Compiled Questions:
1.As designed and applied to this project, the yards abutting the RROW are for___.
A. landscaping
B. driveways
C. off-RROW loading spaces
D. short-term off-street parking
2.The measurement of lot occupancy taken from ground level includes the ___.
A. Stair well
B. yards
C. courts
D. light wells
3.What is the maximum width, in meters, of the driveway if its for one way?
A. 8
B. 5
C. 10
D. 6
4.What will be the LEAST total area of the windows at the Engineering Department Office in square
meters?
A. 10% of total area
B. 15% of total area
C. 42& of total area
D. 5% of total area
5.What is the LEAST total area of the windows at the business center in square meters?
A. 16.80
B. 15.00
C. 29.60
D. 33.00
6.What is the LEAST width in meters, of the t & b/shower?
A. 0.90
B. 1.00
C. 2.00
D. 3.00
7.The most suitable and practical door for the workshop are ___.
A. Roll-up shutter
B. center-hung
C. Double-swing
D. center-pivot
8.What is the minimum width, in meters, of the sidewalk in each side of the RROW?
A. 1.66
B. 2.00
C. 3.00
D. 1.20
9.The most appropriate floor tiles to use for the open decks are ___.
A. glazed
B. non-skid
C. polished
D. vinyl
10.The most appropriate floor finish for the storage is ___.
A. Granite slab
B. Rubberized paint
C. Ceramic tiles
D. Engineered wood
11.The most appropriate floor finish for the workshop is ___.
A. plastered plain cement
B. Rubberized paint
C. engineered wood
D. paint
12.The most appropriate floor finish for the business center is/are ___.
A. vinyl
B. engineered wood
C. Latex Paint
D. ceramic tiles
13.The most appropriate floor finish for the office is ___.
A. Solid wood
B. rubberized
C. Plastered plain cement
D. vinyl
14.What is NOT a secondary color?
A. Orange
B. Purple
C. Green
D. Yellow
15.What is NOT a tertiary color?
A. Blue-green
B. Red-orange
C. Yellow-orange
D. Blue-red
16.Which is NOT a common shape of metal top rail?
A. Rectangle
B. Oval
C. Square
D. Round
17.What is the common name for a single pole, double throw switch?
A. 3-way switch
B. Two gang switch
C. Triple gang switch
D. 2-way switch
18.An automatically operated electrical switch, its basic function is to detect fault condition and interrupt
current flow is a ___.
A. Switch board
B. Circuit breaker
C. Switch line
D. Automatic switch
19. What is the lot dimension of the project?
A. 24m x 91m
B. 24m x 99m
C. 55m x 105m
D. 53m x 105m
20. What is the AMBF of the project base on the given data?
A. 1,960 sqm
B. 2,064 sqm
C. 1,820 sqm
D. 2,220 sqm
21. What is the USA of the project base on the given data?
A. 687 sqm
B. 720 sqm
C. 807 sqm
D. 960 sqm
22. What is the Total Gross Floor Area of the project base on its given data?
A. 2,064 sqm
B. 1,796 sqm
C. 2,484 sqm
D. 2,560 sqm
23. What is the Percentage of Site Occupancy of the project in relation with its lot?
A. 40%
B. 37%
C. 50%
D. 75%
24. Base on Rule VII & VIII of National Building Code, what is the designated FLAR for the project?
A. 2.5
B. 9.0
C. 1.2
D. 3.0
25. What is the declared zoning classification of the site?
A. SPE
B. G-1
C. GI
D. Division C
26. Given the project site orientation, from what direction shall the “Amihan” wind come from?
A. East
B. SouthWest
C. SouthEast
D. NorthEast
27. If the building of this compound is defined as rectangle, what will be the building dimension of the
project?
A. 24m x 91m
B. 55m x 105m
C. 48m x 99m
D. 20m x 91m
28. What is the Maximum Allowable Construction Area of the project base on the given data?
A. 4,758 sqm
B. 3,501 sqm
C. 2,064 sqm
D. 4,760 sqm
29. What is the range of the number of tiles to be used in the Engineering Department office using 600mm
x 1200mm ceiling tiles?
A. 235 pcs
B. 58 pcs
C. 233 pcs
D. 250 pcs
30. What is the area/room aligned in ground floor with the Engineering department office?
A. Storage 1
B. Lobby
C. Business Center
D. Storage 2
31. Given that the slab at second floor is 0.12 meters thick, how many kilograms of steel reinforcing bars
needed if it requires 15kgs of reinforcing bars per cubic meter of concrete? Exclude the area of stairwell
of 3m x 6m.
A. 6,300 kgs
B. 6,030 kgs
C. 723.6 kgs
D. 756 kgs
32. Given the site condition, what is the type of lot for the said project?
A. End Lot
B. Regular Lot
C. Corner Lot
D. Inside Lot
33. Which of the following is NOT a hardware item?
A. door stop
B. door casing
C. lockset
D. door closer
34. If the offices at 2nd floor are not to be air-conditioned, what shall be the minimum distance in meters
between the FFL and ceiling, as compliance under the NBCP?
A. 2.10
B. 2.40
C. 2.70
D. 3.00
35. Assuming that docking/delivery platform of the project is 450mm above NGL, and the tread width of
the stair is 300mm, what will be the Total Run of the stair?
A. 150mm
B. 600mm
C. 300mm
D. 450mm
36. What is the least dimension of a parking slot for the disabled?
A. 2.50m
B. 3.00m
C. 4.10m
D. 3.70m
37. Under the 2004 Revised IRR of PD 1096 or NBCP, what is the term interchangeably used for an
institutional zoning classification?
A. Gross Institutional
B. General Institutional
C. Generic Institutional
D. Governmental Institutional
38. In terms of construction material production, which of the following flooring materials is considered
to have the lowest carbon footprint?
A. Vigan tiles
B. Mariwasa tiles
C. High-pressure laminate flooring
D. Baguio stone
39. Which of the following is a good general lighting color (i.e. the shade of the emitted artificial light), for
the work areas in the workshop?
A. Warm white
B. Cool white
C. Daylight
D. Yellow
40. Base on Rule VII & VIII of National Building Code, what is the Allowable Maximum PSO of the project?
A. 50%
B. 60%
C. 70%
D. 80%
41. This design variable refers to the size, position and orientation of windows; window glass materials;
external and internal shading devices.
A. Building Fabric
B. Fenestration
C. Thermal Insulation
D. Surface-to-Volume Ratio
42. Assuming that the workshop will be covered with T&G flooring. Compute for the total number of board
foot to be used if the workshop (excluding the 60sq.m T&B/locker room) will use 1”x4”x4’ T&G flooring
with an effective width of 3.5”.
A. 9,200 bft
B. 9,400 bft
C. 8,700 bft
D. 8,390 bft
43. What is the Gross Floor Area of the ground floor base on project given data?
A. 1,796 sqm
B. 1,448 sqm
C. 348 sqm
D. 2,040 sqm
44. Based on the NBCP Section 811 of Rule VIII, what is the minimum requirement for air changes for an
office?
A. 0.29 cu.m.
B. 1.20 cu.m.
C. 0.85 cu.m.
D. none of the choices
45. Formula in getting for the GFA of the building?
A. GFA = TGFA + nonGFA
B. GFA = TLA x multiplier
C. GFA = TLA x FLAR
D. All of the above
46. Base on project given, what is not included in the GFA?
A. Engineering Department office
B. Business Center side deck
C. Locker room
D. Storage 2
47. As per PD 1096, what is the classification of buildings of masonry and wood construction with a one-
hour fire-resistivity throughout and exterior walls of incombustible fire-resistive construction?
A. Type I
B. Type II
C. Type III
D. Type IV
48. Ingress/Egress, traffic, landscaping, et. Al are basic Design considerations for this project which falls
under?
A. Human determinants
B. Accessibility
C. Man-made environment
D. Aesthetics