You are on page 1of 4

Project ProNo.

Page
1

Item
1

HALFEN Design Software HTA, Version 2.96

The design does only apply to the designated HALFEN product. The load bearing capacity of
third party products, appearing to be identical in construction, might differ. For this
reason, the software provider does not extend warranty if non-HALFEN products are used.

System parameters
Anchor channel HTA-CE 38/17 - A4 - 100 / 2, 2 Anchor
T-bolt HS 38/17 M 16 x (>= 69) FV/GV-S 4.6
Approval / Design method EN 1992-4 / EOTA TR047 / CEN/TR 17080 - ETA-09/0339
Shear load Without lever arm
Concrete C40/50, cracked
Reinforcement of concrete member No dense reinforcement
Edge reinforcement No edge reinforcement
© Leviat GmbH, Langenfeld, Germany
Leviat GesmbH, Leonard-Bernstein-Str. 10, 1220 Wien, Tel.: +43 1 259 6770

h = 150 mm l = 100 mm c11 = 75 mm c21 = 80 mm


cnom = 25 mm

Adjusting zone ±: Full variability

T-bolt xcbo.1 /scbo N cbEd V cbEd,y T-bolt scbo N cbEd V cbEd,y


[mm] [kN] [kN] [mm] [kN] [kN]
1 40 10.00 0.00

Utilisation: 100% - Verification successful

HTA 2.96
22/05/2024
Project ProNo. Page
2

Item
1

Calculation Summary Utilisation

Verifications for T-bolt


Tension NRd,s,s 32%
Shear VRd,s,s N/A
Combined loading NRd,s,s - VRd,s,s N/A

Verifications for cast-in channels


Channel lips - Tension NRd,s,l 100%
Channel lips - Shear perpendicular VRd,s,l,y N/A
Channel lips - Shear longitudinal VRd,s,l,x N/A
Flexure of channel MRd,s,flex 25%
Combined loading NRd,s,l - VRd,s,l N/A

Connection anchor - channel (Tension) NRd,s,a,c 60%


Connection anchor - channel (Shear) VRd,s,a,c N/A
Connection anchor - channel (Shear, longitudinal) VRd,s,a,c,x N/A
Combined loading NRd,s,a,c - VRd,s,a,c N/A

Verifications for concrete


Tension - Pull-out failure NRd,p 23%
Tension - Concrete cone failure NRd,c 93%
Tension - Concrete splitting failure NRd,sp N/A
Tension - Blow-out failure NRd,cb N/A
© Leviat GmbH, Langenfeld, Germany

Shear - Pry-out failure VRd,cp N/A


Shear - Pry-out failure (longitudinal) VRd,cp,x N/A
Shear - Concrete edge failure VRd,c N/A
Shear - Concrete edge failure (longitudinal) VRd,c,x N/A
Shear - Concrete edge failure, load parallel to edge VRd,c90 N/A
Shear - Concrete edge failure, load parallel to edge VRd,c90,x N/A
(longitudinal)

Combined loading NRd,c,p,sp - VRd,c,cp N/A

Verifications:

Steel
Leviat GesmbH, Leonard-Bernstein-Str. 10, 1220 Wien, Tel.: +43 1 259 6770

T-bolt

Maximum tension load (T-bolt): T-bolt 1 EN 1992-4, 7.4.1.3

62.80 2.00 10.00 < 31.40 kN 0.32

Local flexure of channel lips

Maximum tension load (T-bolt): T-bolt 1 EN 1992-4, 7.4.1.3 (2)

HTA 2.96
22/05/2024
Project ProNo. Page
3

Item
1

76 1.00 18.00 18.00 1.80

10.00 = 10.00 1.00

Flexure of channel EN 1992-4, 7.4.1.3

Decisive span between Anchor 1 and Anchor 2

580 1.15 125 < 504 0.25

Anchor
© Leviat GmbH, Langenfeld, Germany

Tensile load, Anchor 1, load position xcb,1 = 25 mm EN 1992-4, 7.4.1.3

18.00 1.80 6.05 < 10.00 0.60

Connection anchor - channel

Tensile load, Anchor 1, load position xcb,1 = 25 mm EN 1992-4, 7.4.1.3


Leviat GesmbH, Leonard-Bernstein-Str. 10, 1220 Wien, Tel.: +43 1 259 6770

18.00 1.80 6.05 < 10.00 0.60

Concrete

Tensile load - Concrete cone failure EN 1992-4, 7.4.1.5

Tensile load, Anchor 1, load position xcb,1 = 25 mm

HTA 2.96
22/05/2024
Project ProNo. Page
4

Item
1

9.76 1.50 6.05 < 6.51 0.93

7.80 40 76 32.68 50 342 0.66

171 75 0.66 80 N/A 0.68 1.00


© Leviat GmbH, Langenfeld, Germany

Tensile load - Pull-out failure EN 1992-4, 7.4.1.4

Tensile load, Anchor 1, load position xcb,1 = 25 mm

39.00 1.50 6.05 < 26.00 kN 0.23


Leviat GesmbH, Leonard-Bernstein-Str. 10, 1220 Wien, Tel.: +43 1 259 6770

11.70 40 3.33

HTA 2.96
22/05/2024