0.48 12.5 9.1 31 7.6 26 7.8 26.7 7.0 24 1300 x 350 x 800 885 x 795 x 366
Ducted Hi
YGGN36 / YUGN36 2160 1270 0-120 0-0.48 11.9 10.1 34.6 8.5 29.1 8.3 28.4 7.6 25.9 1300 x 350 x 800 950 x 1050 x 340
YGGN48 / YUGN48 2600 1529 0-120 0-0.48 11.9 13.5 46 11.3 38.6 11.5 39.2 10.5 35.7 1300 x 350 x 800 950 x 1386 x 340
YGGN60 / YUGN60 3300 1941 0-150 0-0.60 12.2 16.7 57 14.0 47.9 14.7 50.2 13.4 45.6 1400 x 420 x 858 950 x 1386 x 340

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

61
YORK® DX-Ducted Light Commercial Split Units - Bahrain Origin

R410A 60Hz TAURUS Split Units Quick Selection Guide


OUTDOOR AIR DRY BULB TEMPERATURE

95°F (35°C) - T1 115°F (46°C) - T3


SPLIT AIR FLOW
MODEL FAN ESP EER - T1 DIMENSIONS (MM) - W X H X D
UNIT RATE INDOOR AIR DRY BULB / WET BULB INDOOR AIR DRY BULB / WET BULB
TEMPERATURE 80.6/66.2°F (27/19°C) TEMPERATURE 84.2/66.2°F (29/19°C)
TOTAL CAPACITY SENSIBLE CAPACITY TOTAL CAPACITY SENSIBLE CAPACITY
COOLING ONLY
SET MODEL TYPE SPEED M3/HR CFM PA IN.WG BTU/H/W KW MBH KW MBH KW MBH KW MBH INDOOR UNIT OUTDOOR UNIT
YE7EU072 / YE7CE072 1.13 2400 49.77 0.2 11.2 21.4 73 18.0 61 19.9 68 18.1 62 1071 x 1342 x 605 10590 x 918 x 945
YE7EU090 / YE7CE090 1.42 3000 62.21 0.25 11.2 25.5 87 21.4 73 22.9 78 20.9 71 1364 x 1528 x 760 1157 x 1950 x 1348
YE7EU120 / YE7CE120 1.89 4000 74.65 0.3 11.2 35.1 120 29.5 101 31.6 108 28.8 98 1364 x 1528 x 760 1157 x 1950 x 1348
YE7EU150 / YE7CE150 2.36 5000 74.65 0.3 11.0 43.9 150 36.9 126 38.7 132 35.2 120 1603 x 2158 x 940 1157 x 1950 x 1348
Ducted Hi
YE7EU180 / YE7CE180 2.83 6000 99.54 0.4 11.0 52.7 180 44.3 151 43.9 150 40.0 137 2000 x 2156 x 940 2023 x 1119 x 1373
YE7EU220 / YE7CE220 3.30 7000 99.54 0.4 11.0 64.4 220 54.1 185 55.7 190 50.6 173 2000 x 2156 x 940 2185 X 2037 X 1469
YE7EU250 / YE7CE250 3.78 8000 99.54 0.4 10.0 72.1 246 60.5 207 66.8 228 60.8 207 2000 X 2156 X 940 2185 X 2037 X 1649
YE7EU300 / YE7CE300 4.01 8500 99.54 0.4 10.0 79.1 270 66.4 227 67.4 230 61.3 209 2000 X 2156 X 940 2185 X 2037 X 1649
HEAT PUMP
YE7EU072 / YE7CE072 1.13 2400 49.77 0.2 11.3 20.8 71 17.5 59.6 19.0 65 17.3 59.2 1071 x 1342 x 605 10590 x 918 x 945
YE7EU090 / YE7CE090 1.42 3000 62.21 0.25 11.2 25.2 86 21.2 72.2 22.6 77 20.5 70.1 1364 x 1528 x 760 1157 x 1950 x 1348
YE7EU120 / YE7CE120 1.89 4000 74.65 0.3 11.2 35.1 120 29.5 100.8 31.6 108 28.8 98.3 1364 x 1528 x 760 1157 x 1950 x 1348
YE7EU150 / YE7CE150 2.36 5000 74.65 0.3 11.1 42.8 146 35.9 122.6 38.1 130 34.7 118.3 1603 x 2158 x 940 1157 x 1950 x 1348
Ducted Hi
YE7EU180 / YE7CE180 2.83 6000 99.54 0.4 11.0 51.6 176 43.3 147.8 43.9 150 40.0 136.5 2000 x 2156 x 940 2023 x 1119 x 1373
YE7EU220 / YE7CE220 3.30 7000 99.54 0.4 11.0 64.4 220 54.1 184.8 58.6 200 53.3 182.0 2000 x 2156 x 940 2185 X 2037 X 1469
YE7EU250 / YE7CE250 3.78 8000 99.54 0.4 10.0 72.1 246 60.5 206.6 63.9 218 58.1 198.4 2000 X 2156 X 940 2185 X 2037 X 1649
YE7EU300 / YE7CE300 4.01 8500 99.54 0.4 10.0 81.4 278 68.4 233.5 71.5 244 65.0 222.0 2000 X 2156 X 940 2185 X 2037 X 1649

62
YORK® Mini VRF High Ambient System Heat Pump R410A

Mini VRF Outdoor Units Quick Selection Guide


COOLING*1 COOLING*2 HEATING*1 OUTDOOR UNIT
MAX.
MODEL POWER SUPPLY INDOOR AMBIENT TEMP.
POWER POWER POWER DIMENSION NET/GROSS
CAPACITY CAPACITY CAPACITY UNITS
INPUT INPUT INPUT (W*H*D) WEIGHT
EER EER COP
PIN NUMBER V-PH-HZ KW KW KW KW KW KW MM KG PIECE °C

YV2VYH004HAS-DAX 380~415 - 3 - 50/60HZ 12.70 3.17 4.01 11.20 3.77 2.97 14.30 3.24 4.42 950/1340/370 115 / 123 8 Cooling: -5°C-52°CDB | Heating: -20°C-27°CDB

YV2VYH005HAS-DAX 380~415 - 3 - 50/60HZ 14.10 3.58 3.95 12.60 4.25 2.96 16.20 3.79 4.26 950/1340/370 115 / 123 10 Cooling: -5°C-52°CDB | Heating: -20°C-27°CDB

YV2VYH006HAS-DAX 380~415 - 3 - 50/60HZ 15.70 4.40 3.56 14.00 5.22 2.68 18.20 4.48 4.06 950/1340/370 115 / 123 13 Cooling: -5°C-52°CDB | Heating: -20°C-27°CDB

*1 AHRI1230 Testing condition is:


• Cooling-indoor 26.7°CDB/19.4°CWB and Outdoor 35°CDB/23.9°CWB
• Heating-indoor 21.1°CDB/15.6°CWB and Outdoor 8.3°CDB/6.1°CWB
*2 T3 condition
• Cooling-indoor 29DB/19°CWB and Outdoor 46°CDB
*3 Precharge refrigerant in outdoor unit is 4kg. The actual refrigerant amount please refer to
selection software.
*4 These mini VRF models are also available for 220~240-1-50/60HZ Power Supply.

Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

63
YORK® VRF High Ambient System Heat Pump R410A

50/60 HzHigh Efficiency VRF Outdoor Units Quick Selection Guide


REFRIGERANT
COOLING*1 HEATING*1 COMPRESSOR OUTDOOR UNIT
PIPING*3 MAX.
MODEL POWER SUPPLY INDOOR AMBIENT TEMP.
NOMINAL POWER POWER DIMENSION NET/GROSS LIQUID SIDE/
CAPACITY CAPACITY UNITS
CAPACITY INPUT INPUT (W*H*D) WEIGHT GAS SIDE
EER COP TYPE
PIN NUMBER V-PH-HZ KW KW KW KW MM KG MM PIECE °C
Cooling: -5°C - 54°C DB
YV2VYH025KASFDAX 380~400-3-50/60 8 25.42 6.04 4.21 28.08 5.96 4.71 DC INV. SCROLL 1350×720×1690 276/301 Ø12.7/Ø25.4 13 Heating: -23°C - 18°C WB
Cooling: -5°C - 54°C DB
YV2VYH028KASFDAX 380~400-3-50/60 10 29.90 7.35 3.93 33.80 7.36 4.59 DC INV. SCROLL 1350×720×1690 276/301 Ø12.7/Ø25.4 16 Heating: -23°C - 18°C WB
Cooling: -5°C - 54°C DB
YV2VYH033KASFDAX 380~400-3-50/60 12 34.80 8.66 4.02 37.90 8.72 4.35 DC INV. SCROLL 1350×720×1690 279/304 Ø12.7/Ø25.4 20 Heating: -23°C - 18°C WB
Cooling: -5°C - 54°C DB
YV2VYH040KASFDAX 380~400-3-50/60 14 41.50 10.46 3.97 45.80 10.68 4.29 DC INV. SCROLL 1350×720×1690 321/346 Ø12.7/Ø28.58 24 Heating: -23°C - 18°C WB
Cooling: -5°C - 54°C DB
YV2VYH045KASFDAX 380~400-3-50/60 16 46.40 11.78 3.94 51.10 12.16 4.20 DC INV. SCROLL 1350×720×2048 359/384 Ø12.7/Ø28.58 27 Heating: -23°C - 18°C WB
Cooling: -5°C - 54°C DB
YV2VYH050KASFDAX 380~400-3-50/60 18 51.50 13.45 3.83 58.80 14.10 4.17 DC INV. SCROLL 1350×720×2048 359/384 Ø12.7/Ø28.58 30 Heating: -23°C - 18°C WB
Cooling: -5°C - 54°C DB
YV2VYH056KASFDAX 380~400-3-50/60 20 57.80 15.40 3.75 63.70 15.50 4.11 DC INV. SCROLL 1350×720×2048 359/384 Ø12.7/Ø28.58 33 Heating: -23°C - 18°C WB
(DC INV. SCROLL)*2 1350×720×1690 + Cooling: -5°C - 54°C DB
YV2VYH061KASFDAX 380~400-3-50/60 10+12 63.70 16.01 3.98 71.70 16.08 4.46 276/301+279/304 Ø15.88/Ø31.8 36
1350×720×1690 Heating: -23°C - 18°C WB
(DC INV. SCROLL)*2 1350×720×1690 + Cooling: -5°C - 54°C DB
YV2VYH068KASFDAX 380~400-3-50/60 10+14 70.40 17.81 3.95 79.60 18.04 4.41 276/301+321/346 Ø15.88/Ø31.8 40
1350×720×1690 Heating: -23°C - 18°C WB
(DC INV. SCROLL)*2 1350×720×1690 + Cooling: -5°C - 54°C DB
YV2VYH074KASFDAX 380~400-3-50/60 12+14 76.30 19.12 3.99 83.70 19.40 4.31 279/304+321/346 Ø15.88/Ø31.8 43
1350×720×1690 Heating: -23°C - 18°C WB
(DC INV. SCROLL)*2 1350×720×1690 + Cooling: -5°C - 54°C DB
YV2VYH080KASFDAX 380~400-3-50/60 14+14 83.00 20.92 3.97 91.60 21.36 4.29 1350×720×1690 321/346+321/346 Ø15.88/Ø31.8 46 Heating: -23°C - 18°C WB
(DC INV. SCROLL)*2 1350×720×1690 + Cooling: -5°C - 54°C DB
YV2VYH085KASFDAX 380~400-3-50/60 14+16 87.90 22.24 3.95 96.90 22.84 4.24 321/346+359/384 Ø15.88/Ø31.8 50
1350×720×2048 Heating: -23°C - 18°C WB
(DC INV. SCROLL)*2 1350×720×1690 + Cooling: -5°C - 54°C DB
YV2VYH090KASFDAX 380~400-3-50/60 14+18 93.00 23.91 3.89 104.60 24.78 4.22 321/346+359/384 Ø15.88/Ø31.8 53
1350×720×2048 Heating: -23°C - 18°C WB
(DC INV. SCROLL)*2 1350×720×1690 + Cooling: -5°C - 54°C DB
YV2VYH095KASFDAX 380~400-3-50/60 16+18 97.90 25.23 3.88 109.90 26.26 4.19 359/384+359/384 Ø15.88/Ø31.8 57
1350×720×2048 Heating: -23°C - 18°C WB

*1 AHRI1230 Testing condition is: 2- Standard Diff. Indoor/Outdoor Unit: 50 m (Outdoor higher than indoor),
40 m (Indoor higher than outdoor)
• Cooling-indoor 26.7°CDB/19.4°CWB and Outdoor 35°CDB/23.9°CWB Max.Diff. Indoor/Outdoor Unit: 110 m (Outdoor higher than indoor),
• Heating-indoor 21.1°CDB/15.6°CWB and Outdoor 8.3°CDB/6.1°CWB 90 m (Indoor higher than outdoor)

*2 Precharge refrigerant in outdoor unit is 10kg. The actual refrigerant 3- Max/Standard Diff. Indoor/Indoor Unit = 30 m /15 m
amount please refer to selection software.

*3 Piping Limitations: 4 -If the total pipe length is from 500 to 1000m or the height difference
between the outdoor and indoor units is from 50 to 110m or the height
1- Max. Refrigerant Pipe Length = 190 m, Max./Standard Total Pipe difference between the indoor units is from 18 to 30m, you Must contact
Length = 1000 m/ 500 m your local distributor/dealer for individual design and production.


Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

64
YORK® VRF High Ambient System Heat Pump R410A

50/60 Hz High Efficiency VRF Outdoor Units Quick Selection Guide


REFRIGERANT
COOLING*1 HEATING*1 COMPRESSOR OUTDOOR UNIT
PIPING*3 MAX.
MODEL POWER SUPPLY INDOOR AMBIENT TEMP.
NOMINAL POWER POWER LIQUID SIDE/
CAPACITY CAPACITY DIMENSION (W*H*D) NET/GROSS WEIGHT UNITS
CAPACITY INPUT INPUT GAS SIDE
EER COP TYPE
PIN NUMBER V-PH-HZ KW KW KW KW MM KG MM PIECE °C

YV2VYH101KASFDAX 380~400-3-50/60 18+18 102.99 26.90 117.60 28.20


1350×720×2048 + Cooling: -5°C - 54°C DB
3.83 4.17 (DC INV. SCROLL)*2 359/384+359/384 Ø15.88/Ø31.8 60
1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH106KASFDAX 380~400-3-50/60 18+20 109.30 28.85 3.79 122.50 29.60 4.14 (DC INV. SCROLL)*2
1350×720×2048 + Cooling: -5°C - 54°C DB
359/384+359/384 Ø15.88/Ø31.8 64
1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH112KASFDAX 380~400-3-50/60 20+20 115.60 30.80 3.75 127.40 31.00 4.11 (DC INV. SCROLL)*2
1350×720×2048 + Cooling: -5°C - 54°C DB
359/384+359/384 Ø15.88/Ø31.8 64
1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH118KASFDAX 380~400-3-50/60 14+14+14 124.50 31.38 3.97 137.40 32.04 4.29 (DC INV. SCROLL)*3
1350×720×1690+1350×720× Cooling: -5°C - 54°C DB
321/346+321/346+321/346 Ø15.88/Ø31.8 64
1690+1350×720×1690 Heating: -23°C - 18°C WB
YV2VYH124KASFDAX 380~400-3-50/60 14+14+16 129.40 32.70 3.96 142.70 33.52 4.26 (DC INV. SCROLL)*3
1350×720×1690+1350×720× Cooling: -5°C - 54°C DB
321/346+321/346+359/384 Ø15.88/Ø31.8 64
1690+1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH130KASFDAX 380~400-3-50/60 14+14+18 134.50 34.37 3.91 150.40 35.46 4.24 (DC INV. SCROLL)*3
1350×720×1690+1350×720× Cooling: -5°C - 54°C DB
321/346+321/346+359/384 Ø15.88/Ø31.8 64
1690+1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH136KASFDAX 380~400-3-50/60 14+16+18 139.40 35.69 3.91 155.70 36.94 4.21 (DC INV. SCROLL)*3
1350×720×1690+1350×720× Cooling: -5°C - 54°C DB
321/346+359/384+359/384 Ø15.88/Ø31.8 64
2048+1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH141KASFDAX 380~400-3-50/60 14+18+18 144.49 37.36 3.87 163.40 38.88 4.20 (DC INV. SCROLL)*3
1350×720×1690+1350×720× Cooling: -5°C - 54°C DB
321/346+359/384+359/384 Ø15.88/Ø31.8 64
2048+1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH146KASFDAX 380~400-3-50/60 16+18+18 149.39 38.68 3.86 168.70 40.36 4.18 (DC INV. SCROLL)*3
1350×720×2048+1350×720× Cooling: -5°C - 54°C DB
359/384+359/384+359/384 Ø15.88/Ø31.8 64
2048+1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH151KASFDAX 380~400-3-50/60 18+18+18 154.49 40.35 3.83 176.40 42.30 4.17 (DC INV. SCROLL)*3
1350×720×2048+1350×720× Cooling: -5°C - 54°C DB
359/384+359/384+359/384 Ø15.88/Ø31.8 64
2048+1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH157KASFDAX 380~400-3-50/60 16+20+20 162.00 42.58 3.80 178.50 43.16 4.14 (DC INV. SCROLL)*3
1350×720×2048+1350×720× Cooling: -5°C - 54°C DB
359/384+359/384+359/384 Ø15.88/Ø31.8 64
2048+1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH162KASFDAX 380~400-3-50/60 18+20+20 167.10 44.25 3.78 186.20 45.10 4.13 (DC INV. SCROLL)*3
1350×720×2048+1350×720× Cooling: -5°C - 54°C DB
359/384+359/384+359/384 Ø15.88/Ø31.8 64
2048+1350×720×2048 Heating: -23°C - 18°C WB
YV2VYH168KASFDAX 380~400-3-50/60 20+20+20 173.40 46.20 3.75 191.10 46.50 4.11 (DC INV. SCROLL)*3
1350×720×2048+1350×720× Cooling: -5°C - 54°C DB
359/384+359/384+359/384 Ø15.88/Ø31.8 64
2048+1350×720×2048 Heating: -23°C - 18°C WB

*1 AHRI1230 Testing condition is: 2- Standard Diff. Indoor/Outdoor Unit: 50 m (Outdoor higher than indoor),
40 m (Indoor higher than outdoor)
• Cooling-indoor 26.7°CDB/19.4°CWB and Outdoor 35°CDB/23.9°CWB Max.Diff. Indoor/Outdoor Unit: 110 m (Outdoor higher than indoor),
• Heating-indoor 21.1°CDB/15.6°CWB and Outdoor 8.3°CDB/6.1°CWB 90 m (Indoor higher than outdoor)

*2 Precharge refrigerant in outdoor unit is 10kg. The actual refrigerant 3- Max/Standard Diff. Indoor/Indoor Unit = 30 m /15 m
amount please refer to selection software.

*3 Piping Limitations: 4 -If the total pipe length is from 500 to 1000m or the height difference
between the outdoor and indoor units is from 50 to 110m or the height
1- Max. Refrigerant Pipe Length = 190 m, Max./Standard Total Pipe difference between the indoor units is from 18 to 30m, you Must contact
Length = 1000 m/ 500 m your local distributor/dealer for individual design and production.


Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

65
YORK® VRF High Ambient System Heat Pump R410A

50/60 Hz VRF Indoor Units Quick Selection Guide


CAPACITY KBTU/H 7.5 9.5 12.3 15.3 19.1 24.2 27.3 30.7 38.2 47.7 77.1 95.5 CAPACITY KBTU/H 7.5 9.5 12.3 15.3 19.1 24.2 27.3 30.7 38.2 47.7 77.1 95.5
PRODUCT FAMILY PRODUCT FAMILY
CAPACITY KW 2.2 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14 22.6 28 CAPACITY KW 2.2 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14 22.6 28

DUCTLESS INDOOR UNITS DUCTED INDOOR UNITS

SLIM LOW STATIC


TWO WAY
CASSETTE • • • • PRESSURE DUCT
(0/20PA) • • • • •
LOW STATIC
• • • • • •
FOUR WAY
COMPACT
CASSETTE (700X700) • • • PRESSURE DUCT
(0/20PA)

MEDIUM STATIC
FOUR WAY
CASSETTE (950X950) • • • • • • PRESSURE DUCT
(50/96PA) • • •
MEDIUM STATIC
HIGH WALL
• • • • • • PRESSURE DUCT
(80/120PA) • • •
CONSOLE
• • • • HIGH STATIC
PRESSURE DUCT
• • • • • •
(100/196PA)
FLOOR CEILING
• • • • • • • • • • •
• Built in High Head drain Pump (2-Way Cassette & 4-Way Cassette) •
FRESH AIR UNIT
• Wide Range Angle Air Flow (Floor Ceiling)
• Stylish Design and LED (High Wall) • •
• Top and Bottom Supply Air (Console) HEAT RECOVERY
VENTILATOR (CMH/ 150/88 260/153 800/471 1000/588
• Built in EEV CFM)

• 185mm Height Ultra Thin Design (Slim Ducted) • Build in Drain Pump (Ducted &Fresh Air Unit)
• 220mm Height Ultra Thin Design (Low Static Ducted) • Built in EEV
Note: Following continuous improvement, data is subjected to change without prior notice please contact Al Salem Johnson Controls, Saudi: 920003588

66
ALLIED
PRODUCTS
YORK® Commercial and Industrial Supply and Exhaust Fans

Downblast | EVD Make-Up Air, Filtered Supply | MAF, MAS


• Roof-mount, spun aluminum downblast. • Roof-mount filtered supply.
• Direct or belt drive, EC motor option. • Direct or belt drive.
• Application: General exhaust for schools, churches, and office buildings. • Side Intake (MAS Model)
• Capacity: Up to 39,100 cfm; 0 - 1.5” w.g. • Application: Supply fresh air to buildings or systems by replacing
the exhaust of contaminated air (e.g., Commercial kitchens).
• Miami-Dade Approved for High Velocity Hurricane Zones (NOA# 10-0615.09).
• Capacity: Up to 14,400 cfm; 0 - 1.0” w.g.

Upblast | EVU
Ceiling Inline | CI
• Roof-mount, spun aluminum upblast; direct or belt drive; EC motor option.
• Ceiling or inline mount.
• Application: Fumes, commercial kitchens, and exhaust of other
contaminants. • Low sound levels.

• U.L. Listed for Smoke Control Systems (500°F / 4-Hours; 1000°F / 1-Hour). • Direct drive.

• U.L. 762 Listed for Grease Laden Air Exhaust (400°F). • Application: General exhaust for lavatories, conference rooms, and institutions.

• Capacity: Up to 22,900 cfm; 0 - 4.3” w.g. • Capacity: From 32 - 3,290 cfm; 0 - 1.5” w.g.

• Miami-Dade Approved for High Velocity Hurricane Zones (NOA# 10-0615.09). • U.L. Listed for use over bathtubs and showers when connected to a GFCI
protected branch circuit.

Utility Set | US
Axial Prop | PAFP, PAFX, PAFC, PAFL, PAFM, PAFH, PAFB
• Class I heavy-gauge galvanized steel, roof/floor/inline mount utility blower.
• Wall-mount propeller fans.
• Belt drive; backward inclined wheel.
• Direct or belt drive.
• Application: Commercial kitchen and fume exhaust, building pressurization,
and fresh air supply. • Application: General supply and exhaust for warehouses, factories, and
mechanical rooms.
• U.L. 762 Listed for Grease Laden Air Exhaust (500°F).
• Capacity: Up to 68,100 cfm; 0 - 1.5” w.g.
• U.L. Listed for Smoke Control Systems (500°F / 4-hours; 1000°F / 41-minutes).
• Capacity: Up to 36,000 cfm; 0 - 5.0” w.g. Centrifugal Inline | CIX
• Ceiling or inline mount.
Centrifugal Inline Square | CIS
• Low sound levels; EC motor.
• Square inline duct-mount.
• Application: General exhaust for lavatories, conference rooms, and
• Direct or belt drive; EC motor option. institutions.

• Application: Supply, return, or exhaust air for general HVAC systems. • Capacity: From 100-500 cfm; 0-1.0” w.g.

• Capacity: From 103 - 27,500 cfm; 0 - 3.5” w.g. • Selection of grille designs including Energy Star lighted grilles.

• Inlet filter box with 1” or 2” filters. • UL 705 and UL 507 listed for use over bathtubs and showers when connected
to a GFCI protected branch circuit.

68
YORK® Commercial and Industrial Supply and Exhaust Fans

Low Contour Downblast | CLD Centrifugal Inline Round | CIR


• Roof-mount, low contour downblast. • Tubular inline duct-mount.
• Direct or belt drive. • Aluminum construction.
• Application: General exhaust for schools, churches, and office buildings. • Direct or belt drive.
• Capacity: Up to 20,000 cfm; 0 - 1.5” w.g. • Application: Supply or return air; exhaust fumes or humid air.
• Capacity: Up to 22,000 cfm; 0 - 3.0” w.g.

Centrifugal Downblast Roof Exhauster | CRDE


Mixed Flow Inline | MFSI
• Roof-mount, low contour downblast.
• Class I, II heavy-gauge steel, mixed flow inline fan.
• Architectural, tiered hood design.
• Belt drive; patented wheel design.
• Direct or belt drive.
• Application: Exhaust, supply, or return air in ducted (medium to high) pressure
• Application: General exhaust for schools, churches, and office buildings. systems requiring lower sound levels.
• Capacity: Up to 19,400 cfm; 0 - 1.5” w.g. • Capacity: Up to 155,000 cfm; 0 - 7.0” w.g.
• U.L. 762 Listed for Grease Laden Air (300°F & 500°F).
• U.L. Listed for Smoke Control Systems (500°F / 4-hours; 1000°F / 1-hour).
Ceiling Cabinet | CC, CCB
• Inline duct-mount.
Stack Fan | YSF
• Belt drive.
• Modular, scalable, and stackable design capable of standalone applications.
• Application: General purpose duct blower for heating/cooling systems.
• Cooling Coil Fan Array
• CC (Single) Capacity: From 750 - 6,350 cfm; 0 - 1.5” w.g.
• Application: Air handlers, rooftop units, and retrofit applications for
• CCB (Twin) Capacity: From 1,500 - 12,700 cfm; 0 - 1.5” w.g. commercial facilities such as, telecom data centers, commercial facilities,
healthcare facilities, and schools.

Vertical Discharge Exhauster | VUC, VUX, VUF, VUZ, VUS • Capacity: Up to 200,000 cfm; 0 - 10.0” w.g.

• Roof-mount propeller upblast.


• Direct or belt drive.
Roof Turbine | GTRT, GTRH, GTRA
• Standard height or low profile.
• Turbines: General ventilation of factories, farm/agricultural buildings,
• Application: Rapid air removal or general ventilation exhaust. commercial/public structures, and homes.

• U.L. Listed for Smoke Control Systems (500°F / 4-hours; 1000°F / 15-minutes). • Pul-Air for air exhaust with no moving parts.

• Capacity: Up to 82,400 cfm; 0 - 1.0” w.g. • Insul-Air for extended airshaft to clear roof peaks, etc.

69
Non-YORK® Allied Products

Sound Attenuators, Fire and Air Terminals (VAV & Over 85 Years of Innovation Since Cvsair was
Smoke Dampers CAV) established in Turkey
Save time and increase in 2008, it has been
Ruskin is owned by Al Salem Another brand owned by profits by using Victaulic. working in harmony
Johnson Controls. And since Al Salem Johnson Controls. Grooved End Pipe Joining, or with the companies that
1958, it has been the name As has been our legacy, we the “grooved” concept, as it have cooperation as a
in air management solutions continue to advance every is known today, was born in manufacturer in ventilation
that engineers, architects and aspect of our business to 1925 when Victaulic introduced systems and energy
contractors rely on to make meet the changing needs the first mechanical pipe efficiency, as well as being
buildings safer, more energy of our customers and HVAC joint to successfully use a one of the most reputable
efficient and comfortable. Our professional’s worldwide. mechanical coupling combined companies in Turkey with
mission is to make everyone At Titus our goal is very with grooved pipe ends to join our professional team.
comfortable. From the owners, clear: to help the people piping systems.They called this
to the designers, to the installers, who depend upon us by invention, the Victory Joint. In terms of ventilation and
to the occupants, Ruskin and our continuing to innovate energy efficiency, Cvsair
industry partners strive to make and advance the science Victory + hydraulic = Victaulic are a reliable manufacturer.
your well-being our top priority. of air distribution. We are They are working with
Today you will find Victaulic
We offer the most complete line committed to building the philosophy of open
grooved mechanical systems
of air control and architectural on opportunities that communication and
used in endless number
products and support them with significantly improve the of piping applications all customer satisfaction by
our reputation for quality design health, efficiency, comfort over the world. While the a high quality products at
and precision manufacturing, and aesthetics of the grooved concept has become the right prices, and short
backed by cutting-edge environments in which our term delivery. Cvsair is also
synonymous with faster and
technology, rigorous testing, products are used. the first member of Amca
easier installations, not all
on-time delivery and technical manufacturers of grooved in Turkey and producing all
support. The manufacturing facility
products are the same. its products according to
in UAE has exceeded Amca standards.
The manufacturing facility in international quality
Victaulic Grooved Systems
UAE has exceeded international standards as exemplified by Cvsair are experiencing
provides your system with the
quality standards as exemplified achieving ISO 9001:2008 the pride of their attempts
benefits:
by achieving ISO 9001:2008 certification and products to be ranked among the
certification and products that that are approved by AHRI. • require 45 percent less global market with the
are approved by UL, AHRI and All Titus Terminal Units man-hours on average over number of countries they
AMCA. All Ruskin’s designs of (VAV units) and Air Outlets welding export reaching up to 16,
Fire, Smoke and Combination Fire manufactured at Umm Al being an engineering and
& Smoke Dampers manufactured Quwain factory deliver • Eliminate costly fire watch and manufacturing company
by RTG, bear the UL label. These identical performance that hazardous fumes and flames conveying goods to
facilities have the state-of-the- meet the stringent quality countries located on 3
• Reduce material handling by
art machinery and tooling to standards as required at different continents and
30 – 70 percent
meet the design specifications of our manufacturing facilities the quality and reliability of
Ruskin engineering standards. in the USA. • Reduce energy consumption Turkish products.

Note: For more information, please contact Al Salem Johnson Controls, Saudi: 920003588

70
DISCOVER COMPLETE, CONNECTED SOLUTIONS TO HELP YOU INCREASE COMFORT, SECURITY AND EFFICIENCY
WATER-COOLED CHILLERS ABSORPTION CHILLERS & HEAT PUMP
ELECTRIC
HOT WATER
SINGLE EFFECT HOT WATER
• YHAU-CL/CH
YORK® YMC2 • 105 - 6,153 kW / 30 - 1,750 TR
• 165 – 1000 tons
• Magnetic bearing centrifugal chiller, oil free, very quiet

LOW PRESSURE STEAM


SINGLE EFFECT STEAM FIRED
• YHAU-C
• 422 - 5,275 kW / 120 - 1,500 TR
YORK® YCWL
• 50 – 200 tons
• Scroll compressor MEDIUM PRESSURE STEAM
DOUBLE EFFECT STEAM FIRED
• YHAU-CW
• 422 - 14,067 kW / 120 - 4,000 TR

YORK® YK
• 250 – 3,000 tons DIRECT FIRED
• Variable speed centrifugal compressor, OptiView™ control SMALL DOUBLE EFFECT NATURAL GAS OR LIGHT
panel OIL*
• YHAU-F
• 105 - 352 kW / 30 - 100 TR

YORK® YK-EP DIRECT FIRED


• 2,500 – 3,500 tons LARGE DOUBLE EFFECT NATURAL GAS OR LIGHT OIL
• Centrifugal compressors with economizer, VSD, OptiView™ • YHAU-CG
control panel • 422 - 4,395 kW / 120 - 1,250 TR

EXHAUST GAS
DOUBLE EFFECT DIRECT EXHAUST GAS
YORK YD®
• YHAU-CE
• 1,500 – 6,000 tons • 527 - 3,516 kW /150 - 1,000 TR
• Dual centrifugal compressors, smallest footprint per cooling
ton, OptiView™ control panel
EXHAUST GAS AND LOW
TEMPERATURE HOT WATER
MULTI ENERGY
• YHAU-CE -J
YORK® CYK • 527 - 3,516 kW /150 - 1,000 TR
• 300 – 2,500 tons
• High-head capability, compound centrifugal compressors
with economizer, open drive EXHAUST GAS AND LOW TEMPERATURE HOT
WATER AND DIRECT FIRED
MULTI ENERGY
• YHAU-CGE-J
• Custom capacity

YORK® OM
• 3,000 – 5,500 tons NATURAL GAS AND LOW TEMPERATURE HOT
• Custom-designed, centrifugal compressor WATER
GAS GENE-LINK
• YHAU-CG-J
• 422 - 4,395 kW / 120 - 1,250 TR
THERMALLY DRIVEN
MEDIUM PRESSURE STEAM
AND LOW TEMPERATURE HOT WATER
STEAM GENE-LINK
YORK® YST • YHAU-CW-J
• 700 – 2,800 tons • 422 - 14,065 kW / 120 - 4,000 TR
• Centrifugal compressor, steam-turbine driven

MEDIUM PRESSURE STEAM, DIRECT FIRED, HIGH


TEMPERATURE HOT WATER
DOUBLE EFFECT LOW TEMPERATURE (-5°C)
• YHAU-C-L
CENTRAL PLANT OPTIMIZATION™ (10) • 176 - 1,758 kW / 50 - 500 TR

LOW PRESSURE STEAM, MEDIUM PRESSURE


STEAM, DIRECT FIRED
CPO 10 SINGLE EFFECT ABSORPTION HEAT PUMP (UP TO
Intelligent algorithms inherent in METASYS® leverage
95°C)
proven best practices and specifi c equipment effi ciency
• YHAP-C
characteristics to serve up to 15% energy versus standard
• 900 - 40,000 kW
automation

71
AIR-COOLED CHILLERS AIR HANDLING UNITS RESIDENTIAL & LIGHT COMMERCIAL UNITS VERASYS™ SMART CONTROL SYSTEM
YSM MODULAR AIR HANDLING UNIT
YORK® YCAL • 1,200 to 99,180 m3/hr
• 15 – 28 tons • AHRI Certified | Thermal Break Profile
• Scroll compressor SMART BUILDING HUB
Web based control system that provides a mobile user
YMA CUSTOM MADE AIR HANDLING UNITS
interface to smart equipment branded controllers and
• 900-180,000 m3/hr
thermostats
YORK® YLAA • Flexible construction, premium product
• 40 - 230 tons • AHRI and Eurovent Certified | Thermal Break Profile
• Scroll compressor, micro channel coils Ducted Split Units 18 - 300 MBH
YMA-H HYGENIC AIR HANDLING UNITS
• Hygienic structure, casing, and components Ductless Split Units
YORK® YVAA • Comply with hygiene requirements DIN 1946 and VDI Hi-Wall 12 - 32 MBH
• 150 - 500 Tons 6022 | High efficient filteration
• Variable speed screw compressor, Hybrid falling film Cassette 18 - 32 MBH SMART EQUIPMENT CONTROLLERS
evaporator YMA-M MULTI-FAN AIR HANDLING UNITS Family of controllers and accessories specifically designed for
Ceiling Floor 18 - 32 MBH
• Provide more redundancy, reliability, and HVAC/R equipment optimization
serviceability to the system Free Standing 55 MBH
• Plug fans with VFD/EC Motor options
Window Room AC Units 18 - 24 MBH
PACKAGED (ROOF TOP) UNITS • Variance no. of fans to meet airflow requirements

RESIDENTIAL RTU YMS MODULAR AIR HANDLING UNITS

STELLAR DEH - MICRO


• 1000-37,440 m3/hr
• Standard product | AHRI certified VRF PRODUCTS
TERMINAL UNIT CONTROLLER PLUS
• 3 - 6 Tons
Designed for local complete control of unitary equipment with
• Cool only, R410A SOLUTION AIR HANDLING UNITS
AMAZON VRF BACnet supervisory communication
• Air handling units with high-performance,
Modular construction • Wide capacity range of the Outdoor unit ( 8 HP to
COMMERCIAL RTU • Manufactured in USA 60 HP )

PREDATOR ZH
• 6.5 - 10 Tons
• Cool only, R410A INDUSTRIAL REFRIGERATION YORK® VRF (JCH)
• New energy saving technology
RECIPROCATING COMPRESSOR UNIT • Flexible construction, premium product
STELLAR DEH - MEDIUM SMART THERMOSTAT
• Cooling Capacity Range - 50-1400 kW
• 12.5 - 30 Tons Family offers Proportional, ON/OFF, Multistage, autoadaptative
• Low power consumption during part load
• Cool only, R410A controls through thermostats

SCREW COMPRESSOR UVNIT


STELLAR DEH - MAJOR • Cooling Capacity Range - 121-5700 kW FAN COIL UNITS
• 35 - 50 Tons • Highest COP value
• Cool only, R410A
YGFC / YDFC / YAH
CHILLERS - PISTON COMPRESSOR - PAC • 150 - 8300 CFM
STELLAR DEH - MEGA • Cooling Capacity Range - 50 - 1400 kW • Max 500 ESP, Eurovent Certified
• 65 - 100 Tons • Skid-mounted COMPUTER ROOM AIR CONDITIONING
• Cool only, R410A • Factory-tested
JTHD
• 300 - 1200
UNITS - CRAC
STELLAR DEH - TOTAL FRESH AIR CHILLERS - SCREW COMPRESSOR - PAC • Exposed, CE Certified
• 12.5 - 15.8 Tons • Cooling Capacity Range – 120 - 8000 kW P-SERIES
• Cool only, R410A • Skid-mounted DIRECT EXPANSION
• Factory-tested YLH/ YLIH/ YKEY/ YEFB
• 6 - 100 KW
• 100 - 1800 CFM
DEM - MEDIUM • 12,500 CFM
• Max 500 ESP, Eurovent Certified
• 23 - 41 Tons COMPACT CHILLER - CHILLPAC CHILLED WATER
• Cool only, R410A • (Piston compressors) - comPACt (screw compressors) • 6 - 200 KW
• Capacity Range 100-2000 kW - Very Compact FH/ FN/ AHI/ AVI • 20,000 CFM
• 250 - 4000 CFM Suitable for environments where thermal loads of a
STANDARD HEATPUMP PACKAGE - HEATPAC • Max 280 ESP, ARI 440 Certified sensitive nature prevail.
• Heating Capacity Range – 240 - 1150 kW,
CONDENSING UNITS • Outgoing Temperature – up to 70°C
G-SERIES
TAURUS YE7
• 6 - 25 Tons
HIGH TEMPERATURE HEATPUMP PACKAGE
• Heating Capacity Range – up to 1600 kW
ALLIED PRODUCTS CHILLED WATER
• 60 - 300 KW
• Cool only, R410A • Outgoing Temperature – up to 90°C • 23,000 CFM
YORK VENTILATION FANS BY Suitable for meeting the design criteria of the latest
CASCADE REFRIGERATION PACKAGE - CAFP AL SALEM JOHNSON CONTROLS generation data centers.
STELLAR DCH - MINI • Cooling Capacity Range – 80-800 kW
• 7 - 15 TONS
• Low Operating Cost and Compact Design
• Cool only, R410A RTG RUSKIN TITUS GULF PRODUCTS
AIR COOLED CHILLER - SABLIGHT BY AL SALEM JOHNSON CONTROLS
R-SERIES
STELLAR DCH - MEDIUM • Cooling Capacity Range – 120 - 338 kW CHILLED WATER
• 16 - 30 TONS • Green” Refrigerant – R290 • 10 - 40 KW
• Cool only, R410A GROOVED COUPLING BY VICTAULIC
• 5,500 CFM
MULTISTAGE CENTRIFUGAL COMPRESSOR UNIT Built and sized in such a way that they can be installed
STELLAR DCH - MAJOR • Cooling Capacity – up to 11 500 kW alongside data center racks with special discharge
ELECTRICAL WATER HEATERS BY
• 35 - 50 Tons • Designed for heavy industrial use directions.
BRADFORD WHITE
• Cool only, R410A
* Actual Performance of the Close Control Units could
OTHER REFRIGERATION PRODUCTS
STELLAR DCH - MEGA be affected based on design criteria of the specific
• AcuAir Hygienic Air Handler
• 65 - 100 Tons project.
• Plate and Frame Heat Exchangers VENTILATION FANS BY CVSAIR
• Cool only, R410A • Refrigerants Vessels

72
BUILDING MANAGEMENT SYSTEMS PENN® REFRIGERATION PRODUCTS INTEGRATED FIRE & SECURITY, LIFE-SAFETY PROTECTION

METASYS® SERVER PRESSURE SWITCHES & THERMOSTATS FIRE HAZARD PROTECTION INTEGRATED SECURITY
Support of IT standards and technologies, Multi-platform The pressure switches, thermostats and humidistats are
web-based user interface, long-term storage designed for refrigeration, cooling, heating, ventilation and SECURITY, FIRE & LIFE-SAFETY INTEGRATION
airconditioning applications FIRE DETECTION & ALARM We are a security integrator with a vast product ecosystem specializing
Flexible, reliable, cost-effective and highly scalable systems that can in the design, installation and service of security and life-safety
grow and expand as buildings change. solutions for the most complex, mission critical environments.

NETWORK AUTOMATION ENGINE ELECTRONIC CONTROLS & TRANSDUCERS


The controllers, are designed and provide a high quality long WATER FIRE SUPPRESSION
Family of IP connected network supervisory controllers for SECURITY MANAGEMENT SYSTEM (P2000)
all sizes of building management systems lasting solution for control of any commercial refrigeration unit High-performance sprinkler, deluge & water mist systems. Open security management platform with integrated access
(cold rooms, display cases, compressor rack,...)
control, embedded video management and industry-wide
For use in a variety of applications (pressure, fan speed,
third-party integrations.
temperature, humidity....)
SPECIAL HAZARD FIRE SUPPRESSION
Foam, clean agent and inert gas systems provide unique answers to
NETWORK CONTROL ENGINE WATER VALVES & FLOW CONTROLS unique challenges. ACCESS CONTROL / BIOMETRICS
Family of IP connected supervisory controllers with onboard These pressure actuated modulating valves control the quantity Access control readers, doors, gates and devices help control,
Input/Output (IO) points of water to a condenser by directly sensing pressure changes track and manage access to any facility.
in a refrigerant circuit. The mechanical liquid flow switches can MASS NOTIFICATION SYSTEMS
be used in liquid lines carrying water, sea water, swimming pool Customizable, multi-tiered technology helps improve situational
water, ethylene glycol or other liquids awareness and response time.
INTRUSION DETECTION
Solutions customized for each customer leveraging contact
devices, motion and glass break detection, panic buttons, photo
FIELD EQUIPMENT CONTROLLER beam and much more.
ELECTRONIC EXPANSION VALVES MECHANICAL PRODUCTS
Complete family of BACnet IP and MS/TP fi eld controllers
The combination of Quick Response Expansion Valves (QREV) Cost-effective grooved piping solutions for a full range of fire,
and Precision SuperHeat Controller (PSHC) forms an mechanical, HVAC and industrial applications.
electronically controlled expansion valve that will maximize PERIMETER PROTECTION
evaporator efficiency Help achieve a more secure perimeter with ground based radar
systems, video surveillance and monitored alarm systems.
GAS AND FLAME DETECTION
INPUT/OUTPUT MODULES Advanced sensor technology for multiple flame and toxic gas detection. VIDEO SURVEILLANCE, VIDEO MANAGEMENT & STORAGE
Scalable family of configurable Input/Output (IO) modules Robust surveillance systems with video cameras, monitors, CCTV and
remote management tools. Scalable, integrated solutions and advanced
HVAC SYSTEM CONTROL PRODUCTS video analytics.

LIFE-SAFETY AND PERSONAL PROTECTION SECURITY MONITORING


Fully redundant, UL®-listed Customer Care Centers provide 24/7/365
VAV CONTROLLERS PEAK CONTROLLERS
Family of controllers and accessories specifically designed
RESPIRATORY PROTECTION SYSTEMS security monitoring.
Complete family of programmable controllers suitable for all Supplied air respirators, cylinders, air purifying respirators (APR),
VAV applications for Original Equipment Manufacturers (OEMs)
and many more solutions that address broad hazardous and COMMAND & CONTROL
industrial applications. Physical security information management (PSIM) helps manage all
TERMINAL UNIT VALVES AND ACTUATORS integrated physical security from one streamlined interface.
Complete offering of valves and actuators for terminal unit THERMAL IMAGING PRODUCTS
applications NFPA-compliant technology offers comprehensive capabilities to
TERMINAL UNIT CONTROLLER VEHICLE & GATE MANAGEMENT
maximize situational awareness. K-rated fences and gates, pop-up vehicle barriers, traffic barricades and
Complete local control of unitary equipment, plus
supervisory communication CONTROL VALVES AND ACTUATORS more to help protect against unauthorized people, vehicles, explosives
Ball, globe and butterfl y valves with pneumatic and electric and other threats.
PERSONAL PROTECTIVE EQUIPMENT
actuators Innovative, industry specific equipment for first responders, firefighters,
law enforcement, military and industrial personnel. DURESS & NOTIFICATION SYSTEMS
Broadcast critical messages quickly, all from a simplified
DAMPER ACTUATORS web-based interface.
INTEGRATED ROOM CONTROLLER Spring and non-spring return rotary actuators for air, fire
Complete family of controllers and sensors for HVAC, light and smoke dampers COMPRESSORS
and sunblind Vertical and horizontal units are designed as free-standing modules.
MANAGED SERVICES
Managed video, access control, mobile management, video guard and
PLANT SENSORS COMMUNICATION SYSTEMS cloud-based video connected across a variety of platforms to help
Plant Temperature, Humidity, CO2, Dew point, Delta pressure Robust person-to-person communications, advanced audio and maintain secured environments in real-time.
wireless technologies, and two-way radio interoperability.
FIELD USER INTERFACES
Self configuring local touch screen display or web server ROOM SENSORS
user interface options allowing simplified access to OPERATIONAL INTELLIGENCE &
equipment or controls
Room Temperature, Humidity, CO2, Passive, Analog and
Network models
RETAIL SOLUTIONS
ASSET PROTECTION
LOSS PREVENTION
Integrated solutions to help reduce theft and fraud. Key components VIDEO-BASED ANALYTICS
ALL IN ONE ROOM MODULE include store front detection systems (EAS, RFID), tags and labels Video analytics software, web-based video analytics, servers,
Temperature, Humidity and CO2 for products, and camera systems. Software and analytic solutions video audits and more help to analyze the data that matters across
WIRELESS COMPONENTS help efficiency and provide insight. many industries.
Wireless field buses and room temperature sensing systems
designed with the latest wireless technology INVENTORY INTELLIGENCE
THERMOSTATS TrueVue leverages item-level RFID-enabled technology enabling
Line powered Fan Coils thermostats stand alone, Modbus
REAL-TIME LOCATION SYSTEMS (RTLS)
real-time item-level inventory visibility through the supply chain and Help keep staff and equipment safe with an RTLS that monitors
and BACnet communicating
into stores. equipment, medications, temperature sensitive products and staff
TRAFFIC INSIGHTS
INTEGRATION SOLUTIONS ShopperTrak provides insights into more than 40B shopper visits per
SMART THERMOSTAT INFORMATION MANAGEMENT SOLUTIONS
Adapts legacy systems, proprietary systems and systems year, including store perimeter traffic counts, interior shopper analytics,
TEC family offers Proportional, ON/OFF, Multi-stage, Integrate multiple systems from multiple vendors across multiple
with standard protocols to the current METASYS open labor analytics and market intelligence dashboards to help retailers
autoadaptative controls through thermostats locations to more effectively manage overall security.
system architecture increase traffic, conversion rates and transaction size.

73
Minimum Efficiencies for Saudi Arabia
REFERENCE STANDARD PRODUCT CATEGORY AIR CONDITIONER APPLIANCE TYPE CAPACITY RANGE (BTU/HR) MIN EER @ T1 MIN EER @ T3 G-MARK

Window CC ≤ 24,000 9.80 7.00


SASO 2663 Home appliances Window 24,000 < CC ≤ 65,000 9.00 6.20 Mandatory
Split CC ≤ 65,000 11.80 8.30
CC ≤ 65,000 11.20
65,000 < CC ≤ 135,000 11.20
Unitary Air Conditioning Equipment Air conditioners air cooled 135,000 < CC ≤ 240,000 11.00
240,000 < CC ≤ 760,000 10.00
760,000 < CC 9.70
CC < 65,000 11.20
65,000 ≤ CC ≤ 135,000 11.20
VRF - air cooled
135,000 < CC ≤ 240,000 11.00
240,000 < CC 10.00
VRF
CC ≤ 65,000 11.20
65,000 < CC ≤ 135,000 11.00
VRF - heat pumps
135,000 < CC ≤ 240,000 10.60
240,000 < CC 9.50
CC ≤ 135,000 11.00
Condensing unit Condensing units, air cooled
CC > 135000 10.50
SASO 2874
CC ≤ 1,800,000 9.70
Air Cooled Chillers
CC > 1,800,000 9.70
CC ≤ 900,000 15.40
900,000 < CC ≤ 1,800,000 16.00
Water-Cooled electrically operated, positive
1,800,000 < CC ≤ 3,600,000 17.70
displacement
Chillers 3,600,000 < CC ≤ 7,200,000 19.20
7,200,000 < CC 19.20
CC ≤ 3,600,000 17.30

Water-Cooled electrically operated, 3,600,000 < CC ≤ 7,200,000 20.50


centrifugal 7,200,000 < CC ≤ 14,400,000 20.50
14,400,000 < CC 20.50
water Cooled absorption, single effect 2.40
Air Cooled absorption, double effect, indirect
Absorption Chillers all capacities 3.40
fired
Air Cooled absorption, double effect, direct
3.40
fired

74
Minimum Efficiencies for Saudi Arabia
Reference Standard product category Air Conditioner Appliance Type Capacity Range (Btu/hr) COP

Down-Flow unit CC < 65,000 2.30

Up-flow unit - Ducted CC < 65,000 2.10

Up flow unit - Non-Ducted CC < 65,000 2.09

Horizontal-Flow Unit CC < 65,000 2.45

Down-Flow unit 65,000 ≤ CC < 240,000 2.20

Up-flow unit - Ducted 65,000 ≤ CC < 240,000 2.05


Computer and Data Processing
Room Air Conditioners - Air Cooled
Up flow unit - Non-Ducted 65,000 ≤ CC < 240,000 1.99

Horizontal-Flow Unit 65,000 ≤ CC < 240,000 2.35

Down-Flow unit 240,000 ≤ CC 2.00

Up-flow unit - Ducted 240,000 ≤ CC 1.85

Up flow unit - Non-Ducted 240,000 ≤ CC 1.79

Horizontal-Flow Unit 240,000 ≤ CC 2.15


SASO 2874
Down-Flow unit CC < 65,000 2.50

Up-flow unit - Ducted CC < 65,000 2.30

Up flow unit - Non-Ducted CC < 65,000 2.25

Horizontal-Flow Unit CC < 65,000 2.70

Down-Flow unit 65,000 ≤ CC < 240,000 2.40

Computer and Data Processing Up-flow unit - Ducted 65,000 ≤ CC < 240,000 2.20
Room Air Conditioners - Water
Cooled Up flow unit - Non-Ducted 65,000 ≤ CC < 240,000 2.15

Horizontal-Flow Unit 65,000 ≤ CC < 240,000 2.60

Down-Flow unit 240,000 ≤ CC 2.25

Up-flow unit - Ducted 240,000 ≤ CC 2.10

Up flow unit - Non-Ducted 240,000 ≤ CC 2.05

Horizontal-Flow Unit 240,000 ≤ CC 2.45

75
Psychrometric Chart Normal Temperature - SI Units - Barometric Pressure: 101.325 kPa

Useful Unit Conversion Factors


0.20 0.25 0.30 0.35 0.40
Area SENSIBLE HEAT RATIO = Qs / Qt
1 m2 = 1550 in2 = 10.764 ft 2
Fan Law Pump Power
If the wheel diameter is constant flow (l ⁄s) X Head (m) X Specific Gravity
Pump kw =
Volume 103.2 X Percent of Pump efficiency 34.0
Heat Flow (Power) 10
0
Volume1 / Volume2 = (Speed1 / Speed2) 33.0
1 kW (kJ/s) = 859.9 kcal/h = 3,413 Btu/h Altitude Air Density Ratio at 21 oC 28 0.45
Head or Pressure 30 32.0
1 hp = 0.74570 kW 600 m 0.930
30
SP1 / SP2 = (Speed1 / Speed2)2
1 ton of refrigeration = 12,000 Btu/hr = 3.51 kw 1200 m 0.864
31.0
Power 90 26
30.0
1800 m 0.801
P1 / P2 = (Speed 1 / Speed 2)3
Heat Transfer coefficient 2400 m 0.743 0.50 29.0
1 Btu/ft h F = 5.678 W/m K = 4.882 kcal/h m C
2 o 2 2 o
PSYCHROMETRIC 30
W
ET
24 28.0
13
0

CHART
80
Cooling / heating capacity BU
LB 27.0
Length TE
Sensible Heat kW = 1.23 x m3/s x Δt (0C)
Normal Temperature M
PE 22
0.55 26.0

0.92
1 m (meter) = 3.2808 ft = 39.37 in Latent Heat kW = 3010 x m /s x Δw (kg water/kg dry air) 3 RA
TU
1 in (inch) = 25.4 mm = 2.54 cm SI Units
Total Heat kW = 1.20 x m3/s x Δh ( Enthalpy kJ/kg) 70 RE
25.0
25 -° 24.0
C 12
SEA LEVEL 20 25 0.60
23.0
0

IR
Pressure BAROMETRIC PRESSURE: 101.325 kPa

ENTHALPY - KJ PER KILOGRAM OF DRY AIR


°C
YA

VAPOR PRESSURE - MM OF MERCURY


22.0

E-
1 bar = 1x10 Pa (N/m ) = 10.20 m H2O = 0.98692• atm = 14.5038 psi (lbf/

DR
5 2
1.0 1.0 -• 60 0.65

UR
18

DEW POINT TEMPERATURE - °C


in2)

OF
21.0

AT
0.8 25

ER
1 mm water = 9.81 Pa (N/m ) 2

RA

0.90
11.7
2.0 0.70 20.0

MP
SENSIBLE HEAT Qs -4.6

OG
11
0.6 TOTAL HEAT Qt 4.0 0

TE
8 16 19.0
•- .0
-2.3

KIL
7.0
0.5 -4-8.0

N
50 0.75
Thermal Conductivity .0

TIO

HUMIDITY RATIO - GRAMS MOISTURE PER KILOGRAM DRY AIR


ER
20 18.0
-2.
0.4

JP

RA
-1.

20
0

1 W/(m K) = 0.5779 Btu/(ft h F) = 0.048 Btu/(in h F)


o o 0.0
-00.5.4

0
-
0.3

-0.3
-0.2

0.80
-0.1

17.0

-K

TU
0
0.2

4.7
0.1

14

SA
PY
0.85 16.0

AL
1.2

Velocity 40

TH
3.5

0.88
20 0.90 15.0 10

EN
0

%
2.3

1 ft/s = 0.3048 m/s 12

25
ENTHALPY •h 14.0
0.95

%
HUMIDITY RATIO •W

90
15 1.00 13.0
Volume 15
30

SENSIBLE HEAT RATIO = Qs / Qt


%
10 12.0

80
1 Gallon (U.S.) = 3.785 dm3 (liter) = 0.13368 ft3 = 0.8327 Imp. gal (UK)

0.86
11.0

%
15 90

70

VOL
10.0
Weight 10 8
20 10

UME
%
% 9.0
15

60
1 kg = 2.2046 lb
8.0

- CU
0.84
%
10 50 6
10

BIC
5 TY 7.0
IDI 5
Useful HVAC Formulas 0% HU
M

MET
4 E 6.0 80
0.82 LA TIV
0 RE

ER P
0 5 4 5.0
8%
30% 0
Water Quantity required for cooling or heating -1 4.0

ER K
0 6%
0.80

-5
q = h / (4200 Δt) 20% -5 3.0

G DR
-2
0 -10 -5 UMID ITY 4% 2
0.78

where LA TIVE H -10 2.0


10% RE

Y AIR
-15 -1 70
2%
0.76

q = water flow rate (m /s)


3 -20 -1 0 1.0
5
0.74

h = heat flow rate (kW or kJ/s)


-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55
Δt = temperature difference (oC)
DRY BULB TEMPERATURE - °C

-2 -1 0 10 20 30 40 50 60
0 0

76
TAKE ADVANTAGE OF A BROADER RANGE OF CAPABILITIES.
Al Salem Johnson Controls (ASJC) is a leading “one-stop-destination” for all integrated requirements; including HVAC&R Systems, Controls Systems, Building
Management Systems, Security, Safety and Fire Systems. In addition, to a full array of specialized Aftermarket Services, including but not limited to diverse customizable
service & maintenance contracts, rental solutions, BMS Services, Energy Audits, Chiller Replacement and others. Al Salem Johnson Controls worked on a number of high
profile projects in the region, some of which needed special customization and innovative solutions to adapt to unique circumstances or requirements of the project;
such as The Two Holy Mosques in Makkah & Madinah; the Clock Tower in Makkah; the New King Abdul Aziz International Airport in Jeddah.

BUILDING AUTOMATION
SYSTEMS

AIR SYSTEMS

SECURITY SYSTEMS

FIRE DETECTION &


FIRE PROTECTION SYSTEMS

BUILDING-WIDE SYSTEMS
INTEGRATION

77
After Sales Services and Beyond
Al Salem Johnson Controls Services team of experts work together to deliver the performance
you expect, and the efficiency you need. You will benefit from our combined expertise in Heating,
Ventilation, Air Conditioning & Refrigeration WITH +1,200 ENGINEERS AND TECHNICIANS, AL SALEM
(HVAC & R), Design, Mechanical, and Building Control Systems.
JOHNSON CONTROLS HAS THE LARGEST AFTER SALES
Our professionals are qualified to take a more holistic approach to solve problems quickly and
completely, ensuring your building is operating reliably and at optimal efficiency all the time. TEAM IN THE MIDDLE EAST

Offerings
1. Genuine Spare Parts 4. Replacement & Retrofits
We provide YORK® original equipment manufacturer (OEM) replacement parts in addition to A complete solution starting with Heat Load Calculation, Equipment Selection, Design of
non-YORK®, and universal spare parts that ensure your equipment will operate at maximum HVAC System and its accessories, supply, installation and commissioning of HVAC and Building
efficiency. Management Systems (BMS).

2. Maintenance Agreements Did you know that a new system can be 50% more efficient if the existing unit is more than
We offer different types of Maintenance Service Agreements for YORK and other brands.
® 12 years old? So a replacement is definitely a smart move to save asset and running costs.
We can cut your heating and cooling bills in half with our continuous advancements in cooling
technology that assists in energy efficiency as much as 7% per year.
3. Rental Solutions
Whether a chiller goes off-line for maintenance or your system suddenly goes down, Al Salem
Johnson Controls has a full range of YORK products and emergency protocol to handle any 5. Controls Solutions
situation in a fast, efficient and proactive manner.
Part of what we offer is; Energy Auditing, Extended Warranty and Green Building Design.

78
Smart Buildings Demand Smart Controls: Intelligent Solutions for Every Facility
Building Automation and Controls Security
For the professionals who design, build, and manage At Al Salem Johnson Controls, our vision is a world that’s
facilities, the desire to improve efficiency and effectiveness “safe, comfortable, and sustainable”—and our broad set of
is never-ending. innovative security products and services focuses on what
At Al Salem Johnson Controls, we make everything you need to make people, facilities, and assets safe.
from simple, configurable controls for specific kinds of We offer everything from access controls to intruder
equipment to highly programmable automation systems for prevention, from video surveillance to cybersecurity. By
entire facilities and campuses. having a global team in more than 150 countries, we
Our next-generation building automation systems make leverage the latest technologies to integrate our products
it possible to extend automated control to every building and services into comprehensive, holistic solutions. We
system—HVAC, lighting, security, and detection—on a single maximize safety, improve efficiency, and ensure business
platform. We also make control systems and components continuity, while at the same time innovating continuously
for commercial refrigeration equipment as well as a full line to offer leading-edge solutions.
of HVAC equipment.

Fire Safety Systems & Fire Suppression Smart Home


Fire safety is a fundamental mandate for every enterprise, Every homeowner values comfort and security—and we’ve
facility, campus, and municipality. Fire safety begins with been creating products to deliver both by applying our
fire detection, and fire detection means everything from prowess in commercial and industrial solutions to the
components—sensors, initiating devices, annunciators, and residential market. We provide you with award-winning
control panels—to integrated systems. home heating, cooling, and air quality systems—including
Aside from that, we configure, and install an unmatched sophisticated, intelligent thermostats—to help deliver
range of fire suppression systems including sprinklers and reliable, efficient climate control. Our residential solutions
valves, extinguishers and agents, special hazards systems, are smart, and they are getting smarter as we focus on
related components and fittings. two related goals: efficiency and automation. Sensor-based
controls and advanced technology can help make your
Fire detection and suppression solutions from Al Salem
home more comfortable, more secure, and more efficient—
Johnson Controls can help you meet your most vital
which is good for you and good for the planet.
mission: safety.

79
Local Manufacturing for a Sustainable Economy
Al Salem Johnson Controls is a key contributor to the localization of manufacturing and
development of the Saudi industrial sector, and a driving-force for HVAC technology-transfer to
Saudi from around the world. YORK Factory in Jeddah started its operation in 2001, it manufactures
Saudi-made Units with technologies transferred from the US, China and Italy. This is a key milestone
for local industry and job market, as ASJC is now manufacturing sophisticated HAVC equipment
such as chillers, air-handling and packaged units; reducing cost and lead-time. With the success of
this strategy, ASJC also exported a range of products to over 20 countries in the GCC, Middle East,
Asian and African.
2. Markets
Johnson Controls Manufacturing System (JCMS): JCI’s Global Path to Manufacturing Excellence In addition to the distribution of YORK’s Jeddah factory products in the Saudi market, the
factory exports a range of products to overseas markets in the GCC countries and Middle East,
Jordan, Lebanon, Africa, Egypt, Libya, also Yemen, Iraq, Turkey, India, Pakistan, & South Africa.
In 2017, YORK Jeddah Factory celebrated the achievement of Level 3 in Johnson Controls
Manufacturing System (JCMS) out of 5 level. It is ranked 13 in JCMS among all 95 JCI BT&S plants.
3. Certifications

Stable Operations
Customer Focus Environment

Zero Tolerance Organize Around


for Waste Pull
Quality Health & Safety
Management Management Systems
Systems Environmental
1. Current Factory
Management Systems
With a Man Power of 280+ and covering an area of 1M Sq.ft., it is considered the biggest YORK
factory in the Middle East. The factory produces Chillers (DX), Roof Top Pacakage Units (RTU),
Air Handling Units (AHU(=), Fan Coil Units (FCU) and Control Panels.
4. Localization & Training
Furthermore, to benefit the public and raise awareness on the importance of localizing industries
and jobs, the company is keen to transfer the latest international HVAC technologies to the
factory, as well as training local engineers and technicians to gain skills and expertise. It is
worth mentioning that the Research & Development Department within the factory enabled the
engineering, design and development of new a cooling technology for central air conditioning, to
be a Saudi developed and designed “technology” and not just Saudi “manufactured”.

5. New factory… Coming soon


To meet local and regional demand, ASJC has acquired a new state-of-the-art manufacturing
facility in King Abdullah Economic City, twice as large as the current one, including new
production lines, new technology transfer and new product testing facilities, a sound testing lab
and R&D Center.

80
Industrial Refrigeration
Al Salem Johnson Controls offers unique tailor-made solutions based on its comprehensive
experience within all industries and applications. We provide Design, Manufacture, Testing,
Installation and Start-up.

• Qualified & professional design engineering team with senior design engineers having in
excess of 30 years of experience.
• 3D system modeling as standard with automatic generated parts & BOMs, etc.
SABROE Industrial Refrigeration … Documented
• Unrivalled branded products: FRICK, SABROE & YORK.
performance, tangible benefits throughout
• Strategic alliances formed with professional MEP process contractors to align fully with major industrial cooling and heating
blue chip client expectations.
The SABROE brand has been in the business of
• The support & backing of a major international corporation for all building efficiency systems industrial cooling and heating ever since 1897.
including Industrial Refrigeration. We provide the equipment needed to put thermal
• Innovative approach to system design, always with high added value to clients in terms of transfers to work in industrial and commercial
economic outlay and efficient operation. installations - from a full spectrum of refrigeration
• Full alignment with sustainability in refrigeration to suit environmental responsibility compressors of all kinds to industrial chillers and
heat pumps. SABROE products are recognized
and respected throughout the world for their
quality, long-term operating reliability and cost-
Knowing Customer Businesses effectiveness. Customers also reap the benefits
Industrial Refrigeration Solutions are applied in a diversity of sectors: of our consistent focus on low life cycle costs and
world-leading expertise in the use of naturally
occurring refrigerants.

Meat & Poultry Food, Beverage Dairy Industry


(Slaughterhouses (Fruit juices, Soft (Dairy, Milk & Fish Processing
& Meat storage) drinks & Bakeries) Cheese Factories) & Fishery
Frick® Refrigeration Equipment and Gas
Compression Systems to meet exceptional
demands
Industrial Refrigeration Systems from Al Salem
Johnson Controls work behind the scenes to meet
exceptional demands that you can rely on for critical
processes. Our innovative ammonia refrigeration
Chemical Industry equipment and gas compression technology does
Ice Rinks (Snow Others (Marine
(Chemical, this by keeping food and beverage processing safely
Cold Stores domes & Ice & Climatic test
Petrochemical & chilled, natural gas moving through pipelines and
skating rinks) chambers)
Pharmaceutical) industrial process equipment working smoothly.

81
Energy Efficiency for a Sustainable Future

Al Salem Johnson Controls hosts a portfolio of smart, secure and customized energy solutions to 3. Lighting Solutions
further enhance the performance of your business and well-being of our planet. Using LED bulbs contributes to an average savings of up to 40% load. Lasts up to 10 times as
As a certified Energy Services Company (ESCO) from Saudi Energy Efficiency Center we provide a long as conventional incandescent light.
range of energy efficiency solutions to optimize energy performance of your facility and save money
on energy cost.
4. Central Plant Optimization (CPO)
Planned service program built around your specific building performance requirements, keeping
Emissions HVAC equipment and controls performing at optimum levels with a combination of scheduled,
The potential impact of energy efficiency on the economy is large, but it is also the least-cost way predictive and measurable preventive maintenance services. Ongoing maintenance reduces
of meeting emission reduction targets. operating cost, carbon footprint, equipment downtime and consequently increases equipment
lifetime, overall efficiency and comfort level.
Sustainable Solutions
Whether you are managing a facility in the public sector, education, retail industry, food and 5. Renewable Energy Solutions
beverages, banking, hospitality, restaurants, healthcare or manufacturing, typical energy Our nation has been blessed with Plethora of Sun; which makes the Renewable Energy both
performance improvements for your project include enhancements to heating, ventilating and Solar Photovoltaic and Solar Thermal very viable. Al Salem Johnson Controls will evaluate the
air-conditioning systems, lighting, and electrical systems, control systems, motors and pumps, and right options for your facility; which will enable you to produce energy for your own use, and
eliminating leaks and waste. be less dependent on the grid. Solar PV not only produces clean and reliable energy, but also
Here are our top 5 energy solutions to help you save a fortune: protects your business against the rising electricity cost. Renewable Energy reduces pollution,
preserves our natural resources and strengthens our commitment to our planet’s future.

1. HVAC Upgrades
HVAC equipment accounts for over 60% of the total energy consumed in buildings. The older
the equipment, the lower the efficiency. Selecting the right unit and capacity helps increase
efficiency.

2. Building Management System Upgrades


Implementing or retrofitting a powerful Building Management System & Controls that matches YORK® YK Water Cooled Chiller YORK® YVAA Air Cooled Chiller
the energy needs of given space with the amount of energy delivered, help in up to 15%
reduction on overall energy consumption. It empowers you with real-time data to take
immediate knowledge-based decisions to achieve your mission.

82
Energy Efficiency Improvements Guaranteed Performance

Save up to 30%-40% on Energy Cost with Guaranteed Savings

All of the energy and operational savings are guaranteed by the ESCO over the term of the contract.
If the guaranteed savings are not realized, we pay you the difference between what is saved and the
guaranteed savings amount. Using performance contracting, the risk of performance belongs to us.
We shoulder complete turn-key responsibility for the project, including the performance of
preliminary energy audits, detailed design and engineering, business case analysis, installation,
commissioning, performance measurement and verification. These projects typically include a
variety of building improvements including lighting and mechanical system retrofits, technology
upgrades, renewable energy installations, water efficiency upgrades, operator training, and
occupant education.

Measurement and Verification


A significant benefit of using performance contracting as a project delivery method is the
programmatic component of the annual validation of customer savings. Measurement and
verification ensure projects are successfully managed. This critical component of the performance
contracting program provides customers with the annual data to share for the life of the contract.

Smart Showrooms For Smart Energy


Integrated Approach Consumption | Controls Retrofitting
Al Salem Johnson Controls uses performance contracting for a comprehensive approach by analyzing
Due to regional increase on energy
all parts of a building environment – lighting, HVAC systems, building management systems, water
usage at an average rate of %8 annually,
efficiency, etc. to maximize the efficiency, savings and carbon reductions. This distinguishes ESCOs
companies started seeking solutions
from most contractors who focus on a core competency or single portion of an efficiency project, such
for reduction and saving on sources.
as lighting.
Accordingly, one of the well reputed automotive
companies in KSA, Mohamed Yousuf Naghi Motors
Co. agreed with Al Salem Johnson Controls (YORK) to
install smart technology for energy conservation onto
PERFORMANCE
its showrooms Air conditioning and lighting utilities.
CONTRACTING We have installed the smart control thermostats
PROJECT WITH which were able to save on electricity across most of
ENERGY AND selected showrooms in Jeddah and Riyadh, including:
OPERATIONAL “BMW”, “Rolls Royce”, “Mini-Cooper”, “Range Rover”,
SAVINGS LEAD “Porsche” and “Jaguar”. Al Salem Johnson Controls
successfully achieved up to %40 savings in energy
SIGNIFICANTLY
consumption across the showrooms using the best
HIGHER RETURN in quality and latest technology with an accessible
ON INVESTMENT network anywhere anytime.

83
Landmark Projects
Building on the reputation of Johnson Controls as the
global front-runner in the building efficiency industry,
Al Salem Johnson Controls became a leader in
providing integrated solutions to prestigious landmark
projects locally and regionally. The Holy Mosque Bar Al Jissa
Makkah, Kingdom of Saudi Arabia Muscat, Sultanate of Oman
Building owners and operators, developers and
consultant engineers turn to Al Salem Johnson Controls
products and services to help bring the most technically
challenging and ambitious projects to reality.

Many examples of Al Salem Johnson Controls market


leadership can be found in major developments such
as skyscrapers, airports, hotels, hospitals, universities,
ministerial complexes, industrial, commercial and
residential buildings, demonstrating the widespread Prophet Muhammed (PBUH) Mosque Sabiha Gökçen International Airport
Al Madinah, Kingdom of Saudi Arabia Istanbul, Turkey
customer satisfaction with our products.

King Abdulaziz University (CUP2) Clock Tower Presidential Palace Bahrain Bay Mall of Egypt
Jeddah, Kingdom of Saudi Arabia Makkah, Kingdom of Saudi Arabia Abu Dhabi, United Arab Emirates Manama, Kingdom of Bahrain Giza, Egypt

Ministry of Education Children Cancer Hospital 57357 King Abdulaziz International Airport
Kuwait Cairo, Egypt Jeddah, Kingdom of Saudi Arabia

Al Waseel Hills The Dubai Metro Carousel Mall Moscow Kremlin Empure State Building
Riyadh, Kingdom of Saudi Arabia Dubai, United Arab Emirates Istanbul, Turkey Russia New York, USA

84
Fakeeh Hospital Jabal Omar Kuwait University
Jeddah, Kingdom of Saudi Arabia Makkah, Kingdom of Saudi Arabia Kuwait

Cleveland Clinic Zorlu Center Al Bustan Palace Hotel


Abu Dhabi, United Arab Emirates Istanbul, Turkey Muscat, Sultanate of Oman

Burj Khalifa Burj Al Mamlaka Sharjah International Airport King Abdullah Financial District
Dubai, United Arab Emirates Riyadh, Kingdom of Saudi Arabia United Arab Emirates Riyadh, Kingdom of Saudi Arabia

Petronas Twin Towers Cevahir Mall Children Cancer Hospital Princess Noura University Princess Tower
Kulala Lumpor, Malaysia Istanbul, Turkey Cairo, Egypt Riyadh, Kingdom of Saudi Arabia Dubai, United Arab Emirates

City Stars Complex Four Seasons Hotel Four Seasons Hotel Grand Hyatt Hotel Citystars Commercial/Residential Complex
Cairo, Egypt Lebanon Bahrain Dubai, United Arab Emirates Cairo, Egypt

85
Notes:

86
Notes:

87
We are in the business of building efficiency.
We create energy savings, healthier environments and operational savings for our partners,
including over 90% of world’s tallest buildings.

Burj Khalifa Taipei 101 International Commerce Center Greenland Financial Complex International Princess Tower Two International
Dubai Taipei Hongkong Nanjing Financial Center Dubai Financial Center
Guangzhou Hongkong

Makkah Royal Clock Tower Shanghai World Petronas Tower Willis Tower Trump Tower Al Hamra Tower
Saudi Arabia Financial Center Kuala Lumpur Chicago Chicago Kuwait
Shanghai

We reserve the right to change in part or in whole the specifications without prior notice.

Al Salem Johnson Controls


P.O. Box 15019 Jeddah 21444 - Saudi Arabia
Customer Care Center: 920003588
YORK.com.sa

© 2020 Al Salem Johnson Controls