DETAILS OF PROPOSED LAYING OF GAS PIPELINE CROSSING AT KM 821/19A - 17A KRI-GMG SECTION
821/700 N Water Supply Pipe Line
Proposed Gas Pipeline Existing Electric Cable N OFC
C/L of ROB Dia. 200mm N TV Cable
NGP END CR BOUNDARY A Y Oil/Petroleum/ Gas Pipe line
WR END
10.00 7.90
EP: 821/19N
EP: 821/19N C/L Of track-4
To Nagpur
KHAPRI 5.00 3.40 7.50 GUMGAON
4.70 3.10 7.15
EP: 821/20N C/L Of Track-3
EP: 821/22 9.90 8.50
51.5 Mtrs.
5.35 12.60
EP: 821/20A EP: 821/19N
C/L Of Track-2
KHAPRI 5.06 2.95 7.60 GUMGAON
5.06 2.50 7.80
To NCI Hospital
C/L Of Track-1
EP: 821/22N
5.00 EP: 821/20N 19.00
NGP END WR END
CR BOUNDARY
A
821/700
ELEVATION
51.50 Mtrs
RAILWAY BOUNDARY
RAILWAY BOUNDARY
C/L DN C/L UP 3rd Line 4th Line
To NCI Hospital 4.65 14.40 5.15 To Nagpur
0.9
G LEVEL G LEVEL
3.00 M
SECTION A-A Proposed 200mm Dia. Gas Pipeline
PIT Gas Flow Direction with Casing 300mm PIT
1. Exact location of crossing between KM., No. of Elect. Mass, T.P. No. In Between EP No. 821/19A to 821/17A
2. Dia of proposed pipe for OFC/TV Cable/Water Supply pipe line/ Oil/Gas Pipeline etc pipeline crossing 8" DIA CS API 5L Gr X 52
3. Distance of Railway boundaries from center line of track NA
4. Rail Level, Formation Level. Groun level should be marked on Sketch Yes
5. Direction of flow if water supply pipeline Yes
6. Distance of center line of crossing from E.P./T.P. 21 Mts
7. Feasibility of site to be maintioned Yes
8. Trial pit Details Trial Pit will be available outside the railway boundry
9. Bench Mark To be done
The site is feasible for laying of OFC/Water pipeline/TV cable/Oil/Gas pipeline crossing from Engineering point of view.
Note :- 1) Work Should be carried out under the supervision of railway representative.
2) All guideline for laying of Gas Pipeline as per RDSO - BS 105 Oct-2009 to be followed during execution of work.
APPLICANT:-HCG NAGPUR PVT. LTD.
APPLICANT SSE (P-WAY) SSE (SIGNAL) SSE (TELE) SSE (TRD) ADEN ADSTE ADEE (TRD) DATE: 03-02-2025
PROPOSED RAILWAY LINE CROSSING
DRG. No. HCGNPL/RW/003 REV. 00 NOTE TO SCALE