ADJUST OF PROXIMITY SWITCH.
(ADDITIVE PUMP)
ADJUST OF PROXIMITY SWITCH.
 Screw the detector at maximum, ensuring that the reading
area is in contact with the teeth of the Hyd. motor and turn
counterclockwise a lap and a half.

SCREW IT
TURN
COUNTERCLOCKWISE
A LAP AND A HALF

READING
AREA
 Finally tighten the lock nut and fix it with a key avoiding vary
the position of the sensor when tightening.
ADJUSTMENT HAWE
PROPORTIONAL CARD OUTPUT.
(ADDITIVE PUMP)
Adjusment Hawe Proportional Card Output
 This adjustment
will be made only
when the card is
 Adjust HAWE Card new, or has been
1 manipulated
2 3 4 5
1. Vertical Arrow. (Top accidentally
Side)
2. Turn Counterclockwise
until hear “Click”.
3. Turn Counterclockwise
until hear “Click”
4. MAX (520 Liters)
5. MIN (0 Liters)
 Note: “Click” is heard
it in a soft tone
Adjusment Hawe Proportional Card Output

 Login to level 2
Adjusment Hawe Proportional Card Output

 Goes to Recipe Screen


Adjusment Hawe Proportional Card Output

 Goes to
Commissioning Screen
Adjusment Hawe Proportional Card Output

 Adjust the Degree of


Filling at 100% (Adjust
Screen)
Adjusment Hawe Proportional Card Output

(Max. Adjustment)

 Select 520 MAX


pushing the button
MENU 1 (Change).
Adjusment Hawe Proportional Card Output
(Max. Adjustment)

 Push MENU 2 to start


the additive pump
Adjusment Hawe Proportional Card Output
(Max. Adjustment)
 On this screen,
speed indicator of
additive pump, we
get the value "520"
to launch the
additive pump

 If we don’t get
this value must
adjust the No. 4
controller of HAWE
card.

 520
Adjusment Hawe Proportional Card Output
(Min. Adjustment)
 On this screen,
speed indicator of
additive pump, we get
the value "0" to launch
the additive pump
If we don’t get this
value must adjust the
No. 5 controller of
HAWE card.
Adjusment Hawe Proportional Card Output (Min. Adjustment)
 When we adjust the
controller Nº5 of the
HAWE card, starts to
run the pump getting
between 2-3 liters.
Then "adjust" the
regulator
counterclockwise until
stop the additive
pump.
Adjusment Hawe Proportional Card Output

 Finally these two settings MIN & MAX should be repeat to


achieve a balance between the two.

 Because adjusting the MAX, MIN is detuned and vice versa.

 After setting the HAWE card we can proceed to a adjust the


dosage of the additive pump.
ADJUST OF DOSING OF ADDITIVE
PUMP.
Adjust of Dosing of Additive Pump
Adaptation of additive system to adjust de dosaging with water

Plug to
override the
line
 Water
output
Adjust of Dosing of Additive Pump

 Must be set by default the degree of


filling at 90%
Adjust of Dosing of Additive Pump
 At Main Screen
(Manual Mode) adjust
the “Selected
Additive” to 450 kg/h
and we start to run
the additive pump.
Adjust of Dosing of Additive Pump

 With this valve (close a


little bit) we generate a
pressure at additive line (in
this case Water line)
approximately at 6 Bar
Adjust of Dosing of Additive Pump

 Pressure gauge to
control the system
pressure during the tests
at 6 Bar
Adjust of Dosing of Additive Pump

 Weighing Scale Bucket

 With 450 Kg/h selected and 6 pressure Bar, we running the test 3
minutes should get a quantity of 22,5 liters of water approximately
Adjust of Dosing of Additive Pump

 It may be the case that the test result may not be correct,
then will be necessary to modify the degree of filling of
additive (normally the filling ratio is between 90% and 95%)
Adjust of Dosing of Additive Pump

 To ensure that the adjustment has been made correctly,


repeat the process with a measure of 100 kg/h, obtaining a
final weight of 8.3 kg (liters) in 5 minutes