FROM DATE: 01/09/2021

Mr. Parthiban Manickam,


Managing Director,
Caliber Virtual Technologies,
Salem – 636009.

Subject: Quotation for Regulation 2017 Renewable Energy Laboratory experiments.

Dear Sir/Madam,

We are greatly privileged to be given this chance to quote for New Renewable Energy
Laboratory Kit Equipment for your reputed institution. We have evaluated all the experiments
in detail, all the required items from Page 3 - 8 covers the 90% of syllabus of Renewable
Energy Laboratory - Regulation 2017, we came up with proposal for the same and the total
quotation for the experiments of Renewable Energy Laboratory is Rs. 1,89,000(Refer Page
10).

Hope you will find our offer most competitive and looking forward to receive a positive
reply and your valuable purchase orders at the earliest. For further Queries and comments please
feel free to contact us.

Yours truly,
For Cailber Virtual Technologies,
PARTHIBAN MANICKAM
1
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


RENEWABLE ENERGY SYSTEMS LABORATORY

LAB SYLLABUS

1. Simulation study on Solar PV Energy System.


2. Experiment on “VI-Characteristics and Efficiency of 1kWp Solar PV System”.
3. Experiment on “Shadowing effect & diode based solution in 1kWp Solar PV System”.
4. Experiment on Performance assessment of Grid connected and Standalone 1kWp Solar
Power System.
5. Simulation study on Wind Energy Generator.
6. Experiment on Performance assessment of micro Wind Energy Generator.
7. Simulation study on Hybrid (Solar-Wind) Power System.
8. Experiment on Performance Assessment of Hybrid (Solar-Wind) Power System.
9. Simulation study on Hydel Power.
10. Experiment on Performance Assessment of 100W Fuel Cell.
11. Simulation study on Intelligent Controllers for Hybrid Systems.

NOTE:

A. All the materials used in hardware setup are first quality materials.
B. Our quotation covers 90% of Anna university lab syllabus.
C. Reason for lowest quote: We are supporting many industrial real time products based
on Renewable like solar charge controller, Solar Street light and etc. All the design
and development (Inverter, MPPT charge controller and PV emulator) are done by
our own developers. We are not buying any products from others.
D. This Quotation includes for 5 Hardware Experiments and 5 Simulation Experiments.
We are not charging amount for 5 Simulations. We will provide the required Software
and files for running the Simulation Files.
2
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


DETAILED EXPLANATION ABOUT 11 EXPERIMENTS:

Out of 11 Experiments,

We provide 5 Simulation Experiments and 5 Hardware Experiments.

EXPERIMENT METHODOLOGY QUOTATION BY


NO CALIBER

1 SIMULATION USING MATLAB NO CHARGE

2 HARDWARE SETUP REFER PAGE 10

3 HARDWARE SETUP REFER PAGE 10

4 HARDWARE SETUP REFER PAGE 10

5 SIMULATION USING MATLAB NO CHARGE

6 HARDWARE SETUP REFER PAGE 10

7 SIMULATION USING MATLAB NO CHARGE

8 HARDWARE SETUP REFER PAGE 10

9 SIMULATION USING MATLAB NO CHARGE

10 NOT INCLUDED IN OUR NO SUPPLY FROM US


QUOTATION

11 SIMULATION USING MATLAB NO CHARGE

TOTAL COST Rs. 1,80,000


3
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


DETAILED DESIGN OF 5 HARDWARE EXPERIMENTS.

EX. NO: 2 Experiment on “VI-Characteristics and Efficiency of 1kWp Solar PV System”.

HARDWARE SETUP

COMPONENTS USED AND RATINGS

SL.NO REQUIRED COMPONENTS RATINGS

1 PV PANEL 330 WATTS(PV Emulator-


Optional)

2 AMMETER (DC) 0 – 50 AMPS

3 VOLTMETER(DC) 0 – 100 VOLTS

4 LAMP LOAD 500 WATTS


4
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


EX. NO: 3 Experiment on “Shadowing effect & diode based solution in 1kWp Solar PV
System”.

HARDWARE SETUP

COMPONENTS USED AND RATINGS

SL.NO REQUIRED COMPONENTS RATINGS

1 PV PANEL 330W + 330W(PV Emulator


- Optional)

2 VOLTMETER 0 – 100VOLTS

3 AMMETER 0 – 50 AMPS

4 LAMP LOAD 500 WATTS

5 DIODE BASED SOLUTION 10A04(10 AMPS)


5
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


EX. NO: 4 Experiment on Performance assessment of Grid connected and Standalone
1kWp Solar Power System.
HARDWARE SETUP

COMPONENTS USED AND RATINGS

SL.NO REQUIRED COMPONENTS RATINGS

1 PV PANEL 330 WATTS(PV Emulator -


Optional)

2 MPPT CHARGE CONTROLLER 1000 WATTS

3 DC VOLTMETER 0-100 VOLTS


6
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


4 DC AMMETER 0-30 AMPS

5 BATTERY 40AH 40AH

6 ONGRID INVERTER 1 KVA

7 STANDALONE INVERTER 1 KVA

8 AC VOLTMETER 0-300 VOLTS

9 AC AMMETER 0-10 AMPS

10 500 WATTS LOAD 500 WATTS

EX NO: 6 Experiment on Performance assessment of micro Wind Energy Generator.

HARDWARE SETUP

7
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


COMPONENTS USED AND RATINGS

SL.NO REQUIRED COMPONENTS RATINGS

1 WIND ENERGY SETUP 400 WATTS(12V)

2 PRIMEOVER COUPLING(EMULATOR) 400 WATTS

3 RECTIFIER UNIT 10A04(10 AMPS)

4 LAMP LOAD 500 WATTS

5 DC AMMETER 0-30 AMPS

6 DC VOLTMETER 0-100 VOLTS

EX NO: 8 Experiment on Performance Assessment of Hybrid (Solar-Wind) Power System.


HARDWARE SETUP

8
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


COMPONENTS USED AND RATINGS

SL.NO REQUIRED COMPONENTS RATINGS

1 PV PANEL 100 WATTS

2 WIND 400 WATTS

3 CHARGE CONTROLLER 1000 WATTS

4 BATTERY 40 AH

5 DC VOLTMETER 0-100 VOLTS

6 DC AMMETER 0-30 AMPS

7 INVERTER 1 KVA

8 AC VOLTMETER 0-300 WATTS

9 AC AMMETER 0-10 AMPS

10 LAMP LOAD 500 WATTS

TERMS & CONDITIONS

Service Warranty : 3 Years from the Kit Delivered date.


Delivery Period : 20 days from the date of your order.(Based
upon emergency either 15 or 10 days from the date of order)
Validity of this quotation : 10 days.
Service time : within 7 days of time.
Payment Mode : Advance payment as 50% of Total
Amount while issuing Purchase Order and other 50%
amount at the time of delivering all the materials.

Note: All the quoted materials are of first Quality.


9
Page

502-3, Angammal Colony, Near New Bus Stand, Salem-636009. www.calibertech.net

salemcaliberembeddedtech@gmail.com Contact: 7708954811, 7867014811


Note: Rs. 1,80,000 includes all the above mentioned Components, Meters, Connecting Wires,
Metal boxes, Transport charges, Installation and Exclusive of GST.

And including GST the Quotation is Rs.1,89,000.

All the required materials in 5 Hardware experiments are explained clearly in the above pages.

REQUIRED ITEMS

The below quotation includes all the required materials for each experiment.

EX. NO ITEM QTY PRICE PER AMOUNT


UNIT

1 PV panels - 330W, 24V 3 16500 49500

2 1KW On grid Inverter 1 25000 25000

3 MPPT controller 1 13000 13000

4 PV Emulator 1 35750 35750

5 Micro Wind Energy Generator 1 40000 40000


module

6 Potentiometer 5 20 100

7 Step-down transformer 5 130 650

230V/12-0-12V

8 PV panels - 100W, 24V 1 6000 6000

9 Battery storage system with 1 10000 10000

charge & discharge control

40Ah

Total Without GST 1,80,000

Total including GST 1,89,000