Scale parameters and functions

6.18 DR 18 digital output control specifications

6.18 DR 18 digital output control specifications

6.18.1 Overview
If a digital output is defined in data record DR 7 for control with data record DR 18 (see
Assignment for digital output 0, 1, 2, 3 (Page 89)), you can control this output with data
record DR 18. Transfer is always for all four digital outputs. Only outputs which have been
configured for control via DR 18 (see DR7 interface parameters (Page 86)) are activated or
deactivated according to the content of data record DR 18.

Procedure
● Check or adapt the desired parameter settings of the digital outputs in data record 7
● Define the value for digital output 0, 1, 2, 3
● Transfer the data record to the scales

Table 6- 16 Assignment of data record 18

Variable Note Type Length RW Default Min. Max. Modbus reg-


(bytes) isters
Data record Contains no. of data USHORT 2 r 18 - - 1606
number record
Length Data record length in- USHORT 2 r 12 - - 1607
formation
Application Information about which USHORT 2 r 141 - - 1608
application the DR be-
longs to
Version ID Information about the USHORT 2 r 1 1 65635 1609
current data record
version
Specification Specification of digital BIT 0 rw 0 0 1 1610.16
for digital output 0=1 -> DA0 out-
output 0, 1, put active
2, 3 (only if assignment
(Page 109) Code 21 is assigned to
the output, see DR 7)
Specification of digital BIT 0 rw 0 0 1 1610.15
output 1=1 -> DA1 out-
put active
(only if assignment
Code 21 is assigned to
the output, see DR 7)
Specification of digital BIT 0 rw 0 0 1 1610.14
output 2=1 -> DA2 out-
put active
(only if assignment
Code 21 is assigned to
the output, see DR 7)

SIWAREX WP521/WP522
108 Manual, 04/2016, A5E36695225A