pdcchCfiMode (10MHz) CFI_AUTO_MAXIMUM_ CFI_AUTO_MAXIMUM_3 (no Recommended setting is already set, just monitor CCE
3 change) and CFI usage
pZeroNominalPucch -117 -117 (no change) Recommended setting is already set
SRB/DRB::dlMaxRetxThreshold 8/8 8/8 (no change) Max # RLC re-Tx in UL/DL (control signaling load).
SRB/DRB::ulMaxRetxThreshold 8/8 8/8 (no change) Recommended setting is already set
SRB/DRB::tPollRetransmitDl 45ms/50ms 80ms/80ms Increase poll timer for RLC re-Tx (if no status report
SRB/DRB::tPollRetransmitUl 45ms/50ms 80ms/80ms received) to avoid RLC failures, reduce signaling load
T310 / T311 20 / 1 20 / 1 (no change) Recommended setting is already set, for RLC
supervision
N310 / N311 2s / 3s 2s / 3s (no change) Recommended setting is already set, for RLC
supervision
a3Offset 30 (3dB) 50 (5dB) (low priority) Reduce signaling load. Will review feasibility to use
alternative approach on ‘UE Level Oscillating Handover
Minimization’ feature