You are on page 1of 6

#1: Single-Phase Induction Machine Parameters

DC Test: R1m = 1.7 

Blocked Rotor Test: VBL = 60 V


IBL = 7.7 A
BL = 42

No-Load Test: Vnl = 220V


Inl = 7.5A
nl = 76
#2 1- IM Turns Ratio & Capacitor-Run Value

Blocked-Rotor Test for Auxiliary only:

R1a = 3.7 
VBL = 103 V
IBL = 7.7 A
BL = - 39

Capacitor-Run:

V = 220 V
I = 4.5 A
 = - 65
Im = 6.3 A
m = - 84
#3 Universal Motor

AC DC

Nm T Nm T

1200 0.12 1570 0.12

1500 0.05 1730 0.06

1670 0.02 2000 0.03


#4 Iduction Generator, E vs. Im & Capacitor Value

As a Motor:
Vph I pf N
235 1.82 0.25 2988
226 1.6 0.27 2986
220 1.47 0.29 2984
220 1.33 0.34 2980
180 1.18 0.39 2974

As a Generator:
N = 2000 rpm, Vph = 160 V
#5 Induction Generator Critical Values

C4 C5 C6

2150 rpm 2123 rpm 2090 rpm


280 V 316 V 338 V
1980 rpm 1953 rpm 1924 rpm
185 V 260 V 290 V
1864 rpm 1660 rpm 1537 rpm
0V 0V 0V
#6 Induction Generator Loading C/Cs

V I N
300 0 2216
R 260 0.22 2228
170 0.28 2266
300 0 2213
275 0.15 2178
260 0.3 2148
240 0.43 2128
RL
224 0.53 2118
200 0.61 2115
180 0.67 2121
170 0.71 2132