Professional Documents
Culture Documents
325L MERI G How To Troubleshoot A Short-To-Ground in Power Wiring
325L MERI G How To Troubleshoot A Short-To-Ground in Power Wiring
Page 1 of 1
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 325 LN EXCAVATOR 3LL
Configuration: 325, 325 L AND 325 LN EXCAVATORS 3LL00001-UP (MACHINE) POWERED BY 3116 ENGINE
Service Magazine
1989/03/27
Media Number -SEBD1960-00 Publication Date -27/03/1989 Date Updated -27/03/1989
Reference: Understanding Causes Of Blown Fuses And Tripped Circuit Breakers and
Understanding "Shorts," "Opens" and "Intermittents in this issue.
1. Disconnect one wire from the applicable circuit breaker or remove the fuse.
2. Temporarily connect a 9W1280 (24V) Lamp (or any 35 to 90 watt lamp) across (parallel to)
the fuse holder or circuit breaker.
NOTE: Be sure temporary connections are reliable and will not cause shorts (unwanted
connections).
4. To find the actual location of the short, disconnect, move, push/pull, and/or disturb the wiring
and components in the effected circuit until the light blinks "on or off" according to physical
motion.