MH1 MH2
1845
ANOXIC TANK
"I hereby certify that these works have been designed by me in accordance with sound engineering practice and that I take
full responsibility for the design and performance of the same."
BUU/2024/PTP/MNA/MQ- 01 00
SUBMISSION
EXISTING ADMINISTRATION BUILDING
SECTION A- A
INCOMING CHAMBER, PRIMARY SCREEN CHAMBER, BLOWER ROOM
WET WELL & DRY WELL
300 300
750 1500
475
400 500
500
150
1200
2150
700
400
4750
3825
950
5°
1000
GRAVITY SLUDGE THICKENER
300
6355 2600 6355
SECTION T1-T1
SECTION T1-T1
BUU/2024/PTP/MNA/MQ- 02 00
SUBMISSION
B
NEW
SCADA
ROOM
NEW
SCADA
ROOM
A A
SECTION B - B
SECTION A- A
"I hereby certify that these works have been designed by me in accordance with sound engineering practice and that I take
full responsibility for the design and performance of the same."
BUU/2024/PTP/MNA/MQ- 03 00
SUBMISSION
DESIGN, CONSTRUCT, COMMISSION AND HAND
OVER OF SEWAGE TREATMENT PLANT PHASE 2
MODULE 3 - 7,300 PE (ULTIMATE CAPACITY 22,000
PE) AND ASSOCIATED WORKS ON LOT 1993-2005,
2297-2334 & 262 AT ZONE A, BANDAR UDA UTAMA
MUKIM PULAI, DAERAH JOHOR BAHRU, JOHOR
DARUL TAKZIM.
EXISTING AERATED EXISTING AERATED EXISTING FOR UDA LAND (SOUTH) SDN BHD
"I hereby certify that these works have been designed by me in accordance with sound engineering practice and that I take
full responsibility for the design and performance of the same."
SUBMISSION
GRAVITY SLUDGE THICKENER TANK
SECTION C - C
SIDE VIEW
"I hereby certify that these works have been designed by me in accordance with sound engineering practice and that I take
full responsibility for the design and performance of the same."
SUBMISSION
300 300
750 1500
300
475
150
3000
4450
3825
300
300 1500 300
300
SLUDGE RETURN PUMP SUMP
SECTION J - J
900
1845
4500
300
300
300 S.B.B.U SDN. BHD.
300
3000
0
DISINFECTION CHAMBER
LAYOUT PLAN
SECTION T-T
300 300
750 1500
150
25 25
500
400
250
700
475
400 500
500
SECTION N - N
150
1200
SECTION 1-1
2150
700
400
4750
3825
950
5°
500
400
N N
1000
400
400
300
700 "I hereby certify that these works have been designed by me in accordance with sound engineering practice and that I take
150 150
full responsibility for the design and performance of the same."
6355 2600 6355 CROSS SECTION FOR CLARIFIER COLUMN
CROSS SECTION FOR CLARIFIER COLUMN
15300 300
300 SECTION L - L
SECONDARY CLARIFIER (7300 PE)
DISINFECTION CHAMBER &
LAYOUT PLAN & CROSS SECTION
BUU/2024/PTP/MNA/MQ- 06 00
SUBMISSION
1 2 3 4
A A
3 2 1 4
A
A
B B
BLOWER ROOM
ROOF PLAN FOR UDA LAND (SOUTH) SDN BHD
( 1ST AND 2ND MODULE )
FLOOR PLAN
ELEVATION B
"I hereby certify that these works have been designed by me in accordance with sound engineering practice and that I take
full responsibility for the design and performance of the same."
ADMIN BUILDING
LAYOUT PLAN & ROOF PLAN
BLOWER ROOM
LAYOUT PLAN & ROOF PLAN
BUU/2024/PTP/MNA/MQ- 07 00
SUBMISSION