You are on page 1of 2

SE9301/SE9302, description and measuring

Show All Profiles

Valid for serial numbers


Model Production site Serial number start Serial number stop
A60H Volvo

Op nbr 302-934

Tools:
88890074 Multimeter
9998699 Adapter
9990062 Cable
88830139 Break out harness
9990014 Break out harness
9998699 Adapter
9990062 Cable
88890167 Break out harness

Description

Function Measures the machine's load weight using the load on


two sensors located diagonally on the bogie beams
(SE9301 left front and SE9302 right rear).
References Wiring diagram WD903
Tech Tool
tests
Miscellaneo
us

V2A53, supply 5V
V2A54, ground
V2A56, supply 5V
V2A55, ground
VAB17, signal load
VAB18, signal load

Control measurement

Measuring point Correct value Condition Test method


≈0Ω
2–

SE9301: 3 – VB17 ≈0Ω


SE9302: 3 – VB18
≈∞Ω
1–

3–
≈5V
1–

Verification measurement

Measuring point Correct value Condition Test method


[T1]i
SE9301: V2B17 – V2A55 ≈ 1.2 V
SE9302: V2B18 – V2A54 ≈ 1.2 V

[T1]The values apply to an unloaded machine on level ground.