This document outlines building rules for residential, commercial, and institutional buildings in Chennai. For residential buildings, it specifies rules for ordinary residential buildings up to 300 sqm and G+1 floor height. It allows additional FSI for affordable housing. Ordinary commercial buildings up to 300 sqm and G+1 height are also permitted. Institutional buildings including schools, colleges, and government offices have no size limit but require a 1m wide internal passage and may qualify for additional FSI in some cases.
This document outlines building rules for residential, commercial, and institutional buildings in Chennai. For residential buildings, it specifies rules for ordinary residential buildings up to 300 sqm and G+1 floor height. It allows additional FSI for affordable housing. Ordinary commercial buildings up to 300 sqm and G+1 height are also permitted. Institutional buildings including schools, colleges, and government offices have no size limit but require a 1m wide internal passage and may qualify for additional FSI in some cases.
This document outlines building rules for residential, commercial, and institutional buildings in Chennai. For residential buildings, it specifies rules for ordinary residential buildings up to 300 sqm and G+1 floor height. It allows additional FSI for affordable housing. Ordinary commercial buildings up to 300 sqm and G+1 height are also permitted. Institutional buildings including schools, colleges, and government offices have no size limit but require a 1m wide internal passage and may qualify for additional FSI in some cases.
RESIDENTIAL BUILDING Ordinary residential / predominantly residential buildings, Clinics, dispensaries, nursing homes with floor area not exceeding 300 sq.m. and G+1 floor in height. Working women hostels / old age homes with floor area not exceeding 500 sq.m. and G+1 floor in height. Corporate / Institution Guesthouses with floor area not exceeding 300 sq.m. and G+1 floor in height. Cottage industries (with number of workers not exceeding 8 and electric machineries not exceeding 5 H.P.) with floor area not exceeding 300 sq.m. and G+1 floor in height. Nursery schools, primary schools with floor area not exceeding 300 sq.m. Reading rooms, libraries, Post office, EB Office, telegraphic office, Local body maintenance offices with floor area not exceeding 300 sq.m. (i) In CBA, there shall be atleast 1m wide internal passage from rear to front in Ground floor, directly accessible to road. (ii) In cases of Residential or predominantly residential developments, - (a) where dwelling units for Economically Weaker Sections do not exceed 30 sq.m in floor area each, 50% of normally permissible FSI is additionally allowable over and above the normally permissible FSI; and - (b) where dwelling units for Low Income Group do not exceed 50 sq.m in floor area each, 30% of normally permissible FSI is additionally allowable over and above the normally permissible FSI; Provided that the developer or promoter or owner shall not sell these dwellings for other than the said purposes and no conversion or amalgamation shall be permissible in these cases of lower income group dwellings Ordinary Commercial Buildings and other small developments
Ordinary commercial / predominantly commercial buildings including
shops, private offices, banks, restaurants, fuel filling stations with or without service stations, Departmental stores, clinical labs, Schools of Commerce, with floor area less than 300 sq.m. and up to Ground +one floor. INDUSTRIAL ZONE SPECIAL & HAZARDOUS INDUSTRIES INSTITUTION BUILDING • Including nursery schools, Primary schools and religious buildings with floor area exceeding 300 sq.m. Secondary schools, Colleges, Higher Educational, Technical & Research Institutions, Students hostels & Dormitories, Research Institutions, Broadcasting, Telecasting & Telecommunication centers, Government & Quasi Government offices, and Institutions, Government archives, Museums, Art galleries and Public libraries, foreign missions, Consulates and embassies. • In CBA, there shall be atleast 1m wide internal passage from rear to front in Ground floor, directly accessible to road. • In cases of Government and Quasi-Government hospital buildings an additional FSI of 0.25 is allowable over and above the normally permissible FSI.