Error Type Classification Description

LOG A Error/event is only logged.

TERMINATION B Error/event is logged as specified above and filling is


terminated.

SEMI-FATAL C Error/event is logged as specified above, filling is terminated


and current dispenser side is closed. Error cleared on entry to
maintenance mode or Reset.

SEMI-FATAL, NOT D Error/event is logged as specified above, filling is terminated


CLEARD ON MM EXIT or and current dispenser side is closed. Error only cleared on
RESET specific command or action. Error state is remembered between
resets.

FULLY-FATAL E Error/event is logged as specified above, filling is terminated


and both dispenser sides are closed.

CATASTROPHIC F Error/event is logged as specified above, filling is terminated


and both dispenser sides are closed, power cycle must be done

INDICATION G Error/event is not logged, but certain message on display gives


information about error

DISABLED H Error is not logged, no action

COUNT I Error is not logged, error counter is increased.

BOOT LOCK J Pump remain in Bootloader mode. Dispenser application will not
be started until error has been corrected.

Only method of communication with iGEM is by using remote


control or iSense.

POS com is NOT running and no fillings are possible.


No. Error/Event Description Classification

IE IFSF U
C S

0 Not used H H H

Error codes logged by Bootloader.

1 BOOTLOADER DETECTED Warranty is void. Board must be replaced. J J J


TAMPER

2 BOOTLOADER DETECTED Require download of new Dispenser App J J J


DISPENSER APP FW CRC ERROR FW

3 BOOTLOADER DETECTED Require confirmation of at least Engineer J J J


RTC and/or VBAT ERROR level in O995.

4 BOOTLOADER DETECTED Require confirmation of at least Engineer J J J


Damaged Logs E002, E040, E041 level in O995
and/or E505

5 BOOTLOADER DETECTED Require confirmation of at least Engineer J J J


I/O BOARD TAMPER level in O995

6 – 15 Not used

Error codes logged by Dispenser Application.

16 EEPROM NOT INITIALIZED A A A

17 RTC BATTERY FAILURE A A A

18 RTC VALUE TOO LOW A A A

19 FAILED TEST INTERNAL SRAM F C F

20 FAILED TEST EXTERNAL SRAM F C F

21 Reserved

22 INTERNAL LR ROM CRC ERROR F C F

23 INTERNAL NON-LR ROM CRC ERROR F C F

24 EXTERNAL LR ROM CRF ERROR F C F

25 EXTERNAL NON-LR ROM CRC ERROR F C F


No. Error/Event Description Classification

IE IFSF U
C S

26 Reserved

27 Reserved

28 COMPLETE ROM SHA-256 ERROR F C F

29 BOOT RESET LOG DAMAGED E A A

30 Reserved

31 BAD POWER A A A

32 VBAT ERROR A A A

33 DFLASH SECURITY KEYS CORRUPT CRC E A B

34 TAMPER SENSORS TRIGGERED A A A

35 Reserved

36 Reserved

37 SECURITY CRITICAL EVENT LOG E A B


DAMAGED

38 DATA UPLOAD LOG DAMAGED E A B

39 FW UPLOAD LOG DAMAGED E A B

40 RESET INFO LOG DAMAGED A A B

41 BOOTLOADER ACCESS SETTING B A B


DAMAGED

42 FW DOWNLOAD LOG DAMAGED E A B

43 HARD FAULT LOG DAMAGED A A B

44 – 49 Not used
No. Error/Event Description Classification

IE IFSF U
C S

50 LOG NOZ TOTALIZERS DAMAGED EE Device code = 0 then totalizers have been E A B
cleared, RAM copy also damaged.

Device code = 1 then totalizers have been


restored from RAM copy at initialisation.

Device code = 2 then totalizers have been


restored from RAM copy after
maintenance change.

51 METER TOALIZERS DAMAGED EE E A B

52 WSA ACCESS LOG DAMAGED EE E A B

53 ENGINEER ACCESS LOG DAMAGED EE E A B

54 TRANSACTION LOG DAMAGED EE E A B

55 NRST FILLING COUNTERS DAMAGED E A B


EE

56 – 59 Not used

60 IDPROM DATA DAMAGED DF B A B

61 PUMP INFO DATA DAMAGED DF B A B

62 METER CALIBRATION LOG DAMAGED E A B


DF

63 Not used

64 DEVICE FW CHANGE LOG DAMAGED E A B


DF

65 DEVICE REPLACEMENT LOG DAMAGED E A B


DF

66 LR CONFIGURATIONS DAMAGED DF E C B

67 DFLASH ERASE/WRITE ERROR DF B A B

68 – 69 Not used

70 NON LR CONFIGURATIONS DAMAGED E C B


No. Error/Event Description Classification

IE IFSF U
C S

71 NV UNIT PRICE DATA DAMAGED E C B

72 NV IFSF DATA DAMAGED E A B

73 – 79 Not used

80 RST FILLING COUNTERS DAMAGED E B B

81 Reserved

82 NV ERROR TOALS DAMAGED E B B

83 NV ERROR TOTALIZERS DAMAGED E B B

84 NV LOG NOZ TOTALS DAMAGED E B B

85 NV METER TOTALS DAMAGED E B B

86 NV EMT REMAINDERS DAMAGED E B B

87 NV LAST SALE BACKUP DAMAGED E A B

88 NV FACTORY DEFAULT DATA DAMAGE E A B

89 – 98 Not used

99 NV ERROR LOG DAMAGED Perform power cycle to clear the error C A B

100 NV VOL UNIT CHANGE LOG DAMAGED E A B

101 NV VOL BLEND RATIO CHANGE LOG E A B


DAMAGED

102 NV ATC CHANGE LOG DAMAGED E A B

103 NV VRM CHANGE LOG DAMAGED E A B

104 NV UNIT PRICE CHANGE LOG E A B


DAMAGED

105 NV PARAMETER CHANGE LOG E A B


DAMAGED

106 NV METER CHANGE LOG DAMAGED E A B


No. Error/Event Description Classification

IE IFSF U
C S

107 NV DISPLAY CHANGE LOG DAMAGED E A B

108 NV EMT CHANGE LOG DAMAGED E A B

109 NV I/O-BOARD CHANGE LOG E A B


DAMAGED

110 NV IX CHANGE LOG DAMAGED E A B

111 NV POS CHANGE LOG DAMAGED E A B

112 NV PROTOCOL CONVERTER CHANGE E A B


LOG DAMAGED

113 NV RECEIPT TEXT CONFIG DAMAGED E A B

114 NV OPERATOR ACCESS LOG DAMAGED E A B

115 NV MANAGER ACCESS LOG DAMAGED E A B

116 NV WIP CALIBRATION HIST LOG E A B


DAMAGED

117 NV WIP SERIAL DATA DAMAGED E A B

118 NV ATC IDPROM DATA DAMAGED E A B

119 NV CORIOLIS ZPA EVENT LOG E A B


DAMAGED

120 NV CORIOLIS STATISTIC DATA E A B


DAMAGED

121 NV CORIOLIS PARAMETER CHANGE E A B


EVENT LOG DAMAGED

122 NV PULSE OUTPUT CHANGE EVENT E A B


LOG DAMAGED

123 NV PRESSURIZE CHANGE EVENT LOG E A B


DAMAGED

124 NV ATC EVALUATION MODE CHANGE E A B


EVENT LOG DAMAGED
No. Error/Event Description Classification

IE IFSF U
C S

125 NV VRM PARAMETER CHANGE EVENT E A B


LOG DAMAGED

126 NV MAINTENANCE MODE OPERATION E A B


EVENT LOG DAMAGED

127 PPM CALIBRATION HISTORY LOG E A B


DAMAGED

128 TCP/IP BRIDGE IDPROM COPY A A B


CORRUPT

129 – 139 Not used

140 NV FLOW RATE LOG DAMAGED E A B

141 – 149 Not used

150 NV XWIP CALIBRATION TABLE E A B


DAMAGED

151 NV WAYNE VR CALIBRATION DATA E B B


DAMAGED

152 NV VAPOUR GATE CALIBRATION DATA E B B


DAMAGED

153 NV VOLTAGE STATISTICS DAMAGED A A A

154 NV INMETRO SW DOWNLOAD LOG


DAMAGED

155 EXTERNAL FLASH INMETRO SW


DOWNLOAD LOG DAMAGED

156 NV INMETRO LR CHANGE LOG


DAMAGED

157 EXTERNAL FLASH INMETRO LR


CHANGE LOG DAMAGED

158 NV INMETRO MAINTENANCE LOG


DAMAGED
No. Error/Event Description Classification

IE IFSF U
C S

159 EXTERNAL FLASH INMETRO


MAINTENANCE LOG DAMAGED

160 – 189 Not used

190 HW / SW MISSMATCH E E E

190 – 197 Not used

198 NOT ENOUGH MEMORY iGEM was not able to save all parameters F F F
in non-volatile storage. Set O704.004 = 1
to clear the error.

Device code:

1 = LR Configuration in D-FLASH
2 = LR Configuration in SRAM
3 = non-LR Configuration in SRAM

199 GENERIC CONFIG ERROR Device code: G G G

1 = Primary meter required


2 = LPG WIP on non-LPG product
3 = ATC on mass-meter
4 = incorrect calibration method on mass-
meter
5 = n/a
6 = unknown meter type
7 = same meter mapped to two sides
8 = VR enabled on side C or D (not
supported)
9 = Proportional valve FTM PWM conflict
10 = Blend ratio
11 = I/O-board feature set miss match

200 SALES DISPLAY IDPROM CRC ERROR C C C

201 UP DISPLAY IDPROM CRC ERROR C C C

202 PRESET DISPLAY IDPROM CRC ERROR C C C

203 POS INTERFACE IDPROM CRC ERROR C C C

204 I/O BOARD IDPROM CRC ERROR C C C


No. Error/Event Description Classification

IE IFSF U
C S

205 EXPANSION BOARD IDPROM CRC A A A


ERROR

206 INTERFACE BOARD IDPROM CRC A A A


ERROR

207 – 209 Not used

210 DAUP COM ERROR Communication lost with a DAUP device B B B


→ Protocol re-start.

Device codes:
1 – 4: Primary sales display (A – D)
5 – 8: Secondary sales display (A – D)
9 – 12: Ternary sales display (A – D)
13 – 16: Primary UPD (A – D)
17 – 20: Secondary UPD (A – D)
21 – 24: Ternary UPD (A – D)
25 – 28: Primary Preset display (A – D)
29 – 32: Secondary Preset display (A – D)
33 – 36: Ternary Preset display (A – D)
37 – 38: Extended UPD (A – B)

211 DAUP MAX NOF NAKs 3 NAKs received → Protocol re-start. B B B

212 DAUP WRONG SEQ # Not allowed sequence # received → A A A


Protocol re-start.

213 DAUP CRC ERROR → Data is ignored A A A

214 DAUP DEVICE ERROR MINOR Lnoz code indicate status code from B B B
device:
3: Display module error
9: Too many chars received
10: ASCII format error
11: BCD format error
No. Error/Event Description Classification

IE IFSF U
C S

215 DAUP DEVICE ERROR MAJOR Lnoz code indicate status code from B B B
device:
1: RAM error
2: ROM error
4: Device has Reset
7: Device IDPROM CRC error
8: WDOG reset in device

216 DAUP DEVICE SERIAL NO MISSMATCH Daup device has been replaced. If the D B B
change is intentional, confirm the
replacement in O701.002 = 11.

This error can also be logged if address


switch of the display is set incorrect. Make
sure address is set correct for the side and
Pri/Sec/Ter functionality.

217 DAUP ENCRYPTION ERROR Data expected to be encrypted was sent C C C


un-encrypted.

Shut off power to the pump for 1 minute


then power on again.

218 Not used

219 CAN-BUS ERROR Device code: I I A

0 = Bus is off
1 = stuff error
2 = form error
3 = ACK error
4 = Bit1 error
5 = Bit0 error
6 = CRC error
7 = Large Msg Tx Timeout
8 = Large Msg Rx Timeout

220 ATC COM ERROR B B B

221 ATC PROBE SHORTED OR OPEN B B B

222 ATC PROBE DAMAGED B B B


No. Error/Event Description Classification

IE IFSF U
C S

223 ATC FUEL TYPE MISSMATCH Fuel/Density miss match detected by FT- B E B
board

224 ATC CONFIGURATION ERROR Miss match in FUEL densities vs product D D D


types or different product types assigned
to same probe detected by iGEM.

225 ATC FT-BOARD S/N MISS MATCH FT-board has been replaced. C C C

To be able to perform fillings, confirm the


replacement in O701.004 = 1.

226 ATC VCF OUT OF LIMIT FT-board reported VCF that was out of C C C
limit

227 ATC W&M SWITCH OUT WHEN NOT If attempting to start filling with ATC E E E
SUPPOSED TO W&M switch out or switch is out on exit
and save or reset.

Return switch then perform reset or


enter+exit maint mode again.

228- 229 Not used

230 VR NOT CALIBRATED The VR has no calibration A A A

231 VR VALVE CURRENT LOW No VR valve connected A A A

232 VR VALVE CURRENT HIGH VR valve is shorted A A A

233 VR MOTOR CONTACTOR ERROR No VR motor connected A A A

234 VR EXTERNAL BÜRKERT ERROR External error signal detected and A A A


reported by Bürkert

235 VR BÜRKERT BOARD ERROR No VR connected or board is damaged A A A

236 VRM 10 CONSECUTIVE BAD FILLINGS Shut-down Timer start to decrement… A A A


No. Error/Event Description Classification

IE IFSF U
C S

237 VRM SHUT-DOWN TIME HAS ELAPSED The 72 – 168 hours (depending on B B B
country) has elapsed since error was
triggered. No further fillings on VR nozzles
are possible.

238 VRM METER SIGNAL ERROR The pump has detected error with the B B B
VRM system.

Device code indicate type of error:


1 = Low frequency error on sensor signal
3 = High frequency error on sensor signal
2 = Ghost pulses in IDLE

Auto recovery when error is detected to


have disappeared for >20 seconds.

239 VRM ERROR HAS BEEN RESTORED VR nozzles are operational. A A A

240 VRM MAX NOF SELF-TEST ERRORS Possible blockage on the suction side A A A
(nozzle or hose).

241 VRM PROTOCOL OFFLINE ERROR No poll from Vapour Gate diagnostic A B B
protocol Master.

242 – 249 Not used

250 I/O-BOARD REPLACED Serial No miss-match. If intended, confirm E E E


by O701.000 = 1.

Device code = 0 → nozzle interface


replaced
Device code = 1 → I/O-board replaced

251 TCP/IP BRIDGE REPLACED Serial No Miss-match. E E B

If intended, confirm by O701.008 = 1.

252 – 259 Not used

260 PRINTER COM ERROR C B A

261 PRINTER PAPER JAM C B A

262 PRINTER PAPER LOW C B A


No. Error/Event Description Classification

IE IFSF U
C S

263 PRINTER OUT OF PAPER C B A

264 PRINTER PAPER DOOR OPEN C B A

265 PRINTER HEAD OPEN C B A

266 PRINTER PAPER CUTTER ERROR C B A

267 PRINTER HEAD TEMP TOO HIGH C B A

268 – 269 Not used

270 POS COM LOST C C B

271 POS COM OUT OF TX BUFFERS A A H

272 POS COM CRC ERROR A A B

273 POS NO PRODUCTS WHEN IFSF C C C

274 – 279 Not used

280 SPI2 COM ERROR Communication error with TCP/IP bridge I I I

Only logged to A-side (E101)

281 SPI2 NO BUFFER No Rx or Tx buffer available for com I I I


to/from TCP/IP bridge.

Only logged to A-side (E101)

283 INMETRO BLUETOOTH DEVICE Confirm new BTD with O701.011 D D D


REPLACED

284 NV BLUETOOTH DEVICE IDPROM A A A


DAMAGED

285 INMETRO LOST BLUETOOTH D D D


COMMUNICATION

286 INMETRO BLUETOOTH D D D


CONFIGURATION ISSUE

287 – 289
No. Error/Event Description Classification

IE IFSF U
C S

290 ACCELEROMETER INITIALIZATION I I I


FAILURE

291 ATEX ADDITIVE GENERAL ERROR Device code: B B B

1 = Mode switch mismatch Error


2 = Configuration mismatch Error
3 = Board RAM Error
4 = Board ROM Error
5 = Board WDOG Error
6 = UART Error (additive tank gauge)
7 = Filling in Normal mode attempted with
AAB Switch set
in Service Mode

292 ATEX ADDITIVE NODE ERROR Device code: B B B

1 – 4 = Node # PPM ratio out of limit


Error
11 – 14 = Node # valve feedback Error
(offset by 10)
21 – 24 = Node # Motor feedback Error
(offset by 20)
31 – 34 = Node # Leakage error ≥ 5 ml
since last filling
(offset by 30)
41 – 44 = Node# consecutive PPM ratio
out of limit
(offset by 40). Will disable
Additive products.

293 ATEX ADDITIVE TANK LEVEL LOW Device code: A A A

1 = Tank 1 level Low


2 = Tank 1 level Middle
3 = Tank 1 level Full

4 = Tank 2 level Low


5 = Tank 2 level Middle
6 = Tank 2 level Full
No. Error/Event Description Classification

IE IFSF U
C S

294 ATEX ADDITIVE TANK LEVEL EMPTY Will disable Additive products. B B B

Device code:

1 = Tank 1
2 = Tank 2

295 ATEX Additive Hatch Open Will disable Additive products. B B B

Device code:

1 = Tank 1
2 = Tank 2

296 ATEX ADDITIVE BOARD REPLACED Serial No miss-match. D D D

If intended, confirm by 0701.010 = 1

297 ATEX ADDITIVE COM ERROR B B B

298 ATEX ADDITIVE NV IDPROM DB BAD A A A

299 Not used

300 FAILED TEST LR SALE SRAM B B B

301 UNIT PRICE IS TOO LOW B B B

302 NEED PRESET Pump configured to require local preset B B B


entry before start of filling but no preset
has been entered.

303 – 309 Not used

310 DELIVERY LIMIT OVERRUN Pump could not stop on target delivery B B B
limit.

Check that valve type is correct in Fs23


Check setting of Fs25 – Fs28

311 HOSE LEAK TEST LIMIT EXCEEDED Check for leaking nozzle or hose. Could B B B

312 HOSE LEAK TEST MAX CONSECUTIVE Check for leaking nozzle or hose C C C
No. Error/Event Description Classification

IE IFSF U
C S

313 BLEND ERROR Check that correct valve type mounted B B B


and that fluid on all feedstocks

314 PRESSURE LOST ON A HYDRAULIC Check that fluid on all feedstocks B B B

315 LEAKAGE BEFORE VALVE OPEN Check for leaking valve B B B

316 – 319 Not used

320 MAX COAST TIMER REACHED Pump could not stop the flow within X E E E
seconds.

F022.005

321 MAX AUTHORIZED TIME REACHED Pump is only allowed to stay in state A A A
AUTHORIZED with nozzle in for X minutes
after which it terminate the release.

F022.003

322 MAX TIME WITH NO FLOW DETECTED No flow was detected for X seconds. B B B

F022.006.

323 MAX CONSECUTIVE NO FLOW ERRORS F014.000 C B B

324 MAX TIME WITH FLOW LOST REACHED No flow was detected for X seconds. B B B

F022.007.

325 MAX CONSECUTIVE NO FLOW ERRORS F014.001 C B B

326 UN-FINISHED FILLING B B B

327 MAX CONSECUTIVE UN-FINISHED C B B


FILLINGS

328 HYDRO FILTER CLOGGED C C A

329 LPG EXESSIVE FLOW RATE B B B

330 MAX NOF FILLING NOT REACHING A A A


TARGET FLOW RATE
No. Error/Event Description Classification

IE IFSF U
C S

331 FILLING TERMINATED BY STOP B B B


BUTTON

332 MOTOR FEEDBACK ERROR B B B

333 PUMP IN UPS MODE F F A

334 TANK LEVEL LOW C C A

335 ZERO FLOW DETECTED I I I

336 – 349 Not used

350 DISPLAY UPD HW/SW MISS MATCH Mappings didn’t match UPD’s available. D D D

Se parameter F012.007 for different


settings depending on if ATEX pump UL
pump or UL with single or double row UPD
modules.

351 DISPLAY SALES HW/SW MISS MATCH “ D D D

352 DISPLAY PRESET HW/SW MISS MATCH “ D D D

353 DISPLAY UPD HW MISS MATCH Different HW between Primary, Secondary D D D


and Ternary display units.

They must be identical.

354 DISPLAY SALES HW MISS MATCH “ D D D

355 DISPLAY PRESET HW MISS MATCH “ D D D

356 Not used B B B

357 DISPLAY NO SALES VOLUME DISPLAY Sales display most likely didn’t respond B B B
with IDPROM info.

358 DISPLAY NO UPD DISPLAY Filling started on logical nozzle with an B B B


UPD assigned to it and the physical UPD
has zero digits.

359 INVALID INMETRO DISPLAY

360 – 399 Not used


No. Error/Event Description Classification

IE IFSF U
C S

400 METER REPLACED Serial No miss-match. C C B

If intended, confirm by 0701.001 = 1

Note! Meter calibration event log will be


updated if the calibration constants differ
compared to the old meter/encoder.

401 METER CALIBRATION DATA DIFFERS Lnoz# indicate what data differed: C C C
FROM DATA STORED ON iGEM 1 = XWIP curve elements
2 = XWIP K-factor
3 = XWIP product type

See separate section Error! Reference


source not found. for handling based on if
iGEM or XWIP has been replaced.

402 ILLEGAL METER INCREMENT DURING Italian Job. Tamper detected. F F F


POWER-OFF
F031.001

403 PRODUCT TYPE DOESN’T MATCH Fs23.01n doesn’t match meter/pulser E E E


METER/PULSER TYPE type. E g LPG WIP or meter but not LPG
product type.

404 INVALID INMETRO METER

405 – 409 Not used

410 CORIOLIS METER DENSITY ERROR Only logged if in normal operating mode B B B
(not logged in any of the W&M modes)

411 CORIOLIS METER IS NOT IN Coriolis meter is not in Custody Transfer B B B


PROTECTED MODE Mode but pump is in normal filling mode
or Std W&M mode.

412 CORIOLIS METER CONFIGURATION Coriolis settings of iGEM doesn’t match B B B


ERROR the ones stored in the meter.

Meter must not be in Custody Transfer


Mode in order to be able to send the
settings of iGEM to the coriois meter.

413 – 419 Not used


No. Error/Event Description Classification

IE IFSF U
C S

420 “IN-TRANSACTION” METER: F030.1MM (MM = Meter no) B C B


MAX BACK/ERROR PULSE LIMIT
REACHED

421 “IN-TRANSACTION” METER: Probably filled more than allowed with B B B


MAX BACK/ERROR PULSE LIMIT calibration magnets out while calibrating
REACHED WITH CALIBRATION or forgot to return calibratiomagnet.
MAGNETS OUT
Possibly wrong polarity of magnet if
previously not run replacement WIP.

422 – 424 Reserved for future “In-TRANSACTION”


METER errors not related to data
transmission

425 “IN-TRANSACTION” METER: Meter not responding to communication B C B


COMMUNICATION LOSS

426 “IN-TRANSACTION” METER: Meter didn’t respond to first volume A A A


COMMUNICATION RE-TRANSMIT request

427 – 429 Reserved for future “In-TRANSACTION”


METER errors related to data
transmission

430 “IDLE” METER: F030.2MM (MM = Meter no) A A A


ERROR PULSE LIMIT REACHED

431 “IDLE” METER: F030.3MM (MM = Meter no) B B B


REVERSE FLOW LIMIT REACHED

432 “IDLE” METER: F030.4MM (MM = Meter no) B B B


FORWARD FLOW LIMIT REACHED
Active fillings using other meters.

433 “IDLE” METER: F030.4MM (MM = Meter no) F F F


ILLEGAL FORWARD FLOW LIMIT
REACHED No active fillings. All fuelling points are
IDLE.

434 Not used

435 “IDLE” METER: Meter not responding to communication A A A


COMMUNICATION LOSS
No. Error/Event Description Classification

IE IFSF U
C S

436 – 439 Reserved for future “In-TRANSACTION”


METER errors related to data
transmission

440 WIP CALIBRATION DOOR STATUS WIP calibration door opened or closed A A A
CHANGE

441 WIP STATUS BIT “CALIBRATED” SET H H A

442 WIP STATUS BIT “LAST CALIBRATION H H A


FAILED”

443 – 499 Reserved for future “In-TRANSACTION”


METER errors related to data
transmission

500 NOZZLE SECURITY ALARM Dual nozzle switch error. B B B

Check that both magnets of nozzle are


mounted and that nozzle switches has not
been tampered with or disconnected.

501 BEZEL DOOR OPENED Door security feature. Bezel door D D D


(F066.005) has been opened when armed.

To clear error login to maintenance mode


with either engineer or WSA depending on
F066.000 setting. To clear with WSA log in
to an F066 parameter is required.

502 BEZEL DOOR CLOSED A A A

503 HYDARULIC CABINET DOOR OPENED Door security feature. Hydraulic door D D D
(F066.005) has been opened when armed.

To clear error login to maintenance mode


with either engineer or WSA depending on
F066.000 setting. To clear with WSA log in
to an F066 parameter is required.

504 HYDARULIC CABINET DOOR CLOSED A A A

505 DOOR SECURITY ARMED A A A


No. Error/Event Description Classification

IE IFSF U
C S

506 DOOR SECURITY DISARMED A A A

507 COMMUNICATION LOST OVER CAN TO Will trigger an error 501 regardless of door B B B
SECURITY SWITCH BOARD status.

508 - 509 Not used

510 SWITCH BOARD or I/O-BOARD: All switches reported as “de-activated”. I e B B B


COMMUNICATION LOSS all nozzles in.

Device code = 0 → nozzle interface


replaced
Device code = 1 → I/O-board replaced

511 SWITCH BOARD or I/O-BOARD: Device code = 0 → nozzle interface B B B


BAD STATUS replaced
Device code = 1 → I/O-board replaced

512 SWITCH BOARD or I/O-BOARD: Replace the board since not reliable → F B B
ROM TEST FAILURE possibly false nozzle out.

Device code = 0 → nozzle interface


replaced
Device code = 1 → I/O-board replaced

513 SWITCH BOARD or I&O-BOARD: Replace the board since not reliable → F B B
RAM TEST FAILURE possibly false nozzle out.

Device code = 0 → nozzle interface


replaced
Device code = 1 → I/O-board replaced

514 - 519 Not used

520 EMT FEEDBACK OPEN LOAD EMT not connected B B B

521 VALVE ACTIVE FEEDBACK ERROR Valve disconnected when valve was in A A A
active state

Clear feedback errors based on settings of


F070.1mm.
No. Error/Event Description Classification

IE IFSF U
C S

522 VALVE INACTIVE FEEDBACK ERROR Valve disconnected when valve was in in- A A A
active state

Clear feedback errors based on settings of


F070.1mm.

523 MOTOR ACTIVE FEEDBACK ERROR Motor disconnected when valve was in B B B
active state

Motor overload protection might have


triggered.

Clear feedback errors based on settings of


F055.1mm.

524 MOTOR INACTIVE FEEDBACK ERROR Motor disconnected when valve was in in- A A A
active state.

Clear feedback errors based on settings of


F055.1mm.

525 – 529 Not used

530 MPI CONFIG ERROR C C C

531 MPI PULSE OUTPUT LAG Flow exceeds maximum possible pulse B B B
output rate

532 PREMIUM DIESEL ADDITIVE ERROR Device code: B B B

0 = Additive configuration error


1 = CAN communication error
2 = Additive tank empty
3 = Additive tank-door open
4 = Additive motor failure
5 = Additive injection fell short
6 = Additive flow error
7 = Additive reset failed

533 – 531 Not used

600-601 Reserved

602 – 609 Not used


No. Error/Event Description Classification

IE IFSF U
C S

610 FAT OPEN FAILURE A A A

611 FAT WRITE FAILURE A A A

612 FAT READ FAILURE A A A

613 FAT DIRECTORY FAILURE A A A

614 FAT DELTETE FAILURE A A A

615 – 619 Not used

620 BOARD REGION MISSMATCH F F F

621 – 649 Not used

650 STARTUP Logged @ startup after reset A A A

Device# Shut-down cause


00 Power-loss
01 Soft Reset – power dip
02 Hard Fault
03 Unexpected Irq#
04 Watchdog Reset
05 Soft Reset – Security change
06 Soft Reset – BTL updated
07 Reset button
08 Start on battery
09 n/a
0A Out of mail buffers
0B RTOS error
0C Soft Reset – Debug
enable/disable
0D Soft Reset – Disp App updated
0E Soft Reset – iSense cmd
0F Soft Reset – Cold Start
10 Soft Reset – Force exit from
TCP/IP maint mode

651 SHUT-DOWN Shut down due to e g Power loss or Reset C C C


button

652 – 799 Not used


No. Error/Event Description Classification

IE IFSF U
C S

800 FP ADDRESS NOT CONFIGURED Pump is set to operate in serial mode G G G


(POS) but no protocol address has been
configured.

801 FACTORY DEFAULT NOT SAVED Factory default data is not saved. G G G

802 - 899 Not used

900 - 989 Not used

990 SW EXCEPTION Device No: F F F


0: Task tried to create RTOS Mail that was
of invalid size.
1: Mail buffers exhausted
2: Failed to create RTOS Task
3: Failed to start RTOS Task
991 TASK HEART BEAT TIMEOUT Task didn’t send heart beat to WDOG task A A A
in time. Will eventually result in Watchdog
reset.

Lnoz# Device#
1 Bit 0 = Task Mbx 1 (LR Wdog
Task)
Bit 1 = Task Mbx 2 (LR Initial
Task)
Bit 2 = Task Mbx 3 (LR Rom Test
Task)
Bit 3 = Task Mbx 4 (LR test
Task)
Bit 4 = Mbx 5 n/a
Bit 5 = Task Mbx 6 (LR Syscon
Task)
Bit 6 = Task Mbx 7 (LR Sales
Task)
Bit 7 = Task Mbx 8 (LR Maint
Task)
2 Bit 0 = Mbx 9 n/a
Bit 1 = Task Mbx 10 (LR iSense
task)
Bit 2 = Task Mbx 11 (LR
Flexmem Task)
Bit 3 = Task Mbx 12 (LR DAUP
Task)
Bit 4 = Task Mbx 13 (LR UART3
Task)
Bit 5 = Task Mbx 14 (LR UART4
Task)
Bit 6 = Task Mbx 15 (LR CAN
Task)
Bit 7 = Task Mbx 16 (LR Display
Task)
3 Bit 0 = Task Mbx 17 (LR WIP
Task)
Bit 1 = Task Mbx 18 (LR ATC
Task)
Bit 2 = Task Mbx 19 (LR Coriolis
Task)
Bit 3 = Mbx 20 n/a
Bit 4 = Task Mbx 21 (LR nonvol
Task)
Bit 5 = Task Mbx 22 (LR EMT
Task)
No. Error/Event Description Classification

IE IFSF U
C S

Bit 6 = Task Mbx 23 (LR FAT


Task)
Bit 7 = Task Mbx 24 (LR POS
Task)
4 Bit 0 = Mbx 25 n/a
Bit 1 = Task Mbx 26 (non-LR
Initial Task)
Bit 2 = Task Mbx 27 (non-LR
test Task)
Bit 3 = Task Mbx 28 (non-LR
Maint Task)
Bit 4 = Task Mbx 29 (Non-LR
iSense Task)
Bit 5 = Task Mbx 30 (Non-LR
display Task)
Bit 6 = Task Mbx 31 (Non-LR
switch Task)
Bit 7 = Task Mbx 32 (Non-LR
sales Task)
5 Bit 0 = Task Mbx 33 (Non-LR
POS Task)
Bit 1 = Task Mbx 34 (Non-LR
nonvol Task)
Bit 2 = Task Mbx 35 (Non-LR VR
Task)
Bit 3 = Task Mbx 36 (Non-LR
Proportional Task)
Bit 4 = Task Mbx 37 (Non-LR
system trace Task)
Bit 5 = Task Mbx 38 (LR SPI2
Task)
Bit 6 = Task Mbx 39 (nonLR
preset Task)
Bit 7 = Task Mbx 40
(LR_mpiTask)
6 Bit 0 = Task Mbx 40
(LR_dieselAdditiveTask)
7 Bit 0 = Task Mbx 49 not used
8 Bit 0 = Task Mbx 57 not used
No. Error/Event Description Classification

IE IFSF U
C S

992 - 999 Not used