You are on page 1of 13

lOMoARcPSD|41112317

2- Storey Residential Building Palmario-2

Building Design 1 (Technological Institute of the Philippines)

Scan to open on Studocu

Studocu is not sponsored or endorsed by any college or university


Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)
lOMoARcPSD|41112317

SITE HERE

LAND USE AND ZONING

5.00 1.00 1.00 7.30


3.90

LINE AND GRADE


10.00

2.20

1.90
3.90

ARCHITECTURAL
0.90
0.90

0.90

STRUCTURAL
9.20

9.20

SANITARY

1.00
5.00 1.00 1.00 7.30

ELECTRICAL

MECHANICAL
PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: SITE DEVELOPMENT PLAN


CS
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
ARCHITECT / ENGINEER CHECKED BY: VICINITY MAP
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR PERSPECTIVE


1 1
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

5.00 5.00

1.60 3.40 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30

1.90

1.90

1.90

1.90
1.00

1.00
2.00

2.00
2.10

2.10
1.10

1.10
10.00

10.00

10.00

10.00
1.10

1.10
2.10

2.10
2.00

2.00
1.00

1.00
1.90

1.90

1.90

1.90
0.90

0.90

0.90

0.90
0.90

0.90

0.90

0.90
9.20

9.20

9.20

9.20
1.00 1.00
1.60 3.40 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30
3.40
5.00 5.00

0.60
1.20 0.80
0.90 0.80 0.70
0.40 0.40 0.40 0.40 0.40

0.60
0.30

0.30 0.70 0.30


1.30

1.30
1.00
2.10

2.10

2.10

1.80
0.80

0.80
PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: GROUND & SECOND FLOOR PLAN


A
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
ARCHITECT CHECKED BY: SCHEDULE OF DOORS & WINDOWS
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR

1 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

5.00 5.00

5.00 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30

1.90

1.90

1.90

1.90
3.90

1.00

1.00
2.00

2.00
2.10

2.10
1.10

1.10
10.00

10.00

10.00

10.00

10.00
2.20

1.90

1.10

1.10
2.10

2.10
2.00

2.00
1.00

1.00
3.90

1.90

1.90

1.90

1.90
0.90

0.90

0.90

0.90

0.90
0.90

0.90

0.90

0.90

0.90

0.90
9.20

9.20

9.20

9.20

9.20

9.20
1.00 1.00 1.00
5.00 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30
5.00 5.00

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: ROOF DECK PLAN


A
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
ARCHITECT CHECKED BY: REFLECTED CEILING PLAN
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR

2 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

5.00 10.00
1.60 3.40 1.00 3.90 2.20 3.90 0.90 0.90

1.00
1.00

3.00
3.00

7.20
7.20

3.00
3.00

0.20
0.20

10.00 5.00
0.90 0.90 3.90 2.20 3.90 1.60 3.40 1.00
1.00

1.00
3.00

3.00
7.20

7.20
3.00

3.00
0.20

0.20
5.00 10.00
1.00 3.40 1.60 3.90 2.20 3.90 3.46
1.00

1.00
3.00

3.00
7.20

7.20
3.00

3.00
0.20

0.20

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: SECTION THRU X - X


A
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
ARCHITECT CHECKED BY: SECTION THRU Y-Y
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR FRONT & REAR ELEVATION
3 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO. LEFT & RIGHT ELEVATION

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

5.00 5.00 5.00

1.60 3.40 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30

3.90

3.90

3.90

3.90

3.90

3.90
10.00

10.00

10.00

10.00

10.00

10.00
2.20

2.20

2.20

2.20

2.20

2.20
3.90

3.90

3.90

3.90

3.90

3.90
0.90

0.90

0.90

0.90

0.90

0.90
0.90

0.90

0.90

0.90

0.90

0.90
9.20

9.20

9.20

9.20

9.20

9.20
1.60 3.40 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30 1.60 3.40 1.00 1.00 7.30
5.00 5.00 5.00

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: GROUND FLOOR FOUNDATION PLAN


S
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
STRUCTURAL CIVIL ENGINEER CHECKED BY: SECOND FLOOR FRAMING PLAN
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR ROOF DECK FRAMING PLAN
1 2
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317


0.10

h 0.5
VERIFY

L = varies
L1/4 L1/4 L2/4 L2/4

LANDING B
S

T
T

0.05
=
va
rie
s
SECTION SECTION
0.23m 0.5

CANTILEVER L1 L2

0.20m
1200 1200
B

200

h = varies
0.25m
1200

1200
400
D

S/3 + 120mm S/3 + 120mm

0.80m

T
PLAN
PLAN C1-F1 PLAN, C1-F1, C2-F1
S/4 - 120mm
S/4 - 120mm
S (CLEAR SPAN)

5'' THK. CHB. 5'' THK. CHB.


VERIFY
VERIFY

200 200 200 200


(min) (min) (min) (min)

OPEN

TB

BB

150
SECTION X

0.30 0.30

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: STRUCTURAL DETAILS


S
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
STRUCTURAL CIVIL ENGINEER CHECKED BY:
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR

2 2
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

LEGENDS AND SYMBOLS:

100 800 100 1000


0.43
100

100mmØ
DRAIN PIPE
100mmØ
800

DRAIN PIPE
2.55
100

0.14
0.43

PLAN
150mmØ SECTION
DRAIN PIPE

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: CLEAN WATERLINE LAYOUT


P
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
SANITARY ENGINEER CHECKED BY: PLUMBING DETAILS
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR

1 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

LEGENDS AND SYMBOLS:

.15 1.30 .15 .80 .15 .80 .15


EXPANSION FLAT BAR
SHIELD WITH BOLT

CONC. WALL VERTICAL PIPE


0.30

1.50
EXPANSION SHIELD
PIPE SIZES FLAT BAR
WITH BOLT
50 TO 100 Ø 40 x 3 12
2.50
125 TO 150 Ø 50 x 6 16
200 Ø & UP 65 x 6 20

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: SANITARY LAYOUT


P
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
SANITARY ENGINEER CHECKED BY: DETAILS OF SEPTIC TANK
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR PLUMBING DETAILS


2 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

LEGENDS AND SYMBOLS:

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: PLUMBING ISOMETRIC LAYOUT


P
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
SANITARY ENGINEER CHECKED BY:
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR

3 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

ELECTRICAL SYSTEM GENERAL NOTES LEGENDS AND SYMBOLS:

ELECTRICAL PANEL DUPLEX CONVENIENCE OUTLET


BOARD
ELECTRICAL SERVICE
WP
WEATHERPROOF DUPLEX CONVENIENCE OUTLET
ENTRANCE
CIRCUIT HOMERUN
ACU
AIRCONDITIONING UNIT OUTLET

R
RANGE OUTLET
CUIRCUIT BREAKER
REF
REFRIGERATOR UNIT OUTLET
KILOWATT/HOUR
METER
WH
WATER-HEATER UNIT OUTLET
SURFACE MOUNTED SQUARE TYPE LED LIGHT FIXTURE 100w
(n)
SINGLE POLE SWITCH
SURFACE MOUNTED CIRCULAR LED LIGHT FIXTURE 100w
(n,n )
TWO GANG SWITCH

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: LIGHTING AND SWITCH LAYOUT PLAN


E
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
ELECTRICAL ENGINEER CHECKED BY:
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR

1 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

LEGENDS AND SYMBOLS: PANEL ID : PB-1


LOCATION : GROUND FLOOR-KITCHEN
MAIN : 50 AT, SINGLE PH., 230VOLTS
ELECTRICAL PANEL ENCLOSURE : NEMA 1 WALL MOUNTED
BOARD
CKT. TOTAL WATTS AMPERE NO. Ø SIZE OF HOMERUN
ELECTRICAL SERVICE VOLTS DESCRIPTION AT
NO. NO. LOAD WIRE IN CONDUIT
ENTRANCE
CIRCUIT HOMERUN 1 230 LIGHTING 10 1000 4.35 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
2 230 CONVENIENCE OUTLET 6 1200 5.22 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
3 230 RANGE 1 3500 15.23 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
CUIRCUIT BREAKER
4 230 REFRIGERATOR 1 1200 5.22 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
5 230 ACU 1 932.5 4.06 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
KILOWATT/HOUR
6 230 SPARE
METER
7 230 SPARE
SURFACE MOUNTED SQUARE TYPE LED LIGHT FIXTURE 100w 8 230 SPARE
TOTAL 7,832.5 34.08
SURFACE MOUNTED CIRCULAR LED LIGHT FIXTURE 100w Computation: DEMAND FACTOR APPLICATION : 80%*7,832.5=6,266 WATTS
TOTAL CONNECTION LOAD + 25% OF THE LARGEST MOTOR = 7,141 WATTS

DUPLEX CONVENIENCE OUTLET IT = 7,141 WATTS/230V USE : 2P 50A FOR CIRCUIT BREAKER,
IT = 31.05 AMPS
2-8.00mm SQ. THW, 1-3.5mm TW in 40mm Ø RSC
WP
WEATHERPROOF DUPLEX CONVENIENCE OUTLET PROTECTION: USE 100AT/100AF, 2P 230 V, 60Hz, 10A
ACB IN NEMA ENCLOSURE
ACU
AIRCONDITIONING UNIT OUTLET
PANEL ID : PB-2
R
RANGE OUTLET LOCATION : GROUND FLOOR-KITCHEN
MAIN : 50 AT, SINGLE PH., 230VOLTS
REF
REFRIGERATOR UNIT OUTLET ENCLOSURE : NEMA 1 WALL MOUNTED
WH
WATER-HEATER UNIT OUTLET CKT. TOTAL WATTS AMPERE NO. Ø SIZE OF HOMERUN
VOLTS DESCRIPTION AT
NO. NO. LOAD WIRE IN CONDUIT
(n)
SINGLE POLE SWITCH 1 230 LIGHTING 10 1000 4.35 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
2 230 CONVENIENCE OUTLET 6 1200 5.22 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
(n,n )
TWO GANG SWITCH 3 230 RANGE 1 3500 15.23 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
4 230 REFRIGERATOR 1 1200 5.22 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
5 230 ACU 1 932.5 4.06 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
6 230 SPARE
7 230 SPARE
8 230 SPARE
TOTAL 7,832.5 34.08
Computation: DEMAND FACTOR APPLICATION : 80%*7,832.5=6,266 WATTS
TOTAL CONNECTION LOAD + 25% OF THE LARGEST MOTOR = 7,141 WATTS
IT = 7,141 WATTS/230V USE : 2P 50A FOR CIRCUIT BREAKER,
IT = 31.05 AMPS
2-8.00mm SQ. THW, 1-3.5mm TW in 40mm Ø RSC
PROTECTION: USE 100AT/100AF, 2P 230 V, 60Hz, 10A
ACB IN NEMA ENCLOSURE

PANEL ID : PB-3 PANEL ID : PB-4 PANEL ID : PB-5


LOCATION : OUTSIDE STAIR LOCATION : GROUND FLOOR-KITCHEN LOCATION : GROUND FLOOR-KITCHEN
MAIN : 50 AT, SINGLE PH., 230VOLTS MAIN : 50 AT, SINGLE PH., 230VOLTS MAIN : 50 AT, SINGLE PH., 230VOLTS
ENCLOSURE : NEMA 1 WALL MOUNTED ENCLOSURE : NEMA 1 WALL MOUNTED ENCLOSURE : NEMA 1 WALL MOUNTED

CKT. TOTAL WATTS AMPERE NO. Ø SIZE OF HOMERUN CKT. TOTAL WATTS AMPERE NO. Ø SIZE OF HOMERUN CKT. TOTAL WATTS AMPERE NO. Ø SIZE OF HOMERUN
VOLTS DESCRIPTION AT VOLTS DESCRIPTION AT VOLTS DESCRIPTION AT
NO. NO. LOAD WIRE IN CONDUIT NO. NO. LOAD WIRE IN CONDUIT NO. NO. LOAD WIRE IN CONDUIT
1 230 LIGHTING 4 400 1.74 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE 1 230 LIGHTING 10 1000 4.35 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE 1 230 LIGHTING 10 1000 4.35 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
2 230 LIGHTING 14 1400 6.09 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE 2 230 CONVENIENCE OUTLET 6 1200 5.22 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE 2 230 CONVENIENCE OUTLET 6 1200 5.22 20 AT, 2P 2-3.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
3 230 SPARE 3 230 RANGE 1 3500 15.23 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE 3 230 RANGE 1 3500 15.23 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
4 230 SPARE 4 230 REFRIGERATOR 1 1200 5.22 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE 4 230 REFRIGERATOR 1 1200 5.22 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
TOTAL 1,800 7.83 5 230 ACU 1 932.5 4.06 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE 5 230 ACU 1 932.5 4.06 30 AT, 2P 2-5.5mm SQ. THHN, 1-2.0mm THHN in 20mm Ø CONDUIT PIPE
Computation: DEMAND FACTOR APPLICATION : 80%*1,800=1,440 WATTS 6 230 SPARE 6 230 SPARE
TOTAL CONNECTION LOAD + 25% OF THE LARGEST MOTOR = 1,790 WATTS 7 230 SPARE 7 230 SPARE
8 230 SPARE 8 230 SPARE
IT = 1,790 WATTS/230V USE : 2P 50A FOR CIRCUIT BREAKER,
IT = 7.78 AMPS TOTAL 7,832.5 34.08 TOTAL 7,832.5 34.08
2-8.00mm SQ. THW, 1-3.5mm TW in 40mm Ø RSC
Computation: DEMAND FACTOR APPLICATION : 80%*7,832.5=6,266 WATTS Computation: DEMAND FACTOR APPLICATION : 80%*7,832.5=6,266 WATTS
PROTECTION: USE 100AT/100AF, 2P 230 V, 60Hz, 10A
TOTAL CONNECTION LOAD + 25% OF THE LARGEST MOTOR = 7,141 WATTS TOTAL CONNECTION LOAD + 25% OF THE LARGEST MOTOR = 7,141 WATTS
ACB IN NEMA ENCLOSURE
IT = 7,141 WATTS/230V USE : 2P 50A FOR CIRCUIT BREAKER, IT = 7,141 WATTS/230V USE : 2P 50A FOR CIRCUIT BREAKER,
IT = 31.05 AMPS IT = 31.05 AMPS
2-8.00mm SQ. THW, 1-3.5mm TW in 40mm Ø RSC 2-8.00mm SQ. THW, 1-3.5mm TW in 40mm Ø RSC
PROTECTION: USE 100AT/100AF, 2P 230 V, 60Hz, 10A PROTECTION: USE 100AT/100AF, 2P 230 V, 60Hz, 10A
ACB IN NEMA ENCLOSURE ACB IN NEMA ENCLOSURE

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: POWER LAYOUT PLAN


E
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
ELECTRICAL ENGINEER CHECKED BY: ELECTRICAL LOAD COMPUTATIONS
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR

2 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)


lOMoARcPSD|41112317

SERVICE ENT. SERVICE ENT.


2 WIRE 220V, 2 WIRE 220V,
SERVICE 60Hz M 60Hz M
ENTRANCE USE: 2-38.0mm 2 USE: 2-38.0mm2
USE : USE : 2 - 38mm2 THHN WIRE THHN & 1-8.0mm 2 THHN & 1-8.0mm 2
1 - 8.0 MM2 TWN WIRE IN 40MMØ RSC IN 40mm DIA. RSC IN 40mm DIA. RSC
50 AT-MAIN 50 AT-MAIN
PB
1 20 AT 20 AT 20 AT 20 AT
LO CO LO CO
1 2 1 2
KWHM 160 AT, 2P 230 VAC 1 Ø 30 AT 30 AT 30 AT 30 AT
ACB IN NEMA ENCLOSURE RANGE REF RANGE REF
3 4 3 4
30 AT SPARE 30 AT SPARE
PB-1 PB-2 PB-3 PB-4 PB-5
ELECTRIC METER ACU ACU
5 6 5 6
SPARE SPARE SPARE SPARE
7 8 7 8
NGL
FFL.
ELECTRIC POLE GROUND GROUND
EMBEDDED IN CONCRETE
TO PANEL BOARD

SERVICE ENT. SERVICE ENT.


2 WIRE 220V, 2 WIRE 220V,
60Hz M 60Hz M
USE: 2-38.0mm2 USE: 2-38.0mm 2
SERVICE ENT. THHN & 1-8.0mm2 THHN & 1-8.0mm 2
2 WIRE 220V, IN 40mm DIA. RSC IN 40mm DIA. RSC
60Hz M
USE: 2-38.0mm2 50 AT-MAIN 50 AT-MAIN
THHN & 1-8.0mm 2 20 AT 20 AT 20 AT 20 AT
IN 40mm DIA. RSC LO CO LO CO
1 2 1 2
50 AT-MAIN 30 AT 30 AT 30 AT 30 AT
RANGE REF RANGE REF
3 4 3 4
20 AT 20 AT 30 AT SPARE 30 AT SPARE
LO LO ACU ACU
1 2 5 6 5 6
SPARE SPARE SPARE SPARE SPARE SPARE
3 4 7 8 7 8

GROUND GROUND GROUND

PROJECT TITLE: CAD BY: NOTE: SHEET CONTENTS SHEET NO.

DRAWN BY: RISER DIAGRAM


E
THESE DRAWING AS INSTRUMENTS
OF SERVICE. ARE THE PROPERTY
PROPOSED 2-STOREY WITH ROOFDECK AND DOCUMENTS OF THE
DESIGNER. IT SHALL BE UNLAWFUL
ELECTRICAL ENGINEER CHECKED BY: SINGLE LINE DIAGRAM
RESIDENTIAL BUILDING MR. JOSE PALMARIO
FOR ANY PERSON WITHOUT THE
WRITTEN CONSENT OF
DESIGNER OR AUTHORS OF SAID
THE

REG. NO. TIN.NO. OWNER DATED: DOCUMENTS, TO DUPLICATE OR

3 3
COPY SAID DOCUMENTS

RA. 545 SEC. 25 (4)


PTR.NO. DATE: LOCATION: #87 FILIPINAS AVENUE, UPS V, BRGY. SAN ISIDRO, PARANAQUE CITY ADDRESS: FILE NO.

Downloaded by Jeamel Joseph Mendoza (jjgm.game@gmail.com)

You might also like