You are on page 1of 2

TROPICAL INNOVATION INVERTER TECHNICAL SPECIFICATIONS

CET Series
*Specifications, design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. Specifications
are based on the following conditions; Cooling: Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Pipe length : 5.0 m Voltage : 230 [V]. Piping can
be extended to above length for full efficiency with additional charge of gas as per installation manual. The noise level is the value when measured in an anechoic room.
Star Rating:
Model Number: ASGG18CETA-B ASGG24CETA-B ASGG30CETA-B ASGG36CETA-B
INSTALLATION CHECK POINTS
25m
55°C
Advanced Hyper Double Swing Wide Voltage Range Silicon Coated High Voltage
Tropical Product Design Automatic-3D Airflow 155V ~ 280V (18/24) PCB for Long Life Protection 700V (18/24) Coanda Airflow(30/36)

3 METRES
PIPING KIT
INCLUDED
PM 2.5 Filter Self Diagnosis Wireless LAN (Optional)

Full Inverter Technology for extreme savings at partial load


Over 80% Cooling Capacity even at 52oC Anti-Corrosion Copper Heat Exchanger
%
100
Wireless Remote
Savings

80

60

40 (ASGG18CETA-B) 1.65TR 0.38TR


20
(ASGG24CETA-B) 2.20TR 0.50TR
(ASGG30CETA-B) 2.75TR 0.87TR
0
18CETA 24CETA 30CETA 36CETA (ASGG36CETA-B) 3.00TR 1.05TR
35ºC 52ºC 46ºC
Evaporator Epoxy Resin Coating Blue Fin Condenser Max Capacity Min Capacity

Long Reach Airflow 18m 20m 25m Wired Remote for


ASGG30CETA-B Group Controller
ASGG18CETA-B ASGG24CETA-B
ASGG36CETA-B (Optional)
Air Circulation Air Circulation Air Circulation
Dual Suction 1400 m³/hour 1500 m³/hour 1630 m³/hour
Intake Design

# Information is subject to change without prior notice.


*Design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. Please refer page 82 for specific modelwise features. *1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
*2: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.

60 61

FG0041 Fujitsu General Catalogue 2023 V2 Pg60_61 AW_A4_12 01 24_partha


EFFICIENT & TROPICAL INVERTER TECHNICAL SPECIFICATIONS

ASGG12CGTB-B

ASGG18CGTB-B
ASGG24CGTB-B

CGT Series *Specifications, design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. Specifications
are based on the following conditions; Cooling: Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Pipe length : 5.0 m Voltage : 230 [V]. Piping can
be extended to above length for full efficiency with additional charge of gas as per installation manual. The noise level is the value when measured in an anechoic room.

Star Rating:
Model Number: ASGG12CGTB-B ASGG18CGTB-B ASGG24CGTB-B INSTALLATION CHECK POINTS

ASGG18CGTB-B
15m ASGG12CGTB-B ASGG24CGTB-B
55 C°

Advanced
Hyper Tropical Coanda Airflow Wide Voltage Range
5 Star Rating PM 2.5 Filter Self Diagnosis
Product Design (18/24) 155V ~ 280V

Double Swing
0.5°C Precision Energy Saving With Automatic-3D Airflow Silicon Coated High Voltage
Temperature Control Backlit Remote Human Sensor (18/24) PCB for Long Life Protection 700V

Powerful
High
3 METRES Wireless Remote
Med
PIPING KIT
POWERFUL INCLUDED
Low
Quiet
Wireless LAN (Optional)
5 Speed Fan Control Powerful Mode

Over 80% Cooling Capacity even at 49oC Full Inverter Technology for extreme savings at partial load
Anti-Corrosion Copper Heat Exchanger
100
Savings

80

60

40
(ASGG12CGTB-B) 1.10TR 0.25TR
Wired Remote for
20 35oC

49oC
(ASGG18CGTB-B) 1.65TR 0.38TR Group Controller
0 (ASGG24CGTB-B) 2.20TR 0.50TR
12CGTB 18CGTB 24CGTB Evaporator with Epoxy Resin Coating Blue Fin Condenser Max Capacity Min Capacity (Optional)

# Information is subject to change without prior notice.


*Design and features are subject to change without prior notice for further development. The above models conform to energy labelling as per BEE regulation. Please refer page 82 for specific modelwise features. *1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
*2: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.

62 63

FG0041 Fujitsu General Catalogue 2023 V2 Pg62_63 AW_A4_12 01 24_partha