Digital Transformer Protection
1
g MULTILI
N DTP
Digital Transformer Protection
Protection Functions
2
g MULTILI
N DTP
Digital Transformer Protection
Features
⬛Any Transformer Type
– Wye, B Delta, C Delta, B Zig-Zag, C Zig-Zag
⬛Any CT Connection
– Wye, B Delta, C Delta
3
g MULTILI
N DTP
Digital Transformer Protection
Features (Cont.)
⬛TripOutputs (5)
(User Selects Which Trip Signals Operate All 5 Outputs)
4
g MULTILI
N DTP
Digital Transformer Protection
Features (Cont.)
⬛Digital Inputs (5)
– Buchholz Alarm & Trip
– Overtemperature Alarm & Trip
– Trip Signaling
5
g MULTILI
N DTP
Digital Transformer Protection
Features (Cont.)
⬛Sequence of Event Recorder (255)
– User Can Select Which Events Will Be Recorded
⬛Present Value Monitoring
– Phase A, B, C Differential Currents
– Phase A, B, C Through Currents
6
g MULTILI
N DTP
Digital Transformer Protection
⬛Event Masks
– Phase A Instantaneous Pick-up – Buchholz Alarm Signaling
– Phase B Instantaneous Pick-up
– Overtemperature Alarm Signaling
– Phase C Instantaneous Pick-up – Trip
– Phase A Differential Pick-up
– Auxiliary Trip Signal
– Phase B Differential Pick-up – Non-Critical Alarm 101
– Phase C Differential Pick-up
– End of Non-Critical Alarm 101
– Overtemperature Trip Input – Setting Change
– Overtemperature Alarm Input
– Program Reset
– Buchholz Trip Input – Critical Alarm 204
– Buchholz Alarm Input
– Critical Alarm 201
– Latching Relay Reset Input – End of Critical Alarm
– Phase A, B, or C Instantaneous Signaling
– Clear Event File
– Phase A Instantaneous or Differential Signaling – Relay Synchronize
– Phase B Instantaneous or Differential Signaling
7
g MULTILI
N DTP
Digital Transformer Protection
Features (Cont.)
⬛Eight Fault Reports Stored
– RMS Differential Current
– RMS Through Current
– Trip Type
– Fault Type
8
g MULTILI
N DTP
Digital Transformer Protection
Features (Cont.)
9
g MULTILI
N DTP
Digital Transformer Protection
Communications
⬛2Line LED Display
⬛Local Keypad
⬛Present Values Viewed on Display by Pressing “ENT” Key
⬛Programmable Banks of Indicating LED’s
– Pick-ups, Inputs, Outputs, LED Test
⬛ReadyLED
⬛Remote Communication via M -LINK Software
– Display Present Values, Fault Report, Retrieve Oscillography, Retrieve
Sequence of Events, Change Settings
– Password Protected
10
g MULTILI
N DTP
Digital Transformer Protection
LED Configuration
⬛Setting: PICK-UPS ⬛Setting: OUTPUTS
L1 ---- L1 Correct Operation
L2 ---- L2 Instantaneous Trip
L3 Phase C Instantaneous L3 Trip Caused by a Fault in
Pickup Phase A
L4 Phase B Instantaneous L4 Trip Caused by a Fault in
Pickup Phase B
L5 Phase A Instantaneous L5 Trip Caused by a Fault in
Pickup Phase C
L6 Phase C Differential L6 Bushels Alarm
Pickup
L7 Overtemperature Alarm
L7 Phase B Differential
Pickup L8 Trip
⬛Setting: INPUTS
L1 ----
L2 ----
L3 ----
L4 Overtemperature Trip
L5 Overtemperature Alarm
11
L6 Buchholz Trip
g MULTILI
N DTP
Digital Transformer Protection
⬛Packaging
– 19” Rack Unit
– Horizontal Mounting (4 RU)
– Modular Construction
– Optional Oscillography
12
g MULTILI
N
Ordering DTP
Digital Transformer Protection
DTP * * * * * * * * * * * *
1 2
Winding
2 3
Winding
3 4
Winding
0
Without Test Plugs
1 With
Test Plugs
1 1
Amp Current Rating
5 5
Amp Current Rating
A 5A
for 1st Restraint, 1 A for All Others
B 1A
for 1st Restraint, 5 A for All Others
1
RS232 Communication Port
2 Fiber
Optic (1mm Plastic) Communication Port
3 Fiber
Optic (100/125 glass) Communication Port
4 Fiber
Optic (50/125 glass) Communication Port
M O With
Oscillography
P O
13
Without Oscillography
0