STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton

petergo,id I pmtes.blogspot.com
Project Rumah Tinggal No. Test S - 1
Location Palm Spring PIK 2 GL -
Tested by - GWL -5.00 m
Area of Cone 10 cm^2 Area of Mantle 100 cm^2 13 April 2023
Date of Test

Reading Local Total Local Total Total Friction (Tf) kg/cm


Depth Presure Gauge friction ratio qc (cone Resistance) friction ratio (fs/qc) (%)
Friction Friction Friction Consistensi
(m) 2) (fs/qc) (%)
x kgf y kgf (fs)kg/cm (Lf)Kg/cm (Tf)kg/cm 0 500 1000 1500 0 5 10 15
0 100 200 300
0.00 0 0 0

Depth (m)
-0.20

Depth (m)

Depth (m)
-0.40 10 15 0.50 10 10 5.00 Firm
-0.60 15 25 1.00 20 30 6.67 Firm
-0.80 24 30 0.60 12 42 2.50 Firm
-1.00 17 20 0.30 6 48 1.76 Firm -1 -1 -1
-1.20 10 13 0.30 6 54 3.00 Firm
-1.40 6 14 0.80 16 70 13.33 Soft
-1.60 7 15 0.80 16 86 11.43 Soft
-1.80 5 12 0.70 14 100 14.00 Soft
-2.00 10 20 1.00 20 120 10.00 Firm -2 -2 -2
-2.20 15 20 0.50 10 130 3.33 Firm
-2.40 20 25 0.50 10 140 2.50 Firm
-2.60 16 20 0.40 8 148 2.50 Firm
-2.80 15 25 1.00 20 168 6.67 Firm
-3.00 16 21 0.50 10 178 3.13 Firm -3 -3 -3
-3.20 24 30 0.60 12 190 2.50 Firm
-3.40 25 32 0.70 14 204 2.80 Firm
-3.60 10 15 0.50 10 214 5.00 Firm
-3.80 11 17 0.60 12 226 5.45 Firm
-4.00 11 21 1.00 20 246 9.09 Firm -4 -4 -4
-4.20 15 20 0.50 10 256 3.33 Firm
-4.40 25 30 0.50 10 266 2.00 Firm
-4.60 26 34 0.80 16 282 3.08 Firm
-4.80 30 35 0.50 10 292 1.67 Firm
-5.00 25 35 1.00 20 312 4.00 Firm -5 -5 -5
-5.20 24 30 0.60 12 324 2.50 Firm
-5.40 15 20 0.50 10 334 3.33 Firm
-5.60 20 25 0.50 10 344 2.50 Firm
-5.80 10 15 0.50 10 354 5.00 Firm
-6.00 15 25 1.00 20 374 6.67 Firm -6 -6 -6
-6.20 25 30 0.50 10 384 2.00 Firm
-6.40 25 35 1.00 20 404 4.00 Firm
-6.60 10 15 0.50 10 414 5.00 Firm
-6.80 11 17 0.60 12 426 5.45 Firm
-7.00 9 11 0.20 4 430 2.22 Soft -7 -7 -7
-7.20 6 9 0.30 6 436 5.00 Soft
-7.40 4 8 0.40 8 444 10.00 Very Soft
-7.60 6 10 0.40 8 452 6.67 Soft
-7.80 10 15 0.50 10 462 5.00 Firm
-8.00 10 20 1.00 20 482 10.00 Firm -8 -8 -8
-8.20 10 14 0.40 8 490 4.00 Firm
-8.40 15 19 0.40 8 498 2.67 Firm
-8.60 14 16 0.20 4 502 1.43 Firm
-8.80 15 20 0.50 10 512 3.33 Firm
-9.00 12 22 1.00 20 532 8.33 Firm -9 -9 -9
-9.20 28 32 0.40 8 540 1.43 Firm
-9.40 30 35 0.50 10 550 1.67 Firm
-9.60 20 35 1.50 30 580 7.50 Firm
-9.80 35 42 0.70 14 594 2.00 Stiff
-10.00 37 45 0.80 16 610 2.16 Stiff -10 -10 -10
-10.20 40 45 0.50 10 620 1.25 Stiff
-10.40 40 45 0.50 10 630 1.25 Stiff
-10.60 35 40 0.50 10 640 1.43 Stiff
-10.80 30 42 1.20 24 664 4.00 Firm
-11.00 25 35 1.00 20 684 4.00 Firm -11 -11 -11
-11.20 30 40 1.00 20 704 3.33 Firm
-11.40 25 30 0.50 10 714 2.00 Firm
-11.60 20 25 0.50 10 724 2.50 Firm
-11.80 27 32 0.50 10 734 1.85 Firm
-12.00 25 30 0.50 10 744 2.00 Firm -12 -12 -12
-12.20 20 25 0.50 10 754 2.50 Firm
-12.40 18 20 0.20 4 758 1.11 Firm
-12.60 15 20 0.50 10 768 3.33 Firm
-12.80 10 17 0.70 14 782 7.00 Firm
-13.00 12 18 0.60 12 794 5.00 Firm -13 -13 -13
-13.20 8 14 0.60 12 806 7.50 Soft
-13.40 10 15 0.50 10 816 5.00 Firm
-13.60 9 16 0.70 14 830 7.78 Soft
-13.80 17 20 0.30 6 836 1.76 Firm
-14.00 15 18 0.30 6 842 2.00 Firm -14 -14 -14
-14.20 10 15 0.50 10 852 5.00 Firm
-14.40 13 17 0.40 8 860 3.08 Firm
-14.60 10 12 0.20 4 864 2.00 Firm
-14.80 11 17 0.60 12 876 5.45 Firm
-15.00 9 12 0.30 6 882 3.33 Soft -15 -15 -15
-15.20 10 15 0.50 10 892 5.00 Firm
-15.40 15 19 0.40 8 900 2.67 Firm
-15.60 20 25 0.50 10 910 2.50 Firm
STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton
petergo,id I pmtes.blogspot.com
Project Rumah Tinggal No. Test S - 1
Location Palm Spring PIK 2 GL -
Tested by - GWL -5.00 m
Area of Cone 10 cm^2 Area of Mantle 100 cm^2 13 April 2023
Date of Test

Reading Local Total Local Total Total Friction (Tf) kg/cm


Depth Presure Gauge friction ratio qc (cone Resistance) friction ratio (fs/qc) (%)
Friction Friction Friction Consistensi
(m) 2) (fs/qc) (%)
x kgf y kgf (fs)kg/cm (Lf)Kg/cm (Tf)kg/cm 0 500 1000 1500 0 5 10 15
0 100 200 300
-15.80 25 30 0.50 10 920 2.00 Firm 0 0
-16.00 32 40 0.80 16 936 2.50 Firm -16 -16 -16
-16.20 40 42 0.20 4 940 0.50 Stiff
-16.40 45 48 0.30 6 946 0.67 Stiff
-16.60 35 40 0.50 10 956 1.43 Stiff
-16.80 40 45 0.50 10 966 1.25 Stiff
-17.00 45 50 0.50 10 976 1.11 Stiff -17 -17 -17
-17.20 50 55 0.50 10 986 1.00 Stiff
-17.40 57 65 0.80 16 1002 1.40 Stiff
-17.60 60 65 0.50 10 1012 0.83 Very Stiff
-17.80 60 75 1.50 30 1042 2.50 Very Stiff
-18.00 75 85 1.00 20 1062 1.33 Very Stiff -18 -18 -18
-18.20 100 105 0.50 10 1072 0.50 Very Stiff
-18.40 110 115 0.50 10 1082 0.45 Very Stiff
-18.60 125 130 0.50 10 1092 0.40 Hard
-18.80 185 200 1.50 30 1122 0.81 Hard
-19.00 210 220 1.00 20 1142 0.48 Hard -19 -19 -19
-19.20 230 250 2.00 40 1182 0.87 Hard
-19.40 250 251 0.10 2 1184 Hard
STATIC CONE PENETRATION TEST (ASTM D-3441) Capacity 2,50 Ton
petergo,id I pmtes.blogspot.com
Project Rumah Tinggal No. Test S-1
Location Palm Spring PIK 2 GL -
Tested by 0 - GWL - 5.00 m
Area of Cone 10 cm^2 Area of Mantle 100 cm^2 0 Date of Test 13 April 2023

qc (cone Resistance) Total Friction (Tf) kg/cm friction ratio (fs/qc) (%)
0 50 100 150 200 250 300 0 500 1000 1500 0 5 10 15
0.0 0.0 0.0

-1.0 -1.0 -1.0

-2.0 -2.0 -2.0

-3.0 -3.0 -3.0

-4.0 -4.0 -4.0

-5.0 -5.0 -5.0

-6.0 -6.0 -6.0

-7.0 -7.0 -7.0

-8.0 -8.0 -8.0

-9.0 -9.0 -9.0

-10.0 -10.0 -10.0

-11.0 -11.0 -11.0

Depth (m)
Depth (m)
Depth (m)

-12.0 -12.0 -12.0

-13.0 -13.0 -13.0

-14.0 -14.0 -14.0

-15.0 -15.0 -15.0

-16.0 -16.0 -16.0

-17.0 -17.0 -17.0

-18.0 -18.0 -18.0

-19.0 -19.0 -19.0

-20.0 -20.0 -20.0

-21.0 -21.0 -21.0

-22.0 -22.0 -22.0

-23.0 -23.0 -23.0

-24.0 -24.0 -24.0

-25.0 -25.0 -25.0

-26.0 -26.0 -26.0

-27.0 -27.0 -27.0

-28.0 -28.0 -28.0

-29.0 -29.0 -29.0

-30.0 -30.0 -30.0