SHEET NOTES

1. FOR GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS, SEE SHEET A-101


..\..\Downloads\WhatsApp Image 2023-08-29 at 08.49.46.jpg

3. FOR WALL TYPES, SEE SHEET A-302


4. FOR DOOR AND WINDOW SCHEDULES, SEE SHEET A-601
5' 3'-4"
5. FOR MATERIAL AND FINISH SCHEDULE, SEE SHEET A-602
5. ALL DIMENSIONS ARE TO CENTERLINE GRID, CENTER OF WALL OR FACE OF FINISH

3'-6"

3'-6"
TYPE

TYPE
2'-6"

6'-8"

6'-8"
KEYNOTES

3'-2"

3'-2"
F
1 NEW ADDITIONAL INTERIOR WALL

TYPE

Archi Partners Design


4435 E Chandler Blvd
4'-8"
NET OPENING HEIGHT
FFL FFL

Phoenix, AZ 85048
2'-1 3/4"
2 KEYNOTE 1
Play Room Room 1, Room 2

LOCATION

LOCATION
Location: Location:

602-628-1231
3 KEYNOTE 1

6'-8"
Door Number: 01 Door Number: 02 2'-3"

Suite 200
2'
NET OPENING WIDTH
Construction: 1-3/4" T x 4-9/16" W Wood Door Frame (Rabbeted Stop) Construction: 1-3/4" T x 4-9/16" W Wood Door Frame (Rabbeted Stop) FFL

FRAME

FRAME
Finish: Painted Finish Finish: Painted Finish
Play Room, Room 1, Room 2
LEGEND:

LOCATION
Location:
Construction: 1-3/4" T x 5'-0" W x 6'-8" H Wood Flush Door Construction: 1-3/4" T x 3'-4" W x 6'-8" H Wood Flush Door

DOOR

DOOR
Window Number: 01
Finish: Painted Finish Finish: Painted Finish

LIBERTY HOME CARE RENOVATION


Construction: Aluminum Window Frames

FRAME
Match paint color finish with the existing doors Match paint color finish with the existing doors
Notes: Notes: Finish: Epoxy Resin Powder-coated Aluminum Finish 1"
- DIMENSION

GLAZING
Hinges: 0.18" T x 4 1/2" Ball-bearing Butt Hinge Hinges: 0.18" T x 4 1/2" Ball-bearing Butt Hinge Finish: 3/16" THK. Tempered Glass
Pull Handles: -None- Pull Handles: -None- Finishes for Hinges, Handles and Lock Set are TBD by owner.

IRONMONGERY

IRONMONGERY
Lock Set: TBD Lock Set: TBD
Notes: Color/Material of Insect Screen are TBD by owner.
FFL - FINISH FLOOR LINE

IRONMONGERY
Door Stop: Floor-mounted Half-moon 45mm Dia. x 30mm H Diecast Zinc Door Stop Door Stop: Floor-mounted Half-moon 45mm Dia. x 30mm H Diecast Zinc Door Stop Hinges: TBD
Flush Bolts: -None- Flush Bolts: -None- Handles: TBD TAG
- CALL-OUT TAG
Door Closer: Optional Door Closer: Optional Lock Set: TBD
Door Springs: -None- Door Springs: -None- Screen: Optional

DOOR NOTES

1 ACCESSIBILITY DETAILS 2 DOOR SCHEDULE 3 WINDOW SCHEDULE 1. SELECT APPROPRIATE WOOD TYPE BASED ON APPLICATION (INTERIOR/EXTERIOR) AND
DESIRED AESTHETICS.
SCALE NTS SCALE 1:50 FT SCALE 1:50 FT 1. LAY OUT ALL COMPONENTS AND ENSURE SQUARENESS BEFORE ASSEMBLY.
2.PRE-DRILL HOLES TO PREVENT WOOD FROM SPLITTING DURING SCREW INSTALLATION.
INTERIOR WALL PARTITION INTERSECTION DOOR OPENING DIAGONAL STABILITY BRACING ANCHORAGE 3. USE APPROPRIATE FASTENERS (SCREWS OR NAILS) FOR THE WOOD TYPE AND
TOP TRACK APPLICATION.
4. SAND THE DOOR SMOOTH BEFORE APPLYING A STAIN OR PAINT FINISH.
5. APPLY MULTIPLE THIN COATS OF FINISH FOR BEST RESULTS.
JOINT REINFORCEMENT METAL STUD
LATERAL STABILITY STRAP OR
NOTCHED ANGLE, AS REQUIRED
CRIPPLE STUD BY DESIGN (EACH SIDE) SCREW STRAP TO EACH STUD
2" MAX

CLOSURE TRACK EXTENDED


ABOVE OPENING, AS REQUIRED
FOR STRENGTH
MULTIPLE MEMBERS, AS
REQUIRED, AT ENDS WINDOW NOTES
HEAD TRACK
1. COMPLY WITH AAMA/NWWDA 101/I.S. 2-11 SPECIFICATIONS FOR CLASS C-AW100.
2.USE 6063-T5 ALLOY EXTRUDED ALUMINUM FOR FRAMES.

NOTES & INFORMATION


MULTIPLE STUDS, STRUCTURAL ANGLE
BOTTOM TRACK, 3. TEMPERED GLASS CONFORMING TO CPSC (CONSUMER PRODUCT SAFETY COMMISSION)
BACK TO BACK, AS REQUIRED AND ANCHOR BOLTS,
AS REQUIRED
GAUGE AS REQUIRED TO STANDARDS FOR SAFETY GLAZING. FOR TEMPERED GLASS USED IN WINDOWS, THE
TRANSFER LOADS
BOTTOM TRACK RELEVANT CPSC STANDARD IS CPSC 16 CFR 1201, WHICH SPECIFIES REQUIREMENTS FOR
INSULATION 2 X 3-5/8 METAL STUD FRAMING AT 16" O.C. 5/8 GYPSUM BOARD FASTENERS, AS REQUIRED SCREWS AS REQUIRED GLAZING MATERIALS USED IN BUILDING PRODUCTS.
THROUGH BOTTOM
TRACK AT EACH JAMB STUD 4. GLAZING TYPE: TBD BY OWNER (E.G., CLEAR, TINTED, FROSTED)

TYPICAL INTERIOR WALL PARTITION WALL BRIDGING GENERAL NOTES


1. ALL WORK SHALL COMPLY WITH THE LATEST BUILDING CODES AND MANUFACTURER'S SPECIFICATIONS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND INSPECTIONS.
3. PROTECT EXISTING FINISHES AND SURFACES FROM DAMAGE DURING CONSTRUCTION.
1'-4" 4. MAINTAIN A CLEAN AND SAFE WORK ENVIRONMENT.
5. VERIFY EXISTING FIELD DIMENSIONS BEFORE CONSTRUCTION BEGINS.
SOLID BLOCKING (LOCATE BLOCKING AT 6. NOTE THAT FIELD VERIFICATION MAY RESULT IN MINOR ADJUSTMENTS TO THE PLANS.
EACH END OF WALL, ADJACENT TO SCREW, AS REQUIRED AT EACH STUD 7. ALL WINDOWS SHALL BE DOUBLE-GLAZED AND LOW-EMISSIVITY (LOW-E) FOR IMPROVED ENERGY EFFICIENCY.
OPENINGS, AND AS REQUIRED
8. PAINT FINISH IN REMODELED AREAS SHALL BE MATCH THE EXISTING PAINT IN ADJACENT AREAS.

FLAT STRAPS, NOTCHED


CHANNEL, X BRIDGING, OR
PROPRIETARY BRIDGING (EACH SIDE);
LAP SPLICE STRAPS 4" MIN

INSULATION 2 X 3-5/8 METAL STUD FRAMING AT 16" O.C. 5/8 GYPSUM BOARD SCREWS, AS REQUIRED
(EACH SIDE)
CONSTRUCTION NOTES
1. FLASH ALL WINDOWS AND DOORS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2.DOUBLE CHECK FLOOR LEVEL DATUM BEFORE FRAMING WALLS TO ENSURE PROPER DOOR CLEARANCES.
3. NEW INTERIOR WALL PARTITION:
3.1. USE 2 X 3-5/8 STUDS FOR FRAMING, SPACED 16 INCHES ON CENTER.
3.2. INSTALL 5/8" DRYWALL ON BOTH SIDES OF THE PARTITION WALL.

4 INTERIOR
SCALE
WALL TYPE-1 DETAIL
1:5 FT 5 INTERIOR
SCALE
WALL FRAMING DETAIL
NTS
3.3. FINISH DRYWALL SURFACE WITH A SMOOTH FINISH, READY FOR PAINTING.
3.4. COORDINATE WITH THE PAINTING CONTRACTOR FOR THE APPLICATION OF PAINT ON BOTH SIDES OF THE
WALL.
3.5. INSTALL SOUNDPROOFING INSULATION BETWEEN WALLS OF ADJOINING ROOMS FOR NOISE REDUCTION.
FLOOR BASE NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING
ROOM NO. ROOM NAME REMARKS 4. SCHEDULE INSPECTIONS WITH LOCAL BUILDING DEPARTMENT AS REQUIRED BY THE CONSTRUCTION TIMELINE.
MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH HEIGHT 5. CONDUCT A FINAL INSPECTION OF ALL WINDOWS AND DOORS FOR PROPER OPERATION AND WEATHERPROOFING.
6. SCHEDULE A FINAL WALKTHROUGH WITH THE HOMEOWNER TO ADDRESS ANY PUNCH LIST ITEMS BEFORE 04/26/24
EXISTING EXISTING EXISTING EXISTING PAINTED EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING ANY FINISHES AFFECTED BY THE RENOVATION WORK WILL BE
14 PLAY ROOM GYPSUM BOARD PROJECT COMPLETION.
(NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (COLOR TO MATCH WITH EXISTING) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) REPAIRED TO MATCH THEIR EXISTING CONDITION
7. PERFORM A FINAL CLEANING OF THE ENTIRE BUILDING UPON COMPLETION OF CONSTRUCTION.
EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING PAINTED PAINTED EXISTING EXISTING EXISTING EXISTING EXISTING ANY FINISHES AFFECTED BY THE RENOVATION WORK WILL BE
20a ROOM 1 GYPSUM BOARD GYPSUM BOARD
(NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (COLOR TO MATCH WITH EXISTING) (COLOR TO MATCH WITH EXISTING) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) REPAIRED TO MATCH THEIR EXISTING CONDITION

EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING PAINTED EXISTING EXISTING PAINTED EXISTING EXISTING EXISTING ANY FINISHES AFFECTED BY THE RENOVATION WORK WILL BE
20b ROOM 2 GYPSUM BOARD GYPSUM BOARD
(NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (COLOR TO MATCH WITH EXISTING) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (COLOR TO MATCH WITH EXISTING) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) REPAIRED TO MATCH THEIR EXISTING CONDITION

EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING ANY FINISHES AFFECTED BY THE RENOVATION WORK WILL BE
13 BATH 2 (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) (NO CHANGE - VERIFY ACTUAL) REPAIRED TO MATCH THEIR EXISTING CONDITION
A-601
6 MATERIAL
SCALE
AND FINISHES SCHEDULE
NTS