Fire Protection System Installation Guide

The document provides a list of firefighting equipment including wet firefighting piping, fire hoses, cabinets, pumps, tanks, hydrants, extinguishers, and a fire alarm system. Over 20 line items of equipment are listed along with quantities, specifications, and suppliers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
99 views1 page

Fire Protection System Installation Guide

The document provides a list of firefighting equipment including wet firefighting piping, fire hoses, cabinets, pumps, tanks, hydrants, extinguishers, and a fire alarm system. Over 20 line items of equipment are listed along with quantities, specifications, and suppliers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Fire Fighting System

Item Brand /Model Description Unit Qty.

1 Wet Fire Fighting Network

Piping Network - HDPE


Supplying & installing of piping network from Solid Wall Pipe HDPE, PN10, for system piping network c/w fitting, connections, and all accessories required to
complete the work to be in accordance with NFPA & local fire authority for the following diameter:
Misr el-nour
1 .1 Diameter size (6”). M.L 1250
Or equal

1.2 ----- ‫ئ‬


‫الش الصله‬ ‫حفر و ردم و اعادة‬ M.L 1250

Single Fire Hose Cabinet ( 2.5" )

Supplying & installing of surface mounted , single door fire hose cabint, 1mm
thickness red finish round bar hinges & latch lock,
(80X80X30)cm.

FIRE GUARD / 2.5" x 30mtr Fire hose ( Red, canvas, Single Jacket ) with 2.5" coupling.
2 Set 23
METEORY
2.5" jet spray fire hose nozzle ( M.Inst. , Branchpipe).

2.5" Angle Valve.

3 FIRE PUMP HES 500 GPM @ 8 BAR - NON-UL As NFPA Standard

Electric Drive Pump

3.1 Supply, test, commission and hand over of Horizontal end suction electric
drive fire pump of (500 gpm @ 8 bar), complete with pump accessories, N.o 1
fittings, valves, supports and all accessories to complete the works.

Diesel Drive Pump


Supply, test, commission and hand over of Horizontal end suction diesel drive
3.2
fire pump of (500 gpm @ 8 bar), complete with pump accessories, fittings,
FIRE GUARD N.o 1
valves, supports, diesel tank with pipes and all accessories to complete the
/ SEFECO /
works.
OR
Jockey Drive Pump
APPROVED
3.3 EQUAL Supply, test, commission and hand over of Vertical electric drive Jockey pump
of (15 gpm @ 8.5 bar), complete with pump accessories, fittings, valves, N.o 1
supports and all accessories to complete the works.
Supply & Install

Supplying & installing of steel pipe sch. 40 for fire protection pumping system
3.4
in the pump room including: L .S 1
- pumps suction and discharge headers
- painting, supports, hangers and all accessories to complete the works.

Supplying & installing of OS&Y, Check valves and fittings for Pumps
3.5 ------- and tanks.
L .S 1

3.6 ------- Supplying & installing of Electric Cable 4*35mm. M.L 30

Supplying & installing of Water storge tank (20m³) with inlet, mechanical float,
4 ------- over flow and drain.
N.o 3

5 ------- Supplying & installing of Sunsheld for Pumps and tanks. L .S 1

6 Siamese Connection
GIACOMINI / Supplying & installing of 4" x 2½" x 2½" Siamese Connection, Straight, Single
6.1
FIREGUARD Clapper, UL Listed / FM Approved.
2½" Quick Coupling, (W.P = 16 bar & B.P = 40 bar), c/w PVC cap
6.2 ------- , using for Siamese.
N.o 1

GIACOMINI /
6.3 4" Threaded x Threaded, Swing Check Valve, UL /FM.
FIREGUARD
KOLLING/
Supplying & installing of Wet Type Fire Hydrant 4" with 2 x 2.5"
7 RAPIDROP OR Landing coupling outlet with cap and chain.
N.o 1
EQUAL
FIRE EXTINGUISHER

8 METEORY Supplying & installing of 6 Kg Co2 fire extinguisher. N.o 2

Supplying & installing of 6 Kg stored pressure type, dry Powder Fire


9 METEORY N.o 32
Extinguisher, highly effective.

For TR1 & TR2 & RMU Roomssupplying & installing of CO2 system
10 ------- with 4 CO₂ Cylinders, 45 kg, with Discharge Nozzle, weighing device, N.o 3
Piping Network and Conventinal fire alarm system.

11 Single Fire Hose Cabinet ( 1" )

Supplying & installing of surface mounted , single door fire hose cabint, 1mm
thickness red finish round bar hinges & latch lock, (80X80X30)cm.
FIRE GUARD /
11 . 1 1" X 30 m Manual semi-rigd Hose reel with swing Arm ,Plastic Nozzle and 1" SET 1
METEORY
connection ball valve.

1" Ball Valve.

FIRE Search CO2


Supplying & installing of 2 Kg Co2 Fire Search fire extinguishe consists of one
12 METEORY N.o 2
firesearch flexible polymer tube.
Supplying & installing of 6 Kg Co2 Fire Search fire extinguishe consists of one
13 METEORY N.o 5
firesearch flexible polymer tube.
Supplying & installing of 10 Kg Co2 Fire Search fire extinguishe consists of one
14 METEORY N.o 2
firesearch flexible polymer tube.

making duke are for fuel tank with suitable hight which cover (110-150)% from
15 ------- tank with Sheld
N.o 1

Supplying & installing of 200 Littre AFFF Mobile Foam fire extinguisher,highly
16 ------- effective with manual activation.
N.o 1

Fire Alarm
Supplying & installing of fire alarm system and cables with PVC Recessed or L .S
17 1
EMT exposed pipes to connect network with FACP
FIREGUARD /
18 Supplying & installing of Conventional fire Alarm control panel UL. N.o 1
SIMPLEX
19 /APOLLO OR Supplying & installing of smoke sensor detector UL. N.o 48
20 APPROVED Supplying & installing of Heat sensor detector UL. N.o 4
21 EQUAL Supplying & installing of Manual call point. N.o 10
22 Supplying & installing of Siren. N.o 9
Fire Boards
23 ------- supplying & Installing boards for assembly point & emergency exits. N.o 15

Training
24 ------- Training a sufficient number of employees on how to use fire equipment L .S 1

Piping Network - ERW


Supplying & installing of piping network from ERW as per ASTM A-53, Sch40, c/w fitting, connections,
hangers, supports, coating and all accessories required to complete the work to be in accordance with NFPA
& local fire authority for the following diameter:
25 Diameter size 100 mm (4”) M.L 12
Linda OR
26 Diameter size 65 mm (2.5”) M.L 12
Equal M.L
27 Diameter size 40 mm (1.5”) 6
Valves
FIREGUARD/
Supplying & installing of OS&Y Gate Valve, Ductile Iron Body, 300 psi Working
28 APC/ or Pressure, 4" Size, UL / FM.
N.o 1
equal
Supplying & installing of 1" Automatic Air Vent, UL Listed / FM Approved with
29 ------- 1" valve.
N.o 1

30 ------- Supplying & installing of 2”, for Drain. N.o 1

Grand Total in L.E (Excluding VAT)