Hydraulic schematic SD

Elevators
VC control

Blohm+Voss Oil Tools 01


a Forum Energy Technologies Company
Load Sensor

Sequence Valve

Trigger Valve

Feedback valve
Door Sensor

XP control valve Feedback pressure control valve

02
Throttle check
valves for
door/latch speed

Bypass ball valve Load sensor


Bypass ball valve A - B
Bypass ball valve Trigger

03
SD Elevator VC control
Schematic continues on next page

Elevator close
Feedback

Tank

Feedback
Power
Tank

P= Elevator close
P, XP = Elevator open

85 Bar 04
Feedback

Power
Tank

A: Elevator close
Schematic continues on previous page B: Elevator open
C: Feedback signal
05
SD Elevator VC control
Schematic continues on next page

Elevator open

Tank

Open Signal
Power
Tank

P= Elevator close
P, XP = Elevator open
min 120 Bar 06
Power

Tank

A: Elevator close
B: Elevator open
C: Feedback signal
Schematic continues on previous page
07
Troubleshooting on SD
Elevators

Blohm+Voss Oil Tools 08


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Latch and Door doesn't close


• Check quick connectors
• Check system pressure on line “P” 160-210 Bar
• Check that there is no pressure present in line XP
• Check trigger position (Adjust to the inserts)
• Check that bypass valve Pressure/Tank is fully closed
• Activate the trigger valve by hand
or open the trigger bypass valve
• Check bypass valve seals P/T
• Check that door cylinder is undamaged
• Open throttle check valve

Blohm+Voss Oil Tools 09


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control
Latch and Door doesn't open
• Check quick connectors
• Check system pressure on line “P “and “XP” 160-210 Bar
• Check that bypass valve Pressure/Tank is fully closed
• Open load sensor bypass valve
If the elevator opens, check adjustment
of load sensor valve
Check mechanical load sensor parts.
• Check XP control valve adjustments
valve #5 (fully in and ¼-½ turn out) and
valve #4 (120 bar)

• Check bypass valve seals P/T


• Check that latch cylinder is undamaged 4
• Open throttle check valves

Blohm+Voss Oil Tools 10


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

The latch stays in the open position

• Check system pressure on line “P” 160-210 Bar


• Check that bypass valve Pressure/Tank is fully closed
• Check that the door is fully closed
and the door sensor #5 is activated
• Loosen the mounting screws #4 and push
the valve forward to the max. position
• Check all parts from the cylinder bearing plate #1
• Check that the Cylinder yoke #10 is undamaged
• Check that latch cylinder is undamaged
• Open the throttle check valve

10

Blohm+Voss Oil Tools 11


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Opening elevator, latch opens, door stays closed

• Check system pressure on line “P” 160-210 Bar


• Check that bypass valve Pressure/Tank is fully closed
• Adjust “fine tuning valve” to fully open
• Adjust sequence valve, turn to left to lower the
required sequence pressure
• Check that latch cylinder is undamaged
• Open the throttle check valve
• Replace sequence valve
• Replace check valve

Blohm+Voss Oil Tools 12


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Latch and door opens at same time

• Check system pressure in line “P” 160-210 Bar


• Adjust “fine tuning valve” to fully open
• Adjust sequence valve, turn to right to increase the
required sequence pressure

• Replace sequence valve


• Replace check valve
Ensure the elevator is well greased

Blohm+Voss Oil Tools 13


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control
Latch is trying to open as soon as the feedback for “elevator closed” is shown
4

• Adjust the XP control valve to 120 bar as


shown on page 21

• Check that the flow reducing valve is correct


adjusted. Fully in and ¼ - ½ turn out

• Make sure the feedback signal pressure for


„elevator closed“ is not higher than 85 bar
otherwise the feedback signal is able to
activate the elevator open function.
Adjust the feedback pressure control valve
if required.

Blohm+Voss Oil Tools 14


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

No feedback signal

• Check quick connectors


• Check system pressure on line “P” 160-210 Bar
• Check that door and latch are fully closed
and the feedback valve is activated #5
• Loosen the mounting screws #4 and push
the valve forward to the max. position (elevator closed)
• Check all parts from the cylinder bearing plate #1
• Check that the Cylinder yoke #10 is undamaged
• Check that latch cylinder is undamaged
• Adjust feedback control valve, turn in to increase (85 bar)

10

Blohm+Voss Oil Tools 15


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Elevator close without trigger actuated (fast and slowly)

• Check that trigger bypass valve is closed


• Check that the trigger valve is not permanent activated
To adjust the valve, loosen both screws on the backside
and pull the valve back to the correct position
• Check the trigger bypass valve seals and
replace if necessary
Please note, always replace the whole valve,
don’t replace single parts
Ensure that the bore is free from impurities!
• Replace trigger valve
• Replace all involved check valves
Seal kit for bypass valve
P/N 645307-RK

Blohm+Voss Oil Tools 16


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Elevator opens when under load

• Check that load sensor bypass valve is fully closed


• Check that the load sensor valve is correct adjusted (activated under load)
• Check the load sensor bypass valve seals and replace if necessary
Please note, always replace the whole valve,
don’t replace single parts
Ensure that the bore is free from impurities!
• Check brass bushing, turn or replace if worn
• Check load sensor pin
• Replace load sensor valve

Blohm+Voss Oil Tools 17


a Forum Energy Technologies Company
How to adjust SD Elevators

Blohm+Voss Oil Tools 18


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Feedback -
pressure control
valve

XP control valve

Blohm+Voss Oil Tools 19


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

How to adjust the load sensor

• Remove all inserts


• Push down the load ring with a
C-clamp or testing tool
• Loosen the two small screws #5
• Loosen adjusting screw #6
• Turn the adjusting screw to the right, to
push the valve forward. Ensure the valve
is in one line with the pin #10 C-clamp
If you feel the valve is fully activated,
tighten all screws. Load ring
• Try to open the elevator
Load sensor
• Remove the C-clamp
• Carry out a full function test Testing tool

Blohm+Voss Oil Tools 20


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

How to adjust door and latch speed


Latch opening speed • Screw in to decrease the operating speed
• Screw out to increase the operation speed
Latch closing speed
• Always adjust to a medium speed level!
First setting, full way
in than 3 ¼ turns out • Adjust and test on different pressure levels
Door opening speed
Door closing speed

“Latch valves” are located


on the backside

“Door valves”

Blohm+Voss Oil Tools 21


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

How to adjust door and latch speed

Additional rig floor adjustments

• Open trigger bypass valve


• Check that door and latch closing well
• Rotate the elevator upwards
• Close the Elevator
• If the doors starts to judder, reduce the
door or latch speed
• Function test
• Don’t forget to close the bypass valve
Important test for SD500 Frame 2 elevator
Use inserts for this test

Blohm+Voss Oil Tools 22


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control
How to adjust door and latch opening sequence
• Open the trigger bypass
• Close the elevator
• Screw in the upper sequence valve to the max position
• Screw out the lower valve to the max position
• Open the elevator (Door stays closed)
• Start to screw out the upper valve step by step
stop if the door starts to open well (+1/4 turn)
• Close the elevator and carry out a function test
• If the sequence is not adjustable check that the door
speed valve is correct adjusted (door open)
and use the lower sequence valve
• Don’t forget to close the trigger bypass
Adjust and test the elevator on
different pressure levels

The lower valve is only for


additional adjustments.
Regular position is fully open
Trigger bypass valve
Blohm+Voss Oil Tools 23
a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control
How to adjust the trigger valve
• Check that trigger bypass valve is closed
• To adjust the valve, loosen both screws on the
backside of the valve
• Pull the trigger valve back to get more space
between actuator and stopper
• Tighten the mounting screws
• Function test
Check the mechanical trigger adjustment
according to used pipe size
actuator
Check that the trigger valve is not permanent activated

Space between
Stopper
actuator and stopper

Blohm+Voss Oil Tools 24


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control
How to adjust XP control setup 4
• Turn the flow reducing valve No. 5 fully in,
then a ¼ - 1/2 turn out and secure.
• Turn the Feedback pressure control valve
No. 03 fully out
• Adjust the XP control valve No. 4 to fully in
• Reduce the pressure level in line XP to
120 bar for correct adjustments, before you
connect the hydraulics to the unit.
• Supply pressure to port P and XP
• Start to adjust the XP control valve until the
elevator starts open properly.
• Secure the valve and adjust XP pressure supply back to 160 – 210 bar
• Close the elevator and adjust the feedback to approx. 85 bar by using the feedback
pressure control valve. The feedback is shown in line XP.

If it is not possible to adjust the pressure supply in line XP, you can adjust the XP
control valve to the current XP pressure level and turn the valve an additional ½ turn
out to cover pressure fluctuations.

Blohm+Voss Oil Tools 25


a Forum Energy Technologies Company
Prepare of SD Elevators for
operation

Blohm+Voss Oil Tools 26


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Prepare of SD elevators for operation

• Check for loose items, damaged parts,


broken parts and loose screws
• Check for corrosion
• Check the condition of the bushing
retainer plate
• Grease all greasing points

Grease
daily!

Blohm+Voss Oil Tools 27


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Prepare of SD elevators for operation

• Start with first function test at maintenance area


• Open the elevator and shut down the hydraulic supply
• Remove all inserts
• Connect the hydraulic supply
• Close the elevator
• Check the load sensor function with C-Clamp
The load ring sinking approximately 5mm and it is not
possible to open the elevator. In case the load sensor doesn't
work, check bypass valve and adjust the load sensor
valve as shown on page 20

Adjusting Screw

Load ring
Load sensor

Blohm+Voss Oil Tools 28


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

• To get more space for the adjustments, remove the rear cover.
To do so, shut down the hydraulic supply and disconnect quick connectors.
Remove the three hydraulic supply hoses, both mounting screws for
the manifold and the eight screws for the rear cover.

1. 2. 3.

To save time, install quick connectors on the in step one disconnected hydraulic hoses

• Open the elevator and check the trigger function


Switch to “elevator close” and activate the trigger by hand.
If the elevator closes by itself, check the trigger bypass valve
and adjust the trigger as shown on page 24

Blohm+Voss Oil Tools 29


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

• Open and close the elevator a couple of times to check the opening sequence
1. Latch opens 2.Door opens

• Check that the lower valve is fully open


If not, adjust to fully open by hand

• Check the sequence again


If the sequence is not working proper, loosen
the lock nut (size 14mm) on the upper valve
and adjust with an Allen key (size 4mm)
• Adjust as shown on page 23
Check the sequence on
different pressure levels, to
make sure the elevator is
working at the drill floor as well
160 Bar – 210 Bar
Drill floor 180Bar

Blohm+Voss Oil Tools 30


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

• Check door and latch opening speed


• If the latch opens/closes to slow or to fast
pull the manifold on the left hand side out of the body
Make sure the rear cover is removed
• Now you have access to the valves on the
back side of this manifold
• Adjust like shown on page 21
• First setting, full way in then 3 ¼ turns out
• If the door opens/closes to slow or to fast
• Adjust the throttle check valves wit an Allen key
like shown on page 21
• Always adjust to a medium speed level!

• Adjust and test on different pressure levels

• Check the opening sequence after speed


adjustments

Blohm+Voss Oil Tools 31


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

• Check that all bypass valves are working proper


in open and closed position
If a bypass valve is damaged, replace all parts of the damaged valve (including plug)
Make sure you always use the updated version P/N 645307-RK

• Install rear cover and tighten the manifold mounting screws.


• Connect hydraulic hoses to the rear cover
• Carry out a full function test including trigger and load sensor
• Ensure the elevator is well greased and all items are secured

• The elevator is ready for operation

Blohm+Voss Oil Tools 32


a Forum Energy Technologies Company
FORUM B + V Oil Tools GmbH Troubleshooting SD Elevator VC control

Contact details for technical support

Frank Sasse John Kramer


Technical Superintendent Asst. Service Coordinator
After Sales and Service After Sales and Service
 
FORUM B + V Oil Tools GmbH FORUM B + V Oil Tools GmbH
Hermann-Blohm-Strasse 2 Hermann-Blohm-Strasse 2
20457 Hamburg 20457 Hamburg
Germany Germany
 
change of contact details: change of contact details:
Phone:  +49-40-3119-6860 Phone: +49-40-37022-6885
Fax:    +49-40-3119-3383 Fax:     +49-40-3119-3383
Mobile: +49-152-22517739 Mobile: +49-173-6465929
Mailto: frank.sasse@f-e-t.com Mailto: john.kramer@f-e-t.com
Internet:http://www.blohmvoss-oiltools.com Internet:http://www.blohmvoss-oiltools.com

Blohm+Voss Oil Tools 33


a Forum Energy Technologies Company

You might also like