Adjustment Dosing Additive Pump
Adjustment Dosing Additive Pump
SCREW IT
TURN
COUNTERCLOCKWISE
A LAP AND A HALF
READING
AREA
Finally tighten the lock nut and fix it with a key avoiding vary
the position of the sensor when tightening.
ADJUSTMENT HAWE
PROPORTIONAL CARD OUTPUT.
(ADDITIVE PUMP)
Adjusment Hawe Proportional Card Output
This adjustment
will be made only
when the card is
Adjust HAWE Card new, or has been
1 manipulated
2 3 4 5
1. Vertical Arrow. (Top accidentally
Side)
2. Turn Counterclockwise
until hear “Click”.
3. Turn Counterclockwise
until hear “Click”
4. MAX (520 Liters)
5. MIN (0 Liters)
Note: “Click” is heard
it in a soft tone
Adjusment Hawe Proportional Card Output
Login to level 2
Adjusment Hawe Proportional Card Output
Goes to
Commissioning Screen
Adjusment Hawe Proportional Card Output
(Max. Adjustment)
If we don’t get
this value must
adjust the No. 4
controller of HAWE
card.
520
Adjusment Hawe Proportional Card Output
(Min. Adjustment)
On this screen,
speed indicator of
additive pump, we get
the value "0" to launch
the additive pump
If we don’t get this
value must adjust the
No. 5 controller of
HAWE card.
Adjusment Hawe Proportional Card Output (Min. Adjustment)
When we adjust the
controller Nº5 of the
HAWE card, starts to
run the pump getting
between 2-3 liters.
Then "adjust" the
regulator
counterclockwise until
stop the additive
pump.
Adjusment Hawe Proportional Card Output
Plug to
override the
line
Water
output
Adjust of Dosing of Additive Pump
Pressure gauge to
control the system
pressure during the tests
at 6 Bar
Adjust of Dosing of Additive Pump
With 450 Kg/h selected and 6 pressure Bar, we running the test 3
minutes should get a quantity of 22,5 liters of water approximately
Adjust of Dosing of Additive Pump
It may be the case that the test result may not be correct,
then will be necessary to modify the degree of filling of
additive (normally the filling ratio is between 90% and 95%)
Adjust of Dosing of Additive Pump