Acetylene, being one of the widely used compressed gases, is nowadays produced on a larger scale using
acetylene plants. As with any regular compressed gas generation equipment, these plants are tted with
several parts that play a key role in their functioning. These parts require regular maintenance and
cleaning to ensure their long-term performance. The generator is one of the key parts of the acetylene
production equipment (https://www.rexarc.com/acetylene-plants) that requires regular cleaning. The
cleaning intervals will depend upon the amount of acetylene produced by the generator, as well as the
quality of the carbide received. Experts at Rexarc, a leading manufacturer of acetylene plants
(https://www.rexarc.com/), components (https://www.rexarc.com/components-parts), and acetylene
generator, suggest that this cleaning must be carried out at least once in a year. Also, it can be conducted
when the production reaches 2 million cubic feet. This cleaning needs to be conducted in a special way.
(https://www.rexarc.com)
This post gives away special tips for cleaning acetylene gas generator machines
(https://www.rexarc.com/acetylene-generator).
HOME ABOUT US ACETYLENE PLANTS TECHNICAL SERVICES NEW PRODUCTS
Steps for Cleaning Acetylene Gas Generator in Your Facility

What is the right time to clean the generator? This is one of the most obvious questions that experts at
Rexarc have to answer, when their clients approach them with cleaning doubts. They always say that the
generator must be cleaned when the paddles of agitator start touching the ferro silicates at the bottom of
the tank. As, this contact in icts excessive wear and tear on the paddles, or may even break them, thereby
a ecting the functioning of an agitator (https://www.rexarc.com/blog/how-to-maintain-agitator-shafts-in-
acetylene-plants/). Here’s how users can go about the cleaning procedure:

1. Empty the Carbide Hopper before Cleaning the Generator: As a rst step, the carbide hopper
(https://www.rexarc.com/carbide-hopper) must be emptied before starting with the cleaning procedure.
Once the carbide is exhausted from the hoppers, locate the switches on the hopper, and turn them to o
position. Some generators utilize 1,200 and 5,000 pound capacity carbide hoppers. If it is not possible to
empty carbide from these hoppers, then remove the inspection plates of hydraulic feed valves. Next,
check the seat of the feed valve to ensure positive closing during the cleaning operations.

2. Turn on the Agitator: In the motor control panel, locate the agitator timer control box, and put it in
the ON position. This will help prevent the entry of the carbide into the generator, as well as allow the
agitator to run continuously.
(https://www.rexarc.com)

HOME ABOUT US ACETYLENE PLANTS TECHNICAL SERVICES NEW PRODUCTS

3. Ensure the Air System Inlet Valve is Kept Open: Located the air system inlet valve, and ensure that it
is kept open.

4. Close the Flashback Arrestor Inlet and Outlet Valves: Next, close the inlet and outlet valves on the
ashback arrestor. This will help you withdraw the generator from service. Also, turn o the hopper
toggle switches.

5. Close the Charging Manifold Drainback Valves: Now, proceed to the charging manifold locate the
drainback valves and close them.

6. Close the Drainback Manifold Outlet Valves: Check on the outlet valve on the drainback manifold,
and slowly close it. Now, the generator will be completely isolated, so you can dilute the lime water and
drain the generator tank.
7. Record the Meter Reading: In the next step, note down the water meter reading.

(https://www.rexarc.com)
8. Open the Generator Inlet Water Supply Valve: Now, open the inlet water supply valve of the
generator, and turn the water temperature instrument control knob to the left, until it stops moving. This
will allow the water to enter the
HOME generator.
ABOUT US ACETYLENE PLANTS TECHNICAL SERVICES NEW PRODUCTS

9. Open Generator Relief Valves: Move handles to the vent position to open the generator relief valves
(https://www.rexarc.com/blog/why-your-acetylene-plant-may-need-an-upgraded-generator-relief-valve/).
This will help vent pressure from the tank.

10. Insert a Pin into the Residue Drain Pilot Valve: Once the relief valves are opened, next insert a pin
of size 1/4ʺx 3ʺ into the residue drain pilot valve. This will help keep the drain valve open. Add
approximately 1,100 to 1,200 gallons of water, and monitor the water reading to ensure the same.

11. Check the Temperature on the Water Temperature Control Instrument: Continue lling the
generator tank with running water until the temperature is reduced to 90°F. This temperature change can
be noticed on the control instrument used for controlling the water temperature
(https://www.rexarc.com/water-temperature-controls-upgrade). If the temperature is above 90°F, then
continue adding water until the temperature drops down.

12. Turn the Temperature Inlet Control Knob to the Original Position: Once the temperature drops
below 90°F, turn the water temperature instrument control knob to its original position. This will stop the
water from entering in the generator. Open low limit test valve and watch low level alarm gauge. Replace
or clean control units if water is below low limit test valve before the low limit alarm gauge drops to 7
PSIG. Turn o alarm bell after this test. During the test, ensure that nitrogen pressure is maintained at 6
PSIG, as it will help in maintaining the tank pressure while draining the tank.

Once the tank is empty, check for the presence of acetylene. If acetylene traces are found, then repeat
steps 10 to 12. Repeat this procedure until no acetylene is found inside the tank when emptied.

13. Turn O Power Supply to Agitator: Once the tank is empty, turn o electrical power to drive motor
of the agitator. Next, reset timer control of the agitator. Tag or lock out all generator energy systems as
per the OSHA tagout/logout procedures.

14. Purge Generator Tank and Carbide Hoppers with Nitrogen: This can be conducted in the following
ways:

a. Hoppers: Charge hoppers to 10 PSIG nitrogen pressure. This limit needs to be achieved for each
hopper, and vent to the atmosphere. Repeat this procedure three times.
b. Generator Tank: Charge the generator tank up to 10 PSIG pressure, vent to the atmosphere, and
repeat this procedure for three times.
After purging, ensure that safety valves of the tank and hopper are in the open position. Check the tank
interior using explosion meter. Insert the probes through the water to test valves. If reading shows an
(https://www.rexarc.com)
explosive atmosphere then continue purging tank with nitrogen until non-explosive reading is shown on
the meter. Always ensure that the purging is conducted in su cient ventilation, as this helps prevent
nitrogen accumulation
HOME in theABOUT
air, which
US mayACETYLENE
lead to asphyxiation.
PLANTS TECHNICAL SERVICES NEW PRODUCTS

15. Remove the Manhole Cover and the Screwfeed Cover Plates: After purging, remove the manhole
cover plates and the screwfeed cover plates of the generator. Clean the tank interior using water hose in
high velocity. Use a wooden paddle to scrap out heavy particles that are settled at the bottom of the
manhole.

Caution: Avoid using a metal scraper or metal tool for scraping, as this may lead to a spark. Also, use only
explosion-proof extension light or ashlight to check inside the tank.

16. Perform Inspection of Various Parts: After the above steps, you can launch a detailed inspection of
other parts such as agitator shaft, agitator paddles for wear and tear, paddle mounting bolts for
tightness, and so on. Next, remove build-up from water spray nozzles, or the opening of equalizer pipe
elbow positioned below or ends of screwfeed tubes.

17. Remove Various Parts: Remove plug at tee from a pipe located at tank center riser. Clean the pipe
towards ashback arrestors with water. Remove plug located at the center of each ashback arrester, and
clean the ashback arrester with water. Remove o -center plug located at the bottom of each ashback
arrester to drain water from arresters. Flush again with water and replace all the plugs. Ensure to snug all
bolts when replacing manhole covers. Next, snug all bolts, and then tighten them across in the sequence
rather than going in bolt circle.

18. Ensure the Parts Are Functioning Properly: Re ll ashback arresters and generator with water.
Next, purge the generator with air-acetylene mixture and nitrogen before returning to service. Check high
and low-level alarms, and if controls have been changed. Check all lubrication points, as well as lubricant
levels in gear reducer.

19. Conduct Leak Testing: You can leak test hopper ll plug gaskets, hopper vent valves, and safety relief
valves with soap and water. Replace the leaking plugs immediately to avoid any complications in the
future.

When all these procedures are followed with safety precautions, they will ensure a proper and safe
acetylene generator cleaning. Do you still have doubts? Get in touch (https://www.rexarc.com/contact-us)
with experts at Rexarc. With a vast industry experience to their credit, the experts are always ready to
help you.
 PREVIOUS POST (https://www.rexarc.com/blog/know-how-acetylene-is-produced-in-acetylene-
plant/)
(https://www.rexarc.com)
NEXT  (https://www.rexarc.com/blog/how-to-maintain-agitator-shafts-in-acetylene-plants/)

  
HOME ABOUT US ACETYLENE PLANTS TECHNICAL SERVICES NEW PRODUCTS
(http://www.facebook.com/sharer.php?
(http://pinterest.com/pin/create/bookmarklet/?
(http://www.linkedin.com/shareArticle?

s=100&p[url]=https://www.rexarc.com/blog&p[title]=Tips
media=https://www.rexarc.com/blog/wp-
mini=true&url=https://www.rexarc.com/blog/wp-

for content/uploads/2019/02/Acetylene-
content/uploads/2019/02/Acetylene-

an  Generator-
Generator-

E ective(http://twitter.com/home?
Clean- Clean-

Acetylene
status=Tips Out.png&url=https://www.rexarc.com/blog&is_video=false&description=Tips
Out.png&title=Tips

Generator
for for for

Clean an an an

Outq&p[images[0]=https://www.rexarc.com/blog/wp-
E ective E ectiveE ective

content/uploads/2019/02/Acetylene-
Acetylene Acetylene
Acetylene

Generator-
Generator
 Generator
Generator

Clean- Clean (https://plus.google.com/share?


Clean Clean

Out.png)
Out+https://www.rexarc.com/blog)
url=https://www.rexarc.com/blog)
Out) Out&source=https://www.rexarc.com/blog)

Start Searching...

FOLLOW US ON

(https://www.linkedin.com/company/rexarc-

international-
 

inc-) (https://twitter.com/rexarcinc)
(https://www.youtube.com/channel/UC5yBW0nIj0Rb8OkQdRnvRAg/videos)

HOW TO VIDEOS
(https://www.rexarc.com)

HOME ABOUT US ACETYLENE PLANTS TECHNICAL SERVICES NEW PRODUCTS

CATEGORIES

 acetylene compressor (https://www.rexarc.com/blog/category/acetylene-compressor/)

 Acetylene Cylinders (https://www.rexarc.com/blog/category/acetylene-cylinders/)

 Acetylene Gas (https://www.rexarc.com/blog/category/acetylene-gas/)

 acetylene gas plants (https://www.rexarc.com/blog/category/acetylene-gas-plants/)

 Acetylene Puri ers (https://www.rexarc.com/blog/category/acetylene-puri ers/)

 Ammonia Scrubber (https://www.rexarc.com/blog/category/ammonia-scrubber/)

 ASME Pressure Vessels (https://www.rexarc.com/blog/category/asme-pressure-vessels/)

 Calcium Carbide (https://www.rexarc.com/blog/category/calcium-carbide/)

 Flashback Arresters (https://www.rexarc.com/blog/category/ ashback-arresters/)

 Industrial Gas Conference (https://www.rexarc.com/blog/category/industrial-gas-conference/)

 Industrial Gas Cylinders (https://www.rexarc.com/blog/category/industrial-gas-cylinders/)

 Others (https://www.rexarc.com/blog/category/others/)

 specialty gas equipment (https://www.rexarc.com/blog/category/specialty-gas-equipment/)

 Welding (https://www.rexarc.com/blog/category/welding/)
RECENT POSTS


(https://www.rexarc.com)
Understanding the Importance of ASME Standards for Pressure Vessels and Fabrication
(https://www.rexarc.com/blog/understanding-the-importance-of-asme-standards-for-
HOME ABOUT US ACETYLENE PLANTS TECHNICAL SERVICES NEW PRODUCTS
pressure-vessels-and-fabrication/)
October 29, 2019


How ASME Has A ected Pressure Vessels Manufacturing
(https://www.rexarc.com/blog/how-asme-has-a ected-pressure-vessels-manufacturing/)
October 10, 2019


Are You Using The Right Hose Connection For Your Gas Welding Hoses?
(https://www.rexarc.com/blog/are-you-using-the-right-hose-connection-for-your-gas-
welding-hoses/)
September 23, 2019


Tips for Piping Systems Used for Acetylene, Oxygen and Inert Gas Plants
(https://www.rexarc.com/blog/tips-for-piping-systems-used-for-acetylene-oxygen-and-
inert-gas-plants/)
August 28, 2019


Di erence Between Braze Welding and Gas Welding Explained
(https://www.rexarc.com/blog/di erence-between-braze-welding-and-gas-welding-
explained/)
July 11, 2019
Tweets by @rexarcinc
(https://www.rexarc.com)
Rexarc International
@rexarcinc

Know how ASME standard codes


HOME ensure
ABOUT US the safety of pressure
ACETYLENE vessels. bit.ly/2MWraru#pressurevessel
PLANTS TECHNICAL SERVICES NEW PRODUCTS
#asmepressurevessel #boiler #asme #safety #fabrication #Rexarc

QUICK LINKS
Home (/) FAQs (/faq)

About Us (/about-us) Blog (https://www.rexarc.com/blog/)

Components and Spare Parts (/components-parts) Sitemap (/sitemap)

Events & News (/news) Social Responsibility (/social-responsibility)

Contact Us (/contact-us) Image Gallery (/image-gallery)

Testimonials (/testimonials) Meet the People Who Built It (/meet-the-people-


who-built-it)

CONTACT US
 Rexarc International Inc.
35 East Third Street
West Alexandria, OH 45381
 info@rexarc.com (mailto:info@rexarc.com)
 1-937-839-5897 (tel:+19378395897)
(https://www.rexarc.com)
 Toll Free: 1-877-739-2721 (tel:+18777392721)
Phone: 1-937-839-4604 (tel:+19378394604)
HOME ABOUT US ACETYLENE PLANTS TECHNICAL SERVICES NEW PRODUCTS

FOLLOW US
(https://www.linkedin.com/company/rexarc-international-inc-) (https://twitter.com/rexarcinc)

(https://www.youtube.com/channel/UC5yBW0nIj0Rb8OkQdRnvRAg/videos) (/blog/)

NEWSLETTER SIGN-UP
Submit your email address to be noti ed about new equipment, sales and promotions.

Email* Subscribe

Copyright © 2019 Rexarc International, Inc. All Rights Reserved.

You might also like