Professional Documents
Culture Documents
3" 3" 1'-1" 3" 2. ANY DISCREPANCY IN THE DRAWING SHOULD BE BROUGHT
2 (9"X16")
PB-3 2'-9"
(9"X16")
5.
COLUMN - 40MM & PLINTH BEAM -50MM.
LOAD HAS BEEN TAKEN FOR (G+1) FLOORS ONLY.
(9"X16")
PB-19
(9"X16")
6. MINIMUM DEVELOPMENT LENGTH FOR TOR STEEL SHALL
PB-23
(9"X16")
(5"X12")
PB-17
BE 50d, WHERE "d" IS DIA OF MAIN REINFORCEMENT. THE LAP
11'-3"
PB-4 7. THE MIX FOR ALL R.C.C. WORK SHALL BE M-20 (1:1.5:3).
4 (9"X16") (9"X16") 10. BUILDING IS DESIGNED FOR EARTHQUAKE LOAD OF ZONE III.
(9"X16")
PB-14
(9"X16")
PB-16
(9"X16")
(9"X16")
PB-22
PB-20
12'-6"
LEGEND :-
_ 10"/5" THK.BRICK WORK _
PB-8 _ CONCRETE
PL
THK
_
PLINTH LEVEL
THICKNESS
_
TYP TYPICAL
4'-8" Up
DRAWN:- PRIYANKA
ARCHITECT:- DENCITY ARCHITECTS.
PB-9 DESIGN:- LOPAMUDRA
5 (9"X16") PB-10
SR ENGINEERING
CIVIL & STRUCTURAL
APRO :- R.N MOHAPATRA
SIGNATURE:-
CONSULTANTS
PLOT N0-1272/1275,GAYATRI NAGAR,
(9"X16")
(9"X16")
PB-18
(9"X16")
PB-21
PHAKIRPADA (TYPE-C1) BUILDING
PB-13
DRAWING TITLE:-
6 PB-11
PB-12
PLINTH BEAM LAYOUT
1'
(9"X16")
DEALT BY: DRAWING NO:
(9"X16") SCALE
7 NTS
PTC1/STR/03