You are on page 1of 7

Bag House

Bag House

Introduction
Location:
Bag house is located outside the converter area where
the collected dust is sent by the dust control motors to
the bag house

Function:
The bag house sucks all dust from converter with the
help of dust collector motors and emits with the help of
exit blower. The collected dust will form in bag house in
the bags provided and most of the accumulated dust will
be emitted by exit blower. Remaining will be emitted by
screw conveyor and rotary valve motors and its
assemblies where pressurized air is supplied by the bag
house solenoids at specified time intervals which is
controlled by timer controller circuit.
Bag House Equipment Boundary
Component Function
Exaust Blower Sucks the accumulated dust with high power vacuum and emits with high power blowing.
Case Bearings Rotates the motor assemblies with out any friction.
Screw Conveyor motor assembly Collect and Clean the accumulated dust inside the bag house and escalate the collected dust to upstream process
Rotary valve fan sprocket and chain drive Drives the rotary valve drum with the help of rotary vave motor and controls the exceeding action of the rotor.
Rotary valve assembly
Emits the dust which is collected by screw conveyor and pressurized air to outside with the help of wiping arms which
is connected with the motor assembly.
Solinoid Valves
Force the powerful pressure air in to the bag house to fell down the accumulated dust in the bags and its
surroundings.
Magnetic door Controls the balanced air pressure inside the bag house and opens when balanced air exceeds.
Access doors Opens while balanced air pressure exceeds.
Dampers Allows the collected dust while normal running and blocks the dust in case of alarms.
FRLS Filtering the dusty air, regulating the collected air and then allows to the process.
Foundation Bolts Lock the motor assemblies and the bag house assemblies to the base.
INSPECTION THROUGH CLEANING
Unit Diagram
Run/
Stop
Insp
Point
Component
Inspection
Standard
Method Tool
Action in case
of abnormality
Time
(min)
Freq
R 1 Exhaust Blower No vibration or abnormal
noise present
Open and check 1 D
R 2 Baghouse motors Observe that no dirty air
passing through exaust
blower (at duct opening -
outside building)
Open and check 3 D
S 3 Solenoid valves /Diverter
valves
Valves operating properly.
The air releasing sound is
normal,soleniod valves
basement mounting is
properly, no air leakage
Tighten,cleanup
replace
5 M
R 4 Magnetic Door magnetic door at the proper
place ,and proper function of
magnahelic
Tighten,cleanup
replace
5 M
R 5 Flexible joints Inspect flexible joint between
rotary,screw
conv,enclosureand exaust
blower, No air leakage is to
be present
Tighten,cleanup
replace
5 M
R 6 Screw Conveyor Drum Drum is rotating smoothly,
rotation with out any noise
Open and check for
friction
3 M
S 7 Access door Door has to be closed Check for high
pressure, Close the
door
1 M
S 8 Case bearings of Baghouse
motors
No vibration or noise to be
present, no abnormal
temperature
Lubricate case
bearings
5 M
S 9 Rotary valve fan sprocket and
chain
No loose chain, no vibration
or noise to be present, no
abnormal temperature
Lubricate rotary fan
sprocket and chain
5 M
S 10 Baghouse motors - exhaust
blower, screw conveyor, rotary
valve
No vibration or noise to be
present, Exhaust Blower V
Belt should not be loose
Remove the side
cover of Exhaust
blower ,Rotary and
screw conv fans and
Inspect the Impeller
12 M
R 11 Foundation bolts of all motors no vibration or noise to be
present
Check ,replace 5 T
R 12 Check fire dampers &FRLS No loosen contacts,free open
/close movement
Tighten,cleanup
replace
5 T
3
1
2
4
5
7
8
6
9
10
11
12
12
Issues
Bag chocking
Chain broken
RV jam
Blower belt damage
Bag Brocken
Explosion vent damage
Electric wire loose
Qualification