Selection Guide – Anchors for

Concrete Applications
ANCHOR TYPE KEY FEATURES SIZE RANGE (inches)

Trubolt® n
n
2018 IBC Compliant
Seismic zone (A-B) approved
Diameter: 1/4 – 1
Wedge Anchors ID STAMP n Fully-threaded
Length: 1-3/4 – 12
n Length ID head stamped
n Stainless steel clip
n Through-fixture fastening

Large Diameter n
n
Anti-rotation serrated washer
Extra large hex washer head
LDT with Zinc Plating
Diameter: 3/8 – 3/4
Tapcon (LDT) n Length ID head stamped Length: 1-3/4 – 6-1/4
Self-Threading Anchor n Through-fixture fastening

Multi-Set II® n RM: Flanged body to keep anchor


flush with surface of concrete
Diameter: 1/4 – 3/4
Length: 1 – 3-3/16
Drop-In Anchors n RL: Non-flanged body for Diameter: 1/4 – 3/4
recessed setting Length: 1 – 3-3/16
n RX: Designed for hollow core and Diameter: 3/8 & 1/2
post tension concrete Length: 3/4 - 1
n CL: Designed for one-sided forming, Diameter: 1/2 & 3/4
accepts coil rod Length: 2 & 3-3/16
RM RL RX CL

Dynabolt® n
n
Concrete, block and brick
Many choices of head styles
Diameter: 1/4 – 3/4
Sleeve Anchors n Through-fixture fastening
Length: 5/8 – 6-1/4
n Available in 304 stainless steel

For both Hollow (1/4" & 3/8" diameter) and Solid Concrete
(1/4" through 3/4" diameter) Applications

Tapcon®
Concrete Anchors with
Advanced Threadform
Technology™ SCOTS

Original Maxi-Set XL

66 Call our toll free number 800-848-5611 or visit our web site for the most
current product and technical information at www.itwredhead.com
Selection Guide

CORROSION RESISTANCE PERFORMANCE HEAD STYLES APPROVALS/LISTINGS

Trubolt® n Zinc-plated carbon steel to Ultimate Pullout Hex nut ICC Evaluation Service, Inc. # ESR-2251
Wedge ASTM B633, SC1, Type III Performance in 4,000 Tie-Wire version Underwriters Laboratories
cont’d
n Hot dipped galvanized to psi Concrete up to Factory Mutual
ASTM A-153 26,540 lbs. Caltrans
(1" diameter) Meets or exceeds U.S. Government G.S.A.
n Type 304 and 316 stainless steel
Specification A-A-1923A Type 4 (formerly
GSA: FF-S-325 Group II, Type 4, Class 1)

LDT n Zinc-plated carbon steel to Ultimate Pullout Finished bolt style


cont’d ASTM B695 & B633 Performance in 4,000 psi
n Type 410 stainless steel Concrete up to 23,266 lbs.
(3/4” diameter)

Multi-Set II n Zinc-plated carbon steel to Ultimate Pullout RM: Flanged body GSA: A-A-55614 Type 1
Drop-In ASTM B633, SC1, Type III Performance in RL: Non-flanged body (Formerly GSA: FF-S-325 Group VIII)
cont’d
n Type 304 and 316 stainless 4,000 psi Concrete Use any bolt or Underwriters Laboratories
steel up to 9,480 lbs. threaded rod Factory Mutual
(3/4” diameter) Caltrans

Dynabolt® n Zinc-plated carbon steel to Ultimate Pullout Flat head GSA: A-A-1922A
Sleeve ASTM B633, SC1, Type III Performance in Hex nut (Formerly GSA: FF-S-325 Group II, Type 3, Class 3)
cont’d Factory Mutual
n Type 304 stainless steel 4,000 psi Concrete Acorn nut
up to 8,900 lbs. Tie-Wire
(3/4” diameter) Round head
Threshold flat head

Tapcon n Patented Trade Secret Ultimate Pullout Hex head Blue Climaseal™
cont’d
Climaseal® coating Performance in Phillips flat head ICC Evaluation Service, Inc.– ESR-1671
n Type 410 stainless steel 4,000 psi Concrete ICC Evaluation Service, Inc.– ESR-2202
up to 2,380 lbs. Miami-Dade County
Florida Building Code
The above is for the Original and 410 SS Tapcon only.
410 Stainless Steel
For data on other Tapcon products see their product pages as follows: Miami-Dade County
Tapcon Maxi-Set on page 94, Tapcon SCOTS on page 94, Tapcon XL on page 98, and Florida Building Code
Tapcon StormGuard on page 100.

Because applications vary, ITW RED HEAD cannot guarantee the performance of this product. Each customer assumes all responsibility and risk for the use of this product. The safe handling and the suitability of this product for