1. Scrofiing
2. Start
3. top
4, Change setting
5. Change setting
6. Reset (return to basic display)
7, Display
8. Left upper segment of display
9. Left lower segment of display
10. Pressure indicator light
1.
12.
. Service indicator light
14,
18.
16.
17.
18.
19.
). Emergency stop
21.
‘Temperature indicator light
Operating hour indicator light
Air filter indicator light
Oil separator indicator light
Oil filter indicator fight
Motor indicator light
Power indicator light
Display indicator light
Remote control selecting switchThe electronic unit has five menus, four of which can be used by the operator. The fifth menu
contains the factory settings of the compressor. Access fo the factory settings menu requires a
special code.
| — setting unloading pressure
setting output pressure
— compressor unloading time
— automatic start after power cut-off
— condensate removal, blow-oul time
— condensate removal, pause time
~ air filter service potiod
— oil change period
— oil separator service period
~ oil filter service period
® ©} SERVICE
@al ~ compressor number
“) MULTIPILOT | — selecting pressare contro! point
MENU.
— measurement off / on / measurement
®@ 04} DRYER | temperature of dryer
‘The basic display menu shows the compressor’s running mode and information on the com-
pressor’s various functions.
The other menus are for programming. They are accessed from the basic display menu by
simultaneously depressing the @) and @ keys for five seconds. All indicator lights will go
on and the display starts flashing. Then you choose the desired menw code (01, 02, 03 or 04)
using the @) key.
The unit now enters programming mode, and the desired function is brought to the display
using the scrolling key C). The change the numerical value on the display, use the @) and
© keys. The value on the display starts flashing to indicatethe change. When flashing stops,
the value becomes the new setting.
‘The basic display can be entered from all menus by depressing the reset key, The basic dis-
play wil} also return after { minute if the panel is not used. -Basic display
When the compressor is switched on, the unit always shows the basic display.
If the motor is running, the display shows a dot and the output pressure (the dot is shown
when the compressor is in output mode, not when unloading).
If the motor is stopped, the display shows compressor’s renning mode.
Compressor running modes:
DISPLAY
Operating “hours 9 Hight 0 on tied)
Operating hours flashing (third)
Service light on (fourth)
Ai filter light on (fifth)
* On compressors with program version 1 or later.
RUNING MODE
Compressor switched off
Compressor i in blow-out mode
Stop command given and compressor run-
ning unloaded before stopping
Compressor switched on
| Compressor in stand-by mode and can n start
{at any time
the following functions:
FUNCTION
Output pressure :
Compressor temperature
Dew point temperature of dry.
Operating hours
Output hours flashing
“| Change oil
Replace air filter
Replace oil separator *
Replace olf filter *
Compressor runnin mode on display
ayUser menu
To enter the user menu fram basic display when the compressor is stopped, select code OL
Use the scrolling key €} o select the desired function for programming. The numerical va-
lues can be changed with the @) and @ keys. The value flashes on the display to indicate
change. When flashing stops the value becomes the new setting.
‘The following functions can be programmed through the user menu:
— setting unloading pressure
The pressure value at which the compressor goes over to unloading. The pressure indi-
cator light and the left upper segment of the display illuminate when the unloading
pressure is in the programing mode.
The output pressure shifts as the unloading pressure is changed (pressure difference re-
mains constant).
The unloading pressure set at the factory is equal to the compressor’s max. pressure,
which cannot be exceeded.
~ setting output pressure
The pressure value at which the compressor goes over to full output.
The pressure indicator light and the left owec segment of the display illuminate when
the output pressore is in the programming mode.
A Changing output pressure will also change the pressure difference.
~ compressor unloading time
The unloading time determines how long the compressor runs unloaded before auto-
matic stopping.
The operating hour tight illuminates when the unloading time is programmable.
-- altomatic starting after power cut-off
The function is disabled by setting the value to 0.
__ Other values define the starting delay of the compressor when power is tumed on again
The operating hour light flashes when automatic starting is programmable,
If aufomatic starting after power cut-off is enabled, a warning labet of this
must be placed on the compressor.
— condensate removal, blow-out time
Condensate removal biow--out time in seconds,
The air filter light illuminates wher this function is programmable.
A ‘Too short condensate removal at too long intervals may cause water to enter
the network, Humid and warm intake air requires longer and more frequent
condensate removal.
Make sure that the water separator becomes empty in the set blow-out time.
~ condensate removal, pause time
Condensate removal pause time in seconds.
‘Phe oil separator light iluminates when the condensate removal pause time is program-
mable. cService menu
To enter the service menu from the basie display when the compressor i stopped, select
code 02.
Use the scrolling key oO to select the desired service item and to set its new lifetime after the
Service.
‘The numerical values can be changed using the @) and &) keys. The value flashes to indicate
the change. When flashing stops, the value becomes the new setting.
‘There are four service points:
~ oil change period
‘The service light illuminates when the new oil change time can be set.
~ air filter replacement time
The air filter light iluminates when the new service time can be set for the air filter.
— vif separator replacement time.
\ The oil separator tight iMuminates when the new service time can be set for the oil sep-
arator.
~ oil filter replacement time
‘The oil filter light {Numinates when the new service time can be set for the oil filter.
Note! After replacing filters, the service time must always be set on the dis-
play.
Multipilot menu
The settings in this menu are used when the compressor is connected 1» Maltipilot control
through an RS 485 communication line. In that case an additional data communication card is
needed.
‘To enter this menu select code 03.
= <_ mpressor number
The display shows alternately the text RS 485 and the compressor number, When no
indicator lights are on, the compressor number can be changed. The number flashes
quickly as its value is being changed.
~ selecting pressure controt point
The compresor’s pressure control point can be changed hore. The text LOCAL indicates
control by the compressor, while the text PILOT means control by the Multipilot sys-
tem.
Dryer menu
To enter this menu select code 04.
In this menu you select temperature measurement OFF or ON*. Displayed text: OFF/ON*.
Alternative; Measurement of dryer temperatuse ON, Displayed text now: DRYER.
‘The alarm limit of the temperature measurement is set at 50° C and the stopping limit is set at
60° Cat works. The alarm limit of dryer temperature is set at 15° C at works.
* Not a standard operation ‘AGCompressor’s settings
Settings changeable by the user
Unloading pressure 3 bar ~ compressor max. | Max. pressure (See
pressure Technical Data)
‘Gutput pressure “12 bat — compressor max. | Ap=1 bar 1)
pressure
Untoading time 20 min 3or5 mio
‘Automatic start delay } tor id - 240s 0
Condensate removal
— blow-out time 1-208 2s
— pause time 10 - 120s 60s
ur filter replacement interval | 0 ~ 40006
Oil change interval 0- 4000h
‘Oil separator replacement inter- | 0~ 8000 h
val
Oilfilter replacement interval | 0- 4000h
1) Ap = difference between unloading and output pressure
Factory settings, not changeable by the user
Motor acceleration time
wun. unloading time
Unloading time before stopping | 1- 480s
Blow-down ime Fixed = not adjustable
Emergency stop pressure 3-15 bar 10% over max. pressure
Stopping temperature 85 - 125°C ns°C —
(temp.switch)
‘Alarm temperature Fixed = not adjustable 160°C
Dryer dew point alarm tempera~ | 0 - 80°C 15°C
ture
Max. pressure 3-15 bar Cf. Technical Data
Fixed = not adjustable 50 mbar
Pressure relief valve a 14,5 bar
Temperature of air supplied to | 0-125°C { 50/60" C
network’, alarm/stopping
* Not a standard operation Wy