You are on page 1of 2

LP SERIES-GENERAL PURPOSE

P-TITLE (12V2.9Ah)
LP12-2.9

CHARACTERISTICS
Item Specifications
Rated Voltage P-RV
12V
Nominal Capacity (25℃) C20,1.75V/cell P-2075
2.9Ah
Length P-LENGTH
79mm (3.11inches)
Width P-WIDTH
56mm (2.20inches)
Dimension
Container Height P-HEIGHT
99mm (3.90inches)
Total Height 105mm P-THEIGHT
(4.13inches)
Approx Weight P-GWEIGHT
1.10kg (2.43lbs)
Terminal P-TER
T1
Container Material ABS (UL94 HB or V-0 optional)
Short-circuit current P-SC
81.2A
Internal Resistance (25℃) P-IR
Approx 50 mΩ (Fully charged)
Discharge -15~50℃ (5~122°F)
Operating Temp. Range Charge -20~40℃ (-4~104°F)
Storage -15~40℃ (5~104°F)
Nominal Operating Temp. Range 25±3℃ (77±5°F)
Max.Charging Current (25℃) 0.3C
StandbyUse CycleUse
Charge voltage (25℃)
2.25-2.30V/cell 2.35-2.45V/cell
Temp.Coeffcient -3mV/cell/℃ -5mV/cell/℃
40℃ (104°F) 103%
Effect of temp. to Capacity 25℃ (77°F) 100%
0℃ (32°F) 86%

≤3% per month at 25°C (77°F).


LP series batteries may be stored up to
Self Discharge 6 months at 25°C (77°F) and then a
freshening charge is required.
For higher temperatures the time interval
will be shorter.

DISCHARGE TABLE
Constant Current Discharge (Amperes) at 25°C (77°F)
F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h
P-A85
1.85V/cell A855m
8.14 A8510m
5.26 A8515m
4.11 A8520m
3.44 A8530m
2.61 A8545m
1.96 A851
1.59 A8515
1.24 A852
0.938 A853
0.687 A854
0.565 A855
0.474 A856
0.410 A858
0.317 A8510
0.264 A8520
0.142
P-A80
1.80V/cell A805m
8.75 A8010m
5.58 A8015m
4.31 A8020m
3.58 A8030m
2.69 A8045m
2.01 A801
1.63 A8015
1.27 A802
0.955 A803
0.699 A804
0.573 A805
0.481 A806
0.416 A808
0.321 A8010
0.267 A8020
0.143
P-A75
1.75V/cell A755m
9.22 A7510m
5.80 A7515m
4.46 A7520m
3.68 A7530m
2.76 A7545m
2.06 A751
1.66 A7515
1.29 A752
0.973 A753
0.710 A754
0.581 A755
0.487 A756
0.421 A758
0.325 A7510
0.270 A7520
0.145
P-A70
1.70V/cell A705m
9.66 A7010m
6.04 A7015m
4.60 A7020m
3.79 A7030m
2.83 A7045m
2.10 A701
1.70 A7015
1.31 A702
0.987 A703
0.720 A704
0.589 A705
0.494 A706
0.426 A708
0.328 A7010
0.273 A7020
0.146
P-A67
1.67V/cell A675m
10.0 A6710m
6.21 A6715m
4.72 A6720m
3.86 A6730m
2.88 A6745m
2.14 A671
1.72 A6715
1.33 A672
1.00 A673
0.727 A674
0.595 A675
0.498 A676
0.430 A678
0.331 A6710
0.275 A6720
0.147
P-A60
1.60V/cell A605m
10.6 A6010m
6.47 A6015m
4.88 A6020m
3.98 A6030m
2.96 A6045m
2.19 A601
1.76 A6015
1.36 A602
1.02 A603
0.741 A604
0.605 A605
0.506 A606
0.436 A608
0.336 A6010
0.278 A6020
0.149

Constant Power Discharge (Watts/cell) at 25°C (77°F)

F.V/Time 5min 10min 15min 20min 30min 45min 1h 1.5h 2h 3h 4h 5h 6h 8h 10h 20h
P-B85
1.85V/cell B855m
15.4 B8510m
10.0 B8515m
7.87 B8520m
6.63 B8530m
5.05 B8545m
3.80 B851
3.10 B8515
2.42 B852
1.84 B853
1.35 B854
1.11 B855
0.936 B856
0.811 B858
0.628 B8510
0.524 B8520
0.284
P-B80
1.80V/cell B805m
16.4 B8010m
10.5 B8015m
8.21 B8020m
6.86 B8030m
5.18 B8045m
3.89 B801
3.16 B8015
2.47 B802
1.87 B803
1.37 B804
1.13 B805
0.948 B806
0.822 B808
0.637 B8010
0.531 B8020
0.287
P-B75
1.75V/cell B755m
17.1 B7510m
10.9 B7515m
8.43 B7520m
7.01 B7530m
5.29 B7545m
3.96 B751
3.22 B7515
2.51 B752
1.89 B753
1.39 B754
1.14 B755
0.959 B756
0.831 B758
0.643 B7510
0.536 B7520
0.290
P-B70
1.70V/cell B705m
17.7 B7010m
11.3 B7015m
8.66 B7020m
7.18 B7030m
5.40 B7045m
4.04 B701
3.26 B7015
2.54 B702
1.92 B703
1.41 B704
1.15 B705
0.971 B706
0.839 B708
0.649 B7010
0.541 B7020
0.292
P-B67
1.67V/cell B675m
18.2 B6710m
11.5 B6715m
8.84 B6720m
7.31 B6730m
5.48 B6745m
4.09 B671
3.31 B6715
2.57 B672
1.94 B673
1.42 B674
1.16 B675
0.978 B676
0.846 B678
0.654 B6710
0.544 B6720
0.295
P-B60
1.60V/cell B605m
18.9 B6010m
11.8 B6015m
9.08 B6020m
7.49 B6030m
5.60 B6045m
4.16 B601
3.37 B6015
2.61 B602
1.97 B603
1.44 B604
1.18 B605
0.991 B606
0.856 B608
0.663 B6010
0.551 B6020
0.298
LP SERIES-GENERAL PURPOSE
P-TITLE (12V2.9Ah)
LP12-2.9

APPLICATIONS GENERAL FEATURES STANDARDS

• All purpose • 5 years design life (25℃) • Compliance with IEC 60896 standards,
• Uninterruptable Power Supply (UPS) • Lead calcium alloy, sealed design, no EU Battery Directive
watering required
• Electric Power System (EPS)
• Puncture resistant micro-porous glass mat • UL,CE Approved
• Emergency backup power supply separators extend life
• Alarm and security system • Unique technology optimizes power capacity, • Manufactured in Leoch®IATF 16949,
• Communication power supply cell consistency, and long-term reliability ISO 45001, ISO 9001 and ISO 14001
certified production facilities
• DC power supply • Designed for a wide range of applications
• Auto control system

Discharge Characteristics Charging Characteristics


Charge Charging Charging
Temperature:25℃ Volume Current Voltage

(V/cell)
(%) (XCA) (V/cell) 0.15CA-2.35V/cell Temperature: 25℃
2.17

2.00 120 0.15 Charged Volume


2.45
Voltage(V/cell)

1.83 100 0.12


2.40
10HR 20HR Charge Voltage
1.67 3HR 80
0.09
0.25HR 0.5HR 1HR 2.30
1.50 60
0.06
40 2.00 After 50% Discharge
1.33
After 100% Discharge
0.03
20
1.83 Charging Current
1 2 4 6 10 20 40 60 2 3 5 10 20 30
0 0 0
Min H 0 2 4 6 8 10 12 14 16 18 20

Discharge Time
Charging Time (hours)

Effects of Temperature on Capacity Self Discharge Characteristics

120 120

100
100
Available capacity / %

0.05CA

80
80
0.2CA
Capacity (%)

60
60
10℃
30℃ 20℃
40 40℃
1CA 40
20
20

0
-20 10 0 10 20 30 40 50 (℃) 0 5 10 15 20 25
-4 14 32 50 68 86 104 122 (°F)

Battery temperature
Storage time (months)

Leoch International Technology Ltd. Leoch Batteries Pte Ltd Leoch Battery Corporation Leoch Europe S.A.
www.leoch.com www.leoch.sg www.leochamericas.com www.leoch.eu

Data above is recommended and the picture is only for battery effect display, Leoch reserve the final right of explanation.
© LEOCH. All rights reserved.Trademarks and logos are the property of LEOCH and its affiliates unless otherwise
noted.Subject to revisions without prior notice. E&OE. P-VERSION
Publication No.:LB-LP12-2.9-PD-EN-V2.0-20231228

You might also like