STRUCTURAL NOTE:-

AB C DE F GH 1. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


RELEVANT ARCHITECTURAL DRAWINGS.

3" 3" 1'-1" 3" 2. ANY DISCREPANCY IN THE DRAWING SHOULD BE BROUGHT

12'-8" 4'-4" 8'-5" TO THE KNOWLEDGE OF CONSULTANT BEFORE EXECUTION.

3. DRAWING IS NOT TO BE SCALED ONLY WRITTEN DIMENSION


SHOULD BE FOLLOWED .

1 3" PB-1 PB-2


4. CLEAR COVER TO MAIN REINFORCEMENT SHALL BE FOR

2 (9"X16")
PB-3 2'-9"
(9"X16")
5.
COLUMN - 40MM & PLINTH BEAM -50MM.
LOAD HAS BEEN TAKEN FOR (G+1) FLOORS ONLY.

(9"X16")
PB-19

(9"X16")
6. MINIMUM DEVELOPMENT LENGTH FOR TOR STEEL SHALL

PB-23
(9"X16")
(5"X12")

PB-17
BE 50d, WHERE "d" IS DIA OF MAIN REINFORCEMENT. THE LAP
11'-3"

(9"X16") SHALL BE STAGGERED AND AVOIDED AT THE POINT OF


PB-15

MAXIMUM BENDING MOMENT .

PB-4 7. THE MIX FOR ALL R.C.C. WORK SHALL BE M-20 (1:1.5:3).

(5"X12") 8. ALL THE REINFORCEMENT SHALL BE Fe-500.


PB-7
3 3" 3'-1" (9"X16")
PB-5 PB-6 9. THE DESIGN WIND SPEED HAS BEEN CONSIDERED AS 50/SEC .

4 (9"X16") (9"X16") 10. BUILDING IS DESIGNED FOR EARTHQUAKE LOAD OF ZONE III.
(9"X16")
PB-14

(9"X16")
PB-16

11. ALL DIMENSION & LEVEL ARE IN FEET-INCH.

(9"X16")
(9"X16")

PB-22
PB-20
12'-6"

LEGEND :-
_ 10"/5" THK.BRICK WORK _
PB-8 _ CONCRETE
PL
THK
_
PLINTH LEVEL
THICKNESS
_
TYP TYPICAL

(9"X16") 9'-4" _ SAND FILLING #


C/C
_
_
DIAMETER
CENTER TO CENTER
FFL _ FINISHED FLOOR LEVEL _
_ PB PLINTH BEAM
FGL FINISHED GROUND LEVEL

4'-8" Up
DRAWN:- PRIYANKA
ARCHITECT:- DENCITY ARCHITECTS.
PB-9 DESIGN:- LOPAMUDRA

5 (9"X16") PB-10
SR ENGINEERING
CIVIL & STRUCTURAL
APRO :- R.N MOHAPATRA
SIGNATURE:-
CONSULTANTS
PLOT N0-1272/1275,GAYATRI NAGAR,

(9"X16") BOMIKHAL, BBSR-10


ER. R.N.Mohapatra
PROJECT TITLE:-
11'-6"

(9"X16")

(9"X16")
PB-18
(9"X16")

PB-21
PHAKIRPADA (TYPE-C1) BUILDING
PB-13

DRAWING TITLE:-

6 PB-11
PB-12
PLINTH BEAM LAYOUT
1'

(9"X16")
DEALT BY: DRAWING NO:
(9"X16") SCALE

7 NTS
PTC1/STR/03

REVISION: DATE: 12.10.2021 REMARKS:

PLINTH BEAM LAYOUT 00