You are on page 1of 3

90'-0"

FLOOR PLAN NOTES

390 E CORPORATE DRIVE STE 112


A4.1
1. ALL STRUCTURAL LUMBER SIDED FOR #2 OR BETTER

MERIDIAN, ID 83642
1 DOUG FIR LARCH.

#208-283-3775
2. 2x EXTERIOR STUD FRAMING @ 16' O.C. W/ SINGLE BOTTOM
24'-0"
PLATE AND DOUBLE TOP PLATE.
3. 4x8 HEADERS IN ALL BEARING WALL OPENING UNLESS
OTHERWISE NOTED.
4. ALLOW FOR A 22' x 30' (MIN) ATTIC AND CRAWL SPACE
ACCESS.
5. ALL METAL CONNECTIONS TO BE SIMPSON CO. OR BETTER
18'-0" 6. 5/8" TYPE 'X' GYP BOARD @ ALL GARAGE COMMON
4'-0" 10'-0" 4'-0" WALLS AND CEILINGS APPLIED TO GARAGE SIDE AND
ALL WALLS, BEAMS, POSTS AND OTHER STRUCTURAL
MEMBERS SUPPORTING FIRE PROTECTED HORIZONTAL
30/60 SH 30/60 SH STRUCTURAL MEMBERS.
7. DOORS BETWEEN GARAGE AND DWELLING ARE TO BE SELF

7to
CLOSING AND TIGHT FITTING SOLID WOOD DOOR 1 3/8" THICK

2'-6"
16'-0" 7'-0" 18'-0" 33'-0" 16'-0" OR A DOOR W/ A FIRE PROTECTION RATING OF NOT LESS

30/30 PW
THAN 20 MINUTES.
28 6'-6" 7'-6" 3'-5" 6'-1" 6'-1" 3'-5" 8'-0" 8'-0" 8. 1/2" GYPSUM BOARD TO BE INSTALLED ON INSIDE WALLS OF
HOUSE.

(3)1 3/4"x11 7/8"


9. ALL WINDOWS TO HAVE BREATHER TUBES INSTALLED.

8'-0"

(3)1 3/4"x11 7/8"


COVERED 10. ROOF SYSTEM TO BE PRE-ENGINEERED MANUFACTURED
PATIO ROOF TRUSSES UNLESS OTHERWISE NOTED.
MASTER 2-30/50 SH 11. ALL CONSTRUCTION PRACTICES USED IN THE CONSTRUCTION

18'-0"
10 CEILING OF THIS DWELLING SHALL BE DONE IN ACCORDANCE W/ THE
BEDROOM

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
2018 WHERE APPLICABLE.

used for construction or any other purpose without prior written permission from Risen Home Design.
10' TRAY CEILING 12. VENT RANGE HOOD, FANS, AND DRYER TO OUTSIDE AIR.
2-30/60 SH
CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS
PRIOR TO COMMENCING WORK.

18'-0"
13'-7"
13. ALL RESCUE WINDOWS FROM SLEEPING AREAS MUST MEET
THE FOLLING REQUIREMENTS:
1. SHALL HAVE A NET CLEAR OPENING OF 5.1 SQ. FT.
4'-0" 8'-0" 4'-0" 2'-2" 4'-10" 28 2. MINIMUM HEIGHT OF 24".

7'-0"
DINING

12'-6 1/2"
3. MINIMUM WIDTH OF 20".

These Drawings contain confidential proprietary information and are the property
BEDROOM #2

12'-1"
9' CEILING 4. FINISHED SILL HEIGHT OF NOT MORE THAN 44".
9' CEILING

10'-2"
14. EXTERIOR DIMENSIONS ARE TO FACE OF STUD WALL. INTERIOR

SH SH
DIMENSIONS ARE TO FACE OF STUD WALL.
80/80 OVERHEAD DR.

17'-1 3/4"
12'-4 1/2" 5'-2" 15. ALL FURNACE SWITCHES, PILOTS, AND BURNERS TO BE MINIMUM
30/60 PW 60/60 PW 30/60 PW 18" ABOVE FINISHED FLOOR.

30/30 PW
4'-0"
4'-3 1/2" 5'-7 1/2" 5'-11"

2'-6"
28

1'-11"

5'-0"
30/40 SH
30

1'-3 1/2"
24 26

1'-5 1/2"
30 2'-6"
11'-7 1/2"

SEAT (TYP.)
30 SHEET NOTES
13'-0"

4'-2"

3'-0"
W.I.C. BATH#2
7'-7 1/2"

4'-7" 5'-5 1/2" 1 CRAWL SPACE ACCESS. COORDINATE WITH JOIST LAYOUT.

R&S
4'-9 1/2"
9' CEILING MIN. 18"x24"
MASTER

5'-1"

20/40 SH

1st FLOOR PLAN


8'-11"
BATHROOM 5'-0" 2
9' CEILING 4'-0" R&S ATTIC SPACE ACCESS. COORDINATE WITH TRUSS LAYOUT.

P.E. GIRDER TRUSS


3'-0"
WALK-IN MIN. 22"x30"
SHOWER
SHOWER

2'-4 1/2"
R&S

NAMPA, ID
SPEC#1
2'-8"
26
40/20 PW

R&S 26 GREAT ROOM

Range

24'-0"
3'-1"
11' TRAY CEILING

10'-3 3/4"
7'-2 1/2" 7'-0" 60 3 A4.0
A4.1 2 BATHROOM

DW
9'-11" 5'-11"
W.I.C.
11'-2 1/2"

BUILT-INS
R&S

26
KITCHEN

52'-0"
1
9' CEILING BEDROOM #3
REVISIONS

50/50 SL 2
7'-8"

12'-3 1/2"

11'-10"
11'-1" 7'-4 1/2" 6'-10"
13'-0"

9' CEILING

5'-4"
RV BAY

4'-0"

12/7/2023
1/1/2024
DATE
15' CEILING 3'-11 1/2"
STORAGE 23'-4"
R&S BELOW Refrigerator
28 6'-0" 5'-2" 5'-0" 3'-5 1/2" 3'-8 1/2" 4'-1" 5'-7" 6'-2"
26 6'-8 1/2"
STAIRS UP

24 Fireplace
Dryer

9'-3 1/2"
FURN

2'-0"
5'-0" 4'-7 1/2" BUILD-INS BUILD-INS 30
9' DROP CEILING
6'-8 1/2"
40/20 PW

6'-10 1/2"

UTILITY 7'-9 1/2" 2'-1"


52'-0"

7'-0 1/2"
Washer

7'-4"

9' CEILING 5S PANTRY 7'-9 1/2" 28

4'-10 1/2"
R&S

2'-1"
R&S
PIPE

3'-10 1/2"
3'-10 1/2"
5S
28
BALUSTER 26
BENCH

WH 30 3'-4"

40/20 SL
60

5'-6"
30 5S BATH#3
24
30
9' CEILING
8'-6" 4'-6 1/2" FLUSH

1'-11"
28

11'-8 1/2"
R&S 5S SHOWER
2'-1"

28
4'-5 1/2"

BEDROOM #5
60 30 ENTRY 9' CEILING
13'-0"

8'-0" 4'-0" W.I.C. AIR TRN.

15'-6 1/2"
12' TRAY CEILING

8'-3"
26
3'-0" 11'-11" 7'-7 1/2" 12'-9" 6'-0" 13'-4" 4'-0" 4'-1" 5'-7"

R&S
1

11'-4 1/2"
2 BED / OFFICE BEDROOM #4
9' CEILING R&S
13'-8 1/2"

BONUS ROOM LINE ABOVE 9' CEILING

12'-5 1/2"

12'-0"
40/20 PW

1'-0"
2 CAR GARAGE 30/80

7'-0"
9' CEILING
GLU LAM BEAM

SQ/FT.

PRELIMINARY ISSUES FOR REVIEW


PRELIMINARY ISSUES FOR REVIEW
13'-0" 10/60 PW 10/60 PW 2-30/50 SH
EQ EQ
16'-0"

24'-0"

LIVING AREA 3252 SF


3'-0"

GARAGE 536 SF
P.E. GIRDER TRUSS
RV BAY 842 SF
2-30/50 SH 2-30/50 SH COVERED PORCH 346 SF
COVERED PATIO 394 SF
13'-0"

5'-6" 5'-11 1/2" 3'-11" 9'-5 1/4" 6'-7 3/4" 7'-0" 7'-0"
BONUS ROOM 395 SF

DESCRIPTION
11'-5 1/2" 20'-0" 14'-0"

(2)1 3/4"x11 7/8"


45'-5 1/2" 6'-0"
(2)1 3/4"x11 7/8"

(2)1 3/4"x11 7/8"


(2)1 3/4"x11 7/8"

COVERED PORCH
8'-0"

NOTE: VERIFY ALL WINDOW/DOOR ROUGH OPENING AND


10'-0"

3'-6" 3'-6" HEADER HEIGHT AND THE SAME FOR TRIM PACKAGE. VERIFY
STANDARD HEIGHTS WITH CONTRACTOR BEFORE FRAMING.

NO.
A
B
2'-0"

120/140 OVERHEAD DR. SEE 2018 IRC

SHEET TITLE
2'-0"

(2)1 3/4"x11 7/8"

(2)1 3/4"x11 7/8"

180/80 OVERHEAD DR. R302.7 PROVIDE UNDERSTAIR PROTECTION AS REQUIRED


R302.11 PROVIDE FIREBLOCKING AS REQUIRED
4'-0"

R303.7 PROVIDE SWITCHING AND ILLUMINATION AS REQUIRED


2'-0" 12'-0" 1'-6 1/2"
R305 PROVIDE SUFFICIENT CEILING HEIGHTS 1st FLOOR
R311.7 MEET STAIRWAY REQUIREMENTS
15'-6 1/2" 2'-6" 18'-0" 2'-6" R312 MEET GUARD REQUIREMENTS PLAN
38'-6 1/2" 10'-4 1/2" 10'-0" 10'-4 1/2" 20'-8 1/2"
90'-0"
GENERAL CONDITIONS
2 DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1033
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
1st FLOOR PLAN NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE: 12/7/2023
1 1/4" = 1'-0"
A4.0
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME
CONDITIONS MAY ARISE DURING DESIGN. AND/OR
ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CHECKED BY: MM DATE: 12/7/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A3.0 B
R806 - PROVIDE ADEQUATE ATTIC VENTILATION.

390 E CORPORATE DRIVE STE 112


MERIDIAN, ID 83642
#208-283-3775
RV BAY
15' - 1 1/8"
10
12

5
12

ENTRY #2
12
5
87 is

00

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
13' - 1 1/8" 12

used for construction or any other purpose without prior written permission from Risen Home Design.
5

APPROX. HEIGHT
ENTRY #1

20'-9 1/16"
11' - 1 1/8"

1ST FLOOR PLATE


9' - 1 1/8"

These Drawings contain confidential proprietary information and are the property
margined
g
1
2
FRONT VIEW
1/4" = 1'-0"
O

ELEVATIONS
NAMPA, ID
SPEC#1
REVISIONS
STAIRS DOWN

12/7/2023
1/1/2024
DATE
12
5
3'-6"
1'-10 1/2"

12
5
12
28 5

5'-5" 4'-1 1/2" 2'-6 1/2"

a Match
28'-7 1/2"

BONUS ROOM
8' CEILING

PRELIMINARY ISSUES FOR REVIEW


PRELIMINARY ISSUES FOR REVIEW
RIGHT VIEW
3 1/4" = 1'-0"
13'-0"

DESCRIPTION
NO.
A
B
50/40 ARCH
6'-7" 6'-5" SHEET TITLE
13'-0"
ELEVATIONS
BONUS ROOM PLAN
1 1/4" = 1'-0"
GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1033
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE: 12/7/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
CONDITIONS MAY ARISE DURING DESIGN. AND/OR CHECKED BY: MM DATE: 12/7/2023
SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY DRAWING NUMBER: REV:
ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS
AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A4.0 B
390 E CORPORATE DRIVE STE 112
MERIDIAN, ID 83642
#208-283-3775
12
5

12
5

of Risen Home Design. These drawings are NOT to be reproduced, copied whole or in part, disclosed,
used for construction or any other purpose without prior written permission from Risen Home Design.
These Drawings contain confidential proprietary information and are the property
1st
BACK VIEW
1 1/4" = 1'-0"

ELEVATIONS
NAMPA, ID
SPEC#1
12
5

12
5 REVISIONS

12/7/2023
1/1/2024
DATE
LEFT VIEW
2 1/4" = 1'-0"

PRELIMINARY ISSUES FOR REVIEW


PRELIMINARY ISSUES FOR REVIEW
DESCRIPTION
NO.
A
B
SHEET TITLE

ELEVATIONS

GENERAL CONDITIONS
DRAWINGS & SPECIFICATIONS RHD PROJECT NUMBER: RHD-1033
IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES
NOTE: RISEN HOME DESIGN PLANS DO NOT CARRY AN FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING DRAWN BY: RMC DATE: 12/7/2023
ENGINEER'S AND/OR ARCHITECT'S STAMP(S) SOME ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND
3D VIEW CONDITIONS MAY ARISE DURING DESIGN. AND/OR SPECIFICATIONS AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN
CHECKED BY: MM DATE: 12/7/2023

3 CONSTRUCTION THAT MAY REQUIRE AN ARCHITECT'S AND/OR


ENGINEER'S STAMP TO COMPLY WITH LOCAL BUILDING
WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY
CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING
DRAWING NUMBER: REV:

CODES. THE CONTRACTOR IS TO VERIFY THESE CONDITIONS


AND SECURE REQUIRED STAMPS PRIOR TO CONSTRUCTION
ERRORS AND/OR OMMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE
ORIGINAL DRAWINGS. CONSULTANT'S LITABILITY IS THE SAME. A4.1 B